• Title/Summary/Keyword: Indoor Noise

Search Result 429, Processing Time 0.026 seconds

An Experimental Study on Evaluation of the Sound Insulation for Balcony Window in Apartment Houses (공동주택 발코니 창호의 차음성능 평가에 관한 실험적 연구)

  • 김하근
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.11
    • /
    • pp.1137-1146
    • /
    • 2004
  • In an apartment house In Korea, the balcony is one of the important spaces as a buffer zone for controlling the outdoor environments such as noise, heating & cooling load, humidity etc. Because most areas of building facade in apartment building occupy the area of balcony window the sound Insulation design of It Is very Important to provide the quiet indoor environment. The aim of this research is to evaluate the sound insulation of balcony windows in apartment building by new and revised Korean Industrial Standards. We measured and studied the sound insulations of 18 balcony windows by the type of measuring methods, noise sources, correction of reverberation time in balcony and so on. The results show that the single-number quantities for sound insulation of windows are ranged from 24 dB to 30 dB.

A Study on the Development of Lightweight Wall for Sound Transmission Loss and Field Test Results of the Dry-Wall System (차음성능이 향상된 경량벽체 개발 및 성능평가 연구)

  • 이병권;배상환;홍천화
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.699-704
    • /
    • 2004
  • As being inconvenient to apply reinforced concrete structure to high-rise buildings, it is applied steel structured system. Therefore light-weight wall systems are applied as partition wall to reduce the self-load of the building. But, the required performances of a light-weight wall are not evaluated systematically. As a field survey result, partition walls of house-to-house were not showed their respected performances, so the dwellers are feel so worse the quality of the whole building. In steel-structured high-rise buildings especially, occupant's dissatisfaction concerned indoor noise was high because curtain wall systems having a high air-tight performance isolate the outdoor noise making masking effect. Therefore wall systems which have high performances of sound insulation and air-tightness are required in high-rise buildings. As a result, a new drywall system was presented and the performance was verified with field test.

  • PDF

Environmental Noise Assessment of Indoor and Outdoor Units of Air-conditioner (에어컨 실내기의 방사소음과 실외기의 투과소음에 의한 환경소음 예측)

  • 장서일;최진권;손진희;모진용;구형모
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.1
    • /
    • pp.40-47
    • /
    • 2003
  • This study was conducted to determine the sound paths and transmitted sound level in house. An air-conditioner system was selected a typical sound source. The measured transmission loss data shows that the apertures have an significant effect on the transmitted noise and comparable with the existing theoretical data. Therefore the complex aperture was substitute to quantitative apertures approximately. An effective simulation method, ray tracing and mirror image source method, was employed in the prediction of transmitted sound level. The measured results were efficiently reflected on the simulated results. So it is important that measuring the acoustic parameter prior to the prediction of the transmitted sound level in the house.

An experimental study on sound insulation of building elements of the hotel near airport (공항 인근 건물(호텔)에서의 벽체구조의 차음성능에 관한 연구)

  • 이성호;정갑철;양관섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.579-585
    • /
    • 2002
  • This study has measured and evaluated the sound insulation of building elements of the hotel near airport. That measurement was made in both the actual site and laboratory. The differences of sound insulation performance in between granite and double glass were measured. Moreover, the difference of sound insulation was analyzed. For the measurement, this study has tried several methodologies, and analyzed the differences respectively. The results from this analysis were applied to produce a design guides for sound insulation to prevent external noise and to make more silent indoor space which satisfied the standard rate of noise.

  • PDF

The Influence of the Intake Regions of the Cross-flow fan on the Performance and Fan Noise (횡류팬 흡입구의 위치가 성능 및 소음 특성에 미치는 영향)

  • Kim, Jin Baek;Choi, Weon Seok;Lee, Jai Kwon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.78-82
    • /
    • 2004
  • The cross-flow fan which is used for air-conditioner indoor units were studied experimentally. The recent trend shows that the room air-conditioners need to be good-looking. According to the visual design concepts the intake regions of the fan can vary, which leads to the loss of the performance and the increase of the noise of the fan. In order to optimize the performance of the fan and minimize the aerodynamic noise for the system, the performance characteristics and the noise of the cross-flow fan have been investigated at the various conditions of the intake region of the unit.

  • PDF

Experimental Study on Air Flow Characteristics of Axial Dual-blade Fan (축류형 이중 블레이드 팬의 공기 유동 특성에 관한 실험적 연구)

  • Kim, Hae-Ji;Lee, Yong-Min
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.4
    • /
    • pp.113-120
    • /
    • 2014
  • To ventilate indoor spaces, axial single-blade fans are widely used in various areas, such as schools, houses, offices, and restaurants. Recently, axial single-blade fans were developed to realize energy efficiency and noise reduction improvements. Here, an experimental study of the air flow characteristics of an axial dual-blade fan is conducted. The characteristics of the axial dual-blade fan were tested via an air flow analysis and with prototypes. For the performance of the fan, the flow rate, power consumption, and noise were evaluated. The result showed that the axial dual-blade fan uses less power and produces less noise in comparison with an axial single-blade fan.

