• Title/Summary/Keyword: Indoor Air quality

Search Result 1,019, Processing Time 0.024 seconds

Development of IAQ Index for Indoor Air Quality in City Buses (시내버스 실내공기질 IAQ 종합지수 개발)

  • Jeon, Bo-Il;Kwak, Min-Jeong;Kang, Sang-Hyeon;Kim, Jong-Cheol;Yun, Hyun-Jun;Kim, Ho-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.4
    • /
    • pp.444-456
    • /
    • 2020
  • Objectives: This study developed an index for the indoor air quality management of city buses to allow the provision of indoor air quality information to city bus users. Methods: Nine city buses in Seoul were measured for PM10, PM2.5, CO2, temperature, and relative humidity through IoT sensors. Big data collected through the sensors was analyzed to identify indoor air quality on city buses and graded through the index. Results: As a result of dividing the measured city bus data into five grades through the IAQ index, PM10 was rated "good" for 30.4% of the total measured values, and 9.2% were rated "risky". For PM2.5, 67.7 percent were rated "good" and 0.4 percent were rated "risky". For CO2, 0.9% were 'good' and 1.1% were 'risky'. The results of the classification through the IAQ index for city buses showed that the impact of good, normal, sensitive, bad, and dangerous were 2.7, 38.8, 46.0, 12.4, and 0.1%, respectively. According to the analysis by measurement area, Seocho-gu, Gangnam-gu, Seongdong-gu, Gwangjin-gu, and Dobong-gu are "normal" and other areas (Seodaemoon-gu, Jongno-gu, Yongsan-gu, Jung-gu, Seongbuk-gu, Dongdaemun-gu, Junggye-gu, Gangbuk-gu, and Nowon-gu) are all rated "sensitive". Conclusions: When analyzing cases where PM10 and CO2 indices are in the "bad" zone, the concentration is generally found to increase during rush hour, during which there are a large number of passengers. It is expected that indoor air quality management in vehicles will be necessary during rush hour.

Characteristics of pollutant emission from wallpapers - Around TVOC and HCHO - (벽지에서 발생되는 오염물질 방출특성 - TVOC와 HCHO를 중심으로 -)

  • Jang, Seong-Ki;Kim, Mi-Hyun;Lee, Hong-Suk;Lim, Jun-Ho;Jang, Mee;Seo, Soo-Yun
    • Analytical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.542-551
    • /
    • 2005
  • This study is to investigate the characteristics of emission concentration according to wallpaper sort and emission time using small chamber method. The target compounds included 45 VOCs and formaldehyde, which were respectively determined by adsorption sampling and thermal desorption coupled with GC/MS method, and by sampling in DNPH cartridge and HPLC method. The emission factor of TVOC and HCHO was detected to $1.1mg/m^2{\cdot}h$ and $0.01mg/m^2{\cdot}h$ respectively, and the wallpapers of 25 satisfied emission standard. TVOC emission factor appeared in order of the concentration of PVC, natural, and Non-PVC wallpaper, while HCHO was detected very low concentration without relation to wallpaper sort. The paraffin hydrocarbons appeared to be the most contributable class of hydrocarbons in terms of their concentrations, followed by aromatics, and olefins, halogenated hydrocarbons was not detected. PVC wallpapers plentifully emitted TVOC above other wallpapers, and toluene was showed higher concentration of 10 times than natural wallpaper. In addition to, emission factor according to elapse was gradually decreased.

