• Title/Summary/Keyword: Indoor materials

Search Result 610, Processing Time 0.034 seconds

Combustion Properties of Woods for Indoor Use (I) (실내사용 목재의 연소 특성 분석(I))

  • Son, Dong Won;Kang, Seog-Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.6
    • /
    • pp.675-681
    • /
    • 2014
  • The purpose of this study is to analyze fundamental combustion characteristics of woods used for indoor applications. The combustion characteristics such as heat release rate, total heat release, gas yield, and mass loss were analyzed by the method of cone calorimeter or thermogravimetry. These analysis results show that material properties of wood are closely related to flammability. It was shown that the relationship between the mass loss and gas emission. The results of combustion properties of woods would be useful for fundamentals of guiding the safe use of wood indoor application.

The Concentration Variation of Volatile Organic Compounds before and after Renovation in Apartment Houses (아파트 개조 전후의 휘발성유기화합물 농도변화 실태)

  • Choi, Yoon-Jung;Shim, Hyun-Suk;Shin, Hae-Chul
    • Journal of the Korean housing association
    • /
    • v.18 no.4
    • /
    • pp.59-67
    • /
    • 2007
  • The purposes of this study were to make clear the present condition of the TVOC and HCHO concentration after renovation in apartment houses. The field measurements of TVOC and HCHO concentration according to the Korea Test Method Standard for Indoor Air Quality were carried out in 4 subject apartment houses. The results are as follows; the TVOC concentration after renovation in apartment houses ranged from mean 0.35ppm to mean 5.08ppm and increased of $0.35{\sim}5.08ppm$. The TVOC concentration of 3 subjects exceeded the Indoor Air Quality Management standard for the newly-built apartment houses (0.58ppm). The HCHO concentration after renovation ranged from mean 0.13ppm to mean 0.43ppm and increased of $0.06{\sim}0.26ppm$. The HCHO concentration of 2 subjects exceeded the Standard (0.17ppm). As results of analysis on the relation of concentrated ascension and renovation elements, the amount and the types of finishing materials and adhesives affected concentrated ascension. Also, production method for installed or purchased furniture had certain effect on the TVOC and HCHO concentration ascension.

A Study on Predication model for TVOC Emissions of Finishing material in Apartment House (공동주택 건축내장재의 TVOC 방출량에 관한 예측모델 연구)

  • Kim, Hyung-Soo;Lee, Kyung-Hoi
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.55-62
    • /
    • 2002
  • While cognition about an environment pollution becomes important recently, the intense pollution measures about an indoor air environment is required. In the case of building indoor environment, over 80% of modem people is living in building and these days an interest of building interior materials which becomes a reason for indoor environmental pollution in public house, office, is increasing. An experimental measurement method of this study is as follows. (1) American EPA TO-17, ASTMD5116-97, measurement method in VOCs experiment of Japanese closet industrial association (2) 2.4-DNPH cartridge method in HCHO experiment, based on American EPA TO-11 and measurement method of Japanese closet industrial association (3) standard compound is analyzed by using HPLC after solvent extraction process (4) paint and furniture are selected as measurement objects (5) we also made small chamber to grasp an emission characteristic of HCHO and VOCs and to get an environment-amicable forecast model through it, then we developed the model which can forecast emission rate by chamber experiment.

The Materials of Earth Friendly Architecture (친환경 건축물의 자재에 관한 연구)

  • Yoo, Ho-Chun;Lee, Young-A
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.4
    • /
    • pp.81-88
    • /
    • 2003
  • Earth friendly system is applied widely to industries for maintaining development. The declaration of earth friendly characteristic which is an indication of the total amount of energy in evaluation of earth friendly material is not easy to apply to building materials Therefore, Accurate standards about earth friendly materials are necessary. Earth friendly building materials should be considered in the fields of energy and resource consumption, changes in urban climate and resident health, etc. Among these fields, energy and resource consumption has released toxic pollutants into the air, caused indoor moisture problems and exhausted resources continuously. Especially, moisture problem is an indicator of main factors of earth friendly characteristic. Timber, Soil. Cement Mortar and Charcoal are used to examine the sustainable properties of materials of moisture control. The result shows that wood, charcoal and soil is vivid in changes of moisture absorption and discharge in comparison with that of cement mortar.

