• Title/Summary/Keyword: Injection materials

Search Result 1,655, Processing Time 0.032 seconds

The Usefulness of Mammography and Scintimammography in Differential Diagnosis of Breast Tumor (유방 종괴에서 악성 감별을 위한 유방촬영술과 유방스캔의 유용성 연구)

  • Kang, Bong-Joo;Chung, Young-An;Jung, Hyun-Seok;Jung, Jung-Im;Yoo, Ie-Ryung;Kim, Sung-Hoon;Sohn, Hyung-Sun;Chung, Soo-Kyo;Hahn, Seong-Tai;Lee, Jae-Mun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.492-497
    • /
    • 2004
  • Purpose: it is very important to differentiate breast cancer from benign mass. There are many reports to evaluate the differential diagnosis under the several diagnostic tools. We evaluated the usefulness of mammography and Tc-99m MIBI scintimammography in the differential diagnosis of breast mass and correlated with pathologic findings. Materials and Methods: This study included 80 patients (a8e: 24-72, mean: 48.4) who underwent mammography and Tc-99m MIBI scintimammography for breast masses. Scintimammographies (anterior-posterior and lateral projections) were acquired in 10 minutes and 2 hours after intravenous injection of Tc-99m MIBI. four specialists in diagnostic radioloay and nuclear medicine evaluated the findings of breast masses under the mammography and Tc-99m MIBI scintimammography, and calculated the tumor to background (T/B) ratio. The pathologic results were obtained and we statistically analyzed the correlations between pathologic results and imaging findings under the mammography and Tc-99m MIBI scintimammography by chi-square and correlation test. Results: The sensitivity, specificity, positive predictive value, and negative predictive value of mammography for detection of breast cancer were 87.5%, 56.3%, 75.0%), and 75.0% respectively. 45 cases of 80 patients were suspicious for breast cancer under the Tc-99m MIBI scintimammography. 41 cases of 45 patients were confirmed as breast cancer and the remaining 4 cases were confirmed as benign masses. The sensitivity, specificity, positive predictive value and negative predictive value of Tc-99m MIBI scintimammography for detection of breast cancer were 85.4%, 87.5%, 91.1%, and 80.8% respectively. The sensitivity of scintimammography was lower than that of mammography for detection of breast cancer, however the specificity, positive predictive value, and negative predictive value were higher. In the benign mass, the mean T/B ratio in 10 minutes was $1.409{\pm}0.30$, and that in 2 hours was $1.267{\pm}0.42$. The maximal T/B ratio of benign mass in 10 minutes was $1.604{\pm}0.42$, and that in 2 hours was $1.476{\pm}0.50$. In the malignant mass, the mean T/B ratio in 10 minutes was $2.220{\pm}1.07$, and that in 2 hours was $1.842{\pm}0.75$. The maximal T/B ratio of malignant mass was $2.993{\pm}1.94$, and that in 2 hours was $2.480{\pm}1.34$. And the T/B ratio under the early and delayed images were meaningful. Conclusion: The scintimammography is useful diagnostic tool to differentiate breast cancer from benign mass, although the sensitivity of mammography for detection of breast mass is high. Especially, the use of the T/B ratio is helpful to diagnose breast cancer.

Comparison of Activity Capacity Change and GFR Value Change According to Matrix Size during 99mTc-DTPA Renal Dynamic Scan (99mTc-DTPA 신장 동적 검사(Renal Dynamic Scan) 시 동위원소 용량 변화와 Matrix Size 변경에 따른 사구체 여과율(Glomerular Filtration Rate, GFR) 수치 변화 비교)

