• Title/Summary/Keyword: Industrial Control Systems

Search Result 2,566, Processing Time 0.03 seconds

Design and Implementation of Rate-Based Traffic Controller for Performance Improvement of FA-Networks Employing LonWorks (LonWorks를 이용한 공장자동화용 네트웍의 성능향상을 위한 전송률기반 트래픽제어기의 설계와 구현)

  • Kim, Byoung-Hee;Cho, Kwang-Hyun;Park, Kyoung-Sup
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.4
    • /
    • pp.313-319
    • /
    • 2000
  • As the interest of flexible manufacturing systems and computer integrated manufacturing systems increase, the distribution of centralized control systems using industrial control networks is getting more attention. In this paper, we investigate the rate-based traffic control of industrial control networks to improve the performance regarding the throughput, fairness, and error rates. Especially, we consider the protocol of Lon-$Works^{(TM)}$ which consists of all OSI 7-layers and supports various communication media at a low cost. Basically, the proposed rate-based traffic control system is closed loop by utilizing the feedback channel errors, which shows improved performance when compared with other industrial control networks commonly operated in open loop. To this end, an additional network node called monitoring node is introduced to check the channel status without increasing the channel load. The Proposed control loop is in effect whenever the feedback channel error becomes greater than an admittable value. We demonstrate the improved performance of the controlled network system in view of throughput and fairness measures by implementing the lab-scale network system based on LonWorks and through the experimentation upon it.

  • PDF

A New $H_2$ Bound for $H_{\infty}$ Entropy

  • Zhang, Hui;Sun, Youxian
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.4
    • /
    • pp.620-625
    • /
    • 2008
  • The $H_{\infty}$ entropy in $H_{\infty}$ control theory is discussed based on investigating information transmission in continuous-time linear stochastic systems. It is proved that the stabilizing feedback does not change the time-average information transmission between system input and output, and the $H_{\infty}$ entropies of open- and closed-loop stable transfer functions are bounded by mutual information rate between input and output in the open-loop system. Furthermore, a new $H_2$ upper bound for $H_{\infty}$ entropy is introduced with a numerical example. Thus the $H_{\infty}$ entropy of a stable transfer function is sandwiched between $H_2$ norms of the original system and a static feedback system.

A Diagnostic Method of Control-in/out in the Glass Furnace

  • Cho, Jin-Hyung;Lee, Sae-Jae;Jang, Do-Soo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.29 no.1
    • /
    • pp.151-154
    • /
    • 2006
  • The high degree of viscosity and the non-Newtonian fluid dynamics characterizes the process inside a glass furnace. Because the temperature is fluctuating in very short time-intervals, it is hard to determine that the status of its fluctuation is stable or unstable. Usually Shewhart-chart is used to determine the control status. However because of the characteristics of the temperature fluctuations in the glass furnace it does not directly serve the purpose here. Therefore we suggest using ARIMA to diagnose control status and confirm that the method using ARIMA can be a better tool than Shewhart-chart.

Development of Continuous Process Control System Using Torque Controlled Vector Inverter (벡터 인버터의 토크 제어를 이용한 연속공정 제어 시스템 개발)

  • Byun, S.H.;Cheong, J.Y.;Hong, C.O.;Kim, K.S.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.314-315
    • /
    • 2010
  • This paper presents the design and development of Web control algorithm of continuous process control system using torque controlled vector inverter. Web algorithm used tension control with the tension sensor, and it is to calculate diameter of motor speed with maintain Web tension. The performance of Web control in this paper is verified by experiment.

  • PDF

TEMPERATURE CONTROL SYSTEM in PLC (PLC에서의 온도 제어 시스템 구현)

  • Song, S.W.;Oh, Y.S.;Ryou, J.S.;An, C.B.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1063-1065
    • /
    • 1996
  • As PLC has become central to today's FA environment, the importance of developing and providing special-module of PLC such as Analog-module, PID-module, Temperature Control-module has increased. In this paper introduces the Temperature Control-module which is developed by LGIS R&D lab. and presents the availability of PLC-control system with Temperature Control-module.

