• 제목/요약/키워드: Influent water quality

Search Result 187, Processing Time 0.028 seconds

Performance Evaluation of WWTP Based on Reliability Concept (신뢰성에 기초한 하수처리장 운전효율 평가)

  • Lee, Doo-Jin;Sun, Sang-Woon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.348-356
    • /
    • 2007
  • Statistical and probabilistic method was used in the analysis of data, which is the most effective one in describing the various natures, and the methodology relating the results with the design was developed. Influents and effluents of three treatment plants were analyzed and the focus was made on BOD, COD, SS, IN, TP The fluctuations of influent such as BOD, COD, SS were extremely large and their standard deviations(st.dev) were more than 10 mg/L. but those of TN, TP were small; the st.dev was 6.6 mg/L for TN, 0.6 mg/L for TP, respectively. But, effluent concentration showed consistent pattern regardless of the influent fluctuations, the st.dev was ranged between 0.28 and 4.48 mg/L. Effluent distributional characteristics were as follows; BOD, COD were distributed normally, but SS, TN, and TP, log-normally; unsymmetric and skewed to the right. The coefficient of reliability(COR) based on the results of statistics of data was introduced to evaluate the process performance an4 to reflect the process performance to the process design. The coefficient of reliability relates the design value(the goal) with the standards and it can be used in operating treatment facilities under a certain reliability level and/or in evaluating the reliability of the treatment facilities on operation. Each treated water quality of effluent showed the half of water quality standards in the level of 50% percentile and all treatment plant was achieved 100% probability of water quality standards. It was concluded that the variability of the process performance should be reflected to the design procedure and the standards through the analysis based on the statistics and the probability.

Water Quality Changes in Wastewater Effluent from the Unsaturated and Saturated Soil Aquifer Treatment(SAT) Columns Simulating Shallow Aquifer (얕은 불포화 및 포화 대수층을 모사한 SAT 토양칼럼에서의 하수처리장 방류수 처리 수질 변화)

  • Cha Woo-Suk;Kim Jung-Woo;Choi Hee-Chul;Won Jong-Ho;Kim In-Soo;Cho Jae-Weon
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.5
    • /
    • pp.18-24
    • /
    • 2005
  • Water quality changes of wastewater effluent in the shallow aquifier condition was investigated using laboratory unsaturated and saturated SAT columns for over five months. Average DOC removal was 31.9% in the unsaturated SAT column whereas no removal occurred in the saturated SAT column. Under the shallow aquifer condition, nitrification was not completed in the unsaturated SAT column, releasing residual ammonium nitrogen into the saturated SAT column. Short retention time (one day) in the shallow unsaturated SAT column rendered DO of about 2 mg/L to the influent of the saturated SAT column. Phosphate was not removed at all in the unsaturated SAT column while complete removal was achieved in the saturated column. Consequently, organic and inorganic compounds were removed under the shallow aquifer condition as effectively as was in deep aquifer, except for the release of ammonium and relatively high DO into the saturated SAT column.

Evaluation of Influent Water Quality Using Indicator Microorganisms in Lake Shiwha (지표미생물을 이용한 시화호 유입수의 수질평가)

  • Lee, Hee-Tae;Kim, Hee-Yeon;Park, Hyun-Jin;Cho, Young-Eun;Ryu, So-Young;Lee, Kyung-Jin;Jung, Jong-Sun;Ko, Gwang-Pyo
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.1
    • /
    • pp.86-94
    • /
    • 2008
  • Lake Shiwha, an artificial lake located near metropolitan Seoul, offers a unique water environment and has been suspected to have high levels of chemical and microbiological contaminations. Lake Shiwha was originally connected to the sea but currently has four major surface water inputs from agricultural, municipal, industrial areas and in addition an occasional inflow from the sea. The objectives of this study are to investigate the relative contribution of microbial contaminants from each of the inflowing surface waters and to identify appropriate microbial indicator organisms in this unique water environment. We measured the levels of microbial contaminations in the four inflowing surface waters. A number of microbial indicator organisms including total coliform (TC), fecal coliform (FC), E. coli, Enterococci, somatic and male-specific coliphages were analyzed. Bacterial indicator microorganisms were detected and quantified by the $Colilert^{(R)},\;Enterolert^{(R)}$ kit. Surface water (50 l) was sampled by $ViroCap^{TM}\;5"$ cartridge filters and analyzed by the single agar layer method for detecting coliphages. The concentrations of TC, FC, E. coli, and Enterococci were 1543 CFU/100 ml${\sim}1.99{\times}10^6$ CFU/100 ml, 0 CFU/100 ml${\sim}202$ CFU/100ml, 0 CFU/100 ml${\sim}1.80{\sim}10^5$ CFU/100ml, 74 CFU/100 ml${\sim}3408$ CFU/100 ml, respectively. The male-specific and somatic coliphages were detected in three different inflowing surface waters. Isolated E. coli and Enterococci strains were further analyzed by 16s rDNA amplification and subsequent phylogenetic analysis from Jungwang-chun, Ansan-chun, Banwol-chun and penstock of inflowing surface water. Our results indicated that the concentrations of different fecal indicator microorganisms might not be highly correlated with each other. Multiple microbial indicator organisms should be used for monitoring microbial contamination and microbial source tracking methods.

