• Title/Summary/Keyword: Indoor Corridor Environments

Search Result 21, Processing Time 0.025 seconds

Prediction and Analysis of the Propagation Characteristics in Indoor Environments (실내 환경의 전파특성 예측과 분석)

  • 손호경;김성진김채영
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.169-172
    • /
    • 1998
  • A 3D-ray tracing using triangular ray tubes for predicting propagation in indoor environments is presented. Employed ray tracing scheme needs no reception sphere often suffered from how to assign the correct radius as a touching ray on the receiver. To verify the developed codes path loss for a rectangular corridor has been computed, measured, and compared with those by image methods, all shows good agreement to each other. Discussions are made on the path loss fluctuations along the distance in a rectangular corridor having a conducting knife.

  • PDF

Indoor Autonomous Driving through Parallel Reinforcement Learning of Virtual and Real Environments (가상 환경과 실제 환경의 병행 강화학습을 통한 실내 자율주행)

  • Jeong, Yuseok;Lee, Chang Woo
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.26 no.4
    • /
    • pp.11-18
    • /
    • 2021
  • We propose a method that combines learning in a virtual environment and a real environment for indoor autonomous driving through reinforcement learning. In case of learning only in the real environment, it takes about 80 hours, but in case of learning in both the real and virtual environments, it takes 40 hours. There is an advantage in that it is possible to obtain optimized parameters through various experiments through fast learning while learning in a virtual environment and a real environment in parallel. After configuring a virtual environment using indoor hallway images, prior learning was carried out on the desktop, and learning in the real environment was conducted by connecting various sensors based on Jetson Xavier. In addition, in order to solve the accuracy problem according to the repeated texture of the indoor corridor environment, it was possible to determine the corridor wall object and increase the accuracy by learning the feature point detection that emphasizes the lower line of the corridor wall. As the learning progresses, the experimental vehicle drives based on the center of the corridor in an indoor corridor environment and moves through an average of 70 steering commands.

Development of Propagation Loss Prediction Software for the Indoor V-Band Millimeterwave Communication Environments (V-밴드 밀리미터파 대역의 실내 통신환경 분석을 위한 경로손실 예측 소프트웨어 개발)

  • Chun, Joong-Chang
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.1 no.1
    • /
    • pp.35-39
    • /
    • 2008
  • In this paper, we have developed a propagation loss prediction software with GUI (Graphic User Interface) functions, based on the geometrical ray optics model, which can predict radio parameters for the deployment of wireless indoor network. The program has two numerical modules consisted with electrical image and ray launching methods to implement UTD theory. The simulated results are compared with reported data measured in the foreign building environments for office and '一' type corridor, and measured and simulated results for the propagation loss agree with each other quite well. Simulation results for '一' type corridor and 'T' type corridor propagation environment are shown for reference.

  • PDF

Measurement and Comparative Analysis of Propagation Characteristics in 3, 6, 10, and 17 GHz in Two Different Indoor Corridors (두 가지 서로 다른 실내 복도에서 3, 6, 10, 17 GHz의 전파 특성 측정 및 비교 분석)

  • Seong-Hun Lee;Byung-Lok Cho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.6
    • /
    • pp.1031-1040
    • /
    • 2023
  • Propagation characteristics in line-of-sight(LOS) paths in 3, 6, 10, and 17 GHz frequency bands were measured and analyzed in two different indoor corridors: second floors of Buildings D2 and E2. The measurement was designed to measure when the receiving antenna moved at 0.5 m intervals from 3 m to 30 m, while the transmission antenna was fixed. The analysis of the two indoor corridors was compared by applying basic transmission loss, root mean square (RMS) delay spread, and K-factor. For basic transmission loss, the loss coefficient of the floating intercept path loss model was higher in the indoor corridor of Building E2 than in that of Building D2. Similarly, the RMS delay spread in the time domain was greater in the indoor corridor of Building E2. However, the indoor corridor of Building D2 exhibited higher K-factor in the 3, 6, and 17 GHz bands with lower wave propagation in the 10 GHz band. Despite the 2 indoor corridors being identical, the propagation characteristics varied due to different internal structures and materials. The results provide measurement data for ITU-R Recommendations regarding various indoor environments.

A Study on the Characteristics of Heavy Metal Concentration and Indoor Atmospheric Environments ; Heavy Metal Concentration in School Environments (실내 대기환경과 중금속농도의 분포특성에 관한 연구 - 학교 환경의 중금속농도)

  • 박종길;장난심
    • Journal of Environmental Science International
    • /
    • v.6 no.5
    • /
    • pp.451-459
    • /
    • 1997
  • This paper alms to describe the indoor-outdoor air quality in school environment through the analyses of heavy metal concentration by inductively Coupled Plasma(ICPI, which were observed at some school environment, such as traffic area, industrial area seme-industrial area, and residence area. The results are as follows : (1) Regardless Indoor and outdoor, the area with the highest concentration of heavy metal is industrial area followed by traffic area, residence area and semi-industrial area in descending order of magnitude. And the heavy metal concentration of indoor is higher than that of outdoor. (2) The main heavy metal components with more high level concentration of Indoor than those of outdoor are Zn, Al, Ca and these heavy metal concentrations are higher in class than In corridor and outdoor.

