• 제목/요약/키워드: Indoor environmental factors

검색결과 294건 처리시간 0.024초

포항과 구미의 대규모 산단지역 대기 중 휘발성 유기화합물 농도 분포 특성에 관한 연구 (Characterization of Atmospheric Concentrations of Volatile Organic Compounds in Industrial Areas of Pohang and Gumi Cities)

  • 백성옥;김수현;김미현
    • Environmental Analysis Health and Toxicology
    • /
    • 제20권2호
    • /
    • pp.167-178
    • /
    • 2005
  • This study was carried out to evaluate the temporal, spatial, and seasonal variations of VOC, and to characterize the VOC concentrations in two large industrial complexes located in Pohang and Gumi cities. Twenty -four hours continuous sampling of selected VOC was made with STS 25 sequential tube samplers and double-bed adsorbent tubes. Air samples were collected every three hour interval for 7 consecutive days in each site during summer and winter. VOC were determined by thermal desorption coupled with GC/MS. A total of 27 VOCs of environmental concern were determined, including aliphatic, aromatic and halides. Generally. concentrations of toxic VOC were higher in Gumi than Pohang, and VOC levels in industrial areas were typically several-fold higher than those in residential areas. The most abundant VOC appeared to be toluene for both cities. However, chlorinated VOC were higher in Gumi than Pohang, while aromatic VOC were more abundant in Pohang than in Gumi. Two cities showed relatively different variations of VOC concentrations within a day. It is likely that traffic related sources are major factors affecting the VOC in Pohang, and industrial solvents usages are important sources in Gumi. These results imply that the occurrence and levels of atmospheric VOC are strongly dependent on the type of industries in each city. Therefore, in order to develop any control strategies or to establish the priority rankings for VOC in large industrial complexes, the type of industries and the occurrence of VOC in the atmosphere should be taken into consideration.

노후 주거용 건축물 비구조체 해체 시 환경유해인자 분석 (A Study on the Analysis of Environmental Hazards when Dismantling Non-Structure of Old Residential Buildings)

  • 손병훈
    • 도시과학
    • /
    • 제10권1호
    • /
    • pp.29-37
    • /
    • 2021
  • The number of old buildings older than 30 years in Korea continues to increase from 29.9% in 2005 to 38.8% in 2020. Considering the growing urban regeneration projects, urban maintenance projects, the suppression of urban expansion, and the lack of idle land in the city, the dismantling of old buildings is expected to increase further in the future. As major accidents at building dismantling sites continue to occur, related agencies are also strengthening safety management of building dismantling works. While physical safety management such as collapse and fall is strengthened, there is a relative lack of interest in the health of workers at dismantling sites due to environmental hazards. Since relevant laws stipulate that construction waste should be separated and discharged, old buildings need to be considered for environmental hazards such as fine dust, floating bacteria, and floating molds when dismantling. In this study, we intend to find important safety management elements in the management of building dismantling sites, measure environmental factors harmful to dismantling workers, and present basic data for the management of dismantling sites in the future. "Safety management" was the highest priority, followed by "dust," "vibration," "noise," "bacteria," and "smell." The perception of the importance of "physical damage prevention" with workers working on dismantling and managers managing the site came out similar, but the perception of "work efficiency" and "health disorder prevention" through environmental hazard management showed different priorities. In the process of dismantling, floating bacteria and floating mold were collected, cultured, and measured the concentration in the indoor air. The measurement was measured by dividing it into pre-dismantling and during dismantling.

계층분석법을 이용한 녹색건축 인증제도 평가항목의 중요도 분석 -공동주택 인증기준을 중심으로- (Analyzing Weights of Certification Assessment Criteria on the G-SEED System Using the AHP Method -Focused on Certification Standards for Apartment Buildings-)

  • 최여진
    • KIEAE Journal
    • /
    • 제13권6호
    • /
    • pp.113-120
    • /
    • 2013
  • Many countries over the world have taken many discussions and endeavors on environmental improvements of energy savings and greenhouse gas emission reductions for solving global climate change problems. In Korea, pre-considerations of environment-conscious factors in buildings have been taken to be critical with new constructions and renovation markets. In this situation, the Korean Green Building Certification(KGBC) system to induce the diffusion of sustainable buildings was introduced in 2002 and developed as an improved version of the G-SEED(Green Standard for Energy and Environmental Design) system in 2013 after major revisions. This research examines the importance of assessment criteria on apartment buildings to certify green buildings using the AHP(Analytic Hierarchy Process) method and suggests a new direction on certification assessment standards from the AHP result. In order to apply the AHP method, the survey via e-mail was conducted to design staffs in domestic architectural firms. As a result, assessment criteria such as ecological environment, indoor environment, and energy & environment pollution among 7 main ones proved to be important on assessing the G-SEED system for apartment buildings, while criteria such as land use & transportation, material & resource, water circulation management, maintenance management did relatively unimportant.

