• Title/Summary/Keyword: Indoor Experiment

Search Result 554, Processing Time 0.024 seconds

Adsorption Properties of Cellular Light-weight Concrete using Rice Husks (왕겨숯을 이용한 경량기포콘크리트의 흡착 특성)

  • Lee, Chang-Woo;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.146-147
    • /
    • 2021
  • An increase in carbon emissions leads to the problem of global warming and is an issue to be solved in other countries. The problem of carbon dioxide has many effects not only on global warming but also on people. According to the World Health Organization (WHO), 4.3 million people have died because harmful substances generated indoors cannot be discharged to the outside and accumulate in the human body through the respiratory tract. In response to this situation, in order to reduce the generation of pollutants in the building itself, soak into lightweight bubble concrete to adsorb and purify indoor pollutants, mix charcoal, investigate the appropriate amount and physical characteristics, and check carbon dioxide This is an experiment for grasping the adsorption capacity, and the results are as follows. As the replacement rate of rice husk charcoal increased, the compressive strength tended to decrease, and the carbon dioxide reduction rate tended to increase. It is judged that the charcoal of rice husks shows a low density and the physical adsorption is smooth due to the porous structure. Since it is excellent in the basic physical properties and carbon dioxide adsorption surface of this experiment, it is judged that it has sufficient potential for use as an indoor finishing material.

  • PDF

The Development and Application of Textbook Relevant to School Indoor Air Quality - Focused on 5th, 6th Grade Students - (학교 실내 공기질 관련 초등환경교육 교재 개발 - 5, 6학년을 중심으로 -)

  • Lee, Mi-Ae;Moon, Yun-Seob;Hwang, Eun-Ja
    • Hwankyungkyoyuk
    • /
    • v.21 no.4
    • /
    • pp.40-66
    • /
    • 2008
  • The purpose of this study is to develop and applicate textbook relevant to school indoor air quality. To achieve the purpose, concrete study process are as follows. First, the survey research to teachers, supervisors, and students is conducted to grasp cognition of subjects in elementary school and management situation about school indoor air quality. Second, contents relevant to indoor air quality on textbooks in the 7th elementary curriculum and subsidiary textbooks is analysed through reference study. Third, environmental textbook relevant to school indoor air quality for 5th and 6th grade in elementary school is developed, applicated, and inspected its effect on the basis of implications from results of survey and reference study. The results of this study are as follows. First, the result of survey concerning school indoor air quality showed that three groups had negative attitude for its management even though they thought that it affected human's health and study by and large. Student group thought that each of students itself was a little influence to school indoor air pollution though all of three groups answered that' activities of students' was its main source. Efforts of students to improve school indoor air quality was not much, and its main reason was that they didn't know about school indoor air pollution well. Second, result of analysis into textbooks on the 7th elementary curriculum and subsidiary textbooks, contents concerning indoor air on the 7th elementary curriculum textbooks was little or nothing. And it trended to be included to subsidiary textbooks. However, education textbooks about indoor air for elementary students was insufficient still. Third, environmental textbook relevant to school indoor air quality for 5th and 6th grade in elementary school was developed. It was constructed for themes - importance, sources, effects, and management of school indoor air quality. After its application to the 6th grade students in elementary school, it was meaningful in the level of p<.05 that the result of knowledge and awareness in the pre-post test within experiment group. However, all of the results in comparison group didn't represent statistically meaningful difference. In conclusion, environmental textbook developed by necessity of education about school indoor air quality will play a role as useful tool for the 5th, 6th grade students in elementary school to understand relation of quality of health and life and school indoor air quality, to have attitude to make an effort to manage it by develop right awareness about it.

  • PDF

Wi-Fi Line-of-Sight Signal based Indoor Localization Method Using Smartphone and Two Dual-band APs (2개의 이중대역 AP와 스마트폰을 이용한 Wi-Fi LOS 신호 기반의 실내 측위 기법)

  • Jo, Hyeonjeong;An, Hyunseong;Kim, Seungku
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.5
    • /
    • pp.583-591
    • /
    • 2018
  • With the development of ICT(Information and Communication Technology), the number of smart devices is rapidly increasing. LBS(Location Based Service) applications that provide user's location based service are used in various fields. There is also a growing demand for indoor precision positioning technology to provide seamless services. In this paper, we propose an indoor positioning system that estimates the location of a smartphone user. The proposed algorithm determines whether the received signal is LOS(Line-of-Sight) or NLOS(Non-Line of-Sight) in order to decrease multipath effect by the indoor environment. The proposed positioning algorithm is very simple and requires only the AP(Access Point) coordinates. In addition, it requires only two APs for estimating the location of a smartphone user. The proposed algorithm is a practically applicable technology without any additional hardware and kernel modification in the smartphone. In the experiment results, the reliability of the positioning system was found to be within 0.83 m.