  • PDF

Characteristics of Heavy Metal Concentrations and Indoor Atmospheric Environments in Busan Metropolitan Area, Korea

  • Park, Jong-Kil;Kim, Yoo-Kuen;Lee, Hwa-Woon;Jang, Nan-Sim;Park, Moon-Ki
    • Journal of Environmental Science International
    • /
    • v.11 no.8
    • /
    • pp.801-810
    • /
    • 2002
  • The current paper describes the indoor/outdoor air quality in school environments through analyses of the heavy metal concentrations using Inductive Coupled Plasma(ICP). School environments in a heavy traffic area, two industrial areas, quasi-industrial area, and residential area were evaluated. The results were as follows: (1) The locations with the highest indoor and outdoor concentrations of heavy metals were the industrial areas followed by the heavy traffic area, residential area, and quasi-industrial area in a descending order of magnitude. Plus, the indoor heavy metal concentrations were higher then the outdoor ones. (2) The main heavy metal components were Zn, Al and Ca. Higher concentration levels were found indoors than outdoors. The heavy metal concentrations were also higher in the classrooms than in the corridor or outdoors. (3) The total heavy metal concentrations in the studied areas were highly dependent on the weather elements. including the relative humidity, mixing ratio, and wet-bulb depression. Accordingly, special ventilation systems are recommended to reduce air pollution in school environments.

Prediction and measurement of propagation path loss in indoor microcellular environments (실내 마이크로셀 환경에서 전파 경로손실의 예측과 측정)

  • 정백호;김채영;이숭복
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.11
    • /
    • pp.1-8
    • /
    • 1997
  • A prediction model is proposed to describe the path loss in propagation environment of indoor microcell. This model includes the lineal corridor for line--of-sight(LOS) and T-shaped corridor for non-line-of-sight(NLOS). In computation of receiving power the ray tracing technique based on image method is utilized and also reflected waves bounced on the walls and ceilings are considered. To check validity of the computed resuls cross checks between the predicted and measured are being made, which shows a close agreement for LOS case whereas somewhat disagreement for NLOS case. UTD technique is incorporated with propagation path determination algorithm in the treatment of NLOS case.

  • PDF

A Study on the Improvement of Indoor Thermal and Air Environment Made by Ceiling Cassette Type Cooling and Heating Unit in Classrooms (천장 카세트형 냉·난방기에 의해 형성되는 학교 교실의 실내 열환경 및 공기환경의 개선에 대한 연구)

  • Chang, Hyun-Jae;Lee, Ha-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.141-148
    • /
    • 2012
  • Ceiling cassette type air conditioner has been a main stream as a heating/cooling system recently in school, Korea. In this study, indoor thermal environments made by ceiling cassette type air conditioner were investigated by CFD simulation. Concentrations of $CO_2$ were investigated by a field measurement. Indoor thermal environment with the velocity inlet angle of $45^{\circ}$ from the ceiling in heating season was very ununiform so that thermal area was divided into two parts those the one is window side which is cold, and the other is corridor side which is hot. In cooling season under the same condition, there are areas too hot or too cold. If the velocity inlet angle is set in $30^{\circ}$ from the ceiling, indoor thermal environments was improved greatly in cooling season and heating season, too. Also, from the field measurement of $CO_2$ concentrations, it was suggested to install ventilators with proper air volume considered the number of class students.

The Prediction and Analysis of the Propagation Characteristics in Indoor Environments Using the SBR/Image Method (SBR 및 영상기법을 이용한 실내 환경의 전파특성 예측과 분석)

  • 손호경;김채영;김성진
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.2
    • /
    • pp.199-207
    • /
    • 2001
  • In this paper, the technique of prediction and analysis on the characteristics of propagation in indoor environment is presented. This technique needs no reception sphere commonly used in 3D-ray tracing scheme, and thereby it lends us easy code realization. The validity of developed code is verified by comparing with the values of image methods and measurement. The developed technique applied to the structure of rectangular corridor with the iron door and we calculated the path loss for the variation of the iron door angle. The path loss decreased about 15 dB at the distance of30 m from the iron door and the delay spread increased approximately by four times. Based on the computation, we confirmed that indoor propagation in PCS is heavily affected by the iron door in corridor.

  • PDF

A Study on the Evaluation for Elderly Housing Environment (노인주거환경 평가 틀에 관한 연구)

  • Shin, Hwa-Kyoung;Lee, Joon-Min
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.273-277
    • /
    • 2009
  • This study was conducted to develop standards for evaluating what extant the physical environments of housing which can cope with the needs of the aging society. This study was consisted through literature investigation research mainly, and research target literature limits keyword to elderly housing environment and chose connected domestic various literatures. The scope of evaluation was limited to the indoor spaces and outdoor spaces of housing as it was thought that the elderly spend much more time at indoor, outdoors, considering their physical characteristics. The study are as follows ; First, in outdoor only area from design environment element accessibility, and safety emphasized from equipment element, health of community territory was expose from design environment element that supportiveness is emphasized from equipment element. Second, in living room safety emphasized from design environment element in bedroom and bathroom of indoor individuation space, vestibule, balcony supportiveness, health was expose that is emphasized kitchen and mess. Also, was expose that supportiveness is emphasized from equipment element of all individuation spaces. Third, was expose that design environment element in corridor that is indoor official business space, stair, lobby, elevator and safety from equipment element and supportiveness are emphasized.

  • PDF