• Title/Summary/Keyword: Indoor Illumination

Search Result 143, Processing Time 0.024 seconds

Supplementation of the Indoor Location Tracking Techniques Based-on Load-Cells Mechanism (로드셀 기반의 실내 위치추적 보완 기법)

  • YI, Nam-Su;Moon, Seung-Jin
    • Journal of Internet Computing and Services
    • /
    • v.17 no.6
    • /
    • pp.1-8
    • /
    • 2016
  • Current indoor intrusion detection and location tracking methods have the weakness in seamless operations in tracking the objective because the object must possess a communicating device and the limitation of the single cell size (approximate $100cm{\times}100cm$) exits. Also, the utilization of CCTV technologies show the shortcomings in tracking when the object disappear the area where the CCTV is not installed or illumination is not enough for capturing the scene (e.g. where the context-awarded system is not installed or low illumination presents). Therefore, in this paper we present an improved in-door tracking system based on sensor networks. Such system is built on a simulated scenario and enables us to detect and extend the area of surveillance as well as actively responding the emergency situation. Through simulated studies, we have demonstrated that the proposed system is capable of supplementing the shortcomings of signal cutting, and of estimating the location of the moving object. We expect the study will improve the better analysis of the intruder behavior, the more effective prevention and flexible response to various emergency situations.

Improvements in Solar Cell Efficiency using a PMMA Concentrator Lens for Indoor Use (실내조명 응용을 위한 투명 집광 렌즈를 이용한 태양전지 효율 향상)

  • Lee, Yoo-Jong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.4
    • /
    • pp.929-934
    • /
    • 2010
  • Improvements in characteristics of a single junction AlGaAs/GaAs solar cell are observed by capping a PMMA lens on it. In order to show the effect of the lens, characteristics of a single junction AlGaAs/GaAs solar cell before and after the lens formation are compared under the one-sun illumination condition ($100mW/cm^2$). Characteristics of the solar cell under very weak illumination condition (about 1200 lux) is also measured with the lighting of a fluorescent desk lamp. About 5% of cell efficiency is improved after the capping of PMMA lens on the single junction AlGaAs solar cell and $83\;{\mu}m/cm^2$ of electrical power was generated with the lighting of a desk lamp.

Indoor Location-based Emergency Call Service System for Ships using VLC Technology (가시광통신을 이용한 선박 내 위치 기반 응급호출 시스템)

  • Hong, Seung-Beom;Lee, Kyou-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.12
    • /
    • pp.2836-2843
    • /
    • 2015
  • Due to metallicity of materials, a vessel has a limitation to adopt RF-based wireless communication technologies for the inner communication means. Visible Light Communication(VLC) can be a sound alternative to dissolve such a limitation. Using a visual light as a transmission medium, VLC is free from radio interferences and restriction of radio usages which are typically related to RF-based wireless communications. In addition, VLC can not only require the facility cost relatively low because of being possibly converged with existing LED illumination, but also be harmless to the human body. This paper proposes an indoor location-based emergency call service system solution for ships using the VLC technology that supports 256Kbps data rate and 5m transmission distance. This paper presents real implementation and testing results of the solution which verifies the propriety of the proposal.

Design of Neuro-Fuzzy LED Emotional Lighting System for Concentration and Resting Situations in Indoor Environment (실내 환경 집중 및 휴식상황에서의 뉴로-퍼지를 통한 LED 감성조명 시스템 설계)

  • Kang, Eun-Yeong;Kim, Hyo-Jun;Park, Keon-Jun;Kim, Young-Kab
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.3
    • /
    • pp.558-566
    • /
    • 2015
  • LED, the next-generation light source, rapidly develops and has advantages of low power, high efficiency, and long life. Accordingly, an interest in lightings by using LED rises. If emotional lighting is implemented by using LED, all colors can be represented by using 3 primary colors of light, differently from the conventional single-color lighting. LED emotional lightings which can control human emotions continue to be developed thanks to these advantages. This study was conducted to design an algorithm for expressing LED emotional lighting in line with the situation and temperature by extracting colors for concentration and resting situations in indoor environment and mixing them with colors of the temperature felt by user. The LED emotional lighting designed with a neuro-fuzzy system was found to have effects on user's emotions during concentration and resting.

