• Title/Summary/Keyword: Individual tray technique

Search Result 17, Processing Time 0.026 seconds

A STUDY ON ACCURACY AND DIMENSIONAL STABILITY ACCORDING TO IMPRESS10N METHODS (인상채득방법과 방향에 따른 인상체의 정밀성과 체적 안정성에 관한 연구)

  • Lee, Jae-Young;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.567-580
    • /
    • 1999
  • Accurate reproduction of intraoral tissue is essential in the fabrication of fixed prosthesis. This selection of impression material and method is very important. In this study, vinyl polysiloxane type impression material $Panasil^{(R)}$ was used. Three impression methods ; one-step technique, individual tray technique, and individual tooth tray technique using the vinyl polysiloxane type bite registration material $Futar^{(R)}$ Occlusion, were used to take horizontal and vertical impression. Improved stone models were fabricated. The amount of occlusal surface discrepaneies, interabutment distance discrepancies, amount of marginal defect were evaluated with the $X-PLAN360d^{(R)}$ and photoscanning. The results were as follows. 1. There was no significant difference in occlusal surface according to the directions and techniques of impression taking. 2. There was no significant difference in interabutment distance discrepancies according to the directions and techniques of impression taking 3. There was no significant difference in marginal discrepancies according to the direction of impression taking but there was significant difference between one-step technique and individual tray technique, individual tooth tray technique (P<0.05). Taken together, these results suggest that individual tray technique and individual tooth tray technique are more accurate for impression taking than one-step technique.

  • PDF

A comparative study on the accuracy of impression body according to the types of impression tray (임플란트 인상 채득 시 트레이 종류에 따른 인상체의 정확도에 관한 비교 연구)

  • Yi, Hyun-Jung;Lim, Jong-Hwa;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.48-54
    • /
    • 2010
  • Purpose: The objective of this study was to evaluate and compare the accuracy of impression body taking by the closed and the open tray impression technique with 3 types of impression tray. Individual tray, metal stock tray and polycarbonate tray were used. Materials and methods: Nine closed tray impressions were taken by individual tray, metal stock tray and polycarbonate stock tray, respectively with polyether impression material. 9 open tray impressions were also acquired by same manner. Precision analysis on the master models was performed by attaching the reference frameworks with alternate single screws and measuring the vertical fit discrepancy of respective analogues in working cast with a stereo microscope. Data were analyzed by 1 way ANOVA and independent t-test. Results: The average fit accuracy of impression bodies was calculated. With the closed tray impression technique, there were significant statistical differences in vertical fit discrepancy according to the types of tray. The individual tray group showed the lowest value and the polycarbonate stock tray group represented the highest. With the open tray impression technique, there was no significant difference in vertical fit discrepancy. Significant statistical difference in vertical fit discrepancy was found between the open and the closed impression technique with the polycarbonate stock tray. Conclusion: From the results above, more precise impressions could be acquired by the rigid individual tray compared with the polycarbonate stock tray. It was hard to get consistent accuracy impressions by the closed tray impression technique with polycarbonate stock trays.

Maxillary complete denture rehabilitation in flabby tissue patient fabricated by no-pressure impression technique with individual tray replicated treatment denture through 3D printing: A case report (3D 프린팅으로 치료 의치를 복제한 개인 트레이를 이용한 무압 인상을 통해 제작한 flabby tissue 환자의 상악 총의치 수복 증례)

  • Hong, Jun-Pyo;Bae, Jung-Yoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.3
    • /
    • pp.246-253
    • /
    • 2022
  • Flabby tissue is not rare for denture wearers. Mucostatic impression technique is necessary due to compromised retention and stability of denture resulting from distortion of mobile flabby tissue. In this report, individual tray was fabricated by model-scanning and 3D printing treatment denture. And then, mucostatic impression for flabby tissue was obtained by using individual tray modified with window technique. Definitive denture was fabricated based on information of treatment denture including incisal pontic arrangement, jaw relationship and occlusion.