다매체/다경로 노출을 고려한 benzo(a)pyrene의 총 인체 노출량 예측 (Estimating Human Exposure to Benzo(a)pyrene through Multimedia/Multiroute Exposure Scenario)

  • 문지영;양지연;임영욱;박성은;신동천
    • Environmental Analysis Health and Toxicology
    • /
    • 제18권4호
    • /
    • pp.255-269
    • /
    • 2003
  • The objective of this study was to estimate human exposure to benzo (a)pyrene through multimedia/multi-pathway exposure scenario. The human exposure scenario for benzo(a)pyrene was consisted of 12 multiple exposure pathways, and the multipathway human exposure model based on this scenario constituted. In this study, the multipathway human exposure model was used to estimate the concentrations in the exposure contact media, human intake factors and lifetime average daily dose (LAD $D_{model}$) of benzo(a)pyrene in the environment. Sensitivity analysis was performed to identify the important parameters and Monte-Carlo simulation was undertaken to examine the uncertainty of the model. The total LAD $D_{model}$ was estimated to be 5.52${\times}$10$^{-7}$ mg/kg-day (2.06${\times}$10$^{-7}$ -8.65${\times}$10$^{-7}$ mg/kg-day) using the multipathway human exposure model. The inhalation dose accounted for 78% of the total LADD, whereas ingestion and dermal contact intake accounted for 20.2% and 1.8% of the total exposure, respectively. Based on the sensitivity analysis, the most significant contributing input parameter was benzo (a)pyrene concentration of ambient air. Consequently, exposure via inhalation in outdoor/indoor air was the highest compared with the exposure via other medium/pathways.

사무공간 적용 BIPV시스템의 자연채광 및 성능평가에 관한 연구 (A Study on Evaluation of Daylighting in Office Space Applied BIPV Systems in Accordance with Power Performance)

  • 서영석;오민석;김회서
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.148-154
    • /
    • 2009
  • By the skyscraper building, increase of skin area and expansion of curtain wall system will be the important factors of acceleration in extending supply of BIPV system. In the future interior environmental evaluation is not a necessary to the residents but an essential term which will bring enormous influence. In the interior environmental evaluation, natural light will let the residents with direct contact with outside circumstances and make them feel opened. also only the daylight has radiant energy and color rendering that will have a great influence to residents' mental, operation efficiency and advancing productivity. This research compares and analyzes BIPC system in office spaces with two general sunlight's module. In addition to natural light's efficiency for BIPC system's comfort and confirmed economical efficiency will be applied to basic research data. Hence forth, ensuring indoor intensity of illumination and controlling light system to reducing energy research data will be demanded to increase the amount of supplying BIPC system. Also continuance research in the possibility of applying BIPC system in various buildings, room temperature affected by location of windows and its condensation, and economical evaluation will be required.

  • PDF

지하에 위치한 방사선종양학과에서의 실내공기 질 평가 (Evaluation of Indoor Air Quality in a Department of Radiation Oncology Located Underground)

  • 김원택;신용철;강동묵;기용간;김동원;권병현
    • Radiation Oncology Journal
    • /
    • 제23권4호
    • /
    • pp.243-252
    • /
    • 2005
  • 목적: 지하에 위치한 방사선치료 관련시설 내의 실내공기 질은 근무자뿐만 아니라 장기간 치료받는 환자들의 건강에도 중요하다. 저자들은 근무자들의 빌딩증후군 증상유무의 확인과 함께 실내공기 질과 관련된 여러 인자들을 측정, 분석하여 그 원인을 찾고 해결책을 제시하고자 하였다. 대상 및 방법: 근무자들을 대상으로 자각증상 및 근무환경 인식과 관련된 설문조사를 하였고, 예비조사를 바탕으로 실내공기 질과 관련된 항목들(온 습도, 미세먼지, 이산화탄소, 일산화탄소, 포름알데히드, 총휘발성유기화합물, 라돈)에 대해 근무자들이 주로 머무르는 지역들을 중심으로 일정기간 측정하였다. 아울러 환기(공조) 시스템의 효율 및 주변 환경에 대한 평가를 동시에 진행하였으며, 실외공기와의 비교평가를 위해 1층(실외)에서도 같은 항목들을 측정하였고, 측정 자료들은 국내외 환경관련 기관들의 권고 수치를 기준으로 각각 평가하였다. 결과: 설문조사에서 근무자들은 악취, 습도, 먼지 등에 대해 불만족을 보였으며, 근골격계 증상, 신경계 증상, 점막 자극 증상 등을 주로 호소하였다. 대부분의 실내공기 질 관련 항목들은 기준치를 넘지 않았으나 총휘발성유기화합물 수치가 기존 미국 사무실 측정 수치에 비해 $3{\sim}4$배 높게 나왔다. 환기 횟수나 환기량에서는 문제가 없었으나 실외공기 유입구와 실내공기 배출구의 위치 문제로 인해 오염된 공기의 유입 가능성이 있었다. 총휘발성유기화합물을 배출할 수 있는 현상액과 같은 화학물질의 관리에 주의가 필요했으며, 오염된 공기의 재유입 문제를 해결하기 위해 환기 시스템의 위치조정이 시급한 상황이었다. 결론: 저자들은 실내공기 질에 대한 평가에서 일부 화학물질 및 부적절한 환기 시스템으로 인해 근무자들이 주관적인 증상을 호소할 수 있음을 확인하였다. 지하 공간에서 장시간 거주하는 근무자들의 근무여건 개선과 함께 면역저하를 동반한 환자들의 건강관리를 위해 실내공기 질에 대한 평가는 반드시 필요하며, 그 자료를 바탕으로 향후 방사선종양학과의 설계나 기존 시설의 환경개선 등에 적극적으로 이용해야 하겠다.

