학원교실의 냉방시 실내공기질 실태와 영향요인 분석 (Analysis on Influencing factors and Actual State of Indoor Air Quality by Cooling in Private Institute Classrooms)

  • 최윤정;이혜진;이지연
    • 한국생활과학회지
    • /
    • 제17권5호
    • /
    • pp.1001-1013
    • /
    • 2008
  • The purpose of this study were to make clear the actual state of indoor air quality by cooling in private institute classrooms and to analyze influencing factors on indoor air quality. The measurements of physical elements and observations of architectural characteristics and living conditions were carried out in each 1 classroom of 5 private institutes. Measuring elements were indoor temperature, relative humidity, $PM_{10}$, HCHO, CO, and $CO_2$ concentration. As results, the averages of indoor temperature each classroom were $21.7\sim28.1^{\circ}C$. 3 classrooms were lower than the Maintenance standard($26\sim28^{\circ}C$) of School Health Law. The means of relative humidity were 48$\sim$63%, all classrooms were ranged within the standard(30$\sim$80%). The means of $PM_{10}$ concentration were 2.1 $\sim$ 17 $\mu g/m^3$, all classrooms were kept within the standard(100 $\mu g/m^3$). The means of HCHO concentration were 0.02$\sim$0.16 ppm, 2 classrooms were exceed the standard(0.1 ppm). The means of CO concentration were 1.4$\sim$3.6 ppm, all classrooms were kept within the standard(10ppm). The means of $CO_2$ concentration were 1,593$\sim$3,819 ppm, all classrooms were exceed the standard(1,000ppm). The results of analysis on influencing factors of the physical elements are as follow; the air conditioner set of temperature, personal necessities like hair spray, teacher's smoking in corridor, windows and doors opening time, the number of students, and volume of classroom.

광촉매 건축자재와 환기시스템 적용에 따른 건축 환경 개선 방안 (Improvement of the Architectural Environment by Applying Photocatalyst Building Materials and Ventilation Systems)

  • 송용우;김성은;임세현;심성진
    • 토지주택연구
    • /
    • 제14권4호
    • /
    • pp.103-110
    • /
    • 2023
  • 하루 평균 대부분을 실내에서 보내는 현대인들은 내외부적으로 발생하는 실내오염물질에 지속적으로 노출되고 있다. WHO(World Health Organization) 2022년 보고서에 따르면 매년 세계적으로 약 700만명 이상의 사망 원인이 공기오염으로 실내오염물질의 심각성을 강조하고 있다. 대기오염물질 중에는 인체에 심각한 영향을 끼치는 질소산화물(NOx), 폼알데하이드(HCHO), 휘발성 유기화합물(VOCs) 등이 포함되는데, 이러한 실내공기 오염물질을 제거할 수 있는 물질로 광촉매가 있다. 광촉매는 미세먼지 전구물질 제거 성능뿐만 아니라 향균, 살균, 탈취 성능 또한 가지고 있어, 실내공기질 개선에 효과적이다. 이에, 본 연구에서는 광촉매를 건축물에 적용할 수 있는 부위 및 방안을 제시하였다. 적용 가능한 부위로는 내외장재, 콘크리트 등을 포함한 건축자재, 유기도료, 환기장치 등이 있으며, 각 부위에 최적 적용 방안에 대한 연구를 진행하였다.

다중이용시설의 실내공기 미생물 오염실태에 관한 연구 (The Study On the Distribution of Indoor Concentration of Microorganism in Commercial Building)

  • 박경수;최상곤;홍진관
    • 설비공학논문집
    • /
    • 제18권8호
    • /
    • pp.620-626
    • /
    • 2006
  • Recently, indoor air quality (IAQ) is one of the greatest problems in our modern societies. Although research for IAQ is made rapid progress but IAQ problems concerning in door microorganism contamination is required to be studied still more. So we have investigated the indoor microorganism concentration of a variety of department store, subway station, underground shopping center, kindergartens, library where people complain about the in-door air quality. The experiment on microorganism concentration of indoor air was carried out and the average of total microorganisms was measured. Comparing the experimental results with existing foreign criterion, the experimental results show that the ministry of environment recommendation microorganism concentration value ($800 CFU/m^3$) is in need of revision in the near future.

