• Title/Summary/Keyword: Influent water quality

Search Result 187, Processing Time 0.024 seconds

Application of SBR Process to Treat Pickling Wastewater including the High Nitrate and Ca+2 (고농도 질산성질소와 Ca+2을 함유한 산세폐수의 효과적인 처리를 위한 SBR 공정의 적용)

  • Kim, Seung-jun;Choi, Yong-su;Bae, Woo-keun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.215-221
    • /
    • 2006
  • This research presents results from laboratory and pilot-scale experiments to remove high-nitrate in pickling wastewater using the sequencing batch reactor (SBR) as a biological method. During the experimental periods, the influent concentrations of NOx-N and $Ca^{+2}$ were analyzed to be 350-1,600 and 700-800 mg/L, respectively. In order to provide carbon source for denitrification, methanol has been added in proportion to the influent nitrate loading. The mean concentrations of MLSS and MLVSS, the fraction of volatile solids in sludge and the sludge volume index were measured to be 27 g/L, 5 g/L, 18.5% and 7.5, respectively. The solid retention time was kept in the range of 18 to 22 days, specific denitrification rate ($U_{dn}$) was $0.301g{NO_3}^--N/gVSS/day$. The oxidized nitrogen concentration of effluent ranged 2-34 mg/L with an average of 5.2 mg/L, the overall reduction in total nitrogen was more than 99.2%. In order to treat the pickling wastewater including the high concentration of nitrate and $Ca^{+2}$, the continuous flow process is not suitable because the specific gravity of the sludge is considerably increased by $Ca^{+2}$, thus the SBR process is shown to be very effective to treat the pickling wastewater.

Monitoring of Micro Noxious Chemicals Caused by Fiber and Chemistry Industrial Wastewater on the Nakdong River Water System (낙동강 수계의 섬유 및 화학 산업폐수로부터 발생하는 미량유해화학물질의 모니터링)

  • Kim Man-Il;Kang Mee-A
    • The Journal of Engineering Geology
    • /
    • v.16 no.2 s.48
    • /
    • pp.145-152
    • /
    • 2006
  • Industry development caused numerical and quantitative increase of noxious chemical substances that contain risk assessment in water resources. For use of efficient water resources a pre-treatment of contaminant source which is flowed in water resources is recognized in essential process. Therefore, the discharged water quality from discharged company began to control contaminant by total amount of pollutant in domestic. However, to estimate closely chemical substances it is not proved up to now, monitoring is very important. This study achieved a monitoring of micro noxious chemical substance by fiber and chemistry industrial wastewater inflow to examine risk assessment of the water system of Nakdong river. Chloroform was measured highest among volatile organic compounds (VOCs) that the results of water quality of influent and effluent are detected from 7 companies of study area. The other side, because measured value of detected chloroform is indefinite detection level in the same company, it is difficulty in management of water quality. However it may not be much effects of the water system of Nakdong river because these company's effluent is high treatment efficiency of chloroform (more than 88%) in sewage treatment plant. On the other hand, in the investigated results for the European Union specified priority substance that is detected to relationship influent and effluent from fiber/chemistry associated industries, these substances were not detected and domestic data was hardly referred. Therefore, data construction of continuous monitoring about this water quality may have to be achieved certainly to utilize as country policy.

Water Quality Monitoring of the upper region of Wonchun stream using EROD-microbioassay (EROD-microbioassay에 의한 원천천 상류지역 수질조사)

  • 고성룡;정규혁
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.4
    • /
    • pp.105-109
    • /
    • 2000
  • The purpose of this study is to investigate on the water quality of the upper region of Wonchun stream located in Suwon city by chemical analysis and EROD-microbioassay methods using rat hepatoma cell line H4IIE. The water samples were collected at 6 sampling sites from sept. to Nov. 1999 and determined the quantitative toxic effects. Higher levels of BO $D_{5}$, CO $D_{Cr}$ and CO $D_{Mn}$ were determined at M6 site where the influent contains domestic and industrial wastewater. EROD activity of water samples was ranged from 3.43$\pm$0.08 to 9.05$\pm$0.10 pmol/mg protein/min. High correlation with EROD activities and COD values was observed. From the results, the upper region of Wonchun stream water area was presumed to be highly polluted with various persistent organic chemicals.s.

