• Title/Summary/Keyword: Inflow noise

Search Result 67, Processing Time 0.031 seconds

AN APPROPRIATE INFLOW MODEL FOR SIMULTANEOUS DISSOLUTION AND DEGRADATION

  • Lee, Ju-Hyun;Kang, Sung-Kwon;Choi, Hoo-Kyun
    • Honam Mathematical Journal
    • /
    • v.31 no.1
    • /
    • pp.109-124
    • /
    • 2009
  • Based on the observed data for Clarithromycin released, three commonly used inflow models: the power, the exponential, and the logarithmic models are considered. Among them, the power model is used most in practice for simplicity. Using the numerical parameter estimation techniques, the parameters appeared in the model equations are estimated. Through the numerical estimation results using the several experimental data sets, the exponential model turns out to be best among the three models. More specifically, the sum of squares of absolute errors and the sum of squares of relative errors for the exponential model are reduced by 80-95 % for the experimental data sets and 60-90 % for the noise added data sets compared with those for the power and logarithmic models. A typical experimental data set is used in this paper to show the estimation method and its numerical results. The proposed numerical method and its algorithm are designed for estimating the parameters appeared in the model differential equations for which the exact form of the solution is unknown in general. The methodology developed can be applied to more general cases such as the nonlinear ordinary differential equations or the partial differential equations.

A Study on the Planning Guide of Educational Facilities for the Blind by the Cognition Characteristics and Wayfinding Behavior of the Blind - Focused on the Han-Vit and Seoul Educational Facilities for the Blind - (건축 공간인지 특성과 경로탐색(Wayfinding)을 고려한 맹학교 건축계획에 관한 연구 - 한빛맹학교와 서울맹학교를 중심으로 -)

  • Jung, Moo-Woong;Koo, Yang-Hoi
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.11 no.1
    • /
    • pp.25-37
    • /
    • 2004
  • This study is derived from a problem for the blind, how to recognize the space and how to find their way. Unlike ordinary people, the disabled people are closely related with special constructor environment using the other sense. Especially, to find his/her location, each person depends on the wayfinding ability as acquiring specific and various information,(e.g. recognizing figure by tactile sense, space size by auditory sense, direction by light from a window and regular noise, and existence of switch in a specific place.) Those senses help the person's wayfinding to his/her destination. The procedure of wayfinding are location, position, orientation, navigation, and movement. Consequently, construction for the people above mentioned can offer a design-guideline considering following factors, building arrangement considering regular noise, refurbishment, plan configuration of floor and wall-skin changed, circulation stream that maintains right angle by the regular noise in the building, enforcement location character by the inflow of the light into a crossing.

A Hybrid Audio ${\Delta}{\Sigma}$ Modulator with dB-Linear Gain Control Function

  • Kim, Yi-Gyeong;Cho, Min-Hyung;Kim, Bong-Chan;Kwon, Jong-Kee
    • ETRI Journal
    • /
    • v.33 no.6
    • /
    • pp.897-903
    • /
    • 2011
  • A hybrid ${\Delta}{\Sigma}$ modulator for audio applications is presented in this paper. The pulse generator for digital-to-analog converter alleviates the requirement of the external clock jitter and calibrates the coefficient variation due to a process shift and temperature changes. The input resistor network in the first integrator offers a gain control function in a dB-linear fashion. Also, careful chopper stabilization implementation using return-to-zero scheme in the first continuous-time integrator minimizes both the influence of flicker noise and inflow noise due to chopping. The chip is implemented in a 0.13 ${\mu}m$ CMOS technology (I/O devices) and occupies an active area of 0.37 $mm^2$. The ${\Delta}{\Sigma}$ modulator achieves a dynamic range (A-weighted) of 97.8 dB and a peak signal-to-noise-plus-distortion ratio of 90.0 dB over an audio bandwidth of 20 kHz with a 4.4 mW power consumption from 3.3 V. Also, the gain of the modulator is controlled from -9.5 dB to 8.5 dB, and the performance of the modulator is maintained up to 5 nsRMS external clock jitter.