Daylighting Performance Evaluation of Light-shelf according to the Reflectivity - Focused on the Residing space - (반사율에 따른 광선반 채광 성능평가 연구 - 주거공간을 중심으로 -)

  • Heo, Doyeon;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.15 no.3
    • /
    • pp.49-56
    • /
    • 2015
  • Purpose: Due to recent increase on energy consumption for light in building, many studies to mitigate this issue have been conducted. Various researches have been carried out to suggest light shelf as one of the solutions, but researches for its reflectivity is very few. In fact, existing research on light shelf shows that utilizing more than 90% of high-illumination materials causes imbalance of glare and illuminance. Method: Therefore this research aimed to evaluate the performance of light shelves depending on reflectivity and to identify proper solution through test-bed. Result: The results are following: 1) Increased reflectivity generally contributed to increase of indoor illuminance but degrade uniformity factor related with indoor comfort of light environment. 2) The $0^{\circ}fixed$ light shelf with 75% of reflectivity and width of 300mm and 40mm appeared to consume more energy than other shelves. Therefore, it is analyzed as unsuitable. 3) This research was conducted by calculating appropriate angle of light shelf around winter and summer solstices and vernal/autumnal equinox. Based on this, performance evaluation was undertaken depending on reflectivity of movable light shelf, which is activated by external sources and can be applied with lower reflectivity than fixed shelf. However, one exception was a movable shelf with width of 600mm that increased light energy consumption when 75% of reflectivity was applied. 4) Performance evaluation of fixed and movable light shelf showed that the shelf with 80% of reflectivity came up with suitable results, but 75% of reflectivity may be applied depending on the width and angle of the shelf. This research is meaningful in that estimation of appropriate reflectivity of light shelf can resolve the glare problem and improve light environment, and further research would be desirable under more diverse conditions to identify proper solution.

The Visual Performance Evaluation of the Work planes with the Automated blind Control in Small Office Spaces

  • Park, Doo-Yong;Yoon, Kap-Chun;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • Among the various building envelope elements, the glass area takes up the largest portion in the office building design. However, a large area of glass can cause problems such as excessive solar radiation, thermal comfort, and glare. Thus it is important to install the glass area to an appropriate level, and control solar radiation and inflow of daylight with blind devices. This study aims to improve the visual performance of the work plane through the automatic control of the venetian blinds. A total of eight kinds of control strategies were chosen; Case 1 does not control the blinds, Case 2 with the blind slats fixed at the angle of 0 degree, Case 3 to 6 using the existing blind control programs, and Case 7 and 8 with improved blind control. Case 3 with 90 degrees had the best energy performance, but the average indoor illuminance was 113lux, which is below the standards. Cases 4 and 5 showed higher levels of interior daylight illuminance with the average of 281lux and 403lux respectively. However, the fixed angles may have difficulties controlling excessive direct sunlight coming into the room and may cause glare. Cases 6 and 7 used sun tracking angle control and cut-off angle control, and the average interior illuminance was measured 250lux and 385lux respectively. Case 8 used the cut-off angle control in an hourly manner, satisfying the standard illuminance of 400lux with an average interior illuminance of 561lux. It was evaluated to be the best method to control direct solar radiation and to guarantee proper level of interior illumination.

The Related Factor on a Work Environment of Hairdressers and a Subjective Symptom of Respiratory Organ (미용사들의 작업환경과 호흡기 자각증상과의 관련요인)

  • Lee, Gye-Suk;Lee, Myoung-Hee
    • Korean Journal of Human Ecology
    • /
    • v.17 no.6
    • /
    • pp.1215-1224
    • /
    • 2008
  • This research has measured the indoor environment of thirty hair salons, which are located on Gunsan-Si, Jeonlabbuk-Do, from April 1st to April 30th 2005, to examine the related factors on a work environment of hairdressers and a revelation of respiratory symptom, and has polled 260 hairdressers and 350 office workers. After measuring the physical environment of hair salons, the room temperature, the relative humidity and the illumination was in an agreeable range, and 60 percent of hair salons depended on the natural ventilation through the windows. The levels of acetone, toluene and xylene, which were measured at the hair salons, were all under the safety standards (p<0.05), but these are still harmful and volatile matters, so they can be bad for your health by the contact of skin and respiration. The harmful factors that affect a revelation of respiratory symptom were the group who has many exposures of permanent wave or bleaching/dyeing and not many experiences of hairdressing work, the group who smokes every day, and the group who never exercises at all (p<0.05). This result shows that there are possibilities of health problem for hairdressers from the constant and repeating hairdressing works with the exposure of chemicals such as the permanent, bleaching and dyeing. so that hairdressers recognize that they need appropriate ventilation facilities for their agreeable indoor-environments. And also, to prevent the direct exposure of chemicals as much as they can, they need to have an active management of an individual health care by wearing gloves, mask or something like that.

