• Title/Summary/Keyword: Indoor environmental factors

Search Result 292, Processing Time 0.028 seconds

A Study on Environmental Standards of School Building (교사환경기준에 관한 연구)

  • Hong, Seok-Pyo;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.1
    • /
    • pp.11-43
    • /
    • 2000
  • The purpose of this study was, through analyzing the previous researches, to grasp the present status of environment of school building(ESB), research the sundry records of each element and, through comparative analysis of the standard of ESB in Korea, the United States, and Japan, select the normative standard of ESB, to clarify the point at issue presented in Regulation of Construction & facility Management for Elementary and and Secondary School in Korea, and to suggest an alternative preliminary standard of ESB. To carry out a research for this purpose, these were required: 1. to investigate the existing present status of ESB, 2. to make a comparative analysis of the standard of ESB in each country, 3. to suggest the normative standard of preliminary standard of ESB, 4. to analyze the controversial points of the standard of ESB in Korea, 5. to suggest an alternative preliminary standard of ESB. The conclusions were as follows: 1. Putting, through analyzing the previous researches, the existing present status of ESB together, it seemed that lighting environment, indoor air environment and noise environment were all in poor conditions. 2. In the result of a comparative analysis of the standard of ESB in Korea, Japan and the United States, in Korea the factors of each lighting and indoor air environment were not presented properly, in Japan, in lighting environment aspect, the standard on natural lighting and the factors on brightness were not presented., and in the USA the essential factors of each environment were throughly presented. In the comparison of the standards on each factor, Korea showed that the standard level presented was less properly prescribed than those of the USA and Japan but it also showed that the standard levels prescribed in the USA and in Japan were mostly similar to the standard levels in records investigated. 3. With the result of the normative standard selection on School Builiding environment factor of prescribed in this study, the controversial points of the standard of ESB in Korea were analyzed and the result was utilized to suggest new preliminary standard of ESB. 4. As the result of the analysis of the controversial points of the standard of ESB in Korea, it was found that the standard of ESB in Korea should be established on a basis of School Health Act and be concretely presented in School Health Regulation and School Health Rule. The factors of each environment was improperly presented in the existing standard of ESB in Korea. Moreover the standard of them was inferior to that of the records investigated and those of in the USA and in Japan and it also showed that the standard of it in Korea was improper to maintain Comfortable Learning Environment. 5. A suggested preliminary standard of ESB acquired through above study as follows: 1) In this study a new kind of preliminary standard of ESB is divided into lighting environment, indoor air environment, noise environment, odor environment and for above classification, reasonable factor and standard should be established and the controling way on each standard and countermeasures against it should be considered. 2) In lighting environment, the factors of natural lighting are divided into daylight rate, brightness, glare. In the standard on each factor, daylight rate should secure 5% of a mean daylight rate and 2% of a minimum daylight rate, brightness ratio of maximum illumination to minimum illumination should be under 10:1, and in glare there should not be an occurrence factor from a reflector outside of the classroom. And the factors of unnatural lighting are illumination, brightness, and glare. In the standard on each factor, illumination should be 750 lux or more, brightness ratio should be under 3 to 1, and glare should not occur. And Optimal reflection rate(%) of Colors and Facilities of Classroom which influences lighting environment should be considered. 3) In indoor air environment factors, thermal factors are divided into (1) room temperature, (2) relative humidity, (3) room air movement, (4) radiation heat, and harmful gases (5) CO, (6) $CO_2$ that are proceeded from using the heating fuel such as oval briquettes, firewood, charcoal being used in most of the classroom, and finally (7) dust. In the standard on each factor, the next are necessary; room temperature: $16^{\circ}C{\sim}26^{\circ}C$(summer : $E.T18.9{\sim}23.8^{\circ}C$, winter: $E.T16.7{\sim}21.7^{\circ}C$), relative humidity: $30{\sim}80%$, room air movement: under 0.5m/sec, radiation heat: under $5^{\circ}C$ gap between dry-bulb temperature and wet-bulb temperature, below 1000 ppm of ca and below 10ppm of $CO_2$, dust: below 0.10 $mg/m^3$ of Volume of dust in indoor air, and ventilation standard($CO_2$) for purification of indoor air : once/6 min.(about 7 times/40 min.) in an airtight classroom. 4) In the standard on noise environment, noise level should be under 40 dB(A) and the noise measuring way and the countermeasures against it should be considered. 5) In the standard on odor environment, odor level under Physical Method should be under 2 degrees, and the inspecting way and the countermeasures against it should be considered.