Nitrate Removal Rate in Cattail Wetland Cells of a Pond-Wetland System for Stream Water Treatment (하천수정화 연못-습지 시스템 부들 습지셀의 초기 질산성질소 제거)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.5 no.6
    • /
    • pp.24-29
    • /
    • 2002
  • Nitrate removal rate in three cattail wetland cells was investigated. They were a part of a pond-wetland system for stream water treatment demonstration. The system was composed of two ponds and six wetland cells. The acreage of each cell was approximately $150m^2$. The earth works for the system were finished from April 2000 to May 2000 and cattails were planted in the three cells in June 2000. Waters of Sinyang Stream flowing into Kohung Estuarine Lake were pumped into a primary pond, whose effluent was discharged into a secondary pond. The reservoir was formed by a tidal marsh reclamation project and located in southern coastal area of Korean Peninsula. Effluents from the secondary pond were funneled into the three cells. Volumes and water quality of inflow and outflow were analyzed from July 2000 through January 2001. Inflow and outflow averaged $20.2m^3/day$ and $19.8m^3/day$, respectively. Hydraulic retention time was about 1.6 days. Average influent and effluent nitrate concentration was $1.98mg/{\ell}$, $1.38mg/{\ell}$, respectively. Nitrate removal rate averaged $82.6mg\;m^{-2}\;day^{-1}$. Seasonal changes of nitrate retention rates were closely related to those of wetland cell temperatures. The average nitrate removal rate in the cells was a little lower, compared with that of $125.0mg\;m^{-2}\;day^{-1}$ for the wetlands operating in North America. This could be attributed to the initial stage of the cells and inclusion of three cold months into the seven-month study period. Root rhizosphere in wetland soils and litter-soil layers on cell bottoms could not developed. Increase of standing density of cattails within a few years will establish both root zones suitable for the nitrification of ammonia to nitrates and substrates beneficial to the denitrification of nitrates into nitrogen gases, which may lead to increase of the nitrate retention rate.

Bacterial Removal Efficiencies by Unit Processes in a Sewage Treatment Plant using Activated Sludge Process (활성슬러지공정 하수종말처리장의 단위공정별 세균 제거효율)

  • Lee, Dong-Geun;Jung, Mira;Sung, Gi Moon;Park, Seong Joo
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.871-879
    • /
    • 2010
  • To figure out the removal efficiency of indicator and pathogenic bacteria by unit processes of a sewage treatment plant using activated sludge process, analyses were done for incoming sewage, influent and effluent of primary clarifier, aeration tank, secondary clarifier and final discharge conduit of the plant. A matrix of bacterial items (average of bacterial reduction [log/ml], p value of paired t-test, number of decreased cases of twenty analyses, removal percentage only for decreased cases) between incoming sewage and final effluent of the plant were heterotrophic plate counts (1.54, 0.000, 20, 95.01), total coliforms (1.38, 0.000, 19, 83.94), fecal coliforms (0.90, 0.000, 20, 94.84), fecal streptococci (0.90, 0.000, 20, 98.08), presumptive Salmonella (0.23, 0.561, 7, 99.09), and presumptive Shigella (1.02, 0.002, 15, 92.98). Total coliforms, fecal coliforms, heterotrophic plate counts, and fecal streptococci showed highest decrease through secondary clarifier about 1-log (p<0.001) between 88% and 96%, and primary clarifier represented the significant (p<0.05) decrease. However, final effluent through discharge conduit showed higher total coliforms and fecal streptococci than effluent of secondary clarifier (p<0.05). In addition, final effluent once violated the water quality standard while effluent of secondary clarifier satisfied the standard. Hence some control measures including elimination of deposits in discharge conduit or disinfection of final effluent are necessary.