  • Kim, Hyeon;Do, Yong-Ho;Kim, Jae-Il;Choi, Hyeon-Jun;Woo, Jae-Ryong;Bak, Chan-Rok;Ha, Tae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.27-32
    • /
    • 2020
  • Purpose Glomerular Filtration Rate(GFR) is an important indicator for evaluating renal function and monitoring the progress of renal disease. Currently, the method of measuring GFR in clinical trials by using serum creatinine value and 99mTc-DTPA(diethylenetriamine pentaacetic acid) renal dynamic scan is still useful. After the Gates method of formula was announced, when 99mTc-DTPA Renal dynamic scan is taken, it is applied the GFR is measured using a gamma camera. The purpose of this paper is to measure the GFR by applying the Gates method of formula. It is according to effect activity and matrix size that is related in the GFR. Materials and Methods Data from 5 adult patients (patient age = 62 ± 5, 3 males, 2 females) who had been examined 99mTc-DTPA Renal dynamic scan were analyzed. A dynamic image was obtained for 21 minutes after instantaneous injection of 99mTc-DTPA 15 mCi into the patient's vein. To evaluate the glomerular filtration rate according to changes in activity and matrix size, total counts were measured after setting regions of interest in both kidneys and tissues in 2-3 minutes. The distance from detector to the table was maintained at 30cm, and the capacity of the pre-syringe (PR) was set to 15, 20, 25, 30 mCi, and each the capacity of post-syringe (PO) was 1, 5, 10, 15 mCi is set to evaluate the activity change. And then, each matrix size was changed to 32 × 32, 64 × 64, 128 × 128, 256 × 256, 512 × 512, and 1024 × 1024 to compare and to evaluate the values. Results As the activity increased in matrix size, the difference in GFR gradually decreased from 52.95% at the maximum to 16.67% at the minimum. The GFR value according to the change of matrix size was similar to 2.4%, 0.2%, 0.2% of difference when changing from 128 to 256, 256 to 512, and 512 to 1024, but 54.3% of difference when changing from 32 to 64 and 39.43% of difference when changing from 64 to 128. Finally, based on the presently used protocol, 256 × 256, PR 15 mCi and PO 1 mCi, the GFR value was the largest difference with 82% in PR 15 mCi and PO 1 mCi. conditions, and at the least difference is 0.2% in the conditions of PR 30 mCi and PO 15 mCi. Conclusion Through this paper, it was confirmed that when measuring the GFR using the gate method in the 99mTc-DTPA renal dynamic scan. The GFR was affected by activity and matrix size changes. Therefore, it is considered that when taking the 99mTc-DTPA renal dynamic scan, is should be careful by applying appropriate parameters when calculating GFR in the every hospital.

The Analysis of Radiation Exposure of Hospital Radiation Workers (병원 방사선 작업 종사자의 방사선 피폭 분석 현황)

  • Jeong Tae Sik;Shin Byung Chul;Moon Chang Woo;Cho Yeong Duk;Lee Yong Hwan;Yum Ha Yong
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.157-166
    • /
    • 2000
  • Purpose : This investigation was peformed in order to improve the health care of radiation workers, to predict a risk, to minimize the radiation exposure hazard to them and for them to realize radiation exposure danger when they work in radiation area in hospital. Methods and Materials : The documentations checked regularly for personal radiation exposure in four university hospitals in Pusan city in Korea between January 1, 1993 and December 31, 1997 were analyzed. There were 458 persons in this documented but 111 persons who worked less then one year were excluded and only 347 persons were included in this study. Results : The average of yearly radiation exposure of 347 persons was 1.52$\pm$1.35 mSv. Though it was less than 50mSv, the limitaion of radiation in law but 125 (36%) people received higher radiation exposure than non-radiation workers. Radiation workers under 30 year old have received radiation exposure of mean 1.87$\pm$1.01 mSv/year, mean 1.22$\pm$0.69 mSv between 31 and 40 year old and mean 0.97$\pm$0.43 mSv/year over 41year old (p<0.001). Men received mean 1.67$\pm$1.54 mSv/year were higher than women who received mean 1.13$\pm$0.61 mSv/year (p<0.01). Radiation exposure in the department of nuclear modicine department in spite of low energy sources is higher than other departments that use radiations in hospital (p<0.05). And the workers who received mean 3.59$\pm$1.81 msv/year in parts of management of radiation sources and injection of sources to patient receive high radiation exposure in nuclear medicine department (p<0.01). In department of diagnostic radiology high radiation exposure is in barium enema rooms where workers received mean 3.74$\pm$1.74 mSv/year and other parts where they all use fluoroscopy such as angiography room of mean 1.17$\pm$0.35 mSv/year and upper gastrointestinal room of mean 1.74$\pm$1.34 mSv/year represented higher radiation exposure than average radiation exposure in diagnostic radiology (p<0.01). Doctors and radiation technologists received higher radiation exposure of each mean 1.75$\pm$1.17 mSv/year and mean 1.50$\pm$1.39 mSv/year than other people who work in radiation area in hospital (p<0.05). Especially young doctors and technologists have the high opportunity to receive higher radiation exposure. Conclusions : The training and education of radiation workers for radiation exposure risks are important and it is necessary to rotate worker in short period in high risk area. The hospital management has to concern health of radiation workers more and to put an effort to reduce radiation exposure as low as possible in radiation areas in hospital.

  • PDF

Studies on the Repeated Toxicity Test of Food Red No.2 for 4 Weeks Oral Administration in SD Rat (SD랫드에서 식용색소 적색2호의 4주간 경구투여에 따른 반복독성시험에 관한 연구)

  • Yoo, Jin-Gon;Jung, Ji-Youn
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.1
    • /
    • pp.42-49
    • /
    • 2012
  • This study was carried out to investigate the toxicity of food Red No.2 in the Sprague-Dawley (SD) female rat for 4 weeks. SD rats were orally administered for 28 days, with dosage of 500, 1,000, 2,000 mg/kg/day. Animals treated with food Red No.2 did not cause any death and show any clinical signs. They did not show any significant changes of body weight, feed uptake and water consumption. There were not significantly different from the control group in urinalysis, hematological, serum biochemical value and histopathological examination. In conclusion, 4 weeks of the repetitive oral medication of food Red No.2 has resulted no alteration of toxicity according to the test materials in the group of female rats with injection of 2,000 mg/kg. Therefore, food Red No.2 was not indicated to have any toxic effect in the SD rats, when it was orally administered below the dosage 2,000 mg/kg/day for 4 weeks.

