• Title/Summary/Keyword: Indoor environmental factors

Search Result 292, Processing Time 0.029 seconds

A Study on the condition of Indoor environmental safety in kindergarten (유아교육기관의 실내 환경 안전 실태에 관한 연구)

  • Choi, Eun-Jin;Han, Hae-Ryon
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2008.05a
    • /
    • pp.242-246
    • /
    • 2008
  • This study is to research on the condition of safe environment of kindergartens. This study is to supplement the preceding study which was based only on survey to show the result and analyze the condition and problems of the safety of kindergartens to suggest the basic database of indoor environment that cause accident. First as a theoretical study, we analyze the preceding studies according to the related regulations. And we made checklist based on this and visited and investigated two kindergartens where applied for the case study As the result, we could understand factors that can cause accidents from classroom, corridor, door, stairs, balustrade, toilet, kitchen, front door, and fire exit/shelter. Especially, in case of fire exit/shelter, the whole renewal of kindergarten was necessary which is difficult. But, though it can not be advanced right away, they should try to have facility expansion and repair works gradually. And for more study on this, active cooperation from kindergartens are in need.

  • PDF

A Study on Indoor Environmental Factors in Elementary School Classroom for Eco-School Planning (에코스쿨 계획을 위한 초등학교 실내 환경계획 요소 조사)

  • Kim, Chang-Sung;Kang, Seung-Ku
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.15 no.6
    • /
    • pp.4-11
    • /
    • 2008
  • Global environment is getting deteriorated at an alarming rate. Eco-school could be one of the effective solutions to protect our environment and a good sample of architecture to economize in total energies, resources and greenhouse gases. In case of our country, the study of eco-school planning is not sufficient compared with other countries, so this paper would be a good study on the indoor environment of the classroom by surveying their opinions and ideas from the group of users in elementary school. The result of this study shows that the proper installation of building equipment and nature ventilation system is necessary to provide delightful environment for the students and to save the energy. To ensure that we have adequate saving and protection, it is necessary to change the existing appraisal standard.

Comprehensive Field Measurement of Indoor Air and Thermal Quality in Naturally Ventilated Office Building with Double-Skin Façade

  • Ito, Kazuhide;Shiraishi, Yasuyuki
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.4
    • /
    • pp.293-314
    • /
    • 2013
  • Double-Skin Façade (DSF), which is a kind of passive indoor environmental control technique, is effective way to control environmental loads while maintaining the transparency especially in perimeter zone and hence the adoption example of DSF keep increasing recently. The objective of this study was to perform a field survey of air quality environment with natural ventilation through DSF and thermal environment within office building with six stories during a mild climate period in Japan. Moreover, to understand the comprehensive environmental performance of the target building, questionnaire survey was conducted to subjectively evaluate the productivity and satisfaction with the environmental factors in office space. In this field measurement, there was a positive correlation between the DSF internal ventilation flow and the amount of solar radiation on the DSF normal surface; the primary driving force for ventilation in the DSF was considered to be the buoyancy force caused by solar radiation. The results of questionnaire survey with regard to productivity level indicated the need for improvement in the thermal (temperature) and spatial environment (room size and furniture placement).

Investigation of school building microclimate using advanced energy equipment: Case study

  • Alwetaishi, Mamdooh;Alzaed, Ali;Sonetti, Giulia;Shrahily, Raid;Jalil, Latif
    • Environmental Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.10-20
    • /
    • 2018
  • Buildings are responsible of major energy consumption globally. In addition, they are linked to thermal comfort. The need to provide comfort becomes more crucial in schools as they are the place where students learn, and develop their skills. This research aims to investigate the energy responsiveness of new and traditional school building design, where major variation in form, amount of external walls and glazing are different. The research focused on indoor microclimate condition of selected schools in the city of Jeddah where the climate is hot and humid using advanced tools for monitoring. The research uses advanced energy equipment to measure several aspects such as floor temperature, roof temperature, globe temperature and other factors which can lead to predictable thermal comfort of users. The findings suggest that a larger area of glazing shielded from sunlight has a greater influence on both indoor condition and general thermal sensation. The finding also suggests that the glazing ratio is a major contributor on indoor thermal pattern which can result in an increase in temperature profile between from $7-10^{\circ}C$. The findings of this research can assist in the improvement in the design of the prototype school building in hot and humid climate.

