• Title/Summary/Keyword: Infrared analysis

Search Result 2,240, Processing Time 0.028 seconds

Application of Near Spectroscopy for Nondestructive Evaluation of Ginsenoside Content

  • Lin, Guo-Lin;Cho, Rae-Kwang;Hong, Jin-Hwan
    • Near Infrared Analysis
    • /
    • v.1 no.2
    • /
    • pp.45-48
    • /
    • 2000
  • The effective component Ginsenoside in Ginseng has been widely used to cure some hypochondriasis and be as supplementary medicines. There are many chemical analysis methods to measure the contents of Ginsenoside in Ginseng; however, all these methods have some shortcomings such as long time, environmental pollution and damaging the samples. In this paper, it is possible to use near infrared spectroscopy to measure the content of Ginsenoside in Ginseng without destruction. As the results, Rg1, Rb1, Re and T-Saponin of Ginsenoside can be measured with the accuracy of R(0.81) SEP (1.704 mg/g), R(0.74) SEP (1.211 mg/g), R (0.78) SEP (1.049 mg/g) and R(0.84), SEP(4.537 mg/g).

Automatic Intelligent Asymmetry Detection Using Digital Infrared Imaging with K-Means Clustering

  • Kim, Kwang Baek;Song, Doo Hoen
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.15 no.3
    • /
    • pp.180-185
    • /
    • 2015
  • Digital infrared thermal imaging is a non-invasive adjunctive diagnostic technique that allows an examiner to visualize and quantify changes in skin surface temperature. The asymmetry of temperature differences between the diseased and the contralateral healthy body parts can be automatically analyzed and has been studied in many areas of medical science. In this paper, we propose a method for intelligent automatic asymmetry detection based on a K-means analysis and a YCbCr color model. The implemented software successfully visualizes an asymmetric distribution of colors with respect to the patients’ health status.

Quantitative Measurement of Ethane Using Mid-infrared Cavity Ring-down Spectroscopy

  • Yonghee Kim;Byung Jae Chun;Lim Lee;Kwang-Hoon Ko;Seung-Kyu Park;Taek-Soo Kim;Hyunmin Park
    • Current Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.457-462
    • /
    • 2023
  • Quantitative measurement of trace ethane is important in environmental science and biomedical applications. For these applications, we typically require a few tens of part-per-trillion level measurement sensitivity. To measure trace-level ethane, we constructed a cavity ring-down spectroscopy setup in the 3.37 ㎛ mid-infrared wavelength range, which is applicable to multi-species chemical analysis. We demonstrated that the detection limit of ethane is approximately 300 parts per trillion, and the measured concentration is in agreement with the amounts of the injected sample. We expect that these results can be applied to the chemical analysis of ethane and applications such as breath test equipment.

Development of robust Calibration for Determination Sweetness of Fuji Apple fruit using Near Infrared Reflectance Spectroscopy

  • Sohn, Mi-Ryeong;Kwon, Young-Kill;Cho, Rae-Kwang
    • Near Infrared Analysis
    • /
    • v.2 no.1
    • /
    • pp.55-58
    • /
    • 2001
  • The object of this work was to investigate the influence of growing district and harvest year on calibration for sweetness (Brix) determination of Fuji apple fruit using near infrared (NIR) reflectance spectroscopy, and to develop the robust calibration across these variation. The calibration models was based on wavelength range of 1100∼2500 nm using a stepwise multiple linear regression. A calibration model by sample set of one growing district was not transferable to other growing districts. The combined calibration (data of three growing districts) predicted reasonable well against a population set drawn from all growing districts (SEP=0.69, Bias=0.075). A calibration model by sample set of one harvest year was not also transferable to other harvest years. The combined calibration (data of three harvest years) predicted well against a population set drawn from all harvest years (SEP=0.53, Bias=0.004).

GROUND-BASED NEAR-INFRARED CENSUS FOR YOUNG STAR CLUSTERS IN THE DWARF STARBURST GALAXY NGC 1569

  • Kyeong, Jae-Mann;Sung, Eon-Chang;Kim, Sang-Chul;Chaboyer, Brian
    • Journal of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • JHK near-infrared photometry of star clusters in the dwarf irregular/dwarf starburst galaxy NGC 1569 are presented. After adopting several criteria to exclude other sources (foreground stars, background galaxies, etc.), 154 candidates of star clusters are identified in the near-infrared images of NGC 1569, which include very young star clusters. Especially, from analysis based on theoretical background, we found ten very young star clusters near the center of NGC 1569. The total reddening values toward these clusters are estimated to be $A_V$=1-9 mag from comparison with the theoretical estimates given by the Leitherer et al. (1999)'s star cluster model.

