• Title/Summary/Keyword: Industrial disaster

Search Result 788, Processing Time 0.021 seconds

Evaluation of the Radiant Heat Effects according to the Change of Wind Velocity in Forest Fire by using WFDS (WFDS를 이용한 풍속에 따른 산림화재 복사열 강도 평가)

  • Song, Dong-Woo;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.1-7
    • /
    • 2013
  • The wildland fire intensity and scale are getting bigger owing to climate change in the world. In the case of domestic, the forest is distributed over approximately 63.7 % of country and the main facilities like a industrial facility or gas facility abuts onto it. Therefore there is potential that the wildland fire is developed to a large-scale disaster. In this study, the effect distances of the radiant heat flux from the crown fire are analysed according to the change of wind velocity. The safety criteria concerning the radiant heat flux to influence on the surrounding were researched to analyse the effect distances. The criteria of radiant heat flux were chosen $5kW/m^2$, $12.5kW/m^2$, $37.5kW/m^2$. WFDS, which is an extension of NIST's Fire Dynamics Simulator, was used to consequence analysis of the forest fire. In order to apply the analysis conditions, it is researched the forest conditions that is generally distributed in domestic region. As the result, the maximum effect distances by radiant heat were showed at the horizontal and vertical direction. When the wind velocity varied from 0 to 10 m/s, the maximum effect distance increased as the wind velocity increases. Interesting point is that the maximum effect distance were shown at the wind velocity of 8 m/s. The maximum effect distance was decreased according as the fuel moisture of trees increase. This study can contribute to analyse quantitative risk about the damage effect of the surrounding facilities caused by wildland fire.

Optimization of Water Reuse System under Uncertainty (불확실성을 고려한 하수처리수 재이용 관로의 최적화)

  • Chung, Gun-Hui;Kim, Tae-Woong;Lee, Jeong-Ho;Kim, Joong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.2
    • /
    • pp.131-138
    • /
    • 2010
  • Due to the increased water demand and severe drought as an effect of the global warming, the effluent from wastewater treatment plants becomes considered as an alternative water source to supply agricultural, industrial, and public (gardening) water demand. The effluent from the wastewater treatment plant is a sustainable water source because of its good quality and stable amount of water discharge. In this study, the water reuse system was developed to minimize total construction cost to cope with the uncertain water demand in future using two-stage stochastic linear programming with binary variables. The pipes in the water reuse network were constructed in two stages of which in the first stage, the water demands of users are assumed to be known, while the water demands in the second stage have uncertainty in the predicted value. However, the water reuse system has to be designed now when the future water demands are not known precisely. Therefore, the construction of a pipe parallel with the existing one was allowed to meet the increased water demands in the second stage. As a result, the trade-off of construction costs between a pipe with large diameter and two pipes having small diameters was evaluated and the optimal solution was found. Three scenarios for the future water demand were selected and a hypothetical water reuse network considering the uncertainties was optimized. The results provide the information about the economies of scale in the water reuse network and the long range water supply plan.

Effect of Food Waste Direct Landfilling Prohibition on Characteristics of Landfill Gas and Leachate (음식물류폐기물 직매립금지가 매립지 가스 및 침출수 특성에 미치는 영향)

  • Ko, Jae-Young;Phae, Chae-Gun;Park, Joon-Seok
    • Applied Chemistry for Engineering
    • /
    • v.18 no.6
    • /
    • pp.612-617
    • /
    • 2007
  • This research was performed to evaluate the effect of 'Food Wastes (FW) Direct Landfilling Prohibition' on characteristics of landfill gas (LFG) and leachate and the appropriateness of current legislation. Approximately 45% (Exp.45) and 15% (Exp.15) of FW were filled in two lysimeters. During 570 days, 1400 L of LFG was generated from Exp.45%, which was much more than 906 L of Exp.15. There was no significant difference of LFG composition between Exp.15 and Exp.45. 2~30 ppmv of odorous hydrogen sulfide was detected in Exp.45, while 2~7 ppmv was in Exp.15. There was also no significant difference in the leachate generation between the two. On day 570, $BOD_5$ of Exp.45 and Exp.15 were 37000 mg/Land 25630 mg/L and $COD_{Cr}$ of Exp.45 and Exp.15 were 45480 mg/L, 30294 mg/L. TOC of Exp.45 was 2~3 times higher than Exp.15. Higher portion of FW in landfilling increased LFG generation. However, it generated more odor and made the quality of leachate. Therefore, 'FW direct Landfilling Prohibition' was evaluated as an appropriate legislation.