DESIGN, CONSTRUCTION AND ACOUSTIC PERFORMANCE OF A SOUND-POOOF ENCLOSURE FOR DIESEL GENERATOR-SET

  • Bansal, A.S.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.662-667
    • /
    • 1994
  • This paper presents the design and construction details of a soundproof enclosure for housing 20 KVA diesel generator-set. As the generator had to be installed close to the hospital building, it was desirable to reduce the transmission of noise by housing the generator in such an enclosure. The diesel engine being an air cooled one, it was essential to supply fresh air into the enclosure for its cooling. Forced inflow of air is provided through an inlet duct located in such a way that the incoming fresh air is thrown close to the inlet of cooling fan of the engine. The high velocity air stream, which heats up while passing over the engine head, escapes to the atmosphere through a rectangular outlet duct with enlarges inlet that receives hot air from the engine. The air ducts were designed specially and have been provided with acoustic lining for sound absorption. The masonary enclosure has been provided with double glazed fixed windows and double doors. The exhaust pipe of the engine fitted with a muffler has been taken out through the enclosure wall facing away from the hospital. Acoustic performance studies conducted in terms of attenuation provided by the enclosure at different frequencies have also been presented and discussed. The noise control measures adopted for building the sound-proof enclosure have been found to be quite effective as the noise levels inside the hospital building are now within the acceptable limits.

  • PDF

Blade shape optimization of centrifugal fan for improving performance and reducing aerodynamic noise of clothes dryer (의류 건조기 성능 향상과 공력소음 저감을 위한 원심팬의 날개 형상 최적화)

  • Choi, Jinho;Ryu, Seo-Yoon;Cheong, Cheolung;Kim, Min-kyu;Lee, Kwangho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.3
    • /
    • pp.321-327
    • /
    • 2019
  • The purpose of this study is paper is to improve the flow performance and to reduce the aerodynamic noise of air discharge system consisting of a centrifugal fan, ducts and a housing for the clothes dryer. Using computational fluid dynamics and acoustic analogy based on FW-H (Ffowcs-Williams and Hawkings) Eq., air flow field and acoustic fields of the air discharge system are investigated. To optimize aerodynamic performance and aerodynamic noise, the response surface method is employed. The two factors central composite design using the inflow and outflow angles of fan blades is adopted. The devised optimum design shows the reduction of turbulent kinetic energy in the ducts and the housing of the system, and as a result, the improved flow rate and reduce noise is confirmed. Finally, the experment using the proto-type manufactured usign the optimum design shows the increase of flow rate by 4.2 %.

Forecast of the Daily Inflow with Artificial Neural Network using Wavelet Transform at Chungju Dam (웨이블렛 변환을 적용한 인공신경망에 의한 충주댐 일유입량 예측)

  • Ryu, Yongjun;Shin, Ju-Young;Nam, Woosung;Heo, Jun-Haeng
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.12
    • /
    • pp.1321-1330
    • /
    • 2012
  • In this study, the daily inflow at the basin of Chungju dam is predicted using wavelet-artificial neural network for nonlinear model. Time series generally consists of a linear combination of trend, periodicity and stochastic component. However, when framing time series model through these data, trend and periodicity component have to be removed. Wavelet transform which is denoising technique is applied to remove nonlinear dynamic noise such as trend and periodicity included in hydrometeorological data and simple noise that arises in the measurement process. The wavelet-artificial neural network (WANN) using data applied wavelet transform as input variable and the artificial neural network (ANN) using only raw data are compared. As a results, coefficient of determination and the slope through linear regression show that WANN is higher than ANN by 0.031 and 0.0115 respectively. And RMSE and RRMSE of WANN are smaller than those of ANN by 37.388 and 0.099 respectively. Therefore, WANN model applied in this study shows more accurate results than ANN and application of denoising technique through wavelet transforms is expected that more accurate predictions than the use of raw data with noise.