A study on the characteristic analysis and correction of non-linear bias error of an infrared range finder sensor for a mobile robot (이동로봇용 적외선 레인지 파인더센서의 특성분석 및 비선형 편향 오차 보정에 관한 연구)

  • 하윤수;김헌희
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.641-647
    • /
    • 2003
  • The use of infrared range-finder sensor as the environment recognition system for mobile robot have the advantage of low sensing cost compared with the use of other vision sensor such as laser finder CCD camera. However, it is not easy to find the previous works on the use of infrared range-finder sensor for a mobile robot because of the non-linear characteristic of that. This paper describes the error due to non-linearity of a sensor and the correction of it using neural network. The neural network consists of multi-layer perception and Levenberg-Marquardt algorithm is applied to learning it. The effectiveness of the proposed algorithm is verified from experiment.

Potential of near infrared spectroscopy for non-destructive estimation of soluble solids in growing melons

  • Ito, Hidekazu;Morimoto, Susumu;Yamauchi, Ryougo
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1525-1525
    • /
    • 2001
  • Non-destructive determination of soluble solids(Brix) in harvested fruits using near infrared(hereafter, NIR) spectroscopy has been reported by many researchers. We have just reported on non-destructive estimation of Brix in harvested melons using a NIR Systems Model 6500 spectrophotometer(Ito et al., 2000). There is a melon cultivar that is difficult to judge the harvest time from the external appearance. If we can determine Brix in growing fruits non-destructively in the field, immature fruits will not be harvested. A portable m spectrophotometer for field use has been just developed by Kubota Corporation. The spectral data of growing melons were measured by the portable spectrophotometer. A commercial program was used for multiple linear regression analysis. Brix in growing melons could be estimated by a multiple regression equation calibrated with harvested melons. Absorbances of 906 and 874 nm were included as the independent variables in the multiple regression equation, and these wavelengths are key wavelengths for non-destructive Brix determination.

  • PDF

Materials Characterization Using A Novel Simultaneous Near-Infrared/X-ray Diffraction Instrument

  • Yeboah, S.Agyare;Blanton, Thomas;Switalski, Steve;Schuler, Julie;Analytical, Craig Barnes
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1288-1288
    • /
    • 2001
  • X-ray powder diffraction (XRD) is utilized for determination of polymorphism in crystalline organic materials. Though convenient to use in a laboratory setting, XRD is not easily adapted to in situ monitoring of synthetic chemical production applications. Near-Infrared spectroscopy (NIR) can be adapted to in situ manufacturing schemes by use of a source/detector probe. Conversely, NIR is unable to conclusively define the existence of polymorphism in crystalline materials. By combining the two techniques, a novel simultaneous NIR/XRD instrument has been developed. During material's analysis, results from XRD allow for defining the polymorphic phase present, and NIR data are collected as a fingerprint for each of the observed polymorphs. These NIR fingerprints will allow for the development of a library, which can be referenced during the use of a NIR probe in manufacturing settings.

  • PDF

Determination of four Nutrients in Tomato with Near Infrared Spectrometry

  • Liu, Ling;Jin, Tongming
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1514-1514
    • /
    • 2001
  • In this paper a fast non-destructive analytical method to measure various nutrients in the intact tomato---Near infrared Spectrometry NIRs was introduced Using this method the content of some organic acid, vitamin C, reductive sugar, and solid soluble were determined simultaneously. Screen out four wavelengths at 916nm, 1000nm, 1004nm and 832nm to present optimum four optical terms of d$^2$ log(1/R) with second derivative spectra treating data scanned under these wavelengths. The multiple correlation coefficients between these values and those obtained on chemical analysis were 0.983, 0.990, 0.987, and 0.994, respectively, and the standard errors of prediction (SEP) were 0.007, 0.440, 0.037, and 0.057, respectively. These results indicate that NIRs is comparable to chemical methods in both accuracy and precision and is reliable method for determination of nutrients in intact tomato.

  • PDF

A Study on the Management Methods of the Ship Infrared Signature (함정 적외선 신호의 관리방법 연구)

  • Cho, Yong-Jin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.50 no.3
    • /
    • pp.182-189
    • /
    • 2013
  • In the development process of new naval ships, it is necessary to make the effort of the signature management and reduction of ship infrared(IR) signature to increase the ship survivability(susceptibility). So far the ship's contrast radiant intensity is used as a ship IR signature design criteria during the naval ship design stages. However, nowaday it is in a state of disorder at the basic design stage because of the lack of any related studies and methods. In this study, the IR signature management methods for improving the signature reduction and ship survivability are suggested by the comparison analysis of the advantages and disadvantages of signature management techniques. And also the criteria for the ship signature management are suggested when considering the infrared signature measuring assets and sea trial environments of the Korean peninsula.