An alternative impression technique based on McLean's functional impression concept (McLean의 기능 인상법에 기반한 새로운 인상채득법)

  • Choi, Hyun-Suk;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.32-37
    • /
    • 2017
  • In this case report, an alternative impression technique for fabricating removable partial dentures was used in a patient with very few remaining teeth. In this technique, an individual tray was made on the cast, which was made by relining interim denture and taking overimpression with irreversible hydrocolloid according to McLean's functional impression concept. This method showed the following advantages: the no need for border molding with modeling compound, time saving for denture impression without overextension and accurate seating of the individual tray.

A STUDY ON THE ACCURACY OF THE IMPRESSION BODY ACCORDING TO MATERIALS AND FORMS OF THE INDIVIDUAL TOOTH TRAY (개별 치아 트레이의 재료와 형태에 따른 인상체의 정밀성에 관한 연구)

  • Ryu, Duck-Woo;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.242-254
    • /
    • 2000
  • Accurate impression is very important to achieve desirable prosthesis and there are many factors in taking a good impression. For example, types of impression material, types of impression tray, impression taking methods and so on. Recently individual tooth tray technique is accepted as obtaining good impression that can be applied to multiple abutment impression, heavy salivated patient, to minimize the effect of natural teeth s undercuts and to reduce pain during cord packing procedures. The purpose of this study was to compare the accuracy according to materials and forms of the individual tooth tray which is clinically applied nowadays. Used materials in experiment were divided into 3 types (acrylic resin. $Futar^{(R)}$ occlusion. $Blu-mousse^{(R)}$) and forms were divided into 2 types (forming occlusal vent hole or not and forming marginal vent space or not). Stone master model from impression body and metal master model were measured by $X-PLAN360d^{(R)}$ to compare occlusal surface discrepancy and marginal discrepancy. The results were as follows: 1. In comparison of occlusal surface discrepancy and marginal discrepancy according to materials, groups with three materials showed no statistical difference 2. In comparison of occlusal surface discrepancy and marginal discrepancy according to occlusal vent hole, groups with occlusal vent hole showed significantly less marginal discrepancy than groups with no occlusal vent hole(p<0.05). 3. In comparison of occlusal surface discrepancy and marginal discrepancy according to 0.5mm-marginal-vent-space, groups with no 0.5mm-marginal-vent-space showed significantly less marginal discrepancy than groups with 0.5mm-marginal-vent-space (p<0.05). In summary these results suggest that individual tooth tray made of 3 types of materials with occlusal vent hole and individual tooth tray made of acrylic resin with no marginal vent space showed good accuracy of impression. In addition, individual tooth tray which is made of bite registration materials may be more useful because of advantage in facility and timesaving aspect of fabrication.

  • PDF

Implant overdenture impressions using a dynamic impression concept

  • Lee, Byung-Kil;Park, Sang-Hun;Lee, Cheong-Hee;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.66-70
    • /
    • 2014
  • A dynamic impression is a functional impression that records the functional movement of the patient's own muscle and muscle attachment. This process reduces the number of random factors. This article describes a method for making a special tray using a dynamic impression concept that was made from provisional dentures used for implant healing. The individual tray is used to make a wash-impression to record the features of the mucosa in detail. The main advantage of this technique is that it provides a functional relationship of the implant components to the supporting tissues without overextension because provisional denture had been used for 2 months and the border length of individual tray was nearly the same as that of provisional denture. The delivery of the prosthesis constructed using this impression technique is time-saving because there is no need for border molding and there are fewer post-insertion appliance adjustments.

