• Title/Summary/Keyword: Induced current

Search Result 2,684, Processing Time 0.035 seconds

Experimental study on vortex-induced motions of a semi-submersible with square columns and pontoons at different draft conditions and current incidences

  • Liu, Mingyue;Xiao, Longfei;Lu, Haining;Xiao, Xiaolong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.9 no.3
    • /
    • pp.326-338
    • /
    • 2017
  • The Vortex-induced Motions (VIM) phenomenon of semi-submersibles is relevant for the fatigue life of moorings and risers. Model tests regarding the VIM behavior of a semi-submersible with four square columns were conducted in order to investigate the effects of the current incidence and the aspect ratio of the immerged column. The experimental results show that the largest transverse amplitudes are around 70% of the column width at $30^{\circ}$ and $45^{\circ}$ incidences in a range of reduced velocities from 5 to 8 when the aspect ratio of the immerged column is 1.90. The largest yaw motion occurs at $0^{\circ}$ incidence with the peak value around $4.5^{\circ}$. Similar characteristics of the VIM response are observed for the semi-submersible with aspect ratios of 1.90 and 1.73. When the aspect ratio decreases 50% to 0.87, 30% decrease in the peak transverse amplitudes can be seen.

Fast Convergent Solution of TM Scattering by Conducting Strip Grating on Two Dielectric Layers (2개 유전체층 위의 완전도체띠 격자구조에 의한 TM 산란의 급속한 수렴 해)

  • Yoon, Ueil-Joong
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.1
    • /
    • pp.78-83
    • /
    • 2014
  • In this paper, the solutions of TM (transverse magnetic) scattering problems by perfectly conducting strip grating on two dielectric layers are analyzed by applying the FGMM (Fourier Galerkin moment method) as a numerical method. For the TM scattering problem, the induced surface current density is expected to the very high value at both edges of the strip, then the induced surface current density on the strip is expanded in a series of the multiplication of the functions of appropriate edge boundary condition and the Chebyshev polynomials of the first kind. The numerical results are obtained for the magnitude of induced current density, the normalized reflected power and transmitted power. The numerical results using proposed functions were improved the convergence faster than existing exponential functions, and the numerical results shown the good agreement compared to those of the existing papers.

Eddy Current Testing of Type-439 S/S Tube of MSR in Turbine System (터빈 습분분리재열기 Type-439 스테인리스강 튜브 와전류검사)

  • Lee, Heejong;Cho, Chanhee;Jung, Jeehong;Moon, Gyoonyoung
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.4 no.2
    • /
    • pp.50-56
    • /
    • 2008
  • The tubes in heat exchanger are typically made of copper alloy, stainless steel, carbon steel, titanium alloy material. Type-439 ferritic stainless steel is ferromagnetic material, and furnish higher heat transfer rates than austenitic stainless steels and higher resistance to corrosion-induced flaws. Ferritic stainless steel can be found in low-pressure(LP) feedwater heaters and moisture separator reheaters(MSRs) in turbine system. LP feedwater heaters generally utilize thin wall Type-439 stainless steel tubing, whereas MSRs typically employ a heavier wall tubing with integral fins. Service-induced damage can occur on the O.D(outside diameter) surface of Type-439 ferritic stainless steel tubing which is employed for MSRs tubing, and the most typical damage mechanism is vibration-induced tube-to-TSP(tube support plate) wear and fatigue cracking. The wear has been reported that occurs mainly on the OD surface. Accordingly, in this study, we have evaluated the flaw sizing capability of magnetic saturation eddy current technique using magnetic saturation probe and flawed specimen.

  • PDF

Analysis of Construction Procedure of Breakwater in consideration of Harbor Siltation (항내매몰을 고려한 방파제의 시공순서 검토)

  • Yoon, Seong-Jin;Kim, Kyu-Han
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.1
    • /
    • pp.73-80
    • /
    • 2007
  • The predominant factor considered in the design of harbors in the East Coast of Korea is wave propagating onshore. Also, the strong wave induced current on the east coast have the biggest influence on sediment transport around the harbor structure. Therefore, a consideration of wave induced current due to waves should take place on design when constructing a harbor on east coast. In this study, we studied on the influences of construction procedure on harbor siltation using annual coastal line data and bathymetry data near breakwater. And, this study focused on investigation of the construction procedure for the best way to decrease harbor siltation.

Improvement of Short Circuit Performance in 460[V]/400{A]/85(kA] Molded Case Circuit Breakers (460[V]/400[A]/85[kA] 배선용 차단기의 아크런너 변형을 통한 차단성능 향상)

  • Lee, Seung-Su;Her, June;Yoon, Jae-Hun;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.394-394
    • /
    • 2009
  • Owing to the increasing number of intelligent homes(or called Smart home), the corresponding cost is much higher. Low voltage circuit breakers are widely used in the intelligent homes to interrupt fault current rapidly and to assure the reliability of the power supply. The distribution of magnetic field induced by arc current in the contact system of molded case circuit breaker(hereafter MCCB) depends on the shape, arrangement, and kinds of material of arc runner. This paper is focused on understanding the interrupting capability, more specifically of the arc runner, based on the shape of the contact system in the current MCCB. The magnetic driving force was calculated by using the flux densities induced by the arc current, which are obtained by three-dimensional finite element method. There is a need to assure that the optimum design required to analyze the electromagnetic forces of the contact system generated by current and the flux density be present. This is paper present our computational analysis on contact system in MCCB.