A Study on Examples of Eco-Friendly School Design - Focusing on School Facilities in USA, Japan and Korea - (학교건축의 친환경적 계획수법에 대한 사례연구 - 미국, 일본, 한국의 학교건축을 중심으로 -)

  • Lee, Ji-Young;Lee, Kyung-Sun
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.2
    • /
    • pp.3-14
    • /
    • 2011
  • This study aims to identify differences and lessons in eco-school planning techniques and sustainable design methods by analyzing comparatively green building certification system and the cases of sustainable schools in US, Korea and Japan. As a result of the comparative analysis, green building certification system for school facilities, both domestic and international, is categorized into external environment, energy, materials and resources, and indoor environment. From the case study, it is common that roof garden and biotopes are installed for external environment, while energy saving, passive energy utilization methods for natural lighting and ventilation such as arrangement planning, courtyard, top-light, shading devices, solar panel and insulation by roof garden are most frequently used. Also, storm water uses, water saving equipment and sustainable materials are often introduced for resource savings. Concerns for indoor environment is frequently addressed by introducing natural light and ventilation in the buildings, which makes ultimately a comfortable space.

  • PDF

A Comparative Functionality Evaluation of Paulownia Wood Storage Boxes and Acid-free Archival Boxes to Store the Annals of Joseon Dynasty - Indoor and Outdoor Temperature and Relative Humidity Controls, and Heat Release Rate -

  • Park, Hae Jin;Kim, Seong Eun;Lee, Jin Kyung;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.38 no.1
    • /
    • pp.72-79
    • /
    • 2022
  • A paulownia wood has been widely used with various advantages as its low weight, permeability, convenient workability and aesthetic patterns for a long time. However, the related empirical researches and simultaneous evaluations of functionality are insufficient compared with acid-free archival boxes for now. In this study, the indoor and outdoor temperature and relative humidity control and heat release rate were evaluated under the controlled and uncontrolled circumstance in 2018. The paulownia wood storage box showed superior control effect of relative humidity than the acid-free archival box in constantly uncontrolled environment. Also, the possibility of the flame diffusion from the surface of the materials was higher for the paulownia materials, and the acid-free archival box showed more dangerous patterns in the early stages of the fire.

Adsorption Performance Evaluation of Powdery Polymer Cement Hardened Substances with Gelite (겔라이트를 혼입한 분말형 폴리머 시멘트 경화체의 흡착성능 평가)

  • Lee, Jeon-Ho;Lee, Chang-Woo;Hwang, Woo-Jun;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.164-165
    • /
    • 2022
  • In order to solve problems such as acceleration of resource use and environmental pollution, experiments were conducted with the aim of producing indoor finishing materials that can adsorb fine dust and carbon dioxide using gelite and polymer, which are porous materials. Based on the previous experiment, gelite was substituted at each level in a matrix having a polymer S738P substitution rate of 12.5%, and the results are as follows. As the substitution rate of gelite increased, the amount of fine dust and carbon dioxide adsorption increased, which is believed to be due to physical adsorption due to the high porosity of gelite. However, further experiments are needed as the overall adsorption amount is not high due to the filling inside the matrix due to the polymer.

  • PDF

Localization using Neural Networks and Push-Pull Estimation based on RSS from AP to Mobile Device (통신기지국과 모바일장치간의 수신신호강도를 기반으로 하는 신경망과 푸쉬-풀 평가를 이용한 위치추정)

  • Cho, Seong-Jin;Lee, Sung-Young
    • The KIPS Transactions:PartD
    • /
    • v.19D no.3
    • /
    • pp.237-246
    • /
    • 2012
  • Although the development of Global Positioning System (GPS) are more and more mature, its accuracy is just acceptable for outdoor positioning, not positioning for the indoor of building and the underpass. For the positioning application area for the indoor of building and the underpass, GPS even cannot achieve that accuracy because of the construction materials while the requirement for accurate positioning in the indoor of building and the underpass, because a space, a person is necessary, may be very small space with several square meters in the indoor of building and the underpass. The Received Signal Strength (RSS) based localization is becoming a good choice especially for the indoor of building and the underpass scenarios where the WiFi signals of IEEE 802.11, Wireless LAN, are available in almost every indoor of building and the underpass. The fundamental requirement of such localization system is to estimate location from Access Point (AP) to mobile device using RSS at a specific location. The Multi-path fading effects in this process make RSS to fluctuate unpredictably, causing uncertainty in localization. To deal with this problem, the combination for the method of Neural Networks and Push-Pull Estimation is applied so that the carried along the devices can learn and make the decision of position using mobile device where it is in the indoor of building and the underpass.