Wireless LAN-Based User Tracking Method and Experiment for Location-Based Services (위치기반서비스를 위한 무선 근거리통신망 기반의 사용자 추적방법 및 실험)

  • Yim, Jae-Geol;Joo, Jae-Hun;Jeong, Seun-Ghwan
    • The Journal of Society for e-Business Studies
    • /
    • v.13 no.4
    • /
    • pp.1-16
    • /
    • 2008
  • LBS (Location Based Service) cannot be realized unless we can obtain the user's current location. Therefore, in order to realize indoor LBS, many researchers have been working on WLAN (Wireless Local Area Network) based indoor positioning and tracking. Meanwhile, Kalman filter has been widely used in the field of GPS based outdoor user tracking. The main purpose of this paper is proposing an extended Kalman filter method for indoor tracking. Our experimental results show that Kalman filter can be used to improve the accuracy of the measured tracks and the track can be further improved by making use of the map information.

  • PDF

Diurnal Variation of $PM_{10}$ Concentrations in Library and Student Buildings using Scattering Light Integrated Type Digital Dust Indicator (산란광 광량 적산시 Digital Dust Indicator에 의한 도서관과 학생회관내 $PM_{10}$ 농도의 일변화)

  • 김만구;권영진;정영림
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.2
    • /
    • pp.115-122
    • /
    • 1997
  • Diurnal variation of $PM_{10}$ concentration was investigated for 24 sites in library including reading room, bookstock room, lobby, office and so on, and 9 sites in student building at Kangwon National University using scattering light integrated type digital dust indicator. The dimensional conversion factors for mass concentrations (K) were determined by comparing between the $PM_{10}$ concentrations collected by $PM_{10}$ hig volume air sampler and the digital dust indicator. The dimensional conversion factor (K) was 3.33 for indoor air in this experiment. The highest concentrations were 649 $\mug/m^3$/day for smoking room in the library and 242 $\mug/m^3$/day for circle room in the student building. Most of spaces in the library except a office and bookstock rooms were over 150 $\mug/m^3$/day of $PM_{10}$ concentrations and 6 indoor spaces were over the guideline for indoor air quality in student building except a health center and two restaurants. Therefore, it should be required to make an improvement on the indoor air quaility for public facilities in the university buildings.

  • PDF

Pproperties of formaldehyde and CO2 adsorption type matrix using TiO2 photocatalysis (광촉매를 활용한 흡착형 경화체의 포름알데히드 및 CO2 특성)

  • Lee, Won-Gyu;Pyeon, Su-Jeong;Kyoung, In-Soo;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.153-154
    • /
    • 2018
  • As the air pollution progresses, the pollution degree of the indoor air quality is increased, and when the pollution degree of the indoor air quality is increased, it causes respiratory diseases and skin diseases. In addition, volatile organic compounds are released from the materials used for architectural interior decoration, and volatile organic compounds are the main cause of polluting indoor air quality. In order to improve indoor air quality, we tried to secure indoor air quality pollution by using photocatalyst which has the function of decomposing harmful substances. photocatalyst is a material that promotes chemical reaction by absorbing light. The photocatalyst used in the experiment was TiO2, In this study, an adsorption type hardener for reducing volatile organic compounds was prepared by photocatalytic reaction. the formaldehyde and CO2 concentrations of the cured products were analyzed according to the TiO2 content.

  • PDF

Properties of Water-based Paint mixed with Photocatalyst for Indoor Air Quality Improvement (실내 공기질 개선을 위한 광촉매를 혼입한 수성도료의 특성)

  • Choi, Byung-Cheol;Park, Chae-Wool;Kyoung, In-Su;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.29-30
    • /
    • 2020
  • As the modern society enters, the building becomes sealed and the public's interest in the environment increases, so the interest in indoor air pollution increases and the environmental pollution is raised as an important issue not only outdoors but also indoors. In addition, the emergence of sick house syndrome (SHS) has increased the interest in formaldehyde and is a cause of deteriorating indoor air quality. Accordingly, this study prepared a functional paint by incorporating a photocatalyst in an aqueous paint, and conducted formaldehyde adsorption experiments and functional evaluation. As a result of the experiment, as the photocatalyst was added, the formaldehyde adsorption performance tended to increase. In addition, as a result of measuring the impact resistance and alkali resistance according to the KS standard, there is no difference in residual cracks and cracks between the water-based paint without the photocatalyst and the water-based paint with the photocatalyst added. Therefore, it is considered that the water-based paint added with a photocatalyst can improve the indoor air quality by adsorbing formaldehyde and can be used as a functional paint because the functionality is not different from that of a general water-based paint.