  • PDF

Application of the Proper Air Supply Amount Based on the Influent Water Quality for the Development of Efficient Blower Control Logic in Sewage Treatment Plants (하수처리장의 효율적인 Blower Control Logic 개발을 위한 유입수질 기반 공기공급량 적용 연구)

  • Yeo, Wooseok;Kim, Jong Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.493-499
    • /
    • 2022
  • The standards pertaining to the quality of discharged water in sewage treatment plants are strengthening, and accordingly, facilities in sewage treatment plants are being upgraded. In addition, the discharge water quality of sewage treatment plants must be maintained at a high level, and efficient sewage treatment plant operations have thus emerged as a very important issue. For the efficient operation of sewage treatment plants, this study applied a basic blowing amount calculation method based on sewage facilities to evaluate the required oxygen amount and blowing amount according to inflow water quality by logicizing various influencing factors. As a result of calculating the amount of air blown by applying actual April water quality data from sewage treatment plant A to the blower demand calculation developed through this study, it was found that the average amount of air blown was reduced by about 12%. When the blower demand calculation developed here is applied to an actual sewage treatment plant, the amount of air blown can be controlled based on the inflow water quality. This can facilitate the realization of an autonomous control of sewage treatment plants, in contrast to the existing sewage treatment operation method that relies on operational experience of operator. In addition, it is expected that efficient sewage treatment plants can be operated by reducing blowing amounts and power costs, which will contribute to both energy and carbon savings.

Variation of Pollutant Removal Efficiency and Backwashing Effect of BAC Basin in Advanced Water Treatment Processes (고도정수공정에서 오염물질 제거효율 변화특성과 BAC조의 역세척에 따른 영향)

  • Park, Soo-Yee;Lee, Sang-Bong;Sin, Sang-Min;Jun, Chang-Jea;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.1
    • /
    • pp.45-53
    • /
    • 2008
  • In this paper, the property of influent water and variations of removal efficiencies in each unit processes were studied based on the experiment data from the advanced water treatment plant in a city of Korea. The microbial species in the biological activated carbon(BAC) after backwashing of activated carbon filtration tank(ACFT) were also identified. The property and the removal efficiencies were evaluated by considering 8-9 items. The variations of 4 items were investigated from the influent and effluent of ACFT. SEM recording were conducted on BAC samples before and after backwashing. And the existence of attached microorganisms were identified through HPC(Heterotrophic Plate Counter) investigation. For the property of influent water, the concentrations of most items were maintained in the constant ranges, some items had seasonal properties. For the removal efficiencies, there were some items showing similar monthly-pattern and increasing with time, other items decreasing at the ozone contactor. Through these investigations, it was possible to distinguish the target items, which were removed by the advanced processes. The existence of microorganisms in ACFT could be predicted based on the variation curve of NH$_3$-N, and this fact were proved by SEM and HPC.

The Removal Characteristics of THM Formation Potential According to the Changes of Bromide Concentration of Influent Water in BAC Process (생물활성탄 공정에서 계절별 유입수의 $Br^-$ 농도변화에 따른 THM 생성능 구성종별 제거 특성)

  • Son, Hee-Jong;Yoo, Pyung-Jong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.5
    • /
    • pp.378-381
    • /
    • 2009
  • The purpose of this research is the evaluation of removal efficiency of THMFP in BAC. The changes of four types of THMFP and total THMFP were examined in the influent and effluent of BAC filter from March to December in 2008. It turned out that the amounts of brominated THMFP were obviously higher in winter and autumn compared to the spring and summer, which also resulted in an increase of the total-THMFP levels during winter and autumn. In addition, long-term running of BAC filter shows the good removal function of chloroform formation potential, but not brominated THMFP; with further bromination, this function was declined, as it shows the formation of bromoform in BAC filter during October and December. These results were caused by changing of the proportion of $Br^-$/DOC.

Stoichiometric Study for Nitrogen Removal in Anoxic-oxic Process (무산소-산소 공정에서 양론적 질소제거 연구)

  • Lee, Byung-Dae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.11
    • /
    • pp.1222-1227
    • /
    • 2005
  • Optimal sludge recycling ratio for maximum total nitrogen(TN) removal efficiency was calculated stoichiometrically using nitrification and denitrification reaction with given influent water qualities in anoxic-oxic process which was one of the popular nitrogen removal system. The water quality items for stoichiometric calculation were ammonia, nitrite, nitrate, alkalinity, COD, and dissolved oxygen which could affect nitrification and denitrification. Optimal sludge recycling ratio for maximum TN removal efficiency was expressed by those five influent water qualities. TN concentration calculated stoichiometrically had kept good relationship with reported TN concentration in each tank and final effluent. In addition, it was possible to expect the TN concentration in final effluent by stoichiometric calculation within ${\pm}5.0\;mg/L$.