  • PDF

Improvement of Short Circuit Performance in 460[V]/400[A]/85[kA] Molded Case Circuit Breakers (460[V]/400[A]/85[kA] 배선용 차단기의 그리드 및 아크런너 변형을 통한 차단성능 향상)

  • Lee, Seung-Su;Jung, Eui-Hwan;Yoon, Jae-Hun;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1451_1452
    • /
    • 2009
  • Owing to the increasing number of intelligent homes(or called Smart home), the corresponding cost is much higher. Low voltage circuit breakers are widely used in the intelligent homes to interrupt fault current rapidly and to assure the reliability of the power supply. The distribution of magnetic field induced by arc current in the contact system of molded case circuit breaker depends on the shape, arrangement, and kinds of material of grids. This paper is focused on understanding the interrupting capability, more specifically of the grid and the arc runner, based on the shape of the contact system in the current MCCB. The magnetic driving force was calculated by using the flux densities induced by the arc current, which are obtained by three-dimensional finite element method. There is a need to assure that the optimum design required to analyze the electromagnetic forces of the contact system generated by current and the flux density be present. This is paper present our computational analysis on contact system in MCCB.

  • PDF

Calcium permeability of transient receptor potential canonical (TRPC) 4 channels measured by TRPC4-GCaMP6s

  • Ko, Juyeon;Myeong, Jongyun;Yang, Dongki;So, Insuk
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.21 no.1
    • /
    • pp.133-140
    • /
    • 2017
  • Conflicting evidence has been obtained regarding whether transient receptor potential cation channels (TRPC) are store-operated channels (SOCs) or receptor-operated channels (ROCs). Moreover, the Ca/Na permeability ratio differs depending on whether the current-voltage (I-V) curve has a doubly rectifying shape or inward rectifying shape. To investigate the calcium permeability of TRPC4 channels, we attached GCaMP6s to TRPC4 and simultaneously measured the current and calcium signals. A TRPC4 specific activator, (-)-englerin A, induced both current and calcium fluorescence with the similar time course. Muscarinic receptor stimulator, carbachol, also induced both current and calcium fluorescence with the similar time course. By forming heteromers with TRPC4, TRPC1 significantly reduced the inward current with outward rectifying I-V curve, which also caused the decrease of calcium fluorescence intensity. These results suggest that GCaMP6s attached to TRPC4 can detect slight calcium changes near TRPC4 channels. Consequently, TRPC4-GCaMP6s can be a useful tool for testing the calcium permeability of TRPC4 channels.

The Impact of Gate Leakage Current on PLL in 65 nm Technology: Analysis and Optimization

  • Li, Jing;Ning, Ning;Du, Ling;Yu, Qi;Liu, Yang
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.1
    • /
    • pp.99-106
    • /
    • 2012
  • For CMOS technology of 65 nm and beyond, the gate leakage current can not be negligible anymore. In this paper, the impact of the gate leakage current in ring voltage-controlled oscillator (VCO) on phase-locked loop (PLL) is analyzed and modeled. A voltage -to-voltage (V-to-V) circuit is proposed to reduce the voltage ripple on $V_{ctrl}$ induced by the gate leakage current. The side effects induced by the V-to-V circuit are described and optimized either. The PLL design is based on a standard 65 nm CMOS technology with a 1.8 V power supply. Simulation results show that 97 % ripple voltage is smoothed at 216 MHz output frequency. The RMS and peak-to-peak jitter are 3 ps and 14.8 ps, respectively.

Characteristics of Drawing and Concurrent Spot Welding of Overlapped Aluminum Plates with Copper Electrodes Inserted in Heated Dies (가열된 금형에 삽입된 구리전극에 의한 중첩된 알루미늄 합금판재의 드로잉성형 동시 점용접 특성)

  • Kim, T.H.;Jin, I.T.
    • Transactions of Materials Processing
    • /
    • v.26 no.3
    • /
    • pp.174-180
    • /
    • 2017
  • In this study, a new spot welding with electric resistance heated dies is suggested for the spot welding of non-ferrous metal plates for drawing and concurrent spot welding. This welding method involves two heating processes such as heating by conduction of electric resistance heated dies and heating by resistance between contacted surfaces of two plates by welding current induced to copper dies for the fusion of contacted metal. This welding process has welding variables such as current induced in heated and copper dies, the inner diameters of heated dies, and edge shape of the copper dies. Experimental conditions for each current should be established to get successful welding strength. The welding strength could reach to the desired value in industrial fields under the following conditions of contact diameters of heated dies in this case of overlapped aluminum5052 plates with 0.3-mm thickness: inner and outer diameters of 5.0 and 16mm, respectively; diameter of copper dies, 5.0mm; heating current, 6.8kA in heated steel dies; welding current, 8.6 kA in copper dies.

Current-induced Phase Demodulation Using a PWM Sampling for a Fiber-optic CT

  • Park, Hyoung-Jun;Lee, June-Ho;Kim, Hyun-Jin;Song, Min-Ho
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.240-244
    • /
    • 2010
  • In this work, we used PWM sampling for demodulation of a fiber-optic interferometric current transformer. The interference signal from a fiber-optic CT is sampled with PWM triggers that produce a 90-degree phase difference between two consecutively sampled signals. The current-induced phase is extracted by applying an arctangent demodulation and a phase unwrapping algorithm to the sampled signals. From experiments using the proposed demodulation, we obtained phase measurement accuracy and a linearity error, in AC current measurements, of ~2.35 mrad and 0.18%, respectively. The accuracy of the proposed method was compared with that of a lock-in amplifier demodulation, which showed only 0.36% difference. To compare the birefringence effects of different fiber-optic sensor coils, a flint glass fiber and a standard single-mode fiber were used under the same conditions. The flint glass fiber coil with a Faraday rotator mirror showed the best performance. Because of the simple hardware structure and signal processing, the proposed demodulation would be suitable for low-cost over-current monitoring in high voltage power systems.