• Title/Summary/Keyword: Injection process

Search Result 2,276, Processing Time 0.034 seconds

A pilot study of high flux membrane process for responding to influent turbidity changes in reservoir water (호소수 탁도변화 대응을 위한 고플럭스 막여과공정의 Pilot 연구)

  • Kang, Joonseok;Seong, Jayeong;Yoo, Jewan;Kim, Hyungsoo;Lee, Jaekyu;Jeon, Minhyuk;Cheon, Jihoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.6
    • /
    • pp.393-402
    • /
    • 2020
  • In the membrane process, it is important to improve water treatment efficiency to ensure water quality and minimize membrane fouling. In this study, a pilot study of membrane process using reservoir water was conducted for a long time to secure high flux operation technology capable of responding to influent turbidity changes. The raw water and DAF(Dissolved Air Flotation) treated water were used for influent water of membrane to analyze the effect of water quality on the TMP (Trans Membrane Pressure) and to optimize the membrane operation. When the membrane flux were operated at 70 LMH and 80 LMH under stable water quality conditions with an inlet turbidity of 10 NTU or less, the TMP increase rates were 0.28 and 0.24 kPa/d, respectively, with minor difference. When the membrane with high flux of 80 LMH was operated for a long time under inlet turbidity of 10 NTU or more, the TMP increase rate showed the maximum of 43.5 kPa/d. However, when the CEB(Chemically Enhanced Backwash) cycle was changed from 7 to 1 day, it was confirmed that the TMP increase rate was stable to 0.23 kPa/d. As a result of applying pre-treatment process(DAF) on unstability water quality conditions, it was confirmed that the TMP rise rates differed by 0.17 and 0.64 kPa/d according to the optimization of the coagulant injection. When combined with coagulation pretreatment, it was thought that the balance with the membrane process was more important than the emphasis on efficiency of the pretreatment process. It was considered that stable TMP can be maintained by optimizing the cleaning conditions when the stable or unstable water quality even in the high flux operation on membrane process.

Effect of H2O2 Injection and Temperature Changing on the Organic Carbon Fraction in Chromatogram Dissolved Organic Carbon (CDOC) from Thermal Pretreatment (H2O2 주입과 온도변화가 열적 전처리 후 발생 슬러리의 CDOC 유기탄소분율에 미치는 영향평가)

  • Kim, Hee-Joong;Kim, Tae-Kyoung;Kim, Youn-Kwon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.3
    • /
    • pp.110-116
    • /
    • 2016
  • Biogas yields point of view, the possibility of reusing excess sludge treated by thermal pretreatment for the purpose of improving the efficiency of the anaerobic digestion process has been investigated in recent year. Thermal pretreatment technology was considered as a pretreatment technique to improve excess sludge properties because of the solubilization of particulate organics. As a view point of sludge reduction and recycle, however, many researchers focused on the ability of particulate hydrolysis and COD solubilization under a high temperature, and few reports have addressed on the physical/chemical characteristics changing. This research was performed to evaluate the effects of a various temperature and chemical additives on carbon formation and fractionation in treated slurry from thermal pretreatment. Based on the results, it was revealed that oxidants injection and temperature changing have significantly caused the change of carbon fractions in slurry from thermal pretreament. Especially, it was considered that the efficiencies of particle hydrolysis increased with the increase of the reaction temperature. Low molecular weight(Mw < 350 g/mol) organic carbon formation increased with the increase of oxidants injection. It was expected that results of this research will provide an overview of the characteristics of thermal pretreatement for excess sludge reduction and recycle.