  • PDF

A Study on User Satisfaction of Information Facilities for the Visually Impaired (시각장애인의 실내안내시설 설치 이용만족도에 관한 연구)

  • Kim, In-Bae;Kim, Won-Pil
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.2
    • /
    • pp.19-30
    • /
    • 2020
  • Purpose: The ratio of the visually impaired is gradually increasing due to various causes such as natural aging, accidents, and environmental changes. Therefore, this study has two folds. Firstly, it aims to analyze the current satisfaction level with information facilities for the visually impaired. Secondly, it aims to examine the factors affecting the satisfaction with indoor information facilities. Through this study, it helps to identify problems of information facilities for the visually impaired and it works as a practical data for further improvements. Methods: For 50 visually impaired people, a telephone survey was conducted on the satisfaction with the braille blocks, braille signboards, braille information boards with tactile map, audio guide devices, and safety egress devices. Microsoft Excel and SPSS 26.0 were used for the analysis. Results: It was confirmed that the overall satisfaction with the indoor information facilities was very low. The more the visually impaired people recognized the installation standards, and the better the maintenance was, the higher the satisfaction. In the case of braille blocks and braille signboards, the effect of information transfer on satisfaction was relatively high. In the case of audio guide device and safety egress device, the standard suitability influenced satisfaction. Implications: The low level of satisfaction with the overall information facilities can impede visually impaired people from receiving practical help through the information facilities. Factors influencing the satisfaction level of each facility were identified, which makes it possible to prepare effective improvement measures.

A Study on the Radon Concentration in the Office (사무실 내 라돈 농도에 관한 연구)

  • Choi, Hyun Woo;Kim, Chi-Nyon;Won, Jong-Uk;Kim, Hong-Kwan;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.334-341
    • /
    • 2016
  • Objectives: This study is aimed at examining radon exposure in offices and the factors that can influence the concentrations. Methods: Indoor radon concentrations in a total of 30 places were measured from January 18 to 21, 2016, targeting six buildings in Seoul with different completion years. The measurement was conducted according to the radon measurement guidelines for indoor air suggested by the Ministry of Environment. Results: As a result of comparing each average concentration, underground area concentration was $42.850{\pm}22.501Bq/m^3$, and that of the ground floors was $27.850{\pm}12.232Bq/m^3$, which was lower than the concentration in the underground areas and statistically significant (p=0.045). As a result of comparing the concentration according to whether or not outside air entered, the average concentration for ventilated areas was $24.876{\pm}11.833Bq/m^3$, and the average concentration for enclosed areas was $47.892{\pm}19.375Bq/m^3$. The concentration in ventilated areas was lower at a statistically significant level (p=0.001). Finally, as a result of the multiple regression analysis for evaluating the factors influencing radon concentration, only ventilation was significant (p=0.007). Conclusions: As a result of measuring radon in office buildings, there was no place that exceeding the recommended standard of the US EPA, but the concentration in poorly ventilated areas was measured to be high. An effort to manage radon concentration and reduce it through the improvement of ventilation systems, repeated measurement is necessary in the future.

The Development of Measurement Model for Evaluation of Residential Environment in Low Income Families by LISREL Program (LISREL을 이용한 주거환경 평가 측정모델 개발 -대전시 저소득층을 대상으로-)

  • 최목화
    • Journal of the Korean Home Economics Association
    • /
    • v.33 no.4
    • /
    • pp.157-172
    • /
    • 1995
  • The purpose of this study was to develop a measurement model for evaluation of residential environment in low-income families. Residential environment means the housing unit itself and neighborhoods and community characteristics. Based on the previous research on housing environment, six factors (comfortable environment in indoor and outdoor, facilities environment in complex and community, sociopsychological environment, management and economic environment) were selected to evaluate residential environment and to provided a foundation for exploring the multidimensional factors of this research. As s confirmatory study, an Analysis of Linear Structural Relationships(LISREL) was utilized to develop the model. Despite of some measurement errors, the goodness of fit of an overall model was acceptable. Facilities environment in complex and sociopsychological environment were the most important factors in residential environmental evaluation of the low income families. the findings showed that housing policies and programs to improve the quality of homes in low-income families seemed to be beneficial to improve residential satisfaction of the residents.

