도로터널에서 제트팬 근처의 재순환유동과 연기 역류현상의 상호작용 분석 (Analysis of Interaction Between Recirculating Flow Near The Jet Fan and The Backlayer of Smoke in a Road Tunnel)

  • 김창균;유진웅;김성준
    • 산업기술연구
    • /
    • 제25권A호
    • /
    • pp.191-201
    • /
    • 2005
  • A numerical analysis was done for a tunnel fire in a 1000m road tunnel. A cartesian coordinate was adopted to make a computational grid sytem which has 448,000 computational cells. A transient flow phenomena in the tunnel was simulated by the commercial code of PHEONICS from the ignition of fire to 600 seconds by the interval of 100 seconds. Total computational time of about 44 hours was required to get a convered solution in each time step. The purpose of this research is to analyze of the backlayering pheonomena and recirculation flow in a tunnel. The compuational results say that the backlayering does not happens near the fire of vehicle in this case because the vehicle fire is located at the outside of recirculation zone of flow ocuured near the jet fan. In this research, onset of backlayering pheonomena could be escaped if jet fan is set 95m in front of the the fire of vehicle.

  • PDF

냉방용 팬코일 유닛 열교환기의 열전달 및 압력강하 특성 실험연구 (Experimental Study on Heat Transfer and Pressure Drop of Heat Exchangers for Cooling Fan Coil Unit)

  • 권영철;고국원;권정태
    • 한국산학기술학회논문지
    • /
    • 제9권3호
    • /
    • pp.599-604
    • /
    • 2008
  • 본 연구에서는 냉방운전 시에 팬코일 유닛에 사용되는 핀-관 열교환기의 공기측 열전달 능력과 압력강하를 실험을 통하여 조사하였다. 실험을 위하여 칼로리미터와 항온수조를 이용하였다. 사용된 핀은 슬릿핀이며 5종 열교환기에 대해 배관회로와 실험조건을 변화하면서 실험하였다. 공기-물 정격유량에서의 냉방능력은 열교환기 공급 물온도가 낮은 조건이 우수하였으며, 배관회로에 따른 냉방능력은 배관 내 물흐름이 U형보다 ㄹ형인 경우에 더 크게 나타났다. 물유량이 증가할수록 냉방능력은 일정비율로 증가하였으며, 열교환기 공급 물 온도가 낮을 때 우수하였다. 공급 물 온도가 낮은 조건에서 많은 응축수가 생성되어 공기측 압력강하는 크게 나타났다.

ANSI/AMCA 210 기준에 의한 대형 축류 송풍기의 성능시험 및 측정 불확도 평가 (An Estimation of Performance Test and Uncertainty of Measurement for a Large Axial-flow Fan Based on ANSI/AMCA 210 Standard)

  • 고희환;정철영;김경엽
    • 한국유체기계학회 논문집
    • /
    • 제17권2호
    • /
    • pp.24-29
    • /
    • 2014
  • In general, a large-capacity axial flow fan is used for industrial processes or ventilation in a social overhead capital infrastructure. The main characteristics of the large axial-flow fan need a lot of electrical power consumption and operate 24 hours a day, 365 days a year. Since the large axial flow fan consumes several hundreds to thousands kW per hour, both manufacturer and consumer are struggling to select high efficiency products for saving energy and reducing operation cost. Therefore, the performance testing should be accurately conducted in experimental equipments. The performance estimation and uncertainty of measurement of the axial-flow fan gathered from the result from nozzle shaped testing equipments certified with ANSI/AMCA standard and duct shaped testing equipment under the same experimental condition. The experimental results from both facilities have maximum 17% differences in performance evaluation and uncertainty of measurement. As considering that the differences, it is doubt about the reliability of testing result. The test was repeated with the specific term during 12 months because it is important to fully reflect the real conditions and to decide the repeatability of data. The evaluation of duct type testing facilities was failed to get an uncertainty measure. Testing results were previously published. As a series of previous paper, axial fan (∅1690 mm) and duct type testing facilities were fabricated. The purpose of fabricating testing equipment was testing an uncertainty measurement under the controlled environments.

프로야구 팬의 팀 동일시에 영향을 미치는 요인에 관한 연구: 응원시작 연령의 효과를 중심으로 (A Study on the Determinants of Fans' Team Identification in KBO League : Focused on the Effects of Kids Marketing)