  • PDF

Effects of Housing Systems on Behaviour, Performance and Welfare of Fast-growing Broilers

  • Zhao, Zi-Guang;Li, Jian-Hong;Li, Xiang;Bao, Jun
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.1
    • /
    • pp.140-146
    • /
    • 2014
  • This experiment aimed to evaluate the effects of different housing systems on behavioral activities, welfare and meat quality of fast-growing broilers. Two hundred broilers were allocated into two housing systems: indoor housing vs indoor with outdoor access. Their general behavior (feeding, drinking, fighting, standing, lying, walking, investigating, dust-bathing and preening) was observed, and tonic immobility, fluctuating asymmetry of legs and wings were measured, and meat quality was analyzed. The results showed that the indoor-housed broilers with outdoor access had significant higher standing, walking, investigating, dust-bathing and preening than those indoor only. However, farming system was not found to significantly affect their feeding, drinking and fighting activities (p>0.05). The value of FA of tibia length of the broilers with outdoor access was significantly lower than that of the indoor-housed birds ($1.57{\pm}1.30$ vs $2.76{\pm}1.40$, p<0.05), while no difference was found for the value of FA in tibia diameter and wing length (p>0.05). TI of the broilers with outdoor access was 165.5 that was significantly higher than that (147.2) of the indoor birds (p<0.05). However, death rate in the outdoor run groups was significantly higher than that of the indoor ones ($2.0{\pm}0.81$ vs $4.0{\pm}0.82$, p<0.05). Meat quality was not affected by the two farming systems. It can be concluded that the results of this study may suggest that the indoor housing with outdoor access provides enriched environment for broilers and facilitates the expression of natural behaviors of the broilers but resulted in poorer performance and higher death rate.

Experimental Study on Heating Performance by Operation Combination of Heat Pump with 3 Indoor-Units (3실 열펌프의 운전조합에 대한 난방성능 실험연구)

  • Kim, Ju-Hyung;Kim, Ki-Young;Kwon, Young-Chul;Park, Seung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4197-4203
    • /
    • 2013
  • In order to investigate the heating performance of multi-heat pump applying an inverter compressor, the experiment on heat pump with 3 indoor units was performed under the heating standard and heating low-temperature conditions. The performance data of heat pump with 3 indoor units were measured by the multi-psychrometric calorimeter. The operation characteristics and the behavior of the refrigerant cycle of the heat pump with 3 indoor units were understood from the heating capacity, heating COP, and P-h diagram by indoor-unit combination. The present experimental results show that the operating load and performance of the multi-heat pump depends on the indoor-unit combination. The heating capacity and heating COP of the low temperature condition were smaller than those of the standard one. Also the refrigerant cycles on indoor-unit combination were analyzed by using P-h diagram.

Development of comfort algorism for Indoor temperature chagne in Heating System (변동환경 대응을 위한 난방System의 쾌적 알고리즘 개발)

  • Kim, Dong-Gyu;Jeong, Yong-Hyun;Kum, Jong-Soo
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.18 no.3
    • /
    • pp.229-235
    • /
    • 2006
  • This study investigated physiology and psychological response of subjects, when heat pump was operated long time within comfort temperature range. Eight subjects were participated for the experiment. Their age was from 22 to 25 years old. The results of this experiment will propose basic data for improving comfort control algorithm in fluctuating environment by using heat pump. When indoor temperature was controlled by heat pump, the conclusion was as follows. 1) When votes of subjects was considered, the thermal comfort neutrality or lower range helped formation of comfort sensation for subjects. 2) When room temperature was lower, thermal comforts of shoulder, knee and foot with subjects thermal comfort showed high correlation. And when room temperature was higher, thermal comfort of face region with subjects thermal comfort showed high correlation. 3) The necessity of temperature change after 50 minutes from initially operating heat pump demands the additional analysis against the physiological signal.