Simulation Study on the Performance Evaluation of Light-shelf According to Geometric Shape of Ceiling (천장의 기하학적 형태에 따른 광선반 성능평가 시뮬레이션 연구)

  • Lee, Henagwoo;Kim, Yongseong;Seo, Janghoo;Kim, Duk-Su
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.4
    • /
    • pp.181-192
    • /
    • 2014
  • Light-shelf is one of the most efficient natural lighting systems due to the improved function of the inflow level of the outdoor natural light. However, the existing research on the light shelf limits to the rectangular parallelepiped space, so do not provide sufficient data for various shapes of spaces. Thus, this study aims at deriving proper plan and relationship of the light shelf through its performance assessment depending on the indoor space shapes and utilizing them as basic data of light shelf design. The conclusions are as follows : 1) for 6m space depth, standard intensity of illumination satisfaction depth has shown 8.3%~26.3% improvement through the adjustment of the angle and width when installing light shelf compared to no light shelf installation; 2) $-30^{\circ}$, $-20^{\circ}$ and $-10^{\circ}$ light shelves set by this study play only as a blind regardless of the shape of ceiling on the summer solstice, and it is unsuitable; and 3) this study has derived proper plan of light shelf upon space shapes based on energy reduction and indoor evenness. The study results provide expanded data of the performance assessment of the light shelves according to the different space shapes and light shelf factors, which serves as a basis of the light shelves designing.

A Study on Lighting Performance Evaluation of Light-Shelf using Crystal Face (결정면 적용 광선반 채광성능 평가 연구)

  • Lee, Heangwoo;Rogers, Kyle Eric;Seo, Janghoo;Kim, Yongseong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.8
    • /
    • pp.395-401
    • /
    • 2015
  • Recently, many research studies have been carried out on the efficiency of light-shelf daylighting systems, especially comparing performance improvements and the limitations of reflective surfaces and their lighting performance. In this study, a crystal face reflective surface is proposed. The objective of the study is to evaluate the lighting performance of a crystal face light-shelf through a performance study. The performance study was carried out in a full scale test-bed in order to calculate the light distribution and energy consumption utilizing the standard indoor illumination as an index. The conclusions of the performance study are as follows. 1) The optimal angle of incidence for daylighting for both the operable flat type light-shelf and the crystal face light-shelf are taken in the natural environment on the dates of the winter and summer solstices, as well as the autumn and spring equinoxes. 2) The application and installation of the crystal face light-shelf can produce a 29.9%~34.3% increase of light distribution within the indoor space. However, the increase of light distribution can also lead to a decrease in the uniformity ratio, a design challenge that should be considered when applying a crystal face light-shelf. 3) It is possible to achieve a 7.98%~13.3% greater reduction in energy consumption when applying a crystal face light-shelf than when applying a flat type light-shelf. The increase in the number of crystal faces should concur with the analysis of the energy reduction. A limitation of the study is that only one predetermined pattern was performance tested for a crystal face light-shelf. In order to carry out further research on crystal face light-shelves, additional performance studies are needed based on alternative patterns and designs.

Inactivation influences on Escherichia coli DS5α by irradiation with 405 nm violet-light

  • Young-Sun Kim;Mun-Jin Choi;Dae-Young Lee;Sang-Ook Kang;Geung-Joo Lee
    • Korean Journal of Agricultural Science
    • /
    • v.50 no.3
    • /
    • pp.417-425
    • /
    • 2023
  • Because an irradiation of 405 nm violet light could have a strong energy, it was used to be sterilized against various microbes in the indoor air condition or fresh food. Escherichia coli is a representative bio-pollutant in the indoor air-borne bacteria, and a hygienic microbe in the horticultural food. This study evaluated the inactivation influences on E. coli DS5α after exposure to 405 nm violet-light (VL) by investigating irradiating time, and the vertical and horizonal distance from light source. The illumination of 405 nm VL was inversely proportional to the distance from the VL source. E. coli DS5α on nutrient agar (NA) was inactivated approximately 50% more than the control when irradiated at 65 cm from 405 nm VL for 3 hours. When compared to the control, E. coli DS5α was inactivated approximately 50% within 70 cm from 405 nm VL for 3 hours. As it was irradiated for 3 hours 70 cm away from 405 nm VL, the horizonal distance from the point was negatively correlated to the inactivation of E. coli DS5α. These results indicated that the inactivation of E. coli DS5α grown on NA medium needs to be irradiated with 405 nm within 70 cm from the light source for 3 hours.