• Title/Summary/Keyword: Infrared Technology

Search Result 1,997, Processing Time 0.031 seconds

Development of a Diagnostic Technique of the Historic Structures Using a Thermal Infrared Camera

  • Nakabeppu, Jiro;Maeda, Atsushi;Gotoh, Keinosuke
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.493-495
    • /
    • 2003
  • The establishment of the investigation and the maintenance technique is required for preservation of old structures in Japan. This study attempts to diagnose the deterioration status of the historic structures using the thermal infrared camera. In some structures, the difference of the spatio-temporal change was observed in the surface temperature. For example, the cold joint of concrete was examined using this method effectively. As a result of this study, we have found useful guidelines in developing methodology to conduct diagnosis of historic buildings by using thermal infrared camera.

  • PDF

Trends in non- destructive analysis using near infrared spectroscopy in food industry (식품 산업에서의 근적외선 분광법을 이용한 비파괴 분석법 동향)

  • Park, Jong-Rak
    • Food Science and Industry
    • /
    • v.55 no.1
    • /
    • pp.2-22
    • /
    • 2022
  • Near-infrared spectroscopy (NIRS) is one of the representative non-destructive and eco-friendly analysis methods used for rapid analysis of various ingredients in the food industry. To develop analysis model with NIRS, Chemometrics are applied after pre-treatment of spectrum. Many studies have been reviewed on the analysis of general and functional components for agricultural and livestock products. In the case of livestock products, some studies have been conducted for on-line analysis. This study investigated results on various samples and component applying near-infrared spectroscopy. Furthermore, the results according to sample condition were compared. It was confirmed that NIRS is applied to various fields in the food industry.

MONITORING THE EFFECT OF THE ULTRA-HIGH PRESSURE PRESERVATION TECHNOLOGY BY NEAR INFRARED REFLECTANCE SPECTROSCOPY

  • Kaffka, Karoly J.;Farkas, Jozsef;Seregely, Zsolt;Meszaros, Laszlo
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.2122-2122
    • /
    • 2001
  • The ultra-high pressure technology fur the preservation of foods is under intense research to evaluate its potential as an alternative or complementary process to traditional methods of food preservation. Traditional processing methods usually need a large amount of energy, may cause unwanted reactions in the food, leading to cooked flavor and loss of vitamins, etc. The application of ultra-high hydrostatic pressure for food processing consists of subjecting the food to pressures in the range of 100-1000 ㎫. The ultra-high pressure inactivates the microorganisms and some enzymes, promotes the germination of spores and extends the shelf-life of the foods. This new technology follows the “minimal processing” concept minimizing the quality degradation, saving the vitamins, essential nutrients and flavors as well as utilizing less energy. We joined the research team at our University involved in the mentioned technology using an ultra-high pressure equipment, recording of the near infrared spectra and signal response of a chemosensor array (electronic nose) of their meat (beef and pork), vegetable and fruit samples exposed to different pressure. The results of our investigations achieved by evaluating the measured data using PCA and PQS methods will be presented.

  • PDF

Scene-based Nonuniformity Correction Algorithm Based on Temporal Median Filter

  • Geng, Lixiang;Chen, Qian;Qian, Weixian;Zhang, Yuzhen
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.3
    • /
    • pp.255-261
    • /
    • 2013
  • Scene-based nonuniformity correction techniques for infrared focal-plane arrays have been widely considered as a key technology, and various algorithms have been proposed to compensate for fixed-pattern noise. However, the existed algorithms' capability is always restricted by the problems of convergence speed and ghosting artifacts. In this paper, an effective scene-based nonuniformity correction method is proposed to solve these problems. The algorithm is an improvement over the constant statistics method and a temporal median is utilized with the Gaussian kernel to estimate the nonuniformity parameters. Also theoretical analysis is conducted to demonstrate that effective ghosting artifacts elimination and superior convergence speed can be obtained with the proposed method. Finally, the performance of the proposed technique is tested with infrared image sequences with simulated nonuniformity and with infrared imagery with real nonuniformity. The results show the proposed method is able to estimate each detector's gain and to offset reliably and that it performs better in increasing convergence speed and reducing ghosting artifacts compared with the conventional techniques.

Infrared Target Recognition using Heterogeneous Features with Multi-kernel Transfer Learning

  • Wang, Xin;Zhang, Xin;Ning, Chen
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.9
    • /
    • pp.3762-3781
    • /
    • 2020
  • Infrared pedestrian target recognition is a vital problem of significant interest in computer vision. In this work, a novel infrared pedestrian target recognition method that uses heterogeneous features with multi-kernel transfer learning is proposed. Firstly, to exploit the characteristics of infrared pedestrian targets fully, a novel multi-scale monogenic filtering-based completed local binary pattern descriptor, referred to as MSMF-CLBP, is designed to extract the texture information, and then an improved histogram of oriented gradient-fisher vector descriptor, referred to as HOG-FV, is proposed to extract the shape information. Second, to enrich the semantic content of feature expression, these two heterogeneous features are integrated to get more complete representation for infrared pedestrian targets. Third, to overcome the defects, such as poor generalization, scarcity of tagged infrared samples, distributional and semantic deviations between the training and testing samples, of the state-of-the-art classifiers, an effective multi-kernel transfer learning classifier called MK-TrAdaBoost is designed. Experimental results show that the proposed method outperforms many state-of-the-art recognition approaches for infrared pedestrian targets.