Paddy Rice Culture Experiment Using Treated Sewage Effluent From Constructed Wetland (인공습지 오수처리수를 이용한 벼재배 실험)

  • 윤춘경;함종화;우선호;김민희
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.2
    • /
    • pp.94-104
    • /
    • 2001
  • A pilot study was performed at the experimental field of Konkuk University in Seoul, to examine the feasibility of the constructed wetland system for sewage and the effect of treated sewage irrigation on the paddy rice culture and its soil characteristics. The constructed wetland performed well, in that effluent concentrations of pollutants were significantly lower than concentrations of the influent. Median removal efficiencies of BOD$_{5}$ was about 78% and slightly lower during winter. Removal efficiencies form TN and TP were approximately 48 and 21%, respectively, and relatively less effective than that of BOD$_{5}$. Irrigation of treated sewage to paddy rice culture did not affect adversely in both growth and yield of rice. Instead, plots of treated sewage irrigation showed up to 50% more yield in average than the control plot. It implies that treated sewage irrigation might be beneficial to rice culture rather than detrimental as long as it is treated adequately and used properly. Soil was sampled and analyzed before transplanting and after harvesting. pH was slightly increased due to irrigation water, but it may not be concerned as long as the treated sewage is within the normal range. EC was increased in first year but decreased in second year, therefore salts accumulation in the soil could be less concerned. OM and CES was slightly increased, which might be beneficial on growing plants. TN did not show apparent pattern. Available phosphorus was decreased after rice culture, but the quantity of phosphorus(TP-available phosphorus) was rather increased which implies that excessive phosphorus supply may result in phosphorus accumulation in the soil. Overall, the constructed wetland was thought to be an effective sewage treatment alternative, and treated sewage could be reused as a supplemental source of irrigation water for paddy rice culture without causing adverse effect as long as it is treated adequately and used properly. For full-scale application, further investigation should be followed on environmental risk assessment, tolerable water quality, and fraction of supplemental irrigation.ion.

  • PDF

A Study on Performance Estimation and Operation Strategy of Biological Aerated Filter Using Semi-Empirical Biofilm Model (준 경험 생물막 모델(Semi-Empirical Biofilm Model)을 이용한 BAF 운전평가 및 적정 운전방안 도출)

  • Yoo, Kwangtae;Kim, Jongrack;Yun, Zuwhan;Hwang, Hojae;Lee, Hansaem;Kim, Sungpyo
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.3
    • /
    • pp.269-282
    • /
    • 2014
  • The objective of this study is to find out whether the developed semi-empirical biofilm model can be applicable to real BAF pilot-scale wastewater treatment. In addition, the optimum operating conditions of BAF as a function of process variables such as organic loading change can be drawn based on the simulation results of model. The results will provide the economic and efficient BAF process design and operating control. As a result, developed semi-empirical biofilm model which is relatively simple compared to mathematical model can simulate three BAF processes consisted of 25 layers within 1 seconds. When this model was used for simulating real pilot scale BAF process and the simulated water quality values were compared to experimental ones, simulated TCOD, SCOD, TN, $NH_4{^+}$-N, $NO_x{^-}$-N, alkalinity values were different to experimental ones within 21%, 20%, 8.1%, 48%, 10%, and 23%, respectively. Therefore, if the BAF system was equipped with automatic control, the BAF process can be better efficiently adapted under the condition of significant change of influent loading.

Effects of Sludge Pre-Treatment on the Excess Sludge Production in a Membrane-Coupled Bioreactor (막결합형 생물반응조에서 슬러지 전처리가 잉여슬러지 발생량에 미치는 영향)