  • PDF

Characteristics of Material Damage Caused by Acid Deposition in East Asia

  • Yoo, Young-Eok;Maeda, Yasuaki
    • Journal of Environmental Science International
    • /
    • v.11 no.5
    • /
    • pp.445-454
    • /
    • 2002
  • Material exposure experiments were performed to evaluate the relationship between air pollution and material corrosion rates based on collaboration with researchers in China, Japan, and Korea. Qualitative and quantitative atmospheric corrosion was estimated from damage caused to bronze, copper, steel, marble, cedar, cypress, and lacquer plates exposed to outdoor and indoor conditions in certain East Asian cities. The effects of atmospheric and meteorological factors on the damage to the copper plates and marble pieces were estimated using a regression analysis. The results indicated that sulfur dioxide produced the most destruction of the materials, especially in South Korea and China. In Japan, the copper plates were damaged as a result of natural conditions and sea salt. Copper was also found to be damaged by the surface deposition of sulfur and chlorine. Meanwhile, marble was substantially degraded by gaseous sulfur dioxide, yet sulfate ions in rain had no effect. Accordingly, the analysis of air pollution from the perspective of material damage was determined to be very useful in evaluating and substantiating the intensity of air pollution in East Asia.

The Study on the Environmental Factors of Atopic Dermatitis in Oriental-Western Medicine (아토피 피부염의 환경적 요인에 대한 동서의학적 고찰)

  • Park, Sung-gu;Noh, Hyeon-Min;Kweon, So-Hyoun;Jo, Eun-Hee;Jang, Hyun-Chul;Kim, Ho-kyoung;Park, Hi-Joon;Kim, Won-Jeong;Park, Min-Cheol
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.31 no.1
    • /
    • pp.52-70
    • /
    • 2018
  • Objectives : Atopic dermatitis(AD) and environmental factors are closely related, but there is lack of oriental medical examination. So we compared the relationship between AD and various environmental factors in Oriental medicine and Western medicine. Methods : We described the relationship between AD and environmental factors through the latest papers and a review of the oriental medicine literature. Results : The regional diversity of AD incidence implies a close relationship between climate factors and AD, and high altitude and low pH springs also have an effect on AD. Air pollutants from industrialization and urbanization aggravate AD. The increase in indoor residence time and the increase in room temperature and humidity have also increased the sensitization to allergens such as house dust mite. In oriental medicine, wind(風) is one of the environmental factors and is an inflammatory state due to external irritation. Wind-Humidity(風濕) refers to erythematous wetting dermatitis with itching and exudation, Wind-Fever(風熱) refers to acute inflammatory reaction with erythematous papules and plague, and Blood-Weakness(血虛) refers to aggravation and chronicization of inflammation due to persistence of skin barrier impairment. Conclusions : We examined the relationship between AD and various environmental factors. We also described the oriental medical viewpoints of the environmental factors in the occurrence of AD and skin barrier impairment.

Seasonal and Environmental Influences on Culturable Airborne Fungi Levels in Microbiology Laboratories (미생물 실험실에서의 부유 곰팡이 농도의 계절별 변이와 환경영향)

  • Hwang, Sung Ho;Hong, Sun Yeol;Seok, Ji Won;Yoon, Chung Sik
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.1
    • /
    • pp.19-26
    • /
    • 2016
  • Objectives: This study aimed to assess temporal changes in the level of culturable airborne fungi (CAF) in three microbiology laboratories and determine the environmental factors associated with CAF level. Methods: CAF levels were determined once per month from March 2011 to February 2012 in three microbiology laboratories. An Andersen one-stage sampler was used for five minutes, three times per day to collect the CAF. Arithmetic means of CAF concentrations and standard deviation (SD) were calculated. A Mann-Whitney test was applied to compare the differences between environmental factors such as divided room by structure of laboratory, use of humidifier, and use of air-conditioner. Correlation analysis was also applied to identify the association between CAF concentrations and environmental factors. Results: CAF levels demonstrated an increasing tendency in summer, and the three laboratories showed consistent seasonal patterns. Temperature and relative humidity (RH) were associated with CAF levels. When the humidifier was off, CAF concentrations were significantly higher in study rooms than in study rooms in which the humidifier was on. Conclusion: CAF levels in indoor microbiology laboratories varied greatly depending upon the temperature and RH and whether a humidifier was used.

