• 제목/요약/키워드: Induced current

검색결과 2,692건 처리시간 0.034초

Numerical investigation on vortex-induced vibration response characteristics for flexible risers under sheared-oscillatory flows

  • Xue, Hongxiang;Yuan, Yuchao;Tang, Wenyong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제11권2호
    • /
    • pp.923-938
    • /
    • 2019
  • Surge motion of top-end platform induced by periodic wave makes marine flexible riser encounter equivalent sheared-oscillatory flow, under which the Vortex-induced Vibration (VIV) response will be more complicated than pure sheared flow or oscillatory flow cases. Based on a time domain force-decomposition model, the VIV response characteristics under sheared-oscillatory flows are investigated numerically in this paper. Firstly, the adopted numerical model is validated well against laboratory experiments under sheared flow and oscillatory flow. Then, 20 sheared-oscillatory flow cases with different oscillation periods and top maximum current velocities are designed and simulated. Under long and short oscillation period cases, the structural response presents several similar features owing to the instantaneous sheared flow profile at each moment, but it also has some different patterns because of the differently varying flow field. Finally, the effects and essential mechanism of oscillation period and top maximum current velocity on VIV response are discussed systematically.

짧은 전류 펄스를 이용한 전류 유도 자화 반전에서 에너지 장벽 분포의 효과 (Effect of Energy Barrier Distribution on Current-Induced Magnetization Switching with Short Current Pulses)

  • 김우영;이경진
    • 한국자기학회지
    • /
    • 제21권2호
    • /
    • pp.48-51
    • /
    • 2011
  • 본 논문에서는 짧은 전류 펄스를 이용한 미소자기 소자에서의 전류 유도 자화 반전에 대한 매크로 스핀 시뮬레이션 연구를 수행하였다. 자화 반전 전류 분포에 있어서 에너지 장벽이 미치는 효과에 특별히 주목하였다. 자화 반전 전류의 크기 및 분포는 전류 펄스 폭의 감소에 따라 증가했다. 여기서 긴 전류 펄스 폭 영역에서는 에너지 장벽과 자화 반전 전류 분포 사이의 관계가 아레니우스-닐 법칙에 의해 서술된다. 하지만 짧은 전류 펄스 폭의 영역에서는 이 관계가 풀리지 않은 채로 남아있다. 이는 짧은 전류 펄스로 인한 자화 반전이 열적 활성화에 의해서가 아닌 세차 운동에 의해 좌우되기 때문이며, 이를 해결하는 데에 있어서 어려움이 발생한다. 그러므로 포커-플랑크 방정식을 풀어서 짧은 전류 펄스 영역에서의 자화 반전에 대한 정확한 공식을 얻어내는 것이 필요하며 이를 통해 짧은 전류 펄스 영역에서의 자화 반전 양상을 이해 할 수 있을 것으로 본다.

나노구조 이중게이트 FinFET의 크기변화에 따른 문턱전압이동 및 DIBL 분석 (Analysis of Dimension-Dependent Threshold Voltage Roll-off and DIBL for Nano Structure Double Gate FinFET)

  • 정학기
    • 한국정보통신학회논문지
    • /
    • 제11권4호
    • /
    • pp.760-765
    • /
    • 2007
  • 본 연구에서는 나노구조 이중게이트 FinFET에 대하여 문턱전압이동 특성 및 드레인유기장벽저하(Drain Induced Barrier Lowering; DIBL)특성을 분석하였다. 분석을 위하여 분석학적 전류모델을 개발하였으며 열방사전류 및 터널링전류를 포함하였다. 열방사전류는 포아슨방정식에 의하여 구한 포텐셜분포 및 맥스월-볼쯔만통계를 이용한 캐리어분포를 이용하여 구하였으며 터널링 전류는 WKB(Wentzel-Kramers-Brillouin)근사를 이용하였다. 이 두 모델은 상호 독립적이므로 각각 전류를 구해 더함으로써 문턱 전압을 구하였다. 본 연구에서 제시한 모델을 이용하여 구한 문턱 전압 이동값이 이차원 시뮬레이션값과 비교되었으며 잘 일치함을 알 수 있었다. 분석 결과 10nm 이하에서 특히 터널링의 영향이 증가하여 문턱전압이동 및 DIBL이 매우 현저하게 나타남을 알 수 있었다. 이러한 단채널현상을 감소시키기 위하여 채널두께 및 게이트산화막의 두께를 가능한한 얇게 제작하여야함을 알았으며 이를 위한 산화공정개발이 중요하다고 사료된다.