Characteristics of Exposure Distribution to Hazard Factors in Indoor Swimming Pool Activity Areas in Gwangju (수영장 활동공간 내 유해인자 노출특성 연구)

  • Lee, Youn-Goog;Kim, Nan-Hee;Choi, Young-Seop;Kim, Sun-Jung;Park, Ju-Hyun;Kang, Yu-Mi;Bae, Seok-Jin;Seo, Kye-Won;Kim, Jong-Min
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.2
    • /
    • pp.150-158
    • /
    • 2020
  • Objective: This study is designed to measure the concentration of DBPs (disinfection by-products) in pool water and in air and to estimate the carcinogenic potential through the evaluation of inhalation exposure. Methods: The subjects were six indoor swimming pools with many users in Gwangju. Samples of pool water and indoor air were taken every one month from August 2018 to August 2019 and analyzed for eight swimming pool standards. Three-liter air samples were collected and the VOCs were analyzed using GC/MS directly connected to thermal desorption. Results: pH was 6.8-7.5 and the concentration of free residual chlorine in pool water was 0.40-0.96 ?/ℓ. Physicochemical test items such as KMnO4 consumption and heavy metal items such as Aluminum met existing pool hygiene standards. No VOC materials were detected except for the DBPs. The concentration of THMs in the pool water was 11.05-41.77 ㎍/L and the THMs mainly consist of Chloroform (63-97%) and BDCM (3-31%). The concentration of indoor air THMs is 13.24-32.48 ㎍/㎥ and consists of Chloroform. The results of carcinogenic assessment of chloroform in the indoor swimming pool via inhalation exposure were 2.0 to 6.4 times higher than the 'acceptable risk level' suggested by the US EPA. Conclusions: The concentration of THMs in the pool water is 11.05-41.77 ㎍/L, most of which is chloroform. In addition, the concentration of indoor air THMs is 13.24-32.48 ㎍/㎥. The result of carcinogenic assessment of chloroform was 2.0 to 6.4 times higher than the 'acceptable risk level' suggested by the US EPA.

Determination of HONO Concentration and Investigation on Its Formation Mechanism Using a Continuous Measurement System in Indoor Environment of an Apartment (아파트 실내 환경에서 실시간 측정시스템을 활용한 HONO 농도 측정 및 생성기작 연구)

  • Park, Seung-Shik;Hong, Jin-H.;Lee, Jai-H.;Kim, Young-J.;Cho, Sung-Y.;Kim, Seung-J.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.1
    • /
    • pp.16-29
    • /
    • 2008
  • Nitrous acid (HONO) can be produced by heterogenous reactions of nitrogen dioxide on surface materials and direct emission from combustion sources. However, a little is known of indoor HONO levels or the relationship between residential HONO, NO, and $NO_2$ concentrations in occupied houses. Therefore, we measured simultaneously NO, $NO_2$, and HONO concentrations in living room of an apartment using continuous analyzers to study the production of HONO (June $22{\sim}30$, 2006). The 4-min average concentrations of indoor NO, $NO_2$, and HONO were 4.3 (range: $0.4{\sim}214.3$), 10.3 ($2.0{\sim}87.3$), and 1.8 ppb ($0.3{\sim}7.7$), respectively. Peak levels of HONO up to 7.7 ppb and 24-hr averages as high as 1.7 ppb were measured. In agreement with previous studies, indoor HONO concentrations increased during operation of an unvented gas range. Examination of the observed kinetics suggests that the secondary production of indoor HONO, possibly as a result of heterogeneous reactions involving $NO_2$ and $H_2O$ is associated with $[NO_2]^2[H_2O]\;(r^2=0.88)$ rather than with $[NO][NO_2][H_2O]\;(r^2=0.75)$. Three combustion experiments at nighttime were also carried out to investigate the effects of vented combustion on the HONO, NO, and $NO_2$ concentrations. It was found to release HONO for $10{\sim}15$ minutes after NO and $NO_2$ source was turned off, and peak values were finally attained. Compared to unvented combustion, peak $NO_2$ and HONO concentrations were 3.2 and 2.0 times lower at weak vented combustion (air flow: $340\;m^3/hr$) and 4.9 and 2.4 times lower at strong vented combustion (air flow: $540\;m^3/hr$), respectively, emphasizing importance of operating ventilation hood fan during combustion to improve indoor air quality.