Performance Comparison of Thermal Imagers with Uncooled and Cooled Detectors For Fire Fighting Application (비냉각형 적외선 센서를 이용한 열상시스템과 냉각형 적외선 센서를 이용한 열상시스템의 화재 진압 시 성능 비교)

  • Kim, Byung-Hyuk;Jung, Han;Kim, Young-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.2
    • /
    • pp.128-132
    • /
    • 2007
  • Thermal Imaging systems are reported to be crucial for fire fighting and beginning to be used by fire fighters. The performance of thermal imaging system is determined by both the radiation of infrared from the target and the attenuation of infrared signal in the optical path by the absorption, scattering, diffraction and reflection. In the scene of fire, water drops with various sizes such as vaporized water, wafer mist from sprinkler, and wafer to suppress the fire reside with various gas generated by burning. To measure the transmission of infrared radiation in the scene of fire, fire simulating system and thermal imagers with cooled detector which detects $3{\sim}5{\mu}m$ infrared and uncooled detector fabricated by the MEMS technology which detects $8{\sim}12{\mu}m$ infrared. are made. With thermal imagers and Ire simulating system, the change of thermal image with respect to the change of visibility controlled with the burned fas was measured. It was found that the transmission of infrared was not reduced by the burned gas, which could be explained by the long wavelength of infrared ray compared with visible ray. However, the transmission of infrared ray was largely reduced by the combination of burned gas and water mist supplied by sprinkler. This is contrary to the results of calculated transmission through the pure water mist and shows that the transmission of infrared ray is mostly affected by the compounds of water mist and burned gas. In this case, it was found that the uncooled detector which detects $8{\sim}12{\mu}m$ infrared ray is better than cooled detector which detects $3{\sim}5{\mu}m$ infrared ray for fire fighting.

INLINE NEAR INFRARED (NIR) SPECTROSCOPY FOR PROCESS CONTROL IN POLYMER EXTRUSION

  • Rohe, Thomas;Koelle, Sabine;Becker, Wolfgang;Eisenreich, Norbert;Eyerer, Peter
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1082-1082
    • /
    • 2001
  • Extrusion is one of the most important processes in polymer industry. The characterization of the polymer melt during processing will improve this process noticeably, One possibility of characterizing the actual processed polymer melt is the inline near infrared (NIR) spectroscopy, With this method several polymer properties can be observed during processing, e.g. composition, moisture ormechanical properties of the melt. For this purpose probes for transmission and reflection measurements have been developed, withstanding the high temperatures and pressures appearing during extrusion process (tested up to 300$^{\circ}C$ and 10 ㎫). For the transmission system an optical bypass was developed to eliminate disturbing spectral influences and hence increase the long term stability, which is the prerequisite for an industrial application. Measurements in transmission and reflection produced comparable results (or blending processes, where the prediction error was less than 1%. An optimum RMSEP of only 0.24% was found for preprocessed polymer blends measured in transmission on a laboratory extruder. A transflection measurement allowed for the first time the recording of relevant NIR-spectra in the screw area of an extruder. The application to a (PE+PP) blending process delivered promising results. This new measurement mode allows the observation of the ongoing processes within the screw area, which is of maximum Interest for reactive extrusion processes. Due to economic reasons the calibration transfer between different extrusion systems is also of high importance. Investigations on simulated and real-world spectra showed that a calibration transfer is possible. A new method alternatively to the well-known direct standardization procedures was developed, which is based on an automatic data pretreatment. This procedure delivers comparable results for the calibration transfer. Overall this paper presents concepts, components and algorithms for the inline near infrared (NIR) spectroscopy for polymer extrusion, which allows the use of it in a real industrial extrusion process.

  • PDF

Study of the hydrogen concentration of SiNx film by Fourier transform infrared spectroscopy (Fourier transform infrared spectroscopy를 이용한 SiNx박막의 수소농도 연구)

  • Lee, Seok-Ryoul;Choi, Jae-Ha;Jhe, Ji-Hong;Lee, Lim-Soo;Ahn, Byung-Chul
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.3
    • /
    • pp.215-219
    • /
    • 2008
  • The bonding structure and composition of silicon nitride (SiNx) films were investigated by using Fourier transform infrared spectroscopy (FT-IR). SiNx films were deposited on Si substrate at $340^{\circ}C$ using a conventional PECVD system. The compositions of Si and N in SiNx films were confirmed by using Rutherford backscattering spectroscopy (RBS) and photoluminescence (PL) analysis. The surface morphology of SiNx films was also analyzed by using atomic force microscopy (AFM). It was found that the contents of NH(at. %) is the reverse related with those of SiH corresponding to the result of FT-IR. we conclude that a quantitative analysis on SiNx films can be possible through a precise detection of the contents of H in SiNx films with a FT-IR analysis only.

Optical waveguide structure design of Non-dispersive Infrared (NDIR) CO2 gas sensor for high-sensitivity (이산화탄소 검출을 위한 고감도 비분산 적외선 가스센서의 광도파관 구조 설계)

  • Yoon, Jiyoung;Lee, Junyeop;Do, Namgon;Jung, Daewoon
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.331-336
    • /
    • 2021
  • The Non-dispersive Infrared (NDIR) gas sensor has high selectivity, measurement reliability, and long lifespan. Thus, even though the NDIR gas sensor is expensive, it is still widely used for carbon dioxide (CO2) detection. In this study, to reduce the cost of the NDIR CO2 gas sensor, we proposed the new optical waveguide structure design based on ready-made gas pipes that can improve the sensitivity by increasing the initial light intensity. The new optical waveguide design is a structure in which a part of the optical waveguide filter is inclined to increase the transmittance of the filter, and a parabolic mirror is installed at the rear end of the filter to focus the infrared rays passing through the filter to the detector. In order to examine the output characteristics of the new optical waveguide structure design, optical simulation was performed for two types of IR-source. As a result, the new optical waveguide structure can improve the sensitivity of the NDIR CO2 gas sensor by making the infrared rays perpendicular to the filter, increasing the filter transmittance.