  • 최승년
    • 한국산학기술학회논문지
    • /
    • 제17권1호
    • /
    • pp.99-110
    • /
    • 2016
  • 본 연구의 목적은 국내 프로야구 팬들이 갖는 팀 동일시에 영향을 미치는 요인을 개인 요인, 경기 요인, 경기외적 요인으로 구분하여 종합적으로 분석하는 것이다. 이를 위해 2015년 9월 중 수도권 및 지방에 소재한 3개 야구장을 방문하여 편의표본추출법에 의해 총 297부의 설문지를 수집하였으며, 다중회귀분석을 통하여 구체적인 영향력을 파악하였다. 본 연구에서 가장 관심을 갖는 것은 개인 요인으로, 특정 팀에 대한 응원을 시작한 시기가 유소년기 이전일 경우 팀 동일시에 더욱 강한 영향을 미칠 것이라는 가설을 검증하였다. 그 밖에 세 개의 경기 요인과 네 개의 경기외적 요인을 설정하고 응원시작연령과 경기 요인들 간, 그리고 응원시작연령과 경기외적 요인들 간의 교호효과를 분석하였다. 이를 통해 매우 흥미로운 결과가 도출되었는데, 유소년 기에 응원을 시작한 팬들이 그렇지 않은 팬들에 비해 확연하게 강한 팀 동일시 정도를 나타낸다는 것이다. 또한 이 경우 선수 요인이 팀 동일시에 미치는 긍정적 영향을 더욱 강화하는 것으로 밝혀져, 교호효과 역시 일부 존재하는 것으로 분석되었다. 경기 요인과 경기외적 요인 중에서는 선수, 판촉 및 팬 서비스, 가격, 연고지 요인이 팀 동일시에 긍정적인 영향을 미치는 것으로 분석되었다. 본 연구는 기존에 거의 시도되지 않았던 스포츠 산업에서의 아동마케팅의 효과를 실증 분석함으로써 이론적 발전에 기여함은 물론 프로구단으로 하여금 보다 강력한 유소년 마케팅 정책을 펼치도록 하는데 도움을 주는 전략적 시사점을 제공했다는 데에서 의의를 찾을 수 있다.

PVC압출공정의 염화비닐 발생특성과 작업환경개선에 관한 사례연구 (A Case Study on the Release Characteristic and Removal Efficiency of Vinyl Chloride in the Poly Vinyl Chloride Extrusion Process)

  • 박동욱
    • 한국산업보건학회지
    • /
    • 제3권1호
    • /
    • pp.91-98
    • /
    • 1993
  • This study was carried out to investigate characteristic of vinyl chloride emissioned from poly vinyl chloride extrusion process and to evaluate the efficiency of local exhaust ventilation system. Before local ventilation facility was constructed in poly vinyl chloride extrusion process, the average worker exposure to vinyl chloride was 3.15 ppm, which exceeded Threshold Limit Value of American Conference of Gorvernmental Industrial Hygienists (ACGIH-TLV), 1 ppm. lt is possible that vinyl chloride residues in the poly vinyl chloride resin was released or degased due to extrusion heat. The larger the width of vinyl tube become, the higher worker exposure to vinyl chloride was. It is estimated that vinyl chloride from vinyl chloride resin increased as amount of poly vinyl chloride resin extruded in the extrusion process increased. Canopy hood was an appropriate type for poly vinyl chloride resin extrusion process. This local exhaust ventilation has fan static pressure of 7.65 inch wg($190mmH_2O$, total volumetric flowlate of 4,796 CFM ($135.8m^3$/min) and fan power requirement of 12 hp (8.952 Kw). After this local exhaust ventilation was constructed there, the average concentration of worker exposure to vinyl chloride was reduced to be 0.46 ppm, which was below the Threshold Limit Value, 1 ppm. Also, the removal efficiency rate of vinyl chloride attained by local exhaust ventilation was 85.3%. It was a statistically significant (p<0.01).

  • PDF

에어컨 실외기용 축류홴의 성능에 관한 연구: 소음 특성 (Analysis on Performance of Axial Flow Fan for Outdoor Unit of Air-conditioner: Noise Characteristics)

  • 김용환;이장호
    • 한국유체기계학회 논문집
    • /
    • 제13권5호
    • /
    • pp.29-34
    • /
    • 2010
  • In this paper, aerodynamic noise of axial flow fans for outdoor unit of air-conditioner was analyzed by both experiment and numerical simulation. The three-dimensional incompressible turbulent flow was predicted by the commercial computational fluid dynamics code SC/Tetra, while the aeroacoustic noise of an axial flow fan was predicted by FlowNoise. Computations and experiments were performed with two types of axial flow fans, in which very different noise source distributions were presented. The results obtained from this study are expected to show the way to reduce the noise of axial flow fans in industrial applications.

회전체 진동으로 인한 판넬 방사소음의 실험적 기여도 분석 (An Experimental Analysis of the Contributions to the Radiated Noise due to Panel Vibration of a Rotational Machine)

  • 국형석;허승진;고강호
    • 한국소음진동공학회논문집
    • /
    • 제13권2호
    • /
    • pp.126-131
    • /
    • 2003
  • This study is concerned with the reduction of noise radiation by an industrial fan unit. First, spectral decomposition method is used to decompose the spectrogram obtained in experiments into source function and noise transfer function, and then major noise generation sources are investigated. Among the noise sources involved in the fan unit. this article is focused on the noise source due to vibration of panels of the unit housing. It is shown here that noise radiation associated with the panel vibration can be as significant in some frequency ranges as that associated with other noise sources such as aeroacoustic fan noise.

