• Title/Summary/Keyword: Index Configuration

Search Result 141, Processing Time 0.027 seconds

An Anatomic Study of the Extensor Tendons of the Human Hand (수배부의 신전건에 대한 해부학적 연구)

  • Kang, Moon-Seok;Jung, Sung-Gyun;Nam, Seoung-Min;Shin, Ho-Seong;Kim, Yong-Bae
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.836-844
    • /
    • 2011
  • Purpose: Hands are the chief organs for physically manipulating the environment, using anywhere from the roughest motor skills to the finest, and since the fingertips contain some of the densest areas of nerve endings on the human body, they are continuously used organ with complex functions, and therefore, often gets injured. To prevent any functional loss, a detailed anatomical knowledge is required to have a perfect surgical treatment. Also it is necessary to have a thorough understanding of arrangements of the human extensor tendons and intertendinous connections when tenoplasty or tendon transfer is required. We performed a study of the arrangements of the human extensor tendons and the configuration of the intertendinous connections over the dorsum of the wrist and hand. Methods: A total of 58 hands from Korean cadavers were dissected. The arrangements of extensor indicis proprius, extensor digitorum communis, and extensor digiti minimi tendons and intertendinous connections were studied. Results: The most common distribution patterns of the extensor tendons of the fingers were as follows: a single extensor indicis proprius (EIP) tendon which inserted ulnar to the extensor digitorum-index (EDC-index); a single EDC-index; a single EDC-middle; a double EDC-ring; an absent EDC-little; a double extensor digiti minimi (EDM), a single EDC-index (98.3%), a single EDC-middle (62%), a double EDC-ring (50%), and an absent (65.5%) or a single (32.8%) EDC-little. A double (70.6%) EDM tendons were seen. Intertendinous connections were classified into 3 types: type 1 with thin filamentous type, type 2 with a thick filamentous type, and type 3 with a tendinous type subdivided to r shaped 3r type and y shaped 3y type. The most common patterns were type 1 in the 2nd intermetacarpal space, type 2 in the 3rd intermetacarpal space, and type 3r in the 4th intermetacarpal space. And in the present study, we observed one case of the extensor digitorum brevis manus (EDBM) on the boht side. Conclusion: A knowledge of both the usual and possible variations of the extensor tendon and the intertendinous connection is useful in the identification and repair of these structures.

Measurement of electron density of atmospheric pressure Ar plasma jet by using Michelson interferometer

  • Lim, Jun-Sup;Hong, Young June;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.195.1-195.1
    • /
    • 2016
  • Currently, as Plasma application is expanded to the industrial and medical industrial, low temperature plasma applications became important. Especially in medical and biology, many researchers have studied about generated radical species in atmospheric pressure low temperature plasma directly adapted to human body. Therefore, so measurement their plasma parameter is very important work and is widely studied all around world. One of the plasma parameters is electron density and it is closely relative to radical production through the plasma source. some kinds of method to measuring the electron density are Thomson scattering spectroscopy and Millimeter-wave transmission measurement. But most methods have very expensive cost and complex configuration to composed of experiment system. We selected Michelson interferometer system which is very cheap and simple to setting up, so we tried to measuring electron density by laser interferometer with laser beam chopping module for measurement of temporal phase difference in plasma jet. To measuring electron density at atmospheric pressure Ar plasma jet, we obtained the temporal phase shift signal of interferometer. Phase difference of interferometer can occur because of change by refractive index of electron density in plasma jet. The electron density was able to estimate with this phase difference values by using physical formula about refractive index change of external electromagnetic wave in plasma. Our guiding laser used Helium-Neon laser of the centered wavelength of 632 nm. We installed chopper module which can make a 4kHz pulse laser signal at the laser front side. In this experiment, we obtained more exact synchronized phase difference between with and without plasma jet than reported data at last year. Especially, we found the phase difference between time range of discharge current. Electron density is changed from Townsend discharge's electron bombardment, so we observed the phase difference phenomenon and calculated the temporal electron density by using phase shift. In our result, we suggest that the electron density have approximately range between 1014~ 1015 cm-3 in atmospheric pressure Ar plasma jet.

