• Title/Summary/Keyword: Induce power

Search Result 334, Processing Time 0.026 seconds

Operation Effectiveness Evaluation According to Conductor Transposition Adoption in Underground Power Cable Systems (지중송전케이블의 도체연가방식 채용시 효용성 평가)

  • Kim, June;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.5
    • /
    • pp.636-643
    • /
    • 2014
  • Length of most underground power cable in nation is not so long. Therefore it is operated without conductor transposition due to low unbalanced ratio. However, if cable length is long, line constant of each cable will be different. Different line constant can induce unbalanced voltage and current of sheath. Also it can induce several induced interference. This paper describes the operation effectiveness through steady and transient analysis on transposition and untransposition of cable conductor. Especially sheath current and induced voltage are analyzed and compared in case of transposition and untransposition. EMTP is used for modeling and analysis.

Response of Amber Fish, Seriola aureovitta to Electric Stimuli (부시리의 전기자극에 대한 반응)

  • Chang, Ho-Young;Lee , Byoung-Gee
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.21 no.1
    • /
    • pp.19-27
    • /
    • 1985
  • It is important to minimize the electric power consumption to stimulate the marine fish, for the much electric power consumption is required to induce the response. The experiment was made to find out the threshold value for the electrotaxis or electronarcosis on amber fish, Seriola aureovitta(TEMMINCK et SCHLEGEL). The impulse rate and width which minimize the electric power consumption were examined. The experiment was carried out in the acryl tank(49W$\times$175L$\times$50Hcm) which is equipped with the two electrodes. The results obtained are as follows: 1) The electric power consumption which is required to induce the electorates and electronarcosis is tended to decrease as the lower impulse rate. 2) The mean electric power consumption for the electronarcosis is about 4.5~10 times of the electrotaxis. 3) The impulse width which minimize the electric power consumption is 0.5msec.

  • PDF

An Introduction to Speed Control System of Small Steam Turbine for Feed Water Supply in Power Plant (발전소 급수펌프 구동용 소형 터빈 제어시스템 소개)

  • Choi, In-Kyu;Kim, Jong-An
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1603-1604
    • /
    • 2007
  • The load of power plants changes every from time to time according to which steam flow of boiler changes. the feed water control is very important for the power plant to be operated in its stability conditions. In case of circulation type boiler, the instability of feed water control leads to instability of drum level control. The higher level of drum water can induce bad quality steam to go into turbine which means the possibility of damage. The lower level of drum water can induce the tubes of boiler water wall to be overheated. In case of once through type boiler, the instability of feed water control leads to bad cooling of superheaters. The less the feed water flow is, the more heated the superheater is. It is necessary for the turbine driving feed water pump to be controlled for the optimal feed water flow in the large capacity power plant. The speed of turbine is controled for the feed water flow. By the way, the optimal control of steam valve is necessary for the speed control of turbine. Therefore, the various kinds of the steam valve structures are introduced in this paper

  • PDF

Effectiveness Evaluation and Operation Scheme on Cable Transposition in Underground Transmission Systems with Ungrounded Joint Box (접속함 비접지 지중송전계통에서 도체연가방식 채용의 효용성 평가 및 운용방안 수립)

  • Kim, June;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.240-246
    • /
    • 2015
  • Length of most underground power cable in home is not so long. Therefore it is operated without transposition due to low unbalanced ratio. However, if cable length is long, line constant of each cable will be different. Different line constant can induce unbalanced voltage and current of sheath. Also it can induce several induced interference. This paper describes the effectiveness of transposition through sheath component analysis on transposition and untransposition of cable conductor. Especially sheath current and induced voltage are analyzed and compared in case of transposition and untransposition. EMTP is used for modeling and analysis.

The Effects of Power-of-Speech and Sex of Source on Persuasion, in Radio CM (라디오 광고에서 언어 힘의 설득 효과와 정보원 성(性)의 영향)

  • Chun, Hyun-Suk;Lyi, De-Ryoung
    • Journal of Global Scholars of Marketing Science
    • /
    • v.16 no.1
    • /
    • pp.93-116
    • /
    • 2006
  • The main purpose of this study is to examine whether power-of-speech have an impact on persuasion in radio CM and to determine what is stronger variable either power-of-speech or sex of source. Previous research showed confused result about this issue. Some research supposed the effect of power-of-speech depend on sex of source/Carli, 1990) but the others supposed it is not(Holtgraves & Lasky, 1999; Erickson, Lind, Johnson, & O'Barr, 1978). So present research is designed to show empirical evidence about this issue examining the interaction between effect of power-of-speech and sex of source. Result revealed that power-of-speech affects strongly on persuasion and that effect have no interaction with sex of source. This result means that the effect of power-of-speech is stronger than the effect of sex of source. But in attitude toward product exceptionally, female source using powerful speech induce more favorable attitude toward product than female source using powerless speech whereas male source using powerful and powerless speech induce same attitude toward product.

