• Title/Summary/Keyword: Indicate System

Search Result 4,387, Processing Time 0.032 seconds

Injection Molding 3D CAE Applications for Estimating Filling Imbalance Using a New Runner system meshing (새로운 3D 멧싱 기법으로 충전 불균형을 예측할수 있는 사출성형 CAE 활용)

  • Go, Seung-Woo;Jung, Su-Jung;Seo, Sang-Hun;Jeong, Yeong-Deug
    • 한국금형공학회:학술대회논문집
    • /
    • 2008.06a
    • /
    • pp.121-127
    • /
    • 2008
  • Nowdays CAE has been used for almost all injection molding designs in order to find the best injection conditions. Almost all CAE use 2-D mesh, but the CAE with 2-D mesh can't indicate such as jetting, flow-mark and filling imbalance in multi cavity mold. In this study, we suggested a new 3D meshing. the method which can indicate the filling imbalance in geometrically balanced runner system with Mold Flow MPI 6.1 and we found out that the calculation times are saved. As a feasibility study, we verified that Melt Flipper, RC Pin etc appeared the balanced filling behaviors. of geometrically balanced runner system and Melt Flipper, filling imbalance was indicated more accurately.

  • PDF

Theoretical and Experimental Evaluation of R502 Alternatives in Low Temperature Applications (저온용 R502 대체 냉매의 이론 및 실험적 평가)

  • Kwon, S.L.;Park, Y.B.;Jung, D.S.;Kim, C.B.;Kang, D.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.4
    • /
    • pp.654-666
    • /
    • 1995
  • R502 has been extensively used as a working fluid in transport refrigerating vehicles and low temperature refrigerating machines but is to be phased out by the end of 1995 due to ozone layer depletion problem. In this study, both theoretical cycle analysis and experiments were carried out to examine the best substitutes for R502. Theoretical results indicate that the alternatives available in the market today may replace R502 without significant changes in the system without suction line heat exchanger(SLHX). When the system contains a SLHX, however, COPs of the alternatives increase up to approximately 15~20% than those without the SLHX. But simultaneously, the discharge temperatures of the compressor also increrease significantly with the SLHX. Actual test results obtained from the experiment with a transport vehicle's refrigerator indicate the similar trend as those of the theoretical results. Especially, HFCs and their mixtures show lower discharge temperature than those of R502, which is one of the desirable features. Further research is needed to study the effect of the SLHX on the performance of the real machine as well as on the oil return for reliability of the system.

  • PDF

Bi-directional fault analysis of evaporator inspection system

  • Kang, Dae-Ki;Kang, Jeong-Jin
    • International journal of advanced smart convergence
    • /
    • v.1 no.1
    • /
    • pp.57-60
    • /
    • 2012
  • In this paper, we have performed a safety analysis on an automotive evaporator inspection system. We performed the bi-directional analysis on the manufacturing line. Software Fault Tree Analysis (SFTA) as backward analysis and Software Failure Modes, Effects, & Criticality Analysis (SFMECA) as forward analysis are performed alternately to detect potential cause-to-effect relations. The analysis results indicate the possibility of searching and summarizing fault patterns for future reusability.

Development of an Intelligent Operation Support System (지능적 조업 지원 시스템의 개발)

  • 이영학;이동희;한종훈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.391-391
    • /
    • 2000
  • Manufacturing process generally exhibits major or minor variations due to deviation of raw materials, equipment degradation, controller malfunction, and so on. Extensive research based on multivariate statistical process control has been done to monitor the unstable states and indicate a corrective action. A prototype of intelligent operation support system ("ISYS-MSPC") has been developed as a tool that supports the enhanced operation to guarantee the high productivity and a uniform high quality product. This system has been applied to the industrial batch and continuous processes and its performance has been validated .

  • PDF

Robust Controller Design for Uncertain Dynamic System Using Time Delay Control and Sliding Mode Control Method (시간지연 제어와 슬라이딩모드 제어기법을 이용한 불확실한 동적 시스템의 강인 제어기 설계)

  • 박병석;이인성;윤지섭;강이석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.225-225
    • /
    • 2000
  • We propose the hybrid robust controller for TDC(Time Delay Control) and SMC(Sliding Mode Control) method. TDC and SMC deal with the time-varying system parameters, unknown dynamics and unexpected disturbance. This controller is applied to follow the desired reference model for the uncertain time-varying overhead crane. The control performance is evaluated through simulation. The theoretical results indicate That the proposed controller shows excellent performance to an overhead crane with the uncertain time-varying parameters and disturbance.