산업용 유량제어 송풍기 베인댐퍼 개발에 관한 연구 (A Study on Development of Vane Damper for Industry Flow Control Fan)

  • 이중섭;정인국;윤지훈;서정세;장성철
    • 한국생산제조학회지
    • /
    • 제21권1호
    • /
    • pp.137-143
    • /
    • 2012
  • In this study, it was conducted to design each components of vane damper for industrial flow control fan and the flow rates were analysed by experimental and numerical method. Through environmental test, it could be confirmed that the designed vane damper was appropriate. Also, almost identical results with test could be drawn from numerical method. Finally, flow rates of electric and pneumatic actuator were measured by test. As the results, difference of flow rate according to opening ratio was smaller in pneumatic actuator than that in electric actuator.

드라마 콘텐츠의 리드 유저 기반 틈새 창출(niche creation) 메커니즘 연구 - 드라마 다모(茶母) 팬덤 커뮤니티를 중심으로 (The Study on niche creation mechanism of drama contents based on lead users - Focussing on drama Damo fandom community)

  • 장용호;공병훈
    • 한국산학기술학회논문지
    • /
    • 제14권5호
    • /
    • pp.2121-2130
    • /
    • 2013
  • 본 연구는, 팬덤 커뮤니티의 창작과 생산을 통해 부상하는 무수한 UCC 클라우드(cloud)가 리드 유저에 의한 틈새 창출 과정임을 드라마 다모의 커뮤니티를 사례를 통해 실증적으로 분석하였다. 연구 결과, 첫째, 드라마 애호가와 팬픽션 작가들은 드라마 소비자들이자 UCC 창작/생산자로서 팬덤 커뮤니티에서 자신들의 니즈에 맞는 사용자 맞춤형 콘텐츠인 UCC와 팬픽션을 만드는 과정을 통해 원작 드라마와는 전혀 다른 틈새를 창출한다. 둘째, 커뮤니티의 크리에이티브 유저들이 만드는 드라마에 대한 소비/평가, 시청자 요구/적응, 유저의 창작/생산이라는 순차적인 흐름은 드라마 정보를 제공하고 의도적으로 자원을 공급/확산시키며 파생 상품을 생산하는 미디어 기업의 흐름과 상호작용하는 공진화(coevolution) 관계를 보여준다. 셋째, UCC와 팬픽션을 둘러싼 드라마 팬덤 커뮤니티의 활동은 드라마에 대한 재미와 놀이 그리고 공감을 넘어 지식이 투입되는 창작과 생산의 결과물을 통해 비상업적 활동이 시장과 지속적으로 연계되어 선순환되는 새로운 패러다임의 드라마 생태계를 형성하고 있다.

친환경 에너지 절감형 전기온풍기 기구설계 (Electric Fan Heater Design for Eco-Energy Saving)

  • 설용태
    • 한국산학기술학회논문지
    • /
    • 제17권4호
    • /
    • pp.474-479
    • /
    • 2016
  • 친환경에너지에 대한 요구가 높아지면서 전기에너지의 사용은 계속 증가하고 있다. 최근 친환경, 에너지 절약을 위해서 유도가열을 이용한 여러 가지 가열방식에 대한 관심이 높아지고 있다. 본 논문에서는 전자유도현상을 이용한 유도가 열방식을 이용하여 보다 친환경적이고 에너지 절약이 가능한 전기온풍기를 설게 제작하였다. 온풍기는 송풍부, 유도가열부 및 전력변환부 등 3부분으로 구성하였다. 유도가열부는 송풍부에 결합되어 송풍부로부터 발생된 바람이 가열되어 분출되며, 전력변환부는 고주파를 인가하여 자속을 발생시킴으로써 유도가열부의 내부를 가열시킨다. 발열방식은 유도가열의 원리를 적용하고, 전력변환효율성을 높이기 위해 공진형 인버터를 사용하였다. 공진형 인버터는 풀브리지 전압형 직렬부하 공진형 인버터를 사용하였다. 유도가열부는 세라믹 계열의 절연체와 SUS40계열의 금속체를 사용했으며, 전력변환부는 정류부, 필터부 및 공진형 인버터부 등으로 구성 하였다. 본 연구에서 제안한 전기온풍기는 기존의 전기히터와 가스히터 등과 비교한 결과, 온도 상승속도가 빠르고, 사용에너지 비용이 절감되는 등 경제성도 있음을 보였다. 개발된 전기온풍기는 가정용, 상업용 및 농업용 등 여러 분야에 친환경 에너지절감형 온풍기로의 적용 가능성이 있다.