  • PDF

A Design of Control Network for DCS in Nuclear Power Plant (원전 DCS용 제어통신망 설계)

  • 이재민;박태림;문홍주;권욱현
    • Proceedings of the IEEK Conference
    • /
    • 2000.06a
    • /
    • pp.85-88
    • /
    • 2000
  • Distributed Control System(DCS) is one of the best solutions to implement control systems because it provides continuous observation of control process and execution of commands to induce proper operations. In this paper, a design of control network for DCS in nuclear power plant is proposed. The proposed control network on DCS has a simple architecture and deterministic property. Thus, the proposed control network offers hard real-time periodic service. It also has redundant media for the fault-tolerance. As a result, high safety and reliability required in nuclear power plant are guaranteed.

  • PDF

A Study on the Hazard Factor and Safety Management at Transmission Line During Live Line Works (송전선로 직접활선공법의 위험요인과 안전대책에 관한 연구)

  • Choi, Seung-Dong;Kang, Kyong-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.3
    • /
    • pp.51-66
    • /
    • 2006
  • This study was attempted to analyze risk factors and suggest accident prevention in live line works for power transmission lines to be developed and applied in Korea. Safety problem cannot but occur at development of live line works and application to the field. With respect to this, problems likely to occur in the field among works adopting methods of works including live line works for power transmission lines were investigated and analyzed through documentary survey and risk assessment method. The results are summarized as follows. A risk assessment method model was suggested. This method enables scientific and systematic development of safety control. That is, the owner may autonomously induce safety control and build risk assessment database by work process to use them as best training data for workers. Also, in the field, it may induce all workers to participate in safety program and secure safety by making workers seek for safety working method under smooth flow from looking at risk factors to accident prevention activities. It is deemed that this humble study will prevent both accident and injury likely to occur in live line works for power transmission lines.

Switching Transient Shaping by Application of a Magnetically Coupled PCB Damping Layer

  • Hartmann, Michael;Musing, Andreas;Kolar, Johann W.
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.308-319
    • /
    • 2009
  • An increasing number of power electronic applications require high power density. Therefore, the switching frequency and switching speed have to be raised considerably. However, the very fast switching transients induce a strong voltage and current ringing. In this work, a novel damping concept is introduced where the parasitic wiring inductances are advantageously magnetically coupled with a damping layer for attenuating these unwanted oscillations. The proposed damping layer can be implemented using standard materials and printed circuit board manufacturing processes. The system behavior is analyzed in detail and design guidelines for a damping layer with optimized RC termination network are given. The effectiveness of the introduced layer is determined by layout parasitics which are calculated by application of the Partial Element Equivalent Circuit (PEEC) simulation method. Finally, simulations and measurements on a laboratory prototype demonstrate the good performance of the proposed damping approach.

Routing Protocol for Energy Balancing in Energy Harvesting Wireless Sensor network (에너지 하베스팅 무선 센서네트워크에서 에너지균형을 위한 라우팅프로토콜)

  • Kang, Min-Seung;Park, Hyung-Kun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.5
    • /
    • pp.666-669
    • /
    • 2020
  • Energy harvesting sensor networks have the ability to collect energy from the environment to overcome the power limitations of traditional sensor networks. The sensor network, which has a limited transmission range, delivers data to the destination node through a multi-hop method. The routing protocol should consider the power situation of nodes, which is determined by the residual power and energy harvesting rate. At this time, if only considering the magnitude of the power, power imbalance can occur among nodes and it can induce instantaneous power shortages and reduction of network lifetime. In this paper, we designed a routing protocol that considers the balance of power as well as the residual power and energy harvesting rate.

Risk Analysis of Electrical Fire for Electric Power Installations by Event Tree Analysis (사건수목분석을 통한 수배전설비의 전기화재위험성 분석)

  • Park, Young Ho;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.16-21
    • /
    • 2016
  • The purpose of this paper is to conduct ETA on 15 components of power installations: the DS/LBS, LA, MOF, CT, PT, A/V meter, VCB, OCR, COS, PF, Transformer, Condenser(C), Grounding, Cable and Connector. To achieve that, power installations work flow and its components are categorized. Based on performance, human, environmental, management, and safety, this paper drew Initiation events (IE) and End states (ES). ETA is applied to the main functions of each component, and the end states that may occur in one initiation event are suggested. In addition, detailed classification was performed to induce various end states on the basis of the suggested initiation events. If the suggested IEs and ESs are applied on the basis of power installations event cases, it is expected to prevent the same kinds of accident and operate power installations safely.