Special Issue for the 30th Anniversary of the Korean Academy of Health Policy and Management (한국보건행정학회 30주년 기념 특별호)

  • Park, Eun-Cheol
    • Health Policy and Management
    • /
    • v.28 no.3
    • /
    • pp.195-196
    • /
    • 2018
  • The Korean Academy of Health Policy and Management (KAHPM) has shown remarkable achievements in the field of health policy and management in Korea for the last 30 years. The KAHPM consists of experts in various fields of health policy and management, and has been the leading academic discussion forum for health policy agendas of interest to the public. Health Policy and Management (HPM), the official journal of the KAHPM, published the first issue of volume 1 in October, 1991 and is publishing the second issue of volume 28 as of 2018. Currently, it is one of Korea' main journals in the field of health policy and management. HPM has published a special issue in commemoration of the 30th anniversary of the KAHPM. The HPM invited authors, including former presidents of the KAHPM and current board members, to write about main issues in health policy and management. Although the HPM tried to set up an invited author on all subjects in the health policy and management field, 19 papers are published, that completed the peer review process by August, 2018. The authors of the special issue of the 30th anniversary of the KAHPM include six former presidents, a senior professor, and 12 board members. The subjects of this issue are reform of the healthcare delivery system, health insurance and medical policy, reform of health system governance, the role of National Health Insurance Service (NHIS), the Korea Institute for Health and Social Affairs (KIHASA) and the National Evidence-based healthcare Collaborating Agency (NECA), ethical aspects of health policy change, regional disparities of healthcare, healthcare accreditation, new healthcare technology evaluation system, globalization of the healthcare industry, the epidemiological investigator system, the quarantine system, safety and disaster, and official development assistance. There are some remaining topics to deal with for the KAHPM: aged society, anti-smoking, non-infectious disease, suicide, healthcare resources, emergency medical care, out-of-pocket money, medical fee payment system, medical aid system, long-term care insurance, industrial accident compensation insurance, community-centered health welfare system, and central government and local government of health. The HPM will continue to publish review articles on the main topics in health policy and management. This is because the KAHPM, which has been the leading academic society of Korea's health policy and management for the last 30 years, feels responsible for continuing its mission for the next 30 years.

Development of Closed-loop Control Type FES System for Restoration of Gait in Patients with Foot Drop (족하수 환자의 보행보조를 위한 피드백 제어형 전기자극기 개발)

  • 정호춘;임승관;이상세;진달복;박병림
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.183-190
    • /
    • 1999
  • The purpose of this study was to develop a portable and convenient closed-loop contrel type electrical stimulator for patients with foot drop. This system restores walking movement as well as prevents from atrophy or necrosis of lower limb muscles and increases blood circulation in hemiplegic patients caused by traffic accident, industrial disaster or stoke. This system detects the changes of the ankle joint angle during walking, and then controls the stimulus intensity automatically to maintain the programmed level of the ankle joint angle. Also, this automatic system controls the stimulus intensity which is affected by increased electrode impedance resulting from long time use. The system detects the joint angle by an optical sensor and includes modified PID control which adjusts the stimulus intensity if the joint angle deviates from the preset value. Stimulus parameters are 30~80 volt, 40 Hz, and 0.2 ms. The system was applied to five hemiplegic patients for 42 days. Duration of stimulation was 15 min/day for the first week and then the duration was gradually increased to 30, 60, 90 and 120 min/day. The muscle force was increased up to 29.7%, muscle fatigue was decreased compared with the level before stimulation and the pattern of locomotion was improved. These results suggest that the electrical stimulator with closed-loop control type is more convenient and effective in restoration of locomotion of patients with foot drop than open-loop system.