2-Ethylhexyl Diphenyl Phosphate가 제브라피쉬 치어의 발달과 성장호르몬 내분비계에 미치는 영향 (Effects of 2-Ethylhexyl Diphenyl Phosphate on the Development and Growth Hormone Endocrine System in Zebrafish Larvae)

  • 박채운;이다영;지경희
    • 한국환경보건학회지
    • /
    • 제50권3호
    • /
    • pp.212-220
    • /
    • 2024
  • Background: 2-Ethylhexyl diphenyl phosphate (EHDPP) is widely used as a flame-retardant plasticizer in the production of polyvinyl chloride, adhesives, and food packaging. This chemical has been frequently detected in water, sediment, and indoor environments, and its lipophilicity raises concerns about bioaccumulation. Objectives: In this study, the effects of EHDPP on the development, behavioral changes, and growth hormone (GH) endocrine system of zebrafish larvae were investigated. Methods: Fertilized embryos were exposed to various concentrations (control, solvent control, 0.07, 0.7, 7, 70, and 700 ㎍/L) of EHDPP for 96 h. Developmental toxicity endpoints were observed daily. Behavioral changes under light-dark-light conditions and changes in hormones and genes related to GH/insulin-like growth factors (IGFs) axis were determined. Results: Significant decreases in survival, body length and moving distance were observed in zebrafish larvae exposed to 70 and 700 ㎍/L EHDPP. The concentrations of GH and IGF-1 were significantly decreased in zebrafish larvae exposed to 70 and 700 ㎍/L EHDPP. This change was well supported by changes in the transcription of genes involved in GH, IGF, IGF receptors, and IGF binding proteins. Conclusions: Our observations showed that exposure to 70 and 700 ㎍/L EHDPP could disrupt the feedback circuits of the GH/IGFs axis, ultimately leading to developmental toxicity, hypoactivity, and mortality.

나노버블을 이용한 지하철용 전기집진기 포집먼지에 대한 세척효율 평가 (Evaluation of Washing Efficiency of Collective PM by Electrostatic Precipitator in Subway Station Using Nano Bubble)

  • 이형돈;이승환;박찬규
    • 청정기술
    • /
    • 제26권1호
    • /
    • pp.13-21
    • /
    • 2020
  • 지하역사 내 대기오염물질은 외부에서 유입되거나 또는 지하철 내부의 승객 승·하차 시 발생하는 등 여러 가지 요인에 의해 복합적으로 발생한다. 최근 연구 결과에 따르면, 지하역사 내 터널 및 지하철역에서 발생하는 대부분의 대기오염물질은 열차풍에 의해 발생되는 것과 같이 내부적 요인에 많은 영향을 많이 받는 것으로 알려져 있다. 이러한 대기오염물질을 제어하기 위해서는 지하철역사 내에 전기집진장치와 같은 집진시설이 필요하며, 집진장치에 의해 제거된 미세먼지를 보다 효율적으로 관리하기 위해서는 집진장치 내부에 지속적인 세척이 필수적이다. 따라서 본 연구에서는 지하역사에 설치할 전기집진장치 내부 집진판에 쌓인 미세먼지를 세척하기 위한 나노버블세척 장치를 개발하였고 나노버블수의 먼지세척효율을 평가하고자 하였다. 실험 결과, 분사압 증가에 따라 세척 효율이 일정하게 증가하였고 나노버블수로 세척할 경우 수돗물로 세척한 경우보다 부착먼지 제거효율이 130.8% 더 증가하였다. 세척횟수 증가에 따라 최대 제거효율은 수돗물에 비해 143.1% 높았지만 적합한 세척횟수는 3회 미만인 것으로 나타났다. 또한 나노버블수 체류시간 변화에 따른 세척효율 실험결과, 나노버블수의 최대 체류시간은 5분 이내로 유지됨을 확인하였다.