  • PDF

Voltage Controller Design of Synchronous Generator by Pole Assignment (극배치에 의한 동기발전기의 전압제어기 설계)

  • Yim, Han-Suck
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.12
    • /
    • pp.472-484
    • /
    • 1985
  • A design of robust voltage controller for high speed excitation of synchronous machine was carried out by pole assignment techniques. An affine map from characteristic polynomial coefficients to feedback parameters is formulated in order to place the system eigen values in the desired region. The feedback parameters determined from linearized model are tested on nonlinear model subjecting it to small disturbances and system faults to show the effectiveness of the controller designed by the proposed technique. The results obtained indicate that the controller presented improves the dynamic stability and system performances of conventionally controlled synchronous machine significantly.

  • PDF

PMSM Position Control with a SUI PID Controller

  • Abu El-Sebah, Mohamed I.
    • Journal of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.171-175
    • /
    • 2010
  • This paper introduces the application of a SUI PID controller for permanent magnet (PM) drive systems. The drive system model is developed via FO control. Simulation of the system is carried out to predict the performance at no load and under load. The results and comparisons indicate that application of a SUI PID controller is effective for sensorless PM drive systems.

Protection Assessment using Reduced Power System Fault Data

  • Littler, T.B.
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.172-177
    • /
    • 2007
  • Wavelet transforms provide basis functions for time-frequency analysis and have properties that are particularly useful for the compression of analogue point on wave transient and disturbance power system signals. This paper evaluates the compression properties of the discrete wavelet transform using actual power system data. The results presented in the paper indicate that reduction ratios up to 10:1 with acceptable distortion are achievable. The paper discusses the application of the reduction method for expedient fault analysis and protection assessment.

Analysis of Preferences Based on Purchasing Frequencies and Recognitions of Sizing System for Female Garments (여성복의 구매빈도에 의한 선호도 및 치수 시스템 인지도에 관한 분석)

  • Koo, Hee-Kyung
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.13 no.1
    • /
    • pp.125-134
    • /
    • 2011
  • The research is a survey and analysis of female apparel preferences, and recognition of the KS sizing system for adult female garments. The practical surveys in this research are examined by total number of subjects, 200 women who are living in Seoul, South Korea. The homogeneity test using Chi-square statistics, and the analysis of frequencies and ratios of contingency tables were performed with the data which are classified by age, education level, income level and housing modalities. The findings in this study are as follows: 1. Women's preferences for purchasing female garments indicate significant differences between subjects, such as age, education level, income level and housing modalities. Moreover, the following five types of adult female garments were analyzed in this study: upper garment, lower garment, one-piece apparel, sportswear and sleepwear. The results of the preference study show an indirect understanding of the KSK 0051 classification system for subjects of the survey. Therefore the preference study can be used as a pilot study for the sizing recognition survey. 2. Women's recognition of the KSK 0051 sizing system for adult female adult garments do not indicate significant differences based on the characteristics of age, education level, income level and housing modalities. The low recognition of the KS sizing system is due to too many details and complex numbers of application for users. Therefore, the sizing system should be simplified and rearranged to be more effective and have more recognizable categories.

  • PDF

Na-Ion Anode Based on Na(Li,Ti)O2 System: Effects of Mg Addition

  • Kim, Soo Hwa;Bae, Dong-Sik;Kim, Chang-Sam;Lee, June Gunn
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.3
    • /
    • pp.282-287
    • /
    • 2016
  • This study involves enhancing the performance of the $Na(Li,Ti)O_2$ system as an Na-ion battery anode with the addition of Mg, which partially replaces Li ions. We perform both computational and experimental approaches to achieve a higher reversible capacity and a faster transport of Na ions for the devised system. Computational results indicate that the $Na(Li,Mg,Ti)O_2$ system can provide a lower-barrier path for Na-ion diffusion than can a system without the addition of Mg. Experimentally, we synthesize various $Na_z(Li_y,Mg_x,Ti)O_2$ systems and evaluate their electrochemical characteristics. In agreement with the theoretical study, Mg addition to such systems improves general cell performance. For example, the prepared $Na_{0.646}(Li_{0.207}Mg_{0.013}Ti_{0.78})O_2$ system displays an increase in reversible capacity of 8.5% and in rate performance of 13.5%, compared to those characteristics of a system without the addition of Mg. Computational results indicate that these improvements can be attributed to the slight widening of the Na-$O_6$ layer in the presence of Mg in the $(Li,Ti)O_6$ layer.