Road Runoff Treatment using Pilot Scale-NPS Treatment Plant Filling up Expended Polypropylene Media (발포고분자여재가 충전된 파일럿 규모의 비점오염물질 처리장치를 이용한 도로 강우유출수 처리)

  • Kim, Seogku;Oh, Hyecheol;Ahn, Jaehwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.10
    • /
    • pp.711-718
    • /
    • 2014
  • Investigated the processing characteristics of the pollutants and runoff due to storm events in the actual application of the road fields and a Non-Point Sources (NPS) pilot scale equipment. This phenomenon has occurred in the influent bypass the blockage occurs after 90 min the expended polymeric media was filled with filtered column. When entering a treatment tank SS 200 mg/L or more high concentration of effluent treatment efficiency was reduced from the reaction time 60 min. Influent concentration less then SS 180 mg/L was stable handling. The $COD_{Cr}/SS$ ratio were analyzed with 0.67, median value. Showed 92.1% and 82.3% respectively with an average removal rate of the SS and the $COD_{Cr}$. If the influent concentration of TP is the 0.5 mg/L or less, the quality of the treated water is 0.1 mg/L levels were expressed in a stable process. And when entering the 1.0 mg/L or more of the treated water, had a greater than average 0.2 mg/L. If the influent concentration of TN is 4~10 mg/L, the treatment water quality level was kept a 1.5~3.0 mg/L. The average removal efficiency of TP and TN respectively 73.9%, 50.4%.

Water quality analyses between tap water and treated water by point-of-use water dispenser systems (정수기 공급수인 수돗물과 정수기 통과수의 수질차이 분석)

  • Park, Keun-Young;Park, Ji-Won;Kim, Jae-Hyeok;Na, Yeong;Maeng, Sung-Kyu;Kim, Sung-Pyo;Kweon, Ji-Hyang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.5
    • /
    • pp.395-404
    • /
    • 2019
  • The point-of-use water dispenser systems are widely used because of convenience in handling and demand for high-quality drinking water. The application has been increased recently in the public places such as department stores, universities and the rest areas in express ways. Improvement of water qualities by the dispenser systems was compared with tap water in this study. The tap water is supplied to the dispenser as the influent of the dispenser system. The twelve dispensers in the public places were used. The five dispensers used reverse osmosis as the main filter and other dispensers used various filters such as ultrafiltration, nanofiltration, and alumina filter. The water quality indicators for sanitation safety, i.e., turbidity and total coliforms, were evaluated. Other water qualities such as pH, residual chlorine, heterotrophic plate count (HPC), and total cell counts were also analyzed. By the point-of-use water dispenser, the turbidity, residual chlorine and pH were decreased and the HPC and total cell counts were increased. The t-test results revealed that the HPC of the tap waters were not significantly different from the treated waters but the total cell counts of the two groups were significantly different. The low pH of the RO filter treatment was also significantly different from the tap waters. This study will contribute to understand the role of the point-of-use water dispenser in improving water quality and to identify key water quality for the proper maintenance of the dispenser systems.

Correlation analysis between TOC and organic matter indices in influent and effluent of public sewage treatment facilities (공공하수처리시설 유입수 및 방류수에서 TOC와 유기물질 관리지표간의 상관성 분석)

  • Son, Dong-Jin;Jeong, Dong-Hwan;Park, Kyoo-Hong
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.4
    • /
    • pp.122-129
    • /
    • 2021
  • As the total organic carbon (TOC) becomes a new water quality standard as an organic matter (OM) index for public sewage treatment facilities (PSTFs) in Korea from 2021, a comparison study needs to be conducted by examining the correlation between TOC and the existing OM indices (DOC, BOD5, CODMn, CODCr). 500 PSTFs were categorized by process configuration and capacity, and correlation between OM indices in influent and effluent was analyzed. The CODMn/TOC showed higher correlation than other OM indices. This results can be used to basic data for various research associated with TOC.