Artificial oocyte activation in intracytoplasmic sperm injection cycles using testicular sperm in human in vitro fertilization

  • Kang, Hee Jung;Lee, Sun-Hee;Park, Yong-Seog;Lim, Chun Kyu;Ko, Duck Sung;Yang, Kwang Moon;Park, Dong-Wook
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.42 no.2
    • /
    • pp.45-50
    • /
    • 2015
  • Objective: Artificial oocyte activation (AOA) is an effective method to avoid total fertilization failure in human in vitro fertilization-embryo transfer (IVF-ET) cycles. AOA performed using a calcium ionophore can induce calcium oscillation in oocytes and initiate the fertilization process. We evaluated the usefulness of AOA with a calcium ionophore in cases of total fertilization failure in previous cycles and in cases of severe male factor infertility patients with non-motile spermatozoa after pentoxifylline (PF) treatment. Methods: The present study describes 29 intracytoplasmic sperm injection (ICSI)-AOA cycles involving male factor infertility at Cheil General Hospital from January 2006 to June 2013. Patients were divided into two groups (control, n=480; AOA, n=29) depending on whether or not AOA using a calcium ionophore (A23187) was performed after testicular sperm extraction-ICSI (TESE-ICSI). The AOA group was further split into subgroups according to sperm motility after PF treatment: i.e., motile sperm-injected (n=12) and non-motile sperm-injected (n=17) groups (total n=29 cycles). Results: The good embryo rate (52.3% vs. 66.9%), pregnancy rate (20.7% vs. 52.1%), and delivery rate (10.3% vs. 40.8%) were lower in the PF/AOA group than in the control group. When evaluating the effects of restoration of sperm motility after PF treatment on clinical outcomes there was no difference in fertilization rate (66.6% vs. 64.7% in non-motile and motile sperm, respectively), pregnancy rate (17.6% vs. 33.3%), or delivery rate (5.9% vs. 16.7%) between the two groups. Conclusion: We suggest that oocyte activation is a useful method to ensure fertilization in TESE-ICSI cycles regardless of restoration of sperm motility after PF treatment. AOA may be useful in selected patients who have a low fertilization rate or total fertilization failure.

Evaluation of Crack-Repairing Performance in Concrete Using Surface Waves (표면탄성파를 활용한 콘크리트 균열 보수 성능 평가 기법)

  • Ahn, Eunjong;Kim, Hyunjun;Gwon, Seongwoo;Sim, Sung-Han;Lee, Kwang Myong;Shin, Myoungsu
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.4
    • /
    • pp.496-502
    • /
    • 2017
  • The purpose of this study is to investigate the applicability of surface-wave techniques for the evaluation of the crack-repairing performance of an epoxy injection method in concrete. In this study, box-shaped concrete specimens with four different crack depths were made with identical mix proportions. The specimens with different crack depths were completely repaired using the same epoxy injection method. The spectral energy transmission ratio of surface waves is used as an index to differentiate the effects of crack depth and crack-repairing performance. The decrease of spectral energy transmission ratio in accordance with the increase of crack depth was identified before repairing. Furthermore, the spectral energy transmission ratio increased after the crack-repairing process in all specimens. The spectral energy transmission ratio is considered as a great indicator for estimating the crack-repairing performance of the epoxy injection method; the ratio was recovered up to almost 95% of the uncracked condition.

The Estrus Manifestation according to the Follicle Size and the Growth Phase after $PGF_{2{\alpha}}$ Injection in Korean Native Cows (한우에서 $PGF_{2{\alpha}}$ 투여 후 난포 크기 및 발달 과정에 따른 발정 증상의 발현)

  • Park, Chul-Ho;Ryu, Jae-Sun;Yu, Dae-Jung;Park, In-Chul;Kim, Jong-Taek;Suh, Guk-Hyun;Oh, Ki-Seok;Son, Chang-Ho
    • Journal of Embryo Transfer
    • /
    • v.27 no.3
    • /
    • pp.141-147
    • /
    • 2012
  • This study was operated to establish induction using ultrasonography by estimating the relation of follicle size and estrus manifestation. Clinical estrus symptoms were observed 97.4% in cows and 87.5% in heifers when overall 55 cows were induced to estrus in a single dose of $PGF_{2{\alpha}}$ after verifying CL through ultrasonography, which means estrus hours among those 52 cows showing the clinical estrus symptoms were estimated 2.39 days on cows and for 2.37 days on heifers which showed no differences (p>0.05). The estrus manifestation hours according to the follicle size in cows didn't have any significance each other (p>0.05), though estrus hours was 54 hours (the shortest) with follicle size bigger than 10 mm and were made up within 69 hours. The estrus manifestation hours according to the follicle size in heifers didn't have any significance each other (p>0.05) and took around 42 hours (the shortest) with follicle size of 5mm (the smallest) and were made up within 66 hours. Follicles after $PGF_{2{\alpha}}$ injection were ovulated and assigned to many phases as follows; Group 1 (growing phase) - continuously growing into ovulation, Group 2 (growing and static phase) - delaying in growth after the growth of follicles, Group 3 (static and growing phase) - growing after growth delay, Group 4 (regressing and new growing phase) - the follicle is closed and a new follicle grows. In addition, the process of follicle development and estrus hours had no significance each other (p>0.05), though estrus manifestation hours in Group 1 and 2 was relatively short, and in Group 3 and 4 for a relatively long time. In the result of all above, the estrus manifestation hours after $PGF_{2{\alpha}}$ injection has no differences accoring to the follicle size in cows and heifers. Therefore, High pregnancy rate is obtained when practicing artificial insemination within 3 days in estrus or TAI in 72 to 80 hours after adminitrating $PGF_{2{\alpha}}$.