  • PDF

A simple approach for quality evaluation of non-slender, cast-in-place piles

  • Zhang, Ray Ruichong
    • Smart Structures and Systems
    • /
    • v.4 no.1
    • /
    • pp.1-17
    • /
    • 2008
  • This study proposes a conceptual framework of in-situ vibration tests and analyses for quality appraisal of non-slender, cast-in-place piles with irregular cross-section configuration. It evaluates a frequency index from vibration recordings to a series of impulse loadings that is related to total soil-resistance forces around a pile, so as to assess if the pile achieves the design requirement in terms of bearing capacity. In particular, in-situ pile-vibration tests in sequential are carried out, in which dropping a weight from different heights generates series impulse loadings with low-to-high amplitudes. The high-amplitude impulse is designed in way that the load will generate equivalent static load that is equal to or larger than the designed bearing capacity of the pile. This study then uses empirical mode decomposition and Hilbert spectral analysis for processing the nonstationary, short-period recordings, so as to single out with accuracy the frequency index. Comparison of the frequency indices identified from the recordings to the series loadings with the design-based one would tell if the total soil resistance force remains linear or nonlinear and subsequently for the quality appraisal of the pile. As an example, this study investigates six data sets collected from the in-situ tests of two piles in Taipu water pump project, Jiangshu Province of China. It concludes that the two piles have the actual axial load capacity higher than the designed bearing capacity. The true bearing capacity of the piles under investigation can be estimated with accuracy if the amplitude of impact loadings is further increased and the analyses are calibrated with the static testing results.

Improvement Plans on Defect Consulting Report in an Apartment Building through Analyzing on Formal Index and Quantitative Index (형식 및 질적요소 체계분석을 통한 공동주택 하자감정서의 개선방안)

  • Park, Jun-Mo;Seo, Deok-Seok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.3
    • /
    • pp.195-206
    • /
    • 2014
  • The main issue of defect dispute is consulting, reviewing, and finally judging as an arbiter. A defect consulting is represented a defect consulting report, but a business custom and a standard of judgment are different each consultants, and have many problems. This study reviews literature studies and institutional researches, set up a research structure. it has 7 indexes that 5 indexes are formal indexes, and the other are qualitative indexed. As a result of case study, formal indexes are respect on the whole. However, each appraiser has different ideas, and, is expected to delay on fixing a construction lawsuit practice. This study suggests to improve a defect consulting report, it is followed. In formal part, suggested to change configuration is adjusted and integrated similar items. In qualitative part, an evaluation system for appraiser and an education program for engineers is suggested.

Aspheric Lens Measurements by Digital Holographic Microscopy and Liquid (액체와 Digital Holographic Microscopy을 이용한 비구면 렌즈 측정 연구)

  • Kim, Doocheol;Shin, Sanghoon;Yu, Younghun
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.6
    • /
    • pp.318-323
    • /
    • 2013
  • Digital holographic microscopy allows optical path difference measurement. Optical path difference depends on both the refractive index and the morphology of the sample. When interference fringes are very closely spaced, the phase data contain high frequencies where $2{\pi}$ ambiguities cannot be resolved. The immersion testing method, which is a transmission test while the sample is immersed in liquid, is very effective in reducing high frequency fringes in transmission measurements so that large dynamic range testing is possible for a non-null configuration. We developed a digital holographic microscope using liquid that can measure the high numerical aperture aspheric morphology of a sample. This system provides highly precise three-dimensional information on the sample. By improving the experimental method, choosing liquids which have similar refractive index to the sample, we can measure more accurate three-dimensional information on the samples.

Super Resolution using Dictionary Data Mapping Method based on Loss Area Analysis (손실 영역 분석 기반의 학습데이터 매핑 기법을 이용한 초해상도 연구)

  • Han, Hyun-Ho;Lee, Sang-Hun
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.3
    • /
    • pp.19-26
    • /
    • 2020
  • In this paper, we propose a method to analyze the loss region of the dictionary-based super resolution result learned for image quality improvement and to map the learning data according to the analyzed loss region. In the conventional learned dictionary-based method, a result different from the feature configuration of the input image may be generated according to the learning image, and an unintended artifact may occur. The proposed method estimate loss information of low resolution images by analyzing the reconstructed contents to reduce inconsistent feature composition and unintended artifacts in the example-based super resolution process. By mapping the training data according to the final interpolation feature map, which improves the noise and pixel imbalance of the estimated loss information using a Gaussian-based kernel, it generates super resolution with improved noise, artifacts, and staircase compared to the existing super resolution. For the evaluation, the results of the existing super resolution generation algorithms and the proposed method are compared with the high-definition image, which is 4% better in the PSNR (Peak Signal to Noise Ratio) and 3% in the SSIM (Structural SIMilarity Index).