A Study on Indoor Environment Performances of Power Yacht in Summer Season (여름철 파워요트 실내환경 성능에 관한 연구)

  • Lee, Han-Seok;Doe, Guen-Young;Lim, Duck-Min;Kim, Hak-Chul
    • Journal of Navigation and Port Research
    • /
    • v.33 no.3
    • /
    • pp.175-180
    • /
    • 2009
  • In this study, the basic data were collected for improving the amenity of indoor environment of a super yacht and the performance of indoor environment was analyzed by utilizing measured data during summer period. Through the results of examination, the following conclusions are drawn. 1) It is estimated that, in case of closing the door of Saloon connected with outside, there is little inflow of exhaust gas, but when the door is open, the indoor-air might be polluted so fast. Therefore, it is necessary to make a counter plan about the method of ventilation and amount of ventilation to keep the indoor aerial environment agreeable. 2) It is urgent to conceive countermeasure against engine noise because the noise level of all rooms exceeds 60dB, which is regulation of noise for protecting crew established in ship's classification, during the sailing. 3) State cabin and Guest cabin are super cooled by operating air conditioner exceeding agreeableness extent and it is needed to prevent them.

Design of Door Seal Section with Optimal Reaction Force (최적반력을 가지는 도어 씨일의 단면설계)

  • 한근조;박영철;심재준
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.6
    • /
    • pp.165-175
    • /
    • 2000
  • In order to improve the function of a door seal, its section design technique is discussed in this study, Its roles are prevention of an inflow of dusts, noise interception, insulation, wateproof, and the vibroisolating action which reduces vibration between the body and the door of a car while running, and the buffer action which sustain the proper reacting force as the door is closed. In this study, the optimal cross section of a door seal is designed using nonlinear finite element analysis (commercial finete element analysis program EASi-SEAL) and tables of orthogonal arralys with respect to relations between door and door seal to secure the satisfactory airtight property with the minimum force to shut the door.

  • PDF

Experiment Study on Field Applicability of Siphon as a Intake Facility of Agricultural Reservoir for Disaster Prevention (재해대비 농업용저수지 취수시설로서 사이폰의 현장적용성에 관한 실험적 연구)

  • Yang, Young Jin;Lee, Tae Ho;Oh, Sue Hoon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.2
    • /
    • pp.103-110
    • /
    • 2018
  • Most of the intake facilities of small agricultural reservoirs are conduits and they are regarded as serious defects due to the structural weakness that penetrates the body of the dam, and countermeasures are needed. This study suggests the application method of siphon type water intake facility by hydraulic model test and physical scale model test of siphon type water intake facility which has high safety and easy maintenance. Experimental results show that sufficient flow rate can be secured for the purpose of intaking water according to the differential head between the reservoir and the discharge part, and the flow rate can be controlled by the valve. The negative pressure was -31.5 kPa, and vibration and noise did not occur during the operation of the siphon. The maximum flow velocity in the discharge outlet was 1.11 m/s which meets the criterion for irrigation canals. Therefore, scour risk would be very low. As a result of the inflow distribution experiment, even if the inflow part is separated by only about 0.8 m, the flow velocity is remarkably decreased, so that the clogging by debris would not appear. When the pump was operated only once for the first time and the inside of the siphon was filled with water, continuous operation was possible by only valve operation. The results of this study are expected to be used for the design guidelines of the water intake facilities and improve safety and maintenance convenience of agricultural reservoirs.

Improvement of sound insulation performance of windows according to the specifications of the external electric blinds (외부 전동블라인드의 사양에 따른 창호 차음성능 개선 효과)

  • Min-Woo, Kang;Hee-Dong, Lee;Yang-Ki, Oh
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.6
    • /
    • pp.621-628
    • /
    • 2022
  • The most realistic way to reduce noise outside the building, such as road traffic noise and aircraft noise, is to strengthen the sound insulation performance at the sound collecting points such as balconies, windows, and exterior walls of each building. However, in light of the reality that shading devices outside buildings are not yet widely used, there are not many studies on sound insulation performance improvement using external windows and window devices such as louvers and blinds. In particular, external blinds can not only block the inflow of strong sunlight in the morning and evening from the outside of the building, but also target the sound insulation effect that blocks the peak noise that occurs during commuting hours. In this study, a study was conducted to improve sound insulation performance against external noise by using an external electric blind (EEB), which is one of the most efficient window and door external shading devices. Various sound insulation performance tests were conducted while changing the configuration of external electric blinds developed for light blocking purposes. Through this, it was verified that an additional sound insulation performance of 6 dB can be obtained by installing an external electric blind compared to the reduction performance of general windows.