플라스틱온실 내부 환경 인자 다중센서 설치 위치 최적화 전략 (Strategies about Optimal Measurement Matrix of Environment Factors Inside Plastic Greenhouse)

  • 이정규;강동현;오상훈;이동훈
    • 생물환경조절학회지
    • /
    • 제29권2호
    • /
    • pp.161-170
    • /
    • 2020
  • 국내 시설 농업의 99.2%를 차지하는 플라스틱온실의 내부 환경인자는 외부 환경의 변화에 민감하게 반응하고 온실 공간 내부에서 편차가 발생한다. 온도, 습도, CO2, 광도의 환경인자를 계측하기 위한 지점을 3 × 3 × 5로 구성하여 데이터를 취득하고 내부 공간을 수직, 수평적인 측면으로 분할하여 환경 인자의 분포를 확인하였다. 계측지점의 최적점을 선정하고자 계측 공간을 수직, 수평적인 방향으로 분할하고, 측정 데이터와 이를 활용한 예측지점의 선형회귀분석 결과로 성능평가를 실시하였다. 일반적인 상황에서는 온도와 습도 인자의 경우 1개의 센서로 플라스틱온실 내부 환경의 계측이 가능할 수 있으나, 특정구간의 경우 다수의 센서를 활용하여 내부공간의 정밀성을 확보하는 것이 필요하다. CO2의 경우 실험기간 내의 계측 매트릭스의 증가에도 불구하고 변이를 정의하는데 한계가 있음을 발견하였다. 조도 분포의 경우 일출 이후 지속적으로 회귀분석 결과가 작아짐을 발견하였다. 구조물의 간섭 등을 고려해 동일한 수평적인 방향에서 미계측 지점의 결정계수가 감소하였고, 센서 매트릭스 배치를 작물 높이 위로 위치하여 다수의 센서 노드 설치로 개선 가능하다고 예상된다. 외부 환경의 변화에 따라 온실 내부 환경이 불규칙하게 변화되며, 이 구간은 시설의 규격을 고려하여 계측 매트릭스를 구성해야 한다. 반대로 안정적인 구간에서는 최소한의 센서 노드로 내부 환경의 예측이 가능한 것을 확인할 수 있었다. 결과적으로 측정하고자 하는 환경인자와 시설의 구조 등 연구 및 재배자의 목적에 맞는 계측 매트릭스 위치 선정의 유동성이 요구되며, 덕트의 개폐위치를 조절하여 필요한 곳에 에너지를 투입하는 국소냉난방 및 생육제어 모델링 설계에 적용 가능하다고 판단된다.

상업지역 보행가로 내 조명이 야간경관 인식에 미치는 영향 (The Effect of Landscape Lighting in Pedestrian Street on Perception of Nightscape)

  • 송두석;한갑수
    • 한국조경학회지
    • /
    • 제42권5호
    • /
    • pp.41-51
    • /
    • 2014
  • 본 연구의 목적은 보행가로 내의 야간조명의 물리적 특성과 일반인 인식간의 관계를 파악하는 것이었다. 이를 위해 보행가로 내의 야간조명의 물리량을 측정하였으며, 이용자의 이용행태, 야간조명의 만족도 및 야간경관 이미지 평가를 실시하였다. 분석결과, 광원의 면적과 광원 갯수는 구간별로 차이가 크게 나타나지 않았으나, 총량휘도, 평균휘도는 구간별 차이를 보였고, 실내등이 광원의 많은 부분을 차지하였다. 이용자 중 남성, 10대, 학생이, 이용행태별로는 월 1~2회, 18~20시, 모임 목적의 이용자가 타 그룹에 비해 야간조명에 대한 만족도가 높게 나타났다. 야간조명의 물리적 요소 중 광원개수, 광원면적, 최대휘도는 야간조명의 만족도와 야간 경관이미지에 큰 영향을 미치지 않는 것으로 나타났으나, 총량휘도 및 평균휘도는 높은 상관관계를 나타내었다. 즉, 총량휘도 및 평균휘도가 감소할수록 야간조명의 만족도와 함께 경관이미지의 긍정적 평가도 증가하는 것으로 나타나, 향후 야간경관의 정책 수립 시 이를 반영할 필요가 있을 것이다.