The Assessment of Survey on the Indoor Air Quality at Schools in Korea (국내 일부학교 건축물의 실내공기질 평가)

  • Sohn Jong-Ryeul;Roh Young-Man;Son Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.2 s.89
    • /
    • pp.140-148
    • /
    • 2006
  • Recently, indoor air quality (IAQ) in workplace, residential environments and schools has been concerned of people, scientists and related the public, and has recognized the health effects related to indoor air pollution. Therefore, this study was performed to investigate the characteristics of IAQ in 55 kindergartens, elementary school, middle schools, and high schools from June, 2004 to May, 2005 in Korea. We measured indoor air pollutants($PM_{10},\;CO_2$, HCHO, total bacteria colony(TBC), CO, radon, TVOCs, asbestos, and $O_3$), and physical factors(noise, temperature, relative humidity, and illumination) with necessary of management for IAQ in school. We classified into 5 kinds of the school by period since building completion, <1 year, 1-3 years, 3-5 years, and 5-10 years. The concentration of pollutants and the level of physical factors compared with standards and guidelines of IAQ on the Ministry of Environment, the Ministry of Health and Welfare, and the Ministry of Education and Human Resources Development. The major results obtained from this study were as follows. Temperature, relative humidity and illumination among the physical factors did not exceed the standards, but noise exceeded it. Asbestos and $O_3$ did not detect in surveyed classrooms. CO, TBC, TVOCs, and HCHO in kindergartens, TBC in elementary schools, TBC, TVOCs dnd HCHO in middle schools, and HCHO in high schools detected the standards. This study is conducted as a part of efforts to provide a foundational data for further relative researches on management of IAQ of school. Therefore, we suggest that country plan for management of IAQ in school should be established through long-term and continuous investigation for assessment on IAQ in school and health risk assessment for students.

A Finish Material Management Process for Indoor Air Quality -Focused on Apartment Buildings- (실내 공기질을 고려한 마감자재 선정 프로세스 연구 -공동주택을 중심으로-)

  • Kwon, Gi-Deoc;Lee, Dong-Hoon;Lee, Sung-Ho;Zheng, Qi;Kim, Sun-Kuk
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.123-130
    • /
    • 2010
  • Indoor air quality has attracted great attention in recent years and thus the importance of managing finishing materials in terms of pollutant source control is being emphasized. Managing the finishing material at the design stage maximizes the efficiency of IAQ control at the following construction stage. However, there are insufficient investigations on the application of a specific finishing material management process, a database management system or a finishing material management process network. As a result, the main purposes of this study comprise comprehensive evaluation of IAQ performance from the selected finishing materials and auxiliary materials, application of the material management system basing on the types and characteristics of toxic substances generated from the indoor finishing materials, investigation of IAQ evaluation standard, and the overall IAQ evaluation method for the design parts. The result of this study will be the basic data to construct DBMS for management of finishing materials with respect to IAQ.

A Study on Indoor Air Pollutants Reduction Effect by Plants per Season (식물에 의한 계절별 실내공기오염물질 저감효과에 관한 연구)

  • Song, Jeong Eun;Kim, Yong Shik;Sohn, Jang Yeul
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.25-30
    • /
    • 2008
  • This study aims at examining the reduction of indoor air contaminants by plants placed in an indoor space. The effect of reducing the concentration of air contaminants by three species of plants was studied in a full-scale mock-up model. Field measurements were performed using Aglaonema brevispathum, Pachira aquatica and Ficus benjamiana which were verified as air-purifying plants by NASA. Their positions and amount were controlled. Two conditions for the amount of plants(10%, 5%) and positions(sun-shine, scatter) were used in two separate rooms whose dimensions are identical. The concentration of Volatile Organic Compounds(VOCs) was monitored three hours after the plants were placed and three days after the plants were placed. The variations of concentration of Benzene, Toluene, Etylbenzene, Xylene, Stylene and Formaldehyde, which are all known as the major elements of Volatile Organic Compounds were monitored. The more plants were used, the more a reduction of indoor air contaminants occurred. The effect of reducing the concentration of air contaminants increased when the amount of plants increased.

Desiccant Air Conditioning System market and Prospect (데시칸트 공조시장 및 전망)

  • Park, Seung-Tae;Chung, Kwang-Seop;Kim, Young-Il;Park, Jong-Il
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.230-235
    • /
    • 2009
  • The Desiccant air conditioning system has been designed as the industrial dehumidifier under the leadership of developed countries, considering CFC problems in 1990, indoor air quality(IAQ) and outdoor air intake rates. This could make the technical differences between them and us. Nowadays, domestic technology has been developed in some parts but there still remain many challenges to be managed. In this study, these tasks would be handled according to the desiccant air conditioning system market and prospects.

