A Fault-Tolerant Strategy for Indirect Matrix Converter

  • Tran, Quoc-Hoan;Lee, Hong-Hee;Chun, Tae-Won
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.283-284
    • /
    • 2013
  • This paper proposes a fault-tolerant strategy for indirect matrix converter (IMC) based on the concept of four-leg matrix converter in case of an open-circuit fault in the inverter stage. The proposed strategy can maintain the same output performance as the healthy condition during the faulty condition. Some simulated results are provided to verify the effectiveness of the proposed strategy.

  • PDF

80C196MC를 이용한 유도전동기 벡터제어 (Vector Control of Induction Motors using 80C196MC)

  • 이동명;김창현;이주환;김학원;홍석종;김종철;신휘범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.156-160
    • /
    • 1997
  • This paper proposed the vector controller of induction motors using one chip microprocessor. For developing a small and cheep speed control system, we use the one chip microprocessor 80C196MC. By using the one chip microprocessor we can make an inexpensive and small-sized vector controller for induction motors. We apply indirect vector control method and space vector modulation method to this system. The experimental results show that the proposed inverter has high performance features.

  • PDF

동물플랑크톤 노출 강도가 유해남조 Microcystis aeruginosa와 Planktothrix agardhii의 생체량 및 세포내 microcystin함량변화에 미치는 영향 (Effect of Zooplankton Exposures on the Biomass and Intracellular Microcystin in Microcystis aeruginosa and Planktothrix agadhii)

  • 장민호;정종문;주기재
    • 생태와환경
    • /
    • 제39권2호통권116호
    • /
    • pp.209-218
    • /
    • 2006
  • 두 종의 초식성 동물플랑크톤(Daphnia magna. Moina macrocopa)의 직접노출 밀도차(0, 4, 8개체)와 동물플랑크톤 배양여과액(ZCMF) 농도차(0, 25, 50%)에 따른, 두남조 Microcystis aeruginosa와 Planktothrix agardhii의 생체량과 세포내 microcystin(MC)을 1일 간격으로 측정하였고, 직접노출실험의 경우 동물플랑크톤 생존륜을 1일 간격으로 관찰하였다. 동물플랑크톤 직접노출 실험 결과, 두 균주에서 세포내 MC함량이 증가하였으며 (rm-ANOVA: P< 0.039), P. agardhii균주에서는 4개체 처리군(ZT1)보다 8개체 처리군(ZT2)에서 통계적으로 유의한 수준으로 높은 세포내 MC값이 관찰되었다(Tukey test. P<0.082).세포내 MC가 최고값을 보인 3일 또는 4일째에, 처리군들은 대조군에 비하여 통계적으로 유의한 차이를 보였다(One-way ANOVA, P< 0.021). ZCMF에 노출시킨 M. aeruginosa균주에서 세포내 MC함량이 통계적으로 유의한 수준으로 차이가 있었다(rm-ANOVA: P< 0.004), 실험기간동안 세포내 MC값은 M. aeruginosa균주에서 25%처리군 보다 50%처리군에서 통계적으로 유의한 수준으로 높게 나타났다(Tukey test, Plt; 0.025). 본연구결과, 세포내 MC량은 초식성 동물플랑크톤의 직접노출 밀도차와 분비화학물질(infochemical)농도차에 의존하여 증가 혹은 변화될수 있는 가능성이 있는 것으로 나타났으며, 부영양호에서 독성 남조 번성 조절시, 이러한 가능성을 고려하여 생물조절이 이루어져야 할 것으로 보인다.

An Analytical Approach for Design of Nth-band FIR Digital Filters with Equi-Ripple Passband

  • Moon, Dong-Wook;Kim, Lark-Kyo;Lim, Cheng-Chew
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권3호
    • /
    • pp.423-428
    • /
    • 2009
  • In FIR (Finite Impulse Response) filter applications, Nth-band FIR digital filters are known to be important due to their reduced computational requirements. The conventional methods for designing FIR filters use iterative approaches such as the well-known Parks-McClellan algorithm. The Parks-McClellan algorithm is also used to design Nth-band FIR digital filters after Mintzer's research. However, a disadvantage of the Parks-McClellan algorithm is that it needs a large amount of design time. This paper describes a direct design method for Nth-band FIR Filters using Chebyshev polynomials, which provides a reduced design time over indirect methods such as the Parks-McClellan algorithm. The response of the resulting filter is equi-ripple in passband. Our proposed method produces a passband response that is equi-ripple to within a minuscule error, comparable to that of Mintzer's design method which uses the Parks-McClellan algorithm.