Indoor air quality evaluation in intercity buses in real time traffic

  • Kazim O. Demirarslan;Serden, Basak
    • Advances in environmental research
    • /
    • v.11 no.1
    • /
    • pp.17-30
    • /
    • 2022
  • Road transport allows all forms of land conditions to be met at less cost. Because of this function, despite numerous disadvantages, it becomes the most frequently used method of transport, especially in underdeveloped or developing countries. One of the most significant factors used in evaluating the atmosphere's air quality is the amount of CO2, increasing people's density in indoor spaces. The amount of CO2 indoors is, therefore, vital to determine. In this study, CO2 and temperature measurements made on nine different bus journey was made in Turkey. The minimum and maximum values were recorded as 555 ppm and 3000 ppm CO2, respectively, in the measurements. On all journeys, the average concentration is 1088.72 ppm. The minimum and maximum values were measured as 17.4℃ and 32.7℃ in the temperature measurements, and the average of all trips was calculated to be 25.76℃. In this study conducted before the Covid-19 pandemic, it was determined that the amount of CO2 increased with the density and insufficient ventilation in the buses. The risk of infection increases in places with high human density and low clean air. For situations such as pandemics, CO2 measurement is a rapid indicator of determining human density.

A Study on Sleep Environment in Bedroom and Segmentation of Sleepers in Seoul and Metropolitan Area (서울시 및 수도권 거주자의 침실환경과 침실 사용자그룹 세분화에 관한 연구)

  • Kim, Bi-Na;Chun, Chung-Yoon
    • Journal of the Korean housing association
    • /
    • v.20 no.1
    • /
    • pp.37-44
    • /
    • 2009
  • Sleep has big influence on our life, for example productivity, character formation of babies, mortality and the people who suffered from sleep problem are also diverse. Therefore, indoor environmental supports for good sleep, might be different with the situation and need of respective person. The objectives of this study are: 1) to investigate the current bedroom condition, sleep problem, and life pattern of Korean. 2) to classify Korean into several groups and explain their characteristics relevant to sleep, in order to understand Korean's need for good sleep. The questionnaire was sent out to Seoul and its environs in Jan.$\sim$Feb. 2008, and total of 702 questionnaires were collected. The research on the bedroom condition was conducted around perceived influence of environmental factors, opening and closing of the door, cooling and heating strategy, clo value during sleep, bedding type, lighting, sharing bedroom. People are divided into 6 groups by 8 factors, and 5 groups could be seen that they need some management for good sleep because of their sleep problem.

The Application of Humidity Indicators for Environmental Measurement Apparatus of Preservation Facility (문화재 보존시설에서의 습도지시카드 적용성 연구)

  • Lim, Bo-A;Shin, Eun-jeong;Do, Min-Hwan
    • 보존과학연구
    • /
    • s.30
    • /
    • pp.47-61
    • /
    • 2009
  • Cultural heritages are affected by various environmental factors. Main factors are temperature, humidity, light and indoor air pollutants such as ozone, nitrogen oxides. Especially humidity condition is very important. Low humidity condition can cause contraction and high humidity condition can lead to growth of microorganism. This study is conducted to appraise an applicability of the Humidity Indicator which is one of the simple method for humidity control. The Humidity Indicator shows the humidity conditions through color change. Therefore, photometer was used to correctly measure the color change of Humidity Indicator. As a result of lab test, Humidity Indicators was stabilized after one hour from en exposure in a certain humidity condition and the indicators indicated clear correlations between color changes of Humidity Indicators and humidity conditions. Some Humidity Indicators which had been selected through the lab tests were applied to preservation facilities of cultural heritages and the indicators indicated closed correlations with humidity conditions in indoor of facilities.

  • PDF

Effect of mold exposure during pregnancy on the development of offspring's atopic dermatitis (임신 중 곰팡이 노출로 아토피피부염 발병에 미치는 영향)

  • Choi, Kil-Yong;Park, Kwang-Sung
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2017.05a
    • /
    • pp.105-106
    • /
    • 2017
  • Background: Atopic dermatitis one of the most common chronic skin diseases, is caused by various environmental and genetic factors. Methods: A total of 2609 healthy newborns who were enrolled in the COCOA study (COCOA) from 2008 to 2015 were surveyed for indoor environmental exposure to fungi during gestation and then diagnosed postnatally for atopic dermatitis. The fungi collected during the gestation of 20 normal subjects and 20 infants that developed atopic dermatitis were identified using Illumina's MiSeq platform and analyzed for their diversity and species. Results: A total of 2,609 respondents were surveyed (52.8% male and 47.2% female) Children, 1, 2, and 3 years old diagnosed with atopic dermatitis comprised 15.2%, 15.7%, and 14.1% of the respondents, respectively. The prevalence of exposure to mold during gestation was 1.46 (95% CI, 1.05-2.04) and 1.52 (95% CI, 0.95-2.43), in the first and third years after birth, respectively. One-year-old children with atopic dermatitis and no fungal markers detected in the bathroom environment during gestation accounted for less than 5% (aOR, 1.51; 95%CI, 0.96-2.38) and in the group less than 5 ~ 30% (aOR, 2.21; 95%CI, 1.00-4.89), 3-year-old children had an increased prevalence of atopic dermatitis of more than 30% (aOR, 9.48, 95%CI 1.42-63.13). Conclusions: Exposure to indoor fungi during gestation and infancy is associated with the development of atopic dermatitis in children. The phyla and genera of the fungi in the indoor house dust differed during gestation. This suggests that exposure to indoor fungi during gestation may be associated with the development of atopic dermatitis in children. Future research will be necessary to establish the underlying mechanisms.