  • Lee, Kang-Hoon;Kim, Ju-Hyun;Nguyen, Hai;Yeom, Ick-Tae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.565-572
    • /
    • 2011
  • The effects of chemical pretreatments on the excess sludge production in the membrane-coupled bioreactor were investigated. In addition, their effects on membrane fouling were also evaluated. Two membrane bioreactors were operated. In one reactor, a part of the mixed liquor was t reated with NaOH and ozone gas consecutively and was returned to the reactor. T he f lowrate of the chemical pretreatment stream was 1.5% of the influent flowrate. During the 200days of operation, the MLSS level in the bioreactor with mixed liquor pretreatment was maintained relatively constant at the range of 8,000 ~ 10,000$mg/{\ell}$ while it increased steadily up to 26,000 $mg/{\ell}$ in the absence of the pretreatment. Each reactor was equipped with two laboratory membrane modules where the flux for each module was 20, and 30 ${\ell}/m^2{\cdot}h$, respectively. With pretreatment, almost constant transmembrane pressure(TMP) was observed throughout the operation at the flux of 20 ${\ell}/m^2{\cdot}h$. Without pretreatment the membrane module at the same flux could also be operated at relatively stable condition. However, as the MLSS increases up to 25,000 $mg/{\ell}$, a fast TMP increase was observed. In conclusion, a complete control of excess sludge production in the membrane-coupled bioreactor was possible without significant deterioration of the treated water quality. In addition, it was shown that stable operation in terms of TMP is possible with sludge pretreatment and recirculation.

A Study on Operation of Sand Filters Coated with Manganese (망간사화된 모래여과지 운영에 관한 연구)

  • Jeong, Se-Chae;Ko, Su-Hyun;Kim, Jin-Keun;Yoo, Jeong-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.5
    • /
    • pp.558-562
    • /
    • 2006
  • Filtration experiments were conducted to determine the characteristics of manganese removal in filtration using 4 different filter media including sand and manganese sand(MS). Filtration velocity was 123 m/d and the flow rate was $3.9m^3/d$ per column. Duration of these experiments was about one year, and manganese dioxide accumulation, turbidity removal, manganese removal, and organic material removal were examined depending on filter media. When filter influent(residual chlorine 1.0 mg/L) with an average manganese concentration of 0.208 mg/L was fed through a filter column, the sand+MS and MS columns removed 98.9% and 99.2% of manganese respectively on an annual basis. When there is need to replace the sand filters with a MS filter to remove manganese, it was shown that the replacement of a partial sand filter with MS had adequate manganese removal.

Development of airflow control technology for Korean-type bioreactor based on influent water quality (유입수질 기반 한국형 생물반응조 송풍량 제어 기술 개발)

  • Yeo, Wooseok;Woo, Jea Suk;Song, Dong Hoon;Shin, Sung Bok;Kim, Jong Kyu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.388-388
    • /
    • 2022
  • 하수처리 공정 중 생물반응조에서는 미생물의 산화 반응을 통해 하수 내 각종 유기물들을 처리하고 있다. 블로워는 호기조를 유리산소상태로 만들어 미생물들의 유기물 제어, 질산화가 원활하게 이루어질 수 있도록 지원하는 역할을 담당하고 있다. 그러나 실제 하수처리장에서는 유기물을 원활하게 처리하기 위하여 과도하게 블로워를 가동하고 있어 경제적인 측면에서 문제를 겪고 있다. 블로워를 통해 수중에 산소를 부족하게 공급할 경우 활성슬러지의 침전성이 저해되어 방류수 수질이 저해되는 반면, 용존산소가 과도하게 공급되어도 유기물질의 처리 효율은 증대되지 않으며 잉여용존산소는 대기 중으로 방류된다. 이러한 이유로 국내 하수처리장에서는 강화된 방류수 수질 기준을 만족하기 하고자 유입수질에 관계없이 과도하게 송풍기를 운영하고 있다. 이러한 하수처리장의 운영 및 경제적인 문제점을 해결하고자, 본 연구에서는 하수처리장으로 유입되는 원수의 수질을 처리하는 데 실제로 미생물이 필요한 산소요구량 및 공기공급량을 산정하는 프로그램을 개발하였다. 이를 통해 실제 하수처리장에서 필요한 산소요구량, 공기공급량을 산출하여 효율적인 하수처리장 운영이 가능하다. 실제 하수처리장에서의 프로그램을 통한 송풍량 절감 효율을 분석하고자 한 달간의 A 하수처리장 수질 데이터를 기반으로 하수처리에 필요한 산소요구량 및 공기공급량을 산정하였다. 실험 결과 프로그램 적용시 약 평균적으로 10%의 송풍량을 절감이 가능하며, 연구 결과를 바탕으로 효율적이고 경제적인 송풍기 운영조건의 기준을 제시하고자 한다.

  • PDF