  • PDF

Effects of NaCl/H3PO4 Flame Retardant Treatment on Lyocell Fiber for Thermal Stability and Anti-oxidation Properties (NaCl/H3PO4 내염화 처리가 라이오셀 섬유의 열 안정 및 내산화 특성에 미치는 영향)

  • Kim, Eun Ae;Bai, Byong Chol;Jeon, Young-Pyo;Lee, Chul Wee;Lee, Young-Seak;In, Se Jin;Im, Ji Sun
    • Applied Chemistry for Engineering
    • /
    • v.25 no.4
    • /
    • pp.418-424
    • /
    • 2014
  • The improved thermal stability and anti-oxidation properties of Lyocell fiber were studied based on flame retardant treatment by using NaCl/$H_3PO_4$ solution. The optimized conditions of flame retardant treatment were studied on various maxing ratio of NaCl and $H_3PO_4$ and the mechanism was proposed through experimental results of thermal stability anti-oxidation. The IPDT (integral procedural decomposition temperature), LOI (limited oxygen index) and $E_a$ (activation energy) increased 23, 30 and 24% respectively via flame retardant treatment. It is noted that thermal stability and anti-oxidation improved based on char and carbon layer formation by dehydrogenation and dissociation of C-C bond resulting the hindrance of oxygen and heat energy into polymer resin. The optimized conditions for efficient flame retardant property of Lyocell fiber were provided using NaCl/$H_3PO_4$ solution and the mechanism was also studied based on experimental results such as IDT (initial decomposition temperature), IPDT, LOI and $E_a$.

Policy Study on Appropriateness of Safety Check Costs in Construction Projects - Focusing on Industrial Safety and Health Act - (건설공사 안전점검대가의 적정성에 대한 정책적 고찰 - 산업안전보건법을 중심으로 -)

  • Kim, Byeong-Cheol;Lee, Dong Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.4
    • /
    • pp.747-757
    • /
    • 2017
  • Of safety check regulation, 'Construction Technology Promotion Act' and 'Special Act on the Safety Control of Public Structures' contain provisions about the content of safety in construction works and the items of safety checks in the maintenance aspect and thus contribute to accident prevention in the construction industry. Of the regulations responsible for the practical safety of workers, the safety check regulation of Ministry of Employment and Labor demand for safety check from the start of construction based on an agreement with a concerned agency to the completion of construction solely based on 'Guidance Standards for the Specialized Disaster Prevention Instruction in Article 32 of Occupational Safety and Health Act' and 'Appropriation and Usage Standards of Safety and Health Management Costs in the Construction Industry'. There is, however, a huge gap, as well, in them according to client agencies. In small construction sites ordered by a private organization, checks are done formally with no detailed regulations. As a result, the costs of checks continue to drop with only the contract kept intact. This study examined the forms of safety checks practically done in the Jeju region, distinguished and compared them by the construction costs, calculated proper costs based on each construction act, and further proposed improvement measures for the detailed regulations.

Longitudinal Change in Health Status after the Sewol Ferry Accident among Bereaved Parents (세월호 참사 후 희생자 부모의 건강상태 변화)