Buckling behaviors of FG porous sandwich plates with metallic foam cores resting on elastic foundation

  • Abdelkader, Tamrabet;Belgacem, Mamen;Abderrahmane, Menasria;Abdelhakim, Bouhadra;Abdelouahed, Tounsi;Mofareh Hassan, Ghazwani;Ali, Alnujaie;S.R., Mahmoud
    • Structural Engineering and Mechanics
    • /
    • v.85 no.3
    • /
    • pp.289-304
    • /
    • 2023
  • The main objective of this paper is to study the effect of porosity on the buckling behavior of thick functionally graded sandwich plate resting on various boundary conditions under different in-plane loads. The formulation is made for a newly developed sandwich plate using a functional gradient material based on a modified power law function of symmetric and asymmetric configuration. Four different porosity distribution are considered and varied in accordance with material propriety variation in the thickness direction of the face sheets of sandwich plate, metal foam also is considered in this study on the second model of sandwich which containing metal foam core and FGM face sheets. New quasi-3D high shear deformation theory is used here for this investigate; the present kinematic model introduces only six variables with stretching effect by adopting a new indeterminate integral variable in the displacement field. The stability equations are obtained by Hamilton's principle then solved by generalized solution. The effect of Pasternak and Winkler elastic foundations also including here. the present model validated with those found in the open literature, then the impact of different parameters: porosities index, foam cells distribution, boundary conditions, elastic foundation, power law index, ratio aspect, side-to-thickness ratio and different in-plane axial loads on the variation of the buckling behavior are demonstrated.

Characteristic Behavior of High-Strength Concrete Columns under Simulated Seismic Loading

  • Hwang, Sun-Kyoung
    • International Journal of Concrete Structures and Materials
    • /
    • v.18 no.2E
    • /
    • pp.79-87
    • /
    • 2006
  • The main objective of this research is to examine the behavior of high-strength concrete(HSC) columns. Eight test columns in one-third scale were tested under the conditions of cyclic lateral force and a constant axial load equal to 30% of the column axial load capacity. The $200{\times}200mm$ square columns were reinforced with eight DB bars constituting a longitudinal steel ratio of 2.54% of the column cross-sectional area. The main experimental parameters were volumetric ratio of transverse reinforcement(${\rho}_s$=1.58, 2.25 percent), tie configuration(Type H, Type C, Type D) and tie yield strength($f_{yh}$=548.8 and 779.1 MPa). It was found that the hysteretic behaviour and ultimate deformability of HSC columns were influenced by the amount and details of transverse reinforcement in the potential plastic hinge regions. Columns of transverse reinforcement in the amount 42 percent higher than that required by seismic provisions of ACI 318-02 showed ductile behavior. At 30% of the axial load capacity, it is recommended that the yield strength of transverse reinforcement be held equal to or below 548.8 MPa. Correlations between the calculated damage index and the damage progress are proposed.

A Study on Elementary School Girls' Lower Body Type Analysis (학령후기 여아의 하반신 체형분석에 관한 연구)

  • 석은영;김혜경
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.3
    • /
    • pp.345-352
    • /
    • 2000
  • The purpose of this study was to classify lower body types of elementary school girls. The subjects for anthropometric study were 368 girls aged from 10 to 11. Factor analysis, cluster analysis, discriminant analysis, and analysis of variance were performed for statistical analysis of the data. Four lower body construction factors were extracted by the factor analysis of antropometric measurements. The factors extracted were lower body fatness factor, lower body height factor, lower body length from the waist to the crotch factor, and lower body configuration factor. On the basis of the cluster analysis, three different lower body types were categorized. Type 1 was short and small sized type and 42.4% of subjects belonged under this type. Type 2 was tall and fat type and 22.3% of subjects belonged under this type. Type 3 was the most similar to the average type having the largest waist-hip drop value and 35.3% of subjects belonged under this type. Discriminant analysis showed 7 discriminant factors that can classify the children's lower body type were Rohrer's index, height, fibulae length, waist girth, ilio cristale girth, trochanter girth, and weight.

  • PDF

Common-path OCT Image Using Partial Reflecting Probe (부분 반사 프로브를 사용한 공통경로 OCT 이미지 획득)

  • Park, Jae-Seok;Jeong, Myung-Yung;Kim, Chang-Seok;Han, Jae-Ho;Kang, Jin-U.
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.2
    • /
    • pp.103-107
    • /
    • 2008
  • Unlike conventional optical coherence tomography systems based on Michelson interferometer, we suggest a common-path OCT system, which does not include a separated configuration between reference signal and sample signal. We optimize the refractive index of partial reflecting probe to induce a balanced intensity of the reference signal. At the end of the probe, convex lens was optimally fabricated to get images of biological samples in the position of focus. Using the experimental system, we could get 2-D images of various biological samples.