공동주택에 적용된 Shaft Box형 발코니의 환경성능 검토 (An Investigation of Environmental Performance on Shaft Box Type Balcony Adopted to Apartment Building)

  • 노지웅
    • KIEAE Journal
    • /
    • 제13권4호
    • /
    • pp.27-32
    • /
    • 2013
  • This study focus on shaft box facade, special form of box window construction. It consists of a system of box window with continuous vertical shafts that extend over a number of stories to create a stack effect. The subject building was decided by analyzing various types of exiting apartments. Shaft box type balcony was devised by setting up shaft space at a part of balcony. Air flow and indoor air temperature were simulated, performance of shaft box type balcony was compared with existing types using VE computer simulation program. Research consequence can be summarized as follow: 1) In the case of existing types, the change of window opening rate has only a little effect on the improvement of indoor temperature. But, air flow rate increased two times in the case that changed opening rate 20% to 40% 2) In the case of existing types, the growth of air flow rate has little effect on the improvement of indoor temperature. But, shaft box type represented the remarkable effect on the improvement of indoor temperature as well as the growth of air flow rate.

냉매 R410A를 적용한 실내 열교환기 설계 (Design of an Indoor Heat Exchanger that Apply Refrigerant R410A)

  • 김범찬;박창석;차우호;김성수;강용태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.317-322
    • /
    • 2008
  • The objectives of this paper are to study the effects of thermal and geometric conditions on the performance of indoor heat exchanger with R410A for Gas Engine Driven Heat Pump (GHP) application and to find optimum design conditions of indoor heat exchanger by parametric analysis for the key parameters. In the air side, moisture out of the humid air condenses on the fin surface while the refrigerant (R410A) boils inside the smooth tube. Therefore this study uses Log Mean Enthalpy Difference (LMHD) method to analyze the heat transfer from the humid air to the refrigerant of R410A. The results show that fin pitch and longitudinal pitch have significant effect on the heat exchanger preformance. This study will provide the guideline for optimum design of indoor heat exchanger with R410A for GHP application.

  • PDF

A Simple and Simultaneous Analysis of Volatile Halogenated Hydrocarbons in Indoor Air Using Personal Sampler

  • Jung, Won-Tae;Sohn, Dong-Hun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제9권E호
    • /
    • pp.373-381
    • /
    • 1993
  • To understand the human exposure levels of volatile halogenated hydrocar-bons in ambient air, a new rapid and convenient analytical method for determination of the compounds in gaseous phase was evaluated and established. The method is based upon passsive diffusion to personal sampler containing adsorbent and solvent extraction followed by purge trap/ on-column cryof-ocusing method. A new method needs no special instrumentation for gas collection because it is based upon the passive diffusion principle. The typical chromatogram obtained in this study proved that rapid and simultaneous determination of target analytes was possible with good resolution. The developed method was successfully applied to determine the volatile halogenated hydrocarbons in indoor air and the values obtained by this new method were compared with those by direct suction method. The concentration of carbon tetrachloride, 1,1,2-trichloroethylene, chloroform showed the values below 400$\mug/m^3$ except the maximum of 1,513$\mug/m^3$ of chloroform. 1,1,1-Trichloroethane showed approximately 1,000 to 5,000$\mug/m^3$ range of diurnal fluctuation in indoor air.

  • PDF

건축자재의 산화티타늄 코팅을 통한 휘발성 유기화합물 분해 (Destruction of Volatile Organic Compounds Using Photocatalyst-Coated Construction Materials)

  • 조완근;전희동
    • 한국환경과학회지
    • /
    • 제14권8호
    • /
    • pp.785-792
    • /
    • 2005
  • In order to reduce roadside and indoor air pollution for volatile organic compounds VOC), it may be necessary to apply photocatalyst-coated construction materials. This study evaluated the technical feasibility of the application of $TiO_2$ photocatalysis for the removal of VOC present in roadside or indoor air. The photocatalytic removal of five target VOC was investigated: benzene, toluene, ethyl benzene and o,m,p-xylenes. Variables tested for the current study included ultraviolet(UV) light intensity coating materials, relative humidity (RH), and input concentrations. Prior to performing the parameter tests, adsorption of VOC onto the current experiment was surveyed, and no adsorption was observed. Stronger UV intensity provided higher photocatalytic destruction(PCD) efficiency of the target compounds. For higher humidity, higher PCD efficiency was observed. The PCD efficiency depended on coating material. Contrary to certain previous findings, lower PCD efficiencies were observed for the experimental condition of higher input concentrations. The current findings suggested that the four parameters tested in the present study should be considered for the application of photocatalyst-coated construction materials in cleaning VOC of roadside or indoor air.

