A Study on Noise Reduction for the Driving System of a Forklift (지게차 구동부의 소음 진동 저감에 대한 연구)

  • Kim, Woo-Hyung;Hong, Il-Hwa;Chung, Jin-Tai
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.1
    • /
    • pp.80-86
    • /
    • 2008
  • In this study. the noise sources were identified and the noise and vibration were reduced for an industrial forklift. To identify the noise sourses, noise signals were measured by a microphone on a driver seat and these signals were analyzed with a waterfall plot. For this purpose, the gear mesh frequencies from the gear box of a reducer were not only investigated but noise/vibration sourses of an electric motor were also examined. Furthermore, the frequency response functions were obtained to confirm the vibration and noise sourses. It was found that severe vibration and noise were generated in the casing and the connecting part of the reducer. The severe vibration and noise could be reduced by a structure modification.

Typicality of Vocabulary for evaluation on Instrument-Noise generated at Loud Noise Workplace (고소음 작업장에서 발생하는 기기소음 평가를 위한 어휘의 유형화)

  • Ju, Duck-Hoon;Kook, Jung-Hun;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.242-247
    • /
    • 2007
  • After the Industrialization of 1960s, while it has greatly contributed to the industrial development owing to acceleration of mechanization, but it is real situation that the countermeasure to Noise Damage generating at the loud noise workshop is scarcely made. Especially, the Instrument-Noise made at factory and workplace is so shocking and repeatedly reiterating terrible noise that most of the spot workers are forcedly imposing such dangers as the severe unpleasant feeling and hearing impairments. On such point of view, this Research has attempted to extract the proper Rating Vocabulary in order for valuation on Instrument Noise made at the terrible noise-workplace, therefore it is considering that those extracted Vocabularies could be utilized as the useful materials for appraisal on Instrument Noise, also for establishment of Regulation-Standard with regard to Acoustic Psychology Experimentation and Instrument Noise.

  • PDF

A Study on the Vertical SPL of Railway Noise by Noise Barrier (방음벽 설치에 따른 철도소음의 수직음압레벨 분포특성에 관한 연구)

  • 윤해동;윤희경;김재수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1099-1103
    • /
    • 2002
  • With rapidly industrial development, a railway has become of a main traffic means. But, the railway noise has caused much annoyance for the residents living nearby railway tracks. Therefore, in our country, for established of quite dwelling environment. execute regulation standard of railway noise from January 1. 2000. Efficiency soundproofing measures, however, are very difficult because of the lack of basic data and insufficiency of the existing research. In this point. this study attempts to survey the vertical sound pressure level of railway noise in by existence of noise harrier And this study intends to get the basic data for establishment of a efficient noise barrier about railway noise.

  • PDF

An Investigation on Influence of Vibration Noise in Cooling Tower on Precision Equipments (산업용 냉각탑의 진동소음이 정밀장비에 미치는 영향에 대한 연구)

  • Lee, Jin-Kab
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.369-374
    • /
    • 2016
  • Cooling towers have been installed on rooftops or outside of buildings and widely applied to control the indoor temperature in residential areas and buildings. However, the noise and vibration resulting from their operation may cause problems in adjacent buildings. The purpose of this study is to measure the noise and vibration of an industrial cooling tower located adjacent to industrial plants and to investigate its influence on the surroundings according to an authorized evaluation standard. Further, in order to measure the effect of the vibration of the tower on the precision equipment inside the plant, an experiment is conducted to measure the vibration of the ground in the plant and the targeted precision equipment. The measurement results indicate that the noise in the cooling tower is 4 to 9 dB(A) higher than the maximum level defined in the standard of 68dB(A). The effect of the vibration of the tower on the precision equipment is comparatively minimal, because that in the supporting frame of the building is weaker than that on the floor where the precision equipment is located. The vibration of the floor on.

Comparison Research of SNR and SRb with Bright Calibration and Multi Frame Images in Digital Radiography of Welded Test Components (용접 시험편의 디지털 방사선 검사에서 밝기 교정과 중첩 영상에 따른 SNR 및 SRb 비교 연구)

  • Nam, Mun-Ho;Yang, Jin-Wook;Cho, Kap-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.731-739
    • /
    • 2021
  • This work compared the bright calibration of digital radiation with signal-to-noise ratio and basic spatial resolution according to multi frame to enable effective inspection of welding parts of structures at industrial sites. A total of 130 images were obtained by using a 75Se radiation source for flat weld test pieces and segmenting bright calibration and multi frame prior to shooting. The study confirms that the signal-to-noise ratio improves as the number of bright calibrations and the number of multi frame increases. The basic spatial resolution satisfied the baseline for both radiographic images. It was confirmed that the number of signal-to-noise ratio was similar by comparing images taken after installing lead shielding for scattering radiation. Although signal-to-noise ratio increases as multi frame increases, it is believed that good quality digital radiographs can be obtained if appropriate radiographic techniques are devised because exposure time of radiation affects workers' exposure and work efficiency.

Noise Lowering for a Large Variable Speed Range Use Permanent Magnet Motor by Frequence Shift and Structural Response Evaluation of Electromagnetic Forces

  • Arata, Masanori;Takahashi, Norio;Fujita, Masafumi;Mochizuki, Motoyasu;Araki, Takashi;Hanai, Takashi
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.67-74
    • /
    • 2012
  • According to electrical output up rating of a permanent magnet motor and request to operate for a large variable speed range, resonance between structural natural vibration and electromagnetic force inside the motor can take place and make noise. This paper describes the mechanism of a resonance between them and noise lowering procedure by frequency shift when they are applied to the reluctance torque largely employed new motor named Permanent magnet Reluctance Motor (PRM).

Analysis of Randomness Characteristics of Hardware Noise Generator (하드웨어 잡음발생기의 랜덤 특성 분석)

  • Hong, Jin-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.263-267
    • /
    • 2011
  • This paper analyzed randomness characteristics of output data in generator based on hardware noise source. Also it is enhanced security randomness in the output stream of generator, which is applied on Laplacian filter. First it reviews criteria of randomness verification of output stream of hardware noise generator, and presents the enhanced results of output stream of generator, which is applied on Laplacian filter.

An Experimental Study on the Performance Improvement of Industrial Blower Silencer (산업용 송풍기 소음기의 성능개선을 위한 실험적 연구)

  • Kim, B.S.;Kim, Yong-woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.9 s.102
    • /
    • pp.1060-1069
    • /
    • 2005
  • Silencers are engineering devices that are designed to attenuate sound waves propagating in a flowing medium. The muffler type silencer has a series of chambers in parallel or series utilizing the reflection and expansion characteristics of the expansion chambers, sidetubes, branch resonators, and tailpipes to attenuate the sound. To Improve the performance of industrial blower silencer of muffler type which is employed in petrochemical plant, this paper seeks its optimal arrangement of buffs by experimental method and suggests optimal arrangement of buffs. Experimental results show that the optimal one suggested can reduce the noise level as much as 14 dB (or 18 dB(A)) in the laboratory and as much as 4 dB(A) compared to that of the existing silencer on the ground.