  • PDF

A Study on the Concentrations of Indoor Radon for Houses in Chungcheongbuk-do Province, Korea (충청북도 일부지역 내 주택 실내 라돈 농도)

  • Ji, Hyun-A;Yoo, Ju-Hee;Kim, Ga-Hyun;Won, Soo Ran;Kim, Seonhong;Lee, Jeongsub
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.6
    • /
    • pp.668-674
    • /
    • 2019
  • Objectives: Modern people spend most of their day indoors. As the health impact of radon becomes an issue, public interest also has been growing. The primary route of potential human exposure to radon is inhalation. Long-term exposure to high levels of radon increases the risk of developing lung cancer. Radon exposure is known to be the second-leading cause of lung cancer, following tobacco smoke. This study measures the indoor radon concentrations in detached houses in area A of Chungcheongbuk-do Province considering the construction year, cracks in the houses, the location of installed detectors, and seasonal effects. Methods: The survey was conducted from September 2017 to April 2018 on 1,872 private households located in selected areas in northern Chungcheongbuk-do Province to figure out the year of building construction and the location of detector installed and identify the factors which affect radon concentrations in the air within the building. Radon was measured using a manual alpha track detector (Raduet, Hungary) with a sampling period of longer than 90 days. Results: Indoor radon concentrations in winter within area A was surveyed to be 168.3±193.3 Bq/㎥. There was more than a 2.3 times difference between buildings built before 1979 and those built after 2010. The concentration reached 195.4±221.9 Bq/㎥ for buildings with fractures and 167.2±192.4 Bq/㎥ for buildings without fractures. It was found that detectors installed in household areas with windows exhibited a lower concentration than those installed in concealed spaces. Conclusion: High concentrations of indoor radon were shown when there was a crack in the house. Also, ventilation seems to significantly affect radon concentrations because when the location of the detector in the installed site was near windows compared to an enclosed area, radon concentration variation increased. Therefore, it is considered that radon concentration is lower in summer because natural ventilation occurs more often than in winter.

Effect of environmental relationship between fungal exposure and asthma in children (천식질환이 있는 영유아가 환경요인 중 곰팡이 노출에 따른 영향)

  • Choi, KilYong;Kim, ChaeBong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2018.05a
    • /
    • pp.409-410
    • /
    • 2018
  • Background: Asthma is one of the most common chronic diseases and can be affected by environmental factors. It has been reported that exposure to indoor environmental factors can cause infantile asthma during infancy and childhood, but the previous studies are not yet clear. Climate change has recently been shown to increase indoor mold. Exposure to fungi is known to be directly related to the development of aggravation. Methods: This study was conducted from July 20, 2016 to September 30, 2016. The study was conducted on 90 household with children under the age of 7 who attend atopy school. The questionnaire surveyed allergic symptoms, social and demographic characteristics, and environmental characteristics. Environmentally hazardous substances were measured such as temperature, humidity, fine dust, volatile organic compounds, formaldehyde, bacteria, fungus, house dust mite, endotoxin. Results: According to the survey results, 9 patients (10%) were treated with asthma, 6 (6.7%) were asthmatic patients during the past 12 months, and 4 patients (4.4%) were asthmatic patients during the past 12 months. There were statistically significant differences in the direct effect of smokers in the family (P=0.0328). High-filter vacuum cleaners collected $0.4222CFU/m^3$ in subjects without asthma, and $0.2222CFU/m^3$ in subjects with asthma. In addition, various results confirmed that asthma exacerbated by mold exposure. Conclusions: The results of this study suggest that exposure to fungal by infants and toddlers may play an important role in the development of asthma. In this study, we investigated the relationship between asthma and fungal concentration.

  • PDF