• Title/Summary/Keyword: Indicated efficiency

Search Result 1,319, Processing Time 0.03 seconds

Exergy Analysis of Solar Collector

  • 이석건;이현우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.32 no.E
    • /
    • pp.74-79
    • /
    • 1990
  • Important factors in evaluating solar collcetor efficiency are solar radiation, temperature and flow rate of the working fluid. The effects of these factors on the energy and the exergy gained by water, the working fluid, from the collector were analyzed. The results indicated that the collector efficiency and the energy and the exergy gained by the water from the collcetor increased with the increase of solar radiation. According to the exergy analysis, as the water temperature at the inlet of the collector increased, the exergy gained by the water increased while the energy gained by the water decreased. The water temperature at the outlet of the collector could be calculated with a mean error of 2.8%, and the energy and the exergy could be calculated theoretically with mean errors of 16.8% and 19.1%, respcetively.

  • PDF

The Activity and Utilization of Urease Inhibitors (요소분해효소 억제물질의 작용과 응용에 관한 연구)

  • 주영규
    • Asian Journal of Turfgrass Science
    • /
    • v.6 no.1
    • /
    • pp.23-28
    • /
    • 1992
  • Urea, the major N source of world agriculture involves a serious urea-N loss through NH$_3$volatilization. Approaches to decrease N loss include using urease inhibitors in view of the environmental protection and the increase of urea-N efficiency. The purpose of laboratory researches was toassess the potential value of urease inhibitors to increase urea-N efficiency in soil and Kentucky blue-grass(Poa Pratensis L.) turf. The activity of urease inhibitors Phenyiphosphorodiamjdate(ppD) and N-(n-butyl) thiophosphoric triamjde(NBPT) measured to break-down ammonia volatilization. The soil and turf used in this project were from the fairway in one of the Korean gof course. The researches were carried out for two weeks to measure the urease activities on urea hydrolysis under four temperatures (10~ 40$^{\circ}C$) and for one week on turfgrass using forced-draft system. Results indicated that Urea-N involves considerable loss through gaseous NH$_3$ by urease activities in plant-soil systems. Urease inhibitors PPD and NBPT have potential value for increasing N use efficiency by reduing NH$_3$ volatilization. NBPT deserves futher evaluation as fertilizer amendment than PPD use of urea in turf industries.

  • PDF

Performance Analysis of a Hydrodynamic Separator for Treating Particulate Pollutants in Highway Rainfall Runoff

  • Yu, Jianghua;Yi, Qitao;Kim, Young-Chul
    • Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.262-269
    • /
    • 2009
  • This study examined the separation characteristics of particles in the rainfall runoff from paved roads using a ${\varphi}7.5$ cm hydrocyclone. The volume fraction and total suspended solids concentrations in the overflow and underflow from the hydrocyclone, as well as the separation efficiency were determined. The results indicated that the overflow volume increased with increasing operational pressure, but decreased with decreasing ratio of underflow outlet to inlet sizes ($D_u/D_i$), while the underflow to overflow volumes showed contrary behavior. The total suspended solid (TSS) concentration ratio between the overflow and inflow ($TSS_{over/in}$) decreased as a function of the operational pressure, while the corresponding ratio of underflow to inflow ($TSS_{under/in}$) increased. There was no visible difference in the $TSS_{over/in}$ with increasing $D_u/D_i$ ratio, but the $TSS_{under/in}$ decreased sharply. The particle removal efficiency was mainly affected by the particle size.

A Study of Performance and Internal Flow in a New Type of Sewage Pump

  • Nishi, Yasuyuki;Fukutomi, Junichiro
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.3
    • /
    • pp.239-247
    • /
    • 2009
  • Sewage pumps are designed with a wide flow channel by, for example, sacrificing some efficiency and reducing the number of blades, in order to prevent plugging with foreign bodies. However, the behavior of foreign bodies which actually flow into a pump is extremely complex, and there are questions about whether the presumed foreign bodies will actually pass through. This paper proposes a new type of sewage pump impeller designed to further improve pump efficiency and performance in passing foreign bodies. This sewage pump impeller has a structure in which the suction flow channel of a closed type non-clog pump is wound in a helical spiral. The focus of this research was to investigate pump performance and internal flow in this single blade sewage pump impeller. The results clearly indicated the following facts: The developed sewage pump impeller exhibits high efficiency over a wide range of flow rates; internal flow of the pump is very complicated; and the internal flow state varies greatly when the flow rate changes.

Influence of Nickel Electroplating on Hydrogen Chloride Removal of Activated Carbon Fibers

  • Park, Soo-Jin;Jin, Sung-Yeol;Ryu, Seung-Kon
    • Carbon letters
    • /
    • v.5 no.4
    • /
    • pp.186-190
    • /
    • 2004
  • In this work, a nickel metal (Ni) electroplating on the activated carbon fiber (Ni/ACFs) surfaces was carried out to remove the toxic hydrogen chloride (HCl) gas. The surface properties of the treated ACFs were determined by using nitrogen adsorption isotherms at 77 K, SEM, and X-ray diffraction (XRD) measurements. HCl removal efficiency was confirmed by a gas-detecting tube technique. As a result, the nickel metal contents on the ACF surfaces were increased with increasing the plating time. And, it was found that the specific surface area or the micropore volume of the ACFs studied was slightly decreased as increasing the plating time. Whereas, it was revealed that the HCl removal efficiency containing nickel metal showed higher efficiency values than that of untreated ACFs. These results indicated that the presence of nickel metal on the ACF surfaces played an important role in improving the HCl removal over the Ni/ACFs, due to the catalytic reactions between nickel and chlorine.