영구자석 매입형 브러시리스 직류 전동기용 센서리스 드라이브 개발에 관한 연구 (Development of a Sensorless Drive for Interior Permanent Magnet Brushless DC Motors)

  • 여형기;홍창석;이광운;박정배;유지윤
    • 전력전자학회논문지
    • /
    • 제2권3호
    • /
    • pp.44-50
    • /
    • 1997
  • 본 논문은 영구자석 매입형 브러시리스 직류 전동기를 회전자 위치 센서 없이 구동하는 센서리스 드라이브의 개발에 관한 연구이다. 영구자석 매입형 전동기는 회전자의 위치에 따라 각 상의 인덕턴스가 크게 변화한다. 회전자의 위치를 간접적으로 검출하기 위해 인덕턴스 변화에 따른 단자전압 파형의 특성을 분석하고 이에 적합한 회전자 위치 간접검출 방법을 제시하였다. 또한 87c196mc 원 칩 마이크로프로세서를 이용하여 실용적이고 경제성 있는 센서리스 드라이브를 제작하여 에어콘 콤프레서의 구동에 적용하였다. 제시된 실험 결과는 본 연구에서 제안한 간접검출 방법의 타당성과 개발된 드라이브의 유용성을 보여준다.

  • PDF

A New Study on Indirect Vector AC Current Control Method Using a Matrix Converter Fed Induction Motor

  • Lee Hong-Hee;Nguyen Hoang M.
    • Journal of Power Electronics
    • /
    • 제6권1호
    • /
    • pp.67-72
    • /
    • 2006
  • This paper introduces two different types of AC current control methods for an indirect vector controlled induction motor using a matrix converter. The proposed methods combine the advantages of matrix converters with the advantages of the indirect vector AC current control methods. The first proposed method explains the basic idea of the hysteresis current control method for matrix converters and shows its capability and stability in comparison to the conventional method usually used for VSI. With the aid of the special configuration of the matrix converter, we also propose another current method which is modified from the first one in order to reduce both current ripple and torque ripple. Simulation results have verified the feasibility and the effectiveness of the proposed methods.

삭시톡신 분석을 위한 항체의 제조 및 항-삭시톡신 항혈청의 민감도 분석 (Production of antibodies for saxitoxin analysis and sensitivity analysis of anti-saxitoxin antiserum)

  • 장만;이건섭;모상현;신경순;오정균;이택견
    • 한국산학기술학회논문지
    • /
    • 제13권12호
    • /
    • pp.6208-6214
    • /
    • 2012
  • 해양미세조류 유래 독성물질에 대한 이해와 활용에 있어서 가장 중요하지만 간과되고 있는 부분은 독성물질을 검출할 수 있는 빠르고, 쉽고 경제적인 검출기술을 개발하는 것이다. 이 논문에서 우리는 삭시톡신(STX)에 대한 항체를 생산하였다. 헤모시아닌(mariculture keyhole limpet hemocyanin, mcKLH)과 오브알부민(ovalbumin, OVA)을 운반단백질로 사용하였다. 면역반응을 위해서 mcKLH-STX 결합체를 BALB/c 쥐에 복강주사하였다. 채혈 후 항-STX 항혈청을 분리하였다. 항혈청의 역가분석을 위하여 유리 STX와 OVA-STX로 코팅된 microtiter plate를 이용하여 간접 ELISA 실시하였다. 발색반응을 위한 이차항체로는 goat anti-mouse IgG-phosphatase conjugate가 사용되었다. 항-STX 항혈청은 OVA-STX와 유리 STX에 특이적으로 반응하였다. 항-STX 항혈청의 민감도는 매우 높았으며, STX를 위한 검출한계는 약 64.9 ng/kg이었다.