ACCURACY OF THE IMPRESSION TECHNIQUE USING THERMOFORMING POLYMETHYL METHACRYLATE TRAY

  • Miyashita, Yuko;Suzuki, Hiroki;Kishi, Masataka;Ko, Sok-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.389-400
    • /
    • 2007
  • Statement of problem. Use of the conventional dental impression procedure is problematic in patients who have difficulty opening their mouth, difficulty breathing through their nose or tendency to gag. Purpose. It is necessary to make individual trays more comfortable for patients during impression taking procedure. It was reported at the KAP Annual Meeting 2001 Seoul that an improved impression technique was suitable for this purpose. In this study, the accuracy of the improved dental impression method for implant was compared with the conventional dental impression method. Material and methods. An oral simulator was made from clear acrylic resin block which had similar form of edentulous ridge. For setting up the standard, five fixtures were installed on it. Study casts were made using two kinds of impression techniques. One was the conventional method that was taken using silicone impression material and an individual resin tray under connection of inter-fixture relation. The other was the improved method in which was the connection of the impression coping and the thermoformed polymethyl methacrylate tray. In addition, two different study casts were made from the improved impression body. The coordinates of the fixture on the study model were measured by three-dimensional coordinate measuring equipment. Then the distances between each fixture were calculated and compared with that of oral simulator. Accuracy of the each impression method was also assessed. Results. The differences of inter-fixture dimension between study casts and simulator in the improved impression technique showed $0.014{\pm}0.016mm$ and $0.017{\pm}0.022mm$, respectively and that of the conventional method was $0.017{\pm}0.014mm$. There was no significant difference between the improved impression technique and conventional method. Conclusion. The improved impression technique is useful for multiple support implants.

Fabrication of denture by using the individual tray duplicated an existing denture through 3D printing: A case report (3D 프린팅을 통해 기존의치를 복제하여 개인트레이로 활용한 총의치 제작 증례)

  • Park, Juyoung;Park, Sangwon;Lim, Hyun-Pil;Park, Chan;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.508-514
    • /
    • 2021
  • In this report, Replicated denture was fabricated by 3d printing after scanning the existing denture. It was used as an individual tray in closed-mouth technique. It reduced laboratory process and clinical time. Also it helped in facial evaluation and tooth arrangement. Compared to open-mouth technique, the number of visits was reduced, and the patient's adaptability to new denture was enhanced by utilized various information of the existing denture, including vertical dimension.

Fabrication of complete denture using Centric tray and closed mouth technique for edentulous patient (과도한 치조제 흡수를 보이는 무치악 환자에서 Centric tray와 폐구법 인상을 이용한 총의치 수복 증례)

  • Jung, Sua;Ma, Boyoung;Yang, Hongso;Park, Sangwon;Lim, Hyun-Pil;Yun, Kwidug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.120-125
    • /
    • 2018
  • Conventional denture impression techniques have limitations for edentulous patients with severe alveolar bone resorption and can cause problems from excessive border extension. Especially when a patient has movable tissue it is difficult to make accurate impression, thus might interrupt stable seating of complete denture. Fabrication of complete denture using closed mouth technique for edentulous patient with severe ridge resorption is thought to provide better stability and retention. In this case, an 86-year-old patient had both edentulous jaws with epulis fissuratum on maxillary anterior ridge and severe mandibular ridge resorption. Thus, tentative vertical dimension was determined by using Centric trayand individual tray attached with gothic arch tracer was fabricated. Complete denture was fabricated using closed mouth technique and the patient was satisfied with better stability and retention of the complete denture.

Fabrication of mandibular suction denture for complete edentulous patient: A case report (하악 흡착식 의치를 이용한 완전 무치악 환자의 총의치 수복 증례)

  • Park, Minhyuk;Park, Sang-Won;Lim, Hyun-Pil;Park, Chan;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.257-267
    • /
    • 2020
  • The goal of suction denture is to enhance retention of dentures by the formation of negative pressure between the denture base and the underlying tissue and sealing around the denture by the mucosa. This patient has been converted to a completely edentulous state after the extraction of residual teeth. Fabrication of suction denture was planned because it was estimated that the conventional compete would be hard to achieve retention due to the absorption of residual ridge and lack of sublingual fold. Through appropriate clinical and laboratory technique such as preliminary impression on the mandibular rest position, provisional vertical dimension determination with Centric Tray® (Ivoclar Vivadent AG, Schaan, Liechtenstein), closed mouth definitive impression and jaw relation record using individual tray with Gnathometer M® (Ivoclar Vivadent AG, Schaan, Liechtenstein), artificial teeth arrangement considering stability of the denture, and proper polymerization technique that minimizes polymerization shrinkage, restoring the patient with suction denture resulted in satisfaction throughout the function and asesthetics.