Management of Laryngeal Contact Granuloma (후두 접촉성 육아종의 치료)

  • Ko, Moon-Hee;Son, Young-Ik;Jang, Jeon-Yeob;So, Yoon-Kyoung;Chung, Man-Ki
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.19 no.2
    • /
    • pp.128-132
    • /
    • 2008
  • Background: Laryngeal contact granuloma is an inflammatory hypertrophic granulation tissue arising at around the vocal process of arytenoid cartilage. Various approaches are currently used for the treatment, but a solid guideline has not been established. Objectives: We aimed to compare the each treatment modality in the hope of suggesting a guideline for the successful management of laryngeal contact granuloma. Method: Eighty-seven treatment cases of 56 patients were analyzed. Cases having recent intubation history were excluded from the study. All patients received vocal hygiene education. Proton pump inhibitors (PPI, N = 33) or H2 receptor antagonists ($H_{2}RA$, N =26) were used as a first-line treatment. Among the non-responders to $H_{2}RA$, 11 cases received PPI as a second-line therapy. Eight cases received botulinum toxin injection and 9 cases had laryngomicrosurgical removal. Results: As an initial therapy, response rate to PPI and $H_{2}RA$ was 60.6% and 38.5% respectively, which was not statistically different (p=0.091). Response rate of PPI as the second-line therapy was 36.3% (p=0.162 when compared to that of first-line PPI therapy). Response rate of Botulinum toxin injection was 75%. All cases of surgical removal recurred in a relatively short period (mean 1.9months). Conclusion: In patients having laryngeal contact granuloma, combined therapy with vocal hygiene education and PPI medication would provide more than 60% of therapeutic response. Botulinum toxin injection is highly effective even in non-responders to antireflux therapy. The only indications of surgery are to resolve diagnostic doubt or to treat acute airway compromise.

  • PDF

A Study on the Stress Measurement in a Plastic Product using Chemical Cracking Method (케미칼 크랙킹 방법을 이용한 플라스틱 제품의 응력측정에 관한 연구)

  • Won, S.T.;Kim, T.B.;Lee, S.;Won, J.M.;Cha, K.H.;Lyu, M.Y.
    • Elastomers and Composites
    • /
    • v.47 no.4
    • /
    • pp.336-340
    • /
    • 2012
  • Residual stress in the injection molded part is originated from thermal shrinkage and shear stress during injection molding process. There are many measurement methods of residual stress in the plastic part. Residual stress in opaque products can be measured by chemical cracking test. This method enables the solvent and specimen to react and to cause cracks. Cracks developed according to the level of residual stress. Thus the stresses in plastic part can be quantitatively measured by counting the number of cracks or measuring the size of cracks. Relationship between stress and number of cracks in a plastic specimen has been investigated in this study. Bergen jig was used to give a strain in the specimens those were molded using PC/PBT and PC/ABS. Solvent for the chemical cracking test was prepared using tetrahydrofuran and methyl alcol with the ratio of 1 to 3. Stresses in the specimen can be calculated by strains those were imposed by Bergen jig. Cracks were developed for stress higher than certain level. The number of cracks increased by second order function for stress.