  • PDF

Fabrication and Characterization of Solar Cells Using Cast Polycrystalline Silicon (Cast Poly-Si을 이용한 태양전지 제작 및 특성)

  • 구경완;소원욱;문상진;김희영;홍봉식
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.2
    • /
    • pp.55-62
    • /
    • 1992
  • Polycrystalline silicon ingots were manufactured using the casting method for polycrystalline silicon solar cells. These ingots were cut into wafers and ten n$^{+}$p type solar cells were made through the following simple process` surface etching, n$^{+}$p junction formation, metalization and annealing. For the grain boundary passivation, the samples were oxidized in O$_2$ for 5 min. at 80$0^{\circ}C$ prior to diffusion in Ar for 100 min. at 95$0^{\circ}C$. The conversion efficiency of polycrystalline silicon solar cells made from these wafers showed about 70-80% of those of the single crystalline silicon solar cell and superior conversion efficiency, compared to those of commercial polycrystalline wafers of Wacker Chemie. The maximum conversion efficiency of our wafers was indicated about 8%(without AR coating) in spite of such a simple fabrication method.

  • PDF

A Comparative Study on the Human Resource Efficiency between the Korean and Japanese Municipal Hospitals using Data Envelopment Analysis (DEA를 이용한 한국과 일본 공공병원의 인적자원 효율성 평가)

  • Nam, Sang-Yo
    • Korea Journal of Hospital Management
    • /
    • v.12 no.1
    • /
    • pp.51-74
    • /
    • 2007
  • This study applied Data Envelopment Analysis to a set of Korean Public Corporation Medical Centers and Japanese Municipal Hospitals to compare their relative human resource efficiencies. Based on the data provided on the inputs and outputs, the analysis showed Japanese municipal hospitals were relatively efficient than Korean hospitals. The result of analysing BCC model shows 5 hospitals in Japan and 7 in Korea with an efficiency rating of less than 1 as considered relatively inefficient. For the inefficient hospitals the manner in which inefficient hospitals may be made efficient were indicated by the managerial strategies based on dual variables. A subsequent analysis of Wilcoxon rank-sum test revealed that the medical revenue per medical expense, labor cost per value added revenue were statistically significant between efficient and inefficient Korean hospitals and medical revenue per medical expense, labor cost per value added revenue, bed occupancy rate, average length of stay, rate of personnel expenses per medical revenue were statistically significant between efficient and inefficient Japanese hospitals.

  • PDF

Deinking of Computer Printed Out and White Ledger (백상지 고지의 탈묵)

  • 한신호
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.1
    • /
    • pp.48-56
    • /
    • 2000
  • The objective of this study was to investigate the enzymatic deinking technology. Office recycled papers such as computer printed out(CPO) and white ledger(WL) were used in the evaluation of four different deinking conditions ; alkaline deinking , neutral deinking and enzymatic deinking at alkaline and neutral pH. Filltering pads were prepared after flotation deinking to measure brighteness gain and ink removal efficiency. Three different surfactants were also used in the evaluation of deinking efficiency including surface chemical properties by measuring foam height and stability, surface tension and cloud point of views. The results indicated that the neutral deinking method with enzyme and surfactant addition showed highest deinking efficiency of office recycled papers.

  • PDF

Efficient Screening of Surfactant for Soil Washing (토양세척을 위한 계면활성제의 효과적 선정)

  • 신현무;이상화
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1999.10a
    • /
    • pp.7-11
    • /
    • 1999
  • Soil washing process being operated in ex-situ mode using surfactants could be appropriate one of the most effective one for remediation. The choice of surfactants has been considered most significantly to accomplish tile reduction of expenditure and the increase of efficiency. This study was carried out screening test and solubility, washing experiment, and surfactant sorption experiments for 18 kinds of surfactant obtained. Results from each surfactant's PSR obtained by the slope indicated that nonionic surfactants have much higher solubility for HOCs than anion surfactants for that. The washing experiment to find out a removal efficiency of each surfactant's TPH, LE1017 and LE1019 showed high removal efficiency. Through on the result of estimating the extent of adsorption of surfactants for soils, nonion surfactants showed higher adsorption to soils than anion surfactants.

  • PDF

Optimization for Microalgae Harvesting Using Mg-Sericite Flocculant (Mg-Sericite 응집제를 이용하여 미세조류 회수 최적화 연구)

  • Choi, Hee-Jeong
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.3
    • /
    • pp.328-333
    • /
    • 2015
  • In this study, Mg-Sericite was used as a flocculant to harvest freshwater microalgae, Chlorella. vulgaris. Mg-Sericite separated successfully >95% of the C. vulgaris at the following optimal parameters: Mg/Si mol ratio 1.25 to 1.50, mixing time of 20 min and settling time of 20 min. The harvesting efficiency was pH dependent. The highest harvesting efficiency ($99{\pm}0.3%$) was obtained at Mg/Si mol ratio 1.5 and pH 9 to 11. These results indicated that a biopolymer, Mg-Sericite, can be a promising flocculant due to its high efficiency, low dose requirements, short mixing and settling times. This harvesting method is helpful to lower the production cost of algae for biodiesel.