The Effect of Interferon-γ on Bleomycin Induced Pulmonary Fibrosis in the Rat (Interferon-γ 투여가 쥐에서의 Bleomycin 유도 폐 섬유화에 미치는 영향)

  • Yoon, Hyoung Kyu;Kim, Yong Hyun;Kwon, Soon Seog;Kim, Young Kyoon;Kim, Kwan Hyung;Moon, Hwa Sik;Park, Sung Hak;Song, Jeong Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.1
    • /
    • pp.51-66
    • /
    • 2004
  • Objectives : The matrix metalloproteinases (MMPs) that participate in the extracellular matrix metabolism play a important role in the progression of pulmonary fibrosis. The effects of the MMPs are regulated by several factors including Th-1 cytokines, $interferon-{\gamma}$ ($IFN-{\gamma}$). Up to now, $IFN-{\gamma}$ is known to inhibit pulmonary fibrosis, but little is known regarding the exact effect of $IFN-{\gamma}$ on the regulation of the MMPs. This study investigated the effects of $interferon-{\gamma}$ on the pulmonary fibrosis and the expression of the lung MMP-2,-9, TIMP-1,-2, and Th-2 cytokines in aa rat model of bleomycin induced pulmonary fibrosis. Materials and methods : Male, specific pathogen-free Sprague-Dawley rats were subjected to an intratracheal bleomycin instillation. The rats were randomized to a saline control, a bleomycin treated, and a bleomycin+$IFN-{\gamma}$ treated group. The bleomycin+$IFN-{\gamma}$ treated group was subjected to an intramuscular injection of $IFN-{\gamma}$ for 14 days. At 3, 7, 14, and 28 days after the bleomycin instillation, the rats were sacrificed and the lungs were harvested. In order to evaluate the effects of the $IFN-{\gamma}$ on lung fibrosis and inflammation, the lung hydroxyproline content, inflammation and fibrosis score were measured. Western blotting, zymography and reverse zymography were performed at 3, 7, 14, 28 days after bleomycin instillation in order to evaluate the MMP-2,-9, and TIMP-1,-2 expression level. ELISA was performed to determine the IL-4 and IL-13 level in a lung homogenate. Results : 1. 7 days after bleomycin instillation, inflammatory changes were more severe in the bleomycin+$IFN-{\gamma}$ group than the bleomycin group (bleomycin group : bleomycin+$IFN-{\gamma}$ group=$2.08{\pm}0.15:2.74{\pm}0.29$, P<0.05), but 28 days after bleomycin instillation, lung fibrosis was significantly reduced as a result of the $IFN-{\gamma}$ treatment (bleomycin group : bleomycin+$IFN-{\gamma}$ group=$3.94{\pm}0.43:2.64{\pm}0.13$, P<0.05). 2. 28 days after bleomycin instillation, the lung hydroxyproline content was significantly reduced as a result of $IFN-{\gamma}$ treatment (bleomycin group : bleomycin+$IFN-{\gamma}$ group=$294.04{\pm}31.73{\mu}g/g:194.92{\pm}15.51{\mu}g/g$, P<0.05). 3. Western blotting showed that the MMP-2 level was increased as a result of the bleomycin instillation and highest in the 14 days after bleomycin instillation. 4. In zymography, the active forms of MMP-2 were significantly increased as a result of the $IFN-{\gamma}$ treatment 3 days after the bleomycin instillation, bleomycin+$IFN-{\gamma}$ group (bleomycin group : bleomycin+$IFN-{\gamma}$ group=$209.63{\pm}7.60%:407.66{\pm}85.34%$, P<0.05), but 14 days after the bleomycin instillation, the active forms of MMP-2 were significantly reduced as a result of the $IFN-{\gamma}$ treatment (bleomycin group : bleomycin+$IFN-{\gamma}$ group=$159.36{\pm}20.93%:97.23{\pm}12.50%$, P<0.05). 5. The IL-4 levels were lower in the bleomycin and bleomycin+$IFN-{\gamma}$ groups but this was not significant, and the IL-13 levels showed no difference between the experiment groups. Conclusion : The author found that lung inflammation was increased in the early period but the pulmonary fibrosis was inhibited in the late stage as a result of $IFN-{\gamma}$. The inhibition of pulmonary fibrosis by $IFN-{\gamma}$ appeared to be associated with the inhibition of MMP-2 activation by $IFN-{\gamma}$. Further studies on the mechanism of the regulation of MMP-2 activation and the effects of MMP-2 activation on pulmonary fibrosis is warranted in the future.