Time-dependent characteristics of viscous fluid for rock grouting (암반 그라우팅을 위한 점성유체의 시간의존 특성 분석)

  • Lee, Jong-Won;Kim, Ji-Yeong;Weon, Jo-Hyun;Oh, Tae-Min
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.465-481
    • /
    • 2022
  • Rock grouting is important to improve the waterproof efficiency and mechanical strength of rock medium with joint for utilizing the underground rock space such as tunnel. The grouting materials typically has been used the cement materials, which represent Bingham fluid model. This model can express the relationship of viscosity and yield strength. In addition, it is dependent with elapsed time. The grouting injection performance can be deteriorated with an increase of viscosity and yield strength in the grouting process if the time dependence is ignored. Therefore, in this study, the characteristics of viscosity and yield strength were investigated according to water-cement ratio and time dependence in the laboratory test. Numerical simulation was carried out to investigate the grouting performance according to the time dependence of characteristics in terms of the viscosity model. Given the results, the grouting injected distance and cumulative grout volume were significantly decreased when the time dependence of grouting material was considered. This study, considering the characteristics according to the time dependence of viscosity and yield strength, will be meaningful to the design of grouting injection in field applications.

Dynamic Threshold Determination Method for Energy Efficient SEF using Fuzzy Logic in Wireless Sensor Networks (무선 센서 네트워크에서 통계적 여과 기법의 에너지 효율 향상을 위한 퍼지논리를 적용한 동적 경계값 결정 기법)

  • Choi, Hyeon-Myeong;Lee, Sun-Ho;Cho, Tae-Ho
    • Journal of the Korea Society for Simulation
    • /
    • v.19 no.1
    • /
    • pp.53-61
    • /
    • 2010
  • In wireless sensor networks(WSNs) individual sensor nodes are subject to security compromises. An adversary can physically capture sensor nodes and obtain the security information. And the adversary injects false reports into the network using compromised nodes. If undetected, these false reports are forwarded to the base station. False reports injection attacks can not only result in false alarms but also depletion of the limited amount of energy in battery powered sensor nodes. To combat these false reports injection attacks, several filtering schemes have been proposed. The statistical en-routing filtering(SEF) scheme can detect and drop false reports during the forwarding process. In SEF, The number of the message authentication codes(threshold) is important for detecting false reports and saving energy. In this paper, we propose a dynamic threshold determination method for energy efficient SEF using fuzzy-logic in wireless sensor networks. The proposed method consider false reports rate and the number of compromised partitions. If low rate of false reports in the networks, the threshold should low. If high rate of false reports in networks, the threshold should high. We evaluated the proposed method’s performance via simulation.

In-situ Thermally Curable Hyper-branched 10H-butylphenothiazine

  • Jo, Mi-Young;Lim, Youn-Hee;Ahn, Byung-Hyun;Lee, Gun-Dae;Kim, Joo-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.492-498
    • /
    • 2012
  • A hyper branched 10-butylphenothiazine with in-situ thermally curable methacrylate (1,3,5-tris-[$\{$10-Butyl-3-(4-(2-methyl-acryloyloxy)-phenyl)-7-yl-10H-phenothiazine$\}$]-benzene, (tris-PTMA)) was synthesized successfully. From the TGA thermogram of tris-PTMA was thermally stable up to $336^{\circ}C$. In the first heating scan of DSC thermogram, tris-PTMA showed glass transition temperature (Tg) at $140^{\circ}C$ and broad endothermic process in the region of $144-179^{\circ}C$, which is thermally curing temperature. In the second heating process, $T_g$ exhibited at $158.7^{\circ}C$ and endothermic process was not observed. Thermally cured tris-PTMA showed no big change in the UV-visible spectrum after washing with organic solvent such as methylene chloride, chloroform, toluene, indicating that thermally cured film was very good solvent resistance. Thermally cured tris-PTMA was electrochemically stable and the HOMO energy level of tris-PTMA was -5.54 eV. The maximum luminance efficiency of double layer structured polymer light-emitting diode based on in-situ thermally cured tris-PTMA was 0.685 cd/A at 16.0 V, which was higher than that of the device without thermally cured tris-PTMA (0.348 cd/A at 15.0 V).