  • Yang, Sang Eun;Tae, Hye Jin;Hwang, Jihyun;Chae, Jeong-Ho
    • Anxiety and mood
    • /
    • v.14 no.1
    • /
    • pp.44-52
    • /
    • 2018
  • Objective : The present study had examined the psychiatric symptoms and physical health consequences for the bereaved parents of the high school students who died in the 2014 Sewol ferry accident. Methods : Forty bereaved parents participated in the study. The authors administered self-report questionnaires about the parents' health behaviors and psychiatric symptoms. The authors also conducted laboratory tests to assess the parents' physical health at 18 and 30 months after the accident. Univariate descriptive statistics were performed to report the prevalence and severity of psychiatric symptoms and health-related behaviors. Paired t-test and Mcnemar test were performed to compare the 18-and 30-month findings. Correlation analysis between psychiatric symptoms and laboratory findings were performed to find a relationship between the two variables. Results : At 30 months after the accident, most of the bereaved parents still appeared to suffer from complicated grief (97.5%), post traumatic stress disorder (80%), insomnia (77.5%) and severe depression (62.5%) based on the scores on the Inventory of Complicated Grief (ICG), the PTSD Check List-5 (PCL-5), the Insomnia Severity Index (ISI) and the Patient Health Questionnaire-9 (PHQ-9). One quarter of the bereaved parents reported high-risk drinking, and 47.5% reported increased drinking amount and frequency after the accident. In objective laboratory results, 55% of the bereaved parents were obese as defined by body mass index ${\geq}25$. The parents' mean low-density lipoprotein shows a significant increase over time (118.5 mg/dL at 18 months. vs. 132.5 mg/dL at 30 months. paired t-test t=-4.061, $$p{\leq_-}0.001$$). Total cholesterol and low-density lipoprotein at 30 months after the accident were in clinically borderline high range. In correlation analysis, triglyceride was positively correlated with ISI. Conclusion : The loss of children in the Sewol ferry accident, a disaster caused by human error, continued to have considerable impact on the victims' parents' mental and physical health 18 and 30 months after the accident. A longitudinal study following the parents' physical health would be necessary to investigate the long-term effects of this traumatic experience on physical health.

Effects of Metal Oxide Addition on Co-pyrolysis of PVC and ABS Mixtures (PVC와 ABS 혼합물의 공열분해에 대한 금속산화물의 첨가 효과)

  • Kim, Hee Taik;Choung, Youn Wook;Lee, Hae Pyeong
    • Applied Chemistry for Engineering
    • /
    • v.16 no.2
    • /
    • pp.296-303
    • /
    • 2005
  • The co-pyrolysis characteristics of polyvinylchloride (PVC) and acrylonitrile butadiene styrene (ABS) mixtures with various mixing ratios and effect of addition of CaO and $Cu_2O$ have been studied using thermogravimetry (TG) and gas chromatograph-mass spectrometry (GC-MS). In an isothermal decomposition conducted at $500^{\circ}C$, the yields of styrene monomers and aromatic compounds increased as the mixing ratio of ABS increased, and the yield of BTX compounds reached its maximum (16.14%) when the mixing ratios of PVC and ABS was 4:1. In an isothermal decomposition added with metal oxides, the maximum yield of liquid product was 73% when CaO [CaO/(PVC+ABS)=0.4] was added and it was 70% when $Cu_2O$ [$Cu_2O$/(PVC+ABS)=0.4] was added, respectively, where HCl contained in the gaseous product was completely removed when added with CaO [CaO/(PVC+ABS)=0.5] and $Cu_2O$ [$Cu_2O$/(PVC+ABS)=1.0]. Therefore, to obtain the highest yield of liquid product it appears to be the reaction condition: the reaction temperature of $500^{\circ}C$ and mixing ratios of CaO and $Cu_2O$ are 0.5 and 1.0, respectively.

Research on Digital twin-based Smart City model: Survey (디지털 트윈 기반 스마트 시티 모델 연구 동향 분석)

  • Han, Kun-Hee;Hong, Sunghyuck
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.11
    • /
    • pp.172-177
    • /
    • 2021
  • As part of the digital era, a digital twin that simulates the weak part of a product by performing a stress test that reduces the lifespan of some expensive equipment that cannot be done in reality by accurately moving the real world to virtual reality is being actively used in the manufacturing industry. Due to the development of IoT, the digital twin, which accurately collects data collected from the real world and makes it the same in the virtual space, is mutually beneficial through accurate prediction of urban life problems such as traffic, disaster, housing, quarantine, energy, environment, and aging. Based on its action, it is positioned as a necessary tool for smart city construction. Although digital twin is widely applied to the manufacturing field, this study proposes a smart city model suitable for the 4th industrial revolution era by using it to smart cities and increasing citizens' safety, welfare, and convenience through the proposed model. In addition, when a digital twin is applied to a smart city, it is expected that more accurate prediction and analysis will be possible by real-time synchronization between the real and virtual by maintaining realism and immediacy through real-time interaction.