제주외항 건설에 따른 주변 해역의 해빈류 변화 예측 (A Simulation of Wave Induced Current Around the Jeju New Harbor)

  • 곽문수;편종근
    • 한국방재학회 논문집
    • /
    • 제4권3호
    • /
    • pp.1-8
    • /
    • 2004
  • 본 연구에서는 하디크로스법을 적용한 해빈류 해석 수치모델을 사용하여 제주외항의 건설진, 후에 대한 주변 해연의 흐름 변화를 예측하였다. 수치계산은 외항 건설전의 현재상태와 구조물 완공후의 상태에 대하여 실시하였고, 파향은 계절적인 변화를 고려하여 겨울철 NNW 방향과 여름철 NE 방향을 각각 검토하였다. 계산결과는 건설전, 후 모두 겨울철 NNW 방향의 고파랑 내습시 해빈류가 크게 발생하였다. 또한, 건설전에는 외항 건설 예정해역에서 서쪽에서 동쪽으로 향하는 연안류가 발생하여 화북동 전면해역에서 이안류를 형성하였지만, 건설후에는 화북동 전면해역에서 이안류가 순환류의 형태로 변화하였으며, 외항 입구에서 작은 순환류가 나타남을 볼 수 있었다. 한편, 외항에서 북동쪽으로 3.0km 떨어진 삼양해수욕장 주변의 흐름분포는 외항과 반대방향인 서쪽에서 동쪽으로 연안류가 발생하고 있음을 알 수 있었으며, 해수욕장의 표사이동에 의해서 외항에 미치는 영향은 매우 작을 것으로 판단된다.

A Simulator for Calculating Normal Induced Voltage on Communication Line

  • Heo, Jeong-Yong;Seo, Hun-Chul;Lee, Soon-Jeong;Kim, Yoon Sang;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1394-1400
    • /
    • 2014
  • The current flowing through the overhead transmission lines causes induced voltage on the communication lines, which can be prevented by calculating the induced voltage at the planning stage for overhead transmission line installment through an agreement between the communication and electric power companies. The procedures to calculate the induced voltages, however, are complicated due to the variety of parameters and tower types of the overhead transmission lines. The difficulty necessitates the development of a simulator to measure the induced voltage on the communication lines. This paper presents two simulators developed for this purpose; one using the Data Base (DB) index method and the other using the Graphic User Interface (GUI) method. The simulators described in this paper have been implemented by the EMTP (Electromagnetic Transient Program).

Analysis of Induced Voltage on Telecommunication Line in Parallel Distribution System

  • Kim, Hyun-Soo;Rhee, Sang-Bong;Lee, Soon-Jeong;Kim, Chul-Hwan;Kim, Yoon Sang
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.726-732
    • /
    • 2014
  • A current flowing through a distribution conductor produces induced voltage, which is harmful to a telecommunication line. Previous research on induced voltage has been focused on single-circuit lines in the distribution system. However, the double-circuit lines, referred to as parallel distribution lines, are widely used in distribution systems because they have significant economic and environmental advantages over single-circuit lines. Therefore, a study on the induced voltage in double-circuit lines is needed. This paper presents a method of calculating the induced voltage in a parallel distribution system using four-terminal parameters and vector analysis. The calculation method is verified by the Electromagnetic Transient Program (EMTP) simulation.

저온 제작 다결정 실리콘 박막 트랜지스터의 off-current메카니즘에 관한 연구 (A study on the off-current mechanism of poly-Si thin film transistors fabricated at low temperature)

  • 진교원;김진;이진민;김동진;조봉희;김영호
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권10호
    • /
    • pp.1001-1007
    • /
    • 1996
  • The conduction mechanisms of the off-current in low temperature (.leq. >$600^{\circ}C$) processed polycrystalline silicon thin film transistors (LTP poly-Si TFT'S) have been systematically studied. Especially, the temperature and bias dependence of the off-current between hydrogenated and nonhydrogenated poly-Si TFT's were investigated and compared. The off-current of nonhydrogenated poly-Si TF's is because of a resistive current at low gate and drain voltage, thermally activated current at high gate and low drain voltage, and Poole-Frenkel emission current in the depletion region near the drain at high gate and drain voltage. After hydrogenation it has shown that the off -current mechanism is caused mainly by thermal activation and that the field-induced current component is suppressed.

  • PDF

Modified-Current-Differential Relay for Transformer Protection

  • Kang Yong-Cheol;Jin En-Shu;Won Sung-Ho
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권1호
    • /
    • pp.1-8
    • /
    • 2005
  • During magnetic inrush or over-excitation, saturation of the core in a transformer draws a significant exciting current, which can cause malfunction of a current-differential relay. This paper proposes a modified-current-differential relay for transformer protection. The relay calculates the core-loss current from the induced voltage and the core-loss resistance as well as the magnetizing current from the core flux and the magnetization curve. Finally, the relay obtains the modified differential current by subtracting the core-loss and the magnetizing currents from the conventional differential current. A comparative study of the conventional differential relay with harmonic blocking is presented. The proposed relay not only discriminates magnetic inrush and over-excitation from an internal fault, but also improves the relay speed.