Characterization of Volatile Organic Compounds associated with Environmental Tobacco Smoke

  • Baek, Sung-Ok;Roger A. Jenkins
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.E
    • /
    • pp.41-58
    • /
    • 1998
  • In this study, a wide range of volatile organic constituents of environmental tobacco smoke (ETS) were determined using an environmental chamber, where ETS is the sole source of target compounds. ETS was generated in an environmental chamber by a number of different cigarettes, including the Kentucky reference cigarette and eight different commercial brands. More than 30 compounds were measured simultaneously for a total of twelve experimental runs. The target compounds are classified into three major classes, i.e. vapor phase ETS markers including 3-ethnylpyridine (3-EP) and nicotine, carbonyl compounds including formaldehyde, and volatile organic compounds (VOCs). The results from the chamber study were used to generate characterized ratios of selected VOCs to 3-EP, a vapor phase ETS marker. Emission factors for VOCs associated with ETS were also estimated. The characteristic ratios appeared to be generally in good agreement with published data obtained by environmental chamber studies similar to this study. This implies that the ratios may be useful for identifying and quantifying the impact of ETS as a source of target compounds in 'real world' indoor environments, which is affected by a complex mixture of multi-sources. The environmental chamber method described here provides a direct and reliable method to compare the ETS generated by different cigarettes. The method can also be applied to the simultaneous determination of many different ETS components.

  • PDF

Evaluation Indicators for Green Libraries and Library Eco-friendliness

  • Noh, Younghee;Ahn, In-Ja
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.8 no.1
    • /
    • pp.51-77
    • /
    • 2018
  • This study aimed to determine eco-friendly factors on the aspects of library service, materials provided or handled by the library, and programs including educational programs. Furthermore, it was setup to perform a trial evaluation for the eco-friendliness of the library based on the determined evaluation standards by this study. Results are as follows; First, regarding the question of 'Do employees of the library think that establishment of green libraries is necessary?', the employees of the libraries responded yes by 65.52%, but only 4.6% responded that it would not be necessary. Second, in analyzing the most important evaluation areas of green libraries according to the opinions of the libraries' employees, they were ranked in order: the indoor environment, energy and prevention of environmental pollution, and material and resource areas. Third, 11 areas were determined to evaluate the level of greening in the libraries; the highest averages were scored 510 for the area of energy and prevention of environmental pollution, 415 for the area of library resource, and 320 for the area of indoor environment. Last, the libraries were graded based on actual data according to the results to measure the level of greening, two libraries were graded as Diamond, the highest grade, accounting for 15.39% of all libraries; Gold and Silver grades accounted for another 15.39%, together five Certified graded libraries accounted for 38.46%, which was the highest rate among the libraries. Any library scoring less than 20% when compared to the full score was graded as Non-certified, and one library, which scored 15.06% fell into this category. The results of this study set up to serve as basic data for the direction of development for green libraries in our country, as well as reference for the employees of libraries in constructing or remodeling library buildings, establishing service infrastructure, providing information service, and planning library duties in an eco-friendly way.

Characteristics of Hazardous Factors Regarding Chemical(Liquid Lime) Storage Tank Dredging Workers (약품(액상소석회) 저장조 준설 작업자의 유해인자 특성 평가 사례)

  • Je-Hun Kim;Ki-Youn Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.1
    • /
    • pp.1-7
    • /
    • 2024
  • Objectives: The study was performed to investigate characteristics of hazardous factors regarding chemical(liquid lime) tank dredging workers by case survey. Methods: Field data such as working condition, MSDS and respirators applied to chemical tank dredging work were analyzed and the work environmental factors of noise and indoor air quality were measured to compare existing data with actual work situations. Results: No health hazards to workers due to working conditions were confirmed during dredging work inside the chemical storage tank. All air quality measurement data during dredging work satisfied the management standards, and there were no by-products. During dredging work, there was a significant change in noise depending on the type of work, but considering the noise reduction rate(NRR) of the earplugs worn by workers, there was no actual health hazard due to noise exposure. Conclusions: A fit test for respirator and the expiration date of the safety helmet should be observed to ensure an appropriate level of safety and health for dredging workers in the chemical storage tank.