• Title/Summary/Keyword: Industrial Noise

Search Result 1,261, Processing Time 0.038 seconds

Review of Measurement of Sound Insulation in Buildings and of Building Elements Using Sound Intensity : Laboratory Conditions (Sound Intensity를 이용한 건물부재의 차음성능 실험실 측정방법 고찰)

  • Jung, Sung-Soo;Kook, Chan;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1138-1141
    • /
    • 2002
  • In this study, the ISO 15186-1 “Measurement of sound insulation in buildings and of building elements using sound intensity - Part 1 : Laboratory conditions” was reviewed in order to make it as a new Korean Industrial Standard. Several main contents are discussed.

  • PDF

A Study on Application of Vibration Testing Method (진동 시험 기법의 적용에 관한 고찰)

  • Lee, Chang-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.587-591
    • /
    • 2012
  • Review of practical vibration test methods those applied in various industrial fields - such as automotive industry, electrics and electronics industry, defense industry and aerospace industry - is described on this paper. Swept sine test, random vibration test and advanced vibration techniques are explained according to their parametric values and also application fields of each test method are suggested by the characteristic of each method. For more proper application of each test method, standardized test specifications should be always reviewed and revised according to the transition of environmental factors.

  • PDF

Investigation on the EMI Noise Reduction of LED Lighting Module in Hospital (병원내 LED 조명기구의 전자파 저감대책)

  • Song, Min-Jong;Cho, Hyun-Seob
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.385-388
    • /
    • 2011
  • The electromagnetic wave occurs primarily LED lighting equipment in the interior medical imaging information a lot of high-frequency equipment environment installation. It generated by lighting fixtures mach damage to patients as well as non or no operation. It can be reduced through noise attenuation and filter change. It associated with the capacitors and inductors can reduce by are used frequency efficiently, Attenuation circuit does not significantly affect the radiation medical equipment devices

  • PDF

A Study on the Korea Industrial Standardization of ISO 9053 (공기흐름저항(ISO 9053)의 KS 규격 제정에 관한 연구)

  • Jung, Sung-Soo;Kook, Chan;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.984-985
    • /
    • 2004
  • The ISO 9053, acoustics - materials for acoustical applications - determination of airflow resistance was reviewed in order to make it as a KS and the basic contents were introduced. The measurement apparatus according to ISO 9053 were made and tested.

  • PDF

Measurement of Magnetostriction Characteristics of Electrical Steel Sheet using Three-axial Strain Gauge and Vector Single Sheet Tester (3축 Strain Gauge와 Vector Single Sheet Tester를 이용한 전기강판의 자왜 특성 측정)

  • Park, Chan-Hyuk;Cho, Hyun-Jin;Yoon, Hee-Sung;Ha, Jung-Woo;Kim, Joong-Kyoung;Koh, Chang-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.8
    • /
    • pp.1039-1045
    • /
    • 2014
  • Acoustic noise from a transformer, recently, has drawing more and more attentions. One of the main source of the noise is thought to be magnetostriction of the electrical steel sheets which compose transformer core. This paper deals with the magnetostriction of a highly grain-oriented electrical steel sheet measured by using a vector single sheet tester and a three-axial strain gauge. The results show that direction and axis ratio as well as the magnitude of the applied magnetic flux density contribute much to magnetostriction.

A Study on Office Environment Satisfaction and Worker's Subjective Symptoms

  • Jeong, Byung Yong;Shin, Dong Seok;Park, Myoung Hwan
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.3
    • /
    • pp.223-234
    • /
    • 2015
  • Objective:This study aims to investigate the correlation between office environment satisfaction levels and workers' subjective symptoms by conducting surveys asking office workers to state their subjective symptoms and office satisfaction levels. Background: The increased number of office workers and their work hours have led to new understandings of the importance of office environments including its temperature, humidity, noise levels, lighting, space arrangements, and quality of air. Method: Specific details on office work, office environment, office space satisfaction levels, workplace related symptoms, absence from work, due to workplace-related symptoms, were analyzed based on the survey answers given by 451 office workers who were the subjects of this research. Results: Office workers showed different characteristics of subjective symptoms depending on their gender, age, work experience, and time spent resting and on computers. Also, differences in symptoms were found for workers with different satisfaction levels for office environment (temperature, humidity, noise levels, quality of air, lighting) and office space arrangements (location of monitors, area and display of office space, chairs and desks). Conclusion and Application: Relationship between workers' satisfaction levels with the office environment and their subjective symptoms is expected to be serve as essential data for systematic management of the workplace.

Modification of the Porosity of the Perforated Plate for the Improvement of Acoustic Attenuation Performance for Muffler (머플러의 소음성능 향상을 위한 다공판 공극률의 설계변경해석)

  • Bae, Kyeong-Won;Park, Jeong-Pil;Jeong, Weui-Bong;Ahn, Se-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.2
    • /
    • pp.83-89
    • /
    • 2015
  • The transmission loss(TL) has been widely used as the acoustic performance index of industrial mufflers. Industrial mufflers usually consist of several partitions with perforated plate. In this study, firstly, the computational model for a typical industrial muffler was performed and validated by comparing with the experimental results. Secondly, the effects of the porosity of the perforated plates on the acoustical TL were investigated and the database of the tendencies were set up. Finally, on the basis of these tendencies, the modified muffler with better TL than conventional one could be suggested.

Design and Planning Criteria for the Green Buffer Zone (환경친화적 완충녹지의 기준설정)

  • 박은영;유병림
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.32 no.2
    • /
    • pp.25-35
    • /
    • 2004
  • The purpose of the study is to analyze the existing situation of the green buffer zone in the large scale industrial site and other major residential apartment areas. In this study, it is specifically intended that the planning guideline be upgraded to adopt future landuse trends and thus to suggest design criteria for management of the buffer zone. The framework of the analysis is to review the current landuse, noise reduction, ecological implications and landscape in general. Although the major function of a green buffer zone is considered to protect the residential area from various hazards of industrial, traffic, and visual environment, the situation is that most of the zones are maintained at a minimum level of services by local government. The study carried out intensively almost every type of case studied throughout the country, which implies that the management of the green buffer zone should be expanded physically enough to function for its original objectives. The study recommends that ecological management of the green buffer zone be emphasized and therefore the criteria for this purpose as well as noise issue should be developed prior to the landuse aspects. The study suggests specific guidelines for planning and design for the green buffer zone development. This study should be verified positively through the sustainable monitoring and requires nationwide and overall examination so that it may be applied to whole green spaces.

Development of a diverging collimator for environmental radiation monitoring in the industrial fields

  • Dong-Hee Han;Seung-Jae Lee;Jang-Oh Kim ;Da-Eun Kwon;Hak-Jae Lee ;Cheol-Ha Baek
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4679-4683
    • /
    • 2022
  • Environmental radiation monitoring is required to protect from the effects of radiation in industrial fields such as nuclear power plant (NPP) monitoring, and various gamma camera systems are being developed. The purpose of this study is to optimize parameters of a diverging collimator composed of pure tungsten for compactness and lightness through Monte Carlo simulation. We conducted the performance evaluation based on spatial resolution and signal-to-noise ratio for point source and obtained gamma images and profiles. As a result, optimization was determined at a collimator height of 60.0 mm, a hole size of 1.5 mm, and a septal thickness of 1.0 mm. Also, the full-width-at-half-maximum was 3.5 mm and the signal-to-noise ratio was 53.5. This study proposes a compact 45° diverging collimator structure that can quickly and accurately identify the location of the source for radiation monitoring.