균일 리플 통과대역 응답을 갖는 1/3 밴드 FIR 필터의 설계 (A Design Method for Third-Band FIR Filters of Equi-Ripple Passband)

  • 문동욱;김낙교
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권9호
    • /
    • pp.570-576
    • /
    • 2005
  • In FIR (Finite Impulse Response) filter applications, Nth-band FIR digital filters are known to be important due to their reduced computational requirements. The conventional methods for designing FIR filters use iterative approaches such as the well-known Parks-Mcclellan algorithm. the Parks-Mcclellan algorithm is also used to design Nth-band FIR digital filters. But a disadvantage of the Parks-McClellan algorithm Is that it needs a good amount of design time. This paper describes a direct design method for third-band FIR Filters using Chebyshev polynomial, which provide a reduction in design time over indirect methods such as the Parks-McClellan algorithm. The response of the resulting filter is equi-ripple in passband. The proposed method of design produces a passband response that is equi-ripple to within a minuscule error, compare to that of the Parks-McClellan algorithm.

소아 대퇴탈장의 중요성 (The Importance of Femoral Hernia in Children)

  • 한석주;최봉수;한애리;오정탁;최승훈;황의호
    • Advances in pediatric surgery
    • /
    • 제6권2호
    • /
    • pp.124-127
    • /
    • 2000
  • Femoral hernia is very rare in children and is easily misdiagnosed. During a period of three years, three children with femoral hernia were treated by one pediatric surgeon at Severance Hospital. Only one case was diagnosed correctly before surgery, and the others were thought to be either an indirect inguinal hernia or groin mass. Curative hernioplasty (McVay hernioplasty) could be done in only one case at the time of first operation. Diagnosis of femoral hernia in children is a challenge because of rarity and similarity of clinical presentation to indirect inguinal hernia. Co-incidental findings of indirect inguinal hernia sac or patent processus vaginalis during surgery can perpetuate the misdiagnosis. In case of absence of expected indirect inguinal hernia or apparent recurrence of indirect inguinal hernia, one should consider the possibility of femoral hernia.

  • PDF

잡식성 및 플랑크톤 섭식어류의 간접노출 강도가 Microcystis aeruginosa의 microcystin 함량변화에 미치는 영향 (Changes in Microcystin Production in Microcystis aeruginosa Exposed to Different Concentrations of Filtered Water from Phytoplanktivorous and Omnivorous Fish)

  • 장민호;정종문;윤주덕;이유정;하경
    • 생태와환경
    • /
    • 제40권2호
    • /
    • pp.294-302
    • /
    • 2007
  • 잡식성 및 플랑크톤 섭식 어류(Carassius gibelio langsdorfi, Hypophthalmichthys molitrix)의 간접노출(CCMF, HCMF) 농도차(0, 10, 50%)에 따른, 남조 Microcystis aeruginosa의 생체량과 세포내부와 외부의 마이크로시스틴(microcystin, MC) 함량을 1일 간격으로 관찰하였다. 실험기간동안 M. aeruginosa균주의 세포내에 함유된 MC의 양은 대조군 보다 모든 처리군에서 증가한 것으로 나타났다(CCMF1, P=0.015; CCMF2, P<0.001; HCMF1, P< 0.001; HCMF2, P<0.001). 처리군간의 비교에서는 CCMF1의 세포내 MC함량 보다 CCMF2의 세포내 MC 함량이 통계적으로 유의한 수준으로 증가하였다(P=0.023). 또한 HCMF2의 세포내 MC함량이 HCMF1의 MC함유량보다 증가한 것으로 나타났다(P<0.001). M. aeruginosa균주의 세포외 MC함량은 대조군과 CCMF1과 CCMF2에서 차이를 보이지 않았고, HCMF1과 HCMF2의 세포외 MC함량이 대조군보다 높은 것으로 나타났다(HCMF1, P=0.003; HCMF2, P<0.001). 본 연구결과, 독성 Microcystis의 경우 어류의 분비화학물질(kairomone) 농도에 따라 세포 내, 외부의 독성이 증가될 가능성이 있으며, 부영양호에서 생물적 조절을 통한 조류저감을 실시할 경우 Microcystis의 독소 변화를 고려해야 할 것으로 보인다.