• Title/Summary/Keyword: InDong

Search Result 90,145, Processing Time 0.128 seconds

Evaluation of Antimicrobial Activity of Steamed and Fermented Asparagus cochinchinenesis (증숙 및 발효한 천문동의 항균활성과 특성)

  • Lee, Seung-Min;Kim, Su-In;Kang, Moon-Sun;Lee, Chung-Yeol;Hwang, Dae-Youn;Lee, Hee-Sup;Kim, Dong-Seob
    • Food Engineering Progress
    • /
    • v.21 no.2
    • /
    • pp.143-149
    • /
    • 2017
  • This study was carried out to investigate antimicrobial activity and characteristics of Asparagus cochinchinenesis which was steamed and fermented with lactic acid bacteria. A. cochinchinensis was prepared to steaming process which was washed and freeze dried. A. cochinchinensis was steamed at $95^{\circ}C$ for 12 h and dried by hot air at $50^{\circ}C$ for 24 h. After steaming process, A. cochinchinensis was fermented with lactic acid bacteria (Leuconostoc mesenteroides 4395, Lactobacillus sakei 383 and Lactobacillus plantarum KCCM 11322). Ethyl acetate extracts of fermented A. cochinchinensis had antimicrobial activities for the respiratory disease bacteria (Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa and Escherichia coli). A. cochinchinensis had highest antimicrobial activity for the P. aeruginosa which fermented with L. mesenteroides 4395. The minimum inhibition concentration (MIC) of A. cochinchinensis fermented