  • PDF

A study on acceleration / deceleration control and circular interpolation using PLC position control unit (PLC 위치결정 UNIT에 의한 가감속 제어 및 원호보간에 관한 연구)

  • Kim, S.W.;Kim, J.S.;Yoo, J.S.;Ann, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.391-394
    • /
    • 1993
  • The acceleration/deceleration control method and interpolated operating are essential to the servo motor control system. In a few years ago, a floating point DSP chip was used for the purpose of processing a lot of calculated amount. But in this paper, we proposed new acceleration/deceleration control method and circular interpolation algorithm without another floating point DSP chip. The validity of proposed algorithms are verified through computer simulation and experimental result.

  • PDF

Development of Static Inverter for the Tilting Train express TTX (틸팅 차량용 보조전원장치의 개발)

  • Lee, Chang-Hee;Kim, Hyung-Cheol;Song, Young-Shin;Lee, Eun-Kyu;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1537-1539
    • /
    • 2005
  • This paper proposes 210[kVA] rated SIV(Static Inverter) system for the TTX(Tilting Train eXpress). The SIV provides power of a fluorescent light in the car, Air-conditioner, and other equipments. To control output voltage it is used voltage control loop for constant voltage control and simultaneously used current control loop for instantaneous control at load changing. The performance of SIV system will be verified by simulation and experimental results.

  • PDF

Using Ambient Control to Prevent External Disturbances in Large-scale Furnace (대형 용해로의 외부 환경변수를 통제하기 위한 주변 환경관리의 활용)

  • Cho, Jin-Hyung;Chang, Sung-Ho;Lee, Sae-Jae;Jang, Do-Soo;Suh, Jung-Yul;Oh, Hyun-Seung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.29 no.2
    • /
    • pp.92-96
    • /
    • 2006
  • Large glass furnaces to produce glass for CRT are housed in huge chambers. It is costly to maintain such a chamber in constant temperature, humidity, and(air) pressure. In this study, first, we show that the process of such a huge furnace, which requires the steady maintenance of high temperature, is badly affected by the ambient temperature of surrounding air. Second, an alternative process which not only maintains the relatively constant temperature dispersion around the furnace, but is also economical will be proposed. We calculate the necessary volume of air inflow in the appendix.

Development of Current-based Compact Digital Protective Relay for Induction Motor Protection (중용량 전동기보호를 위한 전류형 디지털 보호계전기 개발)

  • Jung, Jong-Jin;Kim, Joong-Pyo;Shin, Jong-Han;Park, Jang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.140-142
    • /
    • 2005
  • This paper describes the current- based compact digital motor protective relay for low and high voltage induction motors, which are widely used in industrial and commercial power systems. The existing protective relays for motor protection had only overload, short circuit, reverse phase, open circuit and grounding protective elements, and measurement, start/stop control function. But in present day, for automation system, various functions are required, especially motor management and sequence control function and more. To meet these requirements, we developed an economic current-based compact digital motor protective relay which had various function to control, manage and monitor the induction motor.

  • PDF

Evaluation of Demerit-CUSUM Control Chart Performance Using Fast Initial Response (FIR을 이용한 Demerit-CUSUM 관리도의 수행도 평가)

  • Kang, Hae-Woon;Kang, Chang-Wook;Baik, Jae-Won;Nam, Sung-Ho
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.32 no.1
    • /
    • pp.94-101
    • /
    • 2009
  • Complex Products may present more than one type of defects and these defects are not always of equal severity. These defects are classified according to their seriousness and effect on product quality and performance. Demerit systems are very effective systems to monitoring the different types of defects. So, classical demerit control chart used to monitor counts of several different types of defects simultaneously in complex products. S.M. Na et al.(2003) proposed the Demerit-CUSUM for the improvement of the demerit control chart performance and Nembhard, D. A. et al.(2001) and G.Y Cho et al.(2004) developed a Demerit control chart using the EWMA technique and evaluated the performance of the control chart. In this paper, we present an effective method for process control using the Demerit-CUSUM with fast initial response. Moreover, we evaluate exact performance of the Demerit-CUSUM control chart with fast initial response, Demerit-CUSUM and Demerit-EWMA according to changing sample size or parameters.