Detection system of Robust High Frequency Range via Noise Collection and Analysis

  • Chung, Myoungbeom
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.1
    • /
    • pp.71-76
    • /
    • 2017
  • Recently, there are various researches using inaudible high frequencies like as wireless communication based smart devices, data transmission algorithm, indoor positioning trace technologies. However, when they use high frequencies of inaudible range, they have a problem that the accuracy of data transmission with high frequencies was low because of interference from ambient noise in our real life. To solve this problem, in this paper, we proposed an application based on smart phone and server system for collection of ambient noise and detection of robust high frequency range. The server system could detect the robust high frequency range from statistical analysis of collected noise and the robust high frequency could avoid interference from ambient noise. We tested the proposed application's ability to gather noise and high frequencies for a certain period of time to evaluate performance. According to the testing results, we confirmed that the proposed application and server system could detect a robust high-frequency range via noise analysis in real life. Therefore, the proposed application and server could be a useful technology for future research on inaudible high frequencies.

Estimation of the Noise Caused by the System Air Conditioner and its Improvement (시스템 에어컨에 의한 실내 소음 평가 및 개선 설계)

  • Lee, Jea-Won;Joo, Jae-Man;Oh, Sang-Kyong;Song, Yong-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.862-865
    • /
    • 2004
  • The system air conditioner has an outdoor unit and a number of indoor units, which connected by several long pipes. In comparison with building HAVC system, the system air conditioner doesn't need lots of facilities, such as control of room, cooling tower, etc. At the beginning stage for the market of the system air conditioner, its main application was a school which size is small to use the building HAVC and large to use home air conditioning system, such as PAC (package air conditioner), RAC (room air conditioner). Therefore, because of the advantages of the system air conditioner mentioned above, the market is expanded rapidly. Since it is difficult to evaluate the noise caused by the system air conditioner because it has to be implemented before the finish of construction, the prediction or estimation of the noise by using CAE technology should be very important. In this research, using a commercial code, RAYNOISE, the noise is estimated to improve the design of building.

  • PDF

Housing Improvement Elements Depended on the Analysis of Urban Residents' Perceived Korean Housing Quality Related to Mental Health (거주자가 지각한 정신건강 관련 주거의 질 분석에 기초한 주거 개선요소)

  • Choi, Byungsook;Park, Jung-A
    • Journal of the Korean housing association
    • /
    • v.24 no.6
    • /
    • pp.189-197
    • /
    • 2013
  • The purpose of the study was to analyze the improvement elements depended on housing quality measurement tool related to mental health. The data for the analysis was collected through questionnaire survey method from November 1, 2012 to January 17, 2013, and the sample consisted of 720 respondents living in single detached houses, multi-families detached houses, apartments, and town houses in 4 cities, Seoul, Busan, Daejeon, and Kwangju. The data were analyzed using descriptive statistics. The results of improvement elements are as follows: 1) Pedestrian-threaten street from cars in physical safety 2) A secluded or dark spot and fear of walking at night in social security, 3) Indoor noise, outdoor noise, and evidence of abandoned trash heap/bottle in neighborhood in health & sanitation, 4) Illegal parking and heating control system in facility convenience, 5) Extra kitchen, number of bathrooms, and community spaces in space convenience, 6) Openness and spaciousness of indoor room, and satisfaction of house and neighborhood in comfort, 7) Management common/sharing space in maintenance, 8) Energy saving facility and environment friendly materials use in sustainability, 9) Burden on housing cost, asset value on house, and school district in economic value, 10) Reflection of residents style, surrounding building's number of layers, and neighborhood appearance of preference in housing environment image.

Subjective Responses for the Fire Signal Sound of Acoustic Reporting Equipment Depending on Visual Information (시각정보 변화에 따른 음향통보장치 신호음의 청감반응)

  • Song, Hyuk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.3 s.96
    • /
    • pp.313-319
    • /
    • 2005
  • Instruction and prevention of the safety for a fire have been performed continuously by nation. However, the accident due to a fire is not decreasing and causes a serious calamity to people. It is at the initial stage of fire burning that the most effective way to reduce damage is to evacuate and fight a fire. When a fire burns, the equipments reporting to other person or organization concerned are called 'acoustic reporting equipment'. Among those equipments reporting to person, 'a fire bell' is the easiest equipment to approach. Observing the behaviors of people when a fire burning, some are in a quiet indoor, some in a room with other people, some in a square with many people and some in indoor filled with smoke etc. This study aims to find out an acoustic reporting signal appropriate for visual information. For the experiments, visual-auditory experiments were performed through reporting signals and visual informations with several situations that is able to be faced at when a fire burns.