겨울철 난방시 탑상형 아파트 구조체의 축·방열 특성에 대한 현장측정 연구 (A Field Measurement Study on Heat Storage/Emission Characteristics of Tower Type Apartment Structures in Winter Season)

  • 장현재;조근제
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.190-195
    • /
    • 2012
  • In this study, as a complementary study of the former study on indoor thermal environment in a tower type apartment house at tropical nights, a field measurement was conducted in winter season. Mainly, characteristics of heat storage and heat emission in apartment structures, in this study, were investigated. As results, indoor air temperature was changed in the range of $22.5^{\circ}C{\pm}1.0^{\circ}C$, and followed not the change of outdoor air temperature but the changed pattern of floor surface temperature. Wall surface temperature was unresponsive to the change of floor surface temperature compared with the change of indoor air temperature because wall structure was composed of concrete which has large heat capacity, and was changed in the range of $22.3^{\circ}C{\pm}0.6^{\circ}C$. Heat was stored continuously into the structures of wall and ceiling through the measurement term. and this means that a large heat capacity of the apartment structure acts as a disadvantage in winter season, too. As a total review of the study with the former study, a large heat capacity of the apartment structure acts against indoor thermal comfort in winter season as well as in summer season.

벽면형 식물바이오필터 내 식물 생육 및 실내공기질 정화 (Plant Growth Responses and Indoor Air Quality Purification in a Wall-typed Botanical Biofiltration System)

  • 정슬기;천만영;이창희
    • 한국자원식물학회지
    • /
    • 제28권5호
    • /
    • pp.665-674
    • /
    • 2015
  • 본 연구의 최종 목표는 실내의 공간과 식물바이오필터의 규모에 따라 실내공기 오염물질을 정화할 수 있는 식물 녹화와 자동관수 그리고 생물학적 여과 기능을 통합한 식물바이오필터 시스템의 개발이다. 본 실험에 사용된 식물 바이오 필터는 실내공간을 효율적으로 사용하기 위해 물펌프, 물탱크, 송풍기, 가습장치, 그리고 다층 구조의 식물 식재 공간을 일체형으로 설계하였다. 본 연구는 인공적인 실내 공기 오염원을 발생시키지 않은 상태에서 바이오필터 부근의 공간과 바이오필터와 멀리 떨어진 공간(무처리구)의 실내 공기질을 비교하고, 바이오필터 내다층 구조의 식재층에 따른 식물의 생육을 평가하고자 수행하였다. 바이오필터 처리 공간 내 휘발성 유기 화합물(TVOCs), 일산화탄소, 이산화탄소와 같은 실내 공기 오염물질의 농도는 무처리구에 비해 낮게 나타났다. 또한 바이오필터 내 식재된 층에 관계없이 Dracaena sanderiana ‘Vitoria’와 Epipremnum aureum ‘N Joy’는 정상적으로 생육하였다. 따라서 실내식물을 식재할 수 있는 본 벽면형 식물바이오필터는 실내 공기 정화에도 효과가 있는 것으로 확인하였다.

실내공기중의 휘발성유기화합물 농도변화에 관한 연구 (A Study on Concentration of Volatile Organic Compounds in the Apartment House)

  • 이윤규
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.129-136
    • /
    • 2004
  • Recently, indoor air pollution has been seriously apprehended, and became a striking issue, due to the airtightness of buildings or the misuse of building materials. Especially, SHS(Sick House Syndrome) and MCS(Multi Chemical Sensitivity) which can have bad influences on the resident in an existing apartment house as well as newly constructed apartment house start to attract public attention. The emission rates of VOCs is sensitively affected by the indoor/outdoor condition, construction materials, construction method, and character of ventilation facilities. Therefore, in this study, by measuring the indoor air pollution substance of the existing apartment house, the problem over this tends to be grasped and it is going to secure an improvement methods.