  • PDF

Characteristics of Heavy Metal Concentrations and Indoor Atmospheric Environments in Busan Metropolitan Area, Korea

  • Park, Jong-Kil;Kim, Yoo-Kuen;Lee, Hwa-Woon;Jang, Nan-Sim;Park, Moon-Ki
    • Journal of Environmental Science International
    • /
    • v.11 no.8
    • /
    • pp.801-810
    • /
    • 2002
  • The current paper describes the indoor/outdoor air quality in school environments through analyses of the heavy metal concentrations using Inductive Coupled Plasma(ICP). School environments in a heavy traffic area, two industrial areas, quasi-industrial area, and residential area were evaluated. The results were as follows: (1) The locations with the highest indoor and outdoor concentrations of heavy metals were the industrial areas followed by the heavy traffic area, residential area, and quasi-industrial area in a descending order of magnitude. Plus, the indoor heavy metal concentrations were higher then the outdoor ones. (2) The main heavy metal components were Zn, Al and Ca. Higher concentration levels were found indoors than outdoors. The heavy metal concentrations were also higher in the classrooms than in the corridor or outdoors. (3) The total heavy metal concentrations in the studied areas were highly dependent on the weather elements. including the relative humidity, mixing ratio, and wet-bulb depression. Accordingly, special ventilation systems are recommended to reduce air pollution in school environments.

An Analysis on HCHO, TVOC, CO2 Concentration of Existing-Housing Indoor-Air in Summer (기존 주택의 하절기 실내 공기중 HCHO, TVOC, CO2 농도 실태 조사분석)

  • Nam, Ki-Cheul;Lee, Young-Han
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.115-122
    • /
    • 2016
  • Purpose: The study is to measure indoor air pollutants concentration of existing housing and to analyze the causes and assess in accordance with the government's criteria. The research result could be used as data for public health through indoor air quality management of existing housing and more as a reference for new housing. Method: It was investigated 24 middle class housings of metropolitan area in summer which have been built for the past 30 years. Concentration of HCHO, TVOC was investigated in living room at morning and night and concentration of $CO_2$ was investigated in living room and master bedroom at morning and night. SKT100-X5 was used for concentration of HCHO, TVOC and ZGm053UK for concentration of $CO_2$. Result: Average concentration of TVOC was 1.31 times more than that of HCHO and standard deviation of that was 1.73 times higher. Average concentration of $CO_2$ was almost nearly close to 1,000ppm being criteria of the Ministry of Environment.

Study on Particulate Pollutant Reduction Characteristics of Vegetation Biofilters in Underground Subway Stations (지하역사내 식생바이오필터의 입자상 오염물질 저감특성 연구)

  • Kim, Tae Han;Oh, Ji Eun;Kim, Mi Ju
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.4
    • /
    • pp.99-105
    • /
    • 2022
  • Public attention to the indoor environment of underground subway stations, which is a representative multi-use facility, has been increasing along with the increase in indoor activities. In underground stations, fine iron oxide, which affects the health of users, is generated because of the friction between wheels and rails. Among particulate pollutant reduction technologies, plants have been considered as a non-chemical air purification method, and their effects in reducing certain chemical species have been identified in previous studies. The present study aimed to derive the total quantitative and qualitative reduction effects of a bio-filter system comprising air purifying plants, installed in an underground subway station. The experiment proceeded in two ways. First, PM(particulate matter) reduction effect by vegetation biofilter was monitored with the IAQ(indoor air quality) station. In addition, chemical speciation analysis conducted on the samples collected from the experimental and control areas where plants and irrigation using SEM-EDS(scanning electron microscopy-energy dispersive X-ray spectroscopy). This study confirmed the effect of the vegetation bio-filter system in reducing the accumulation of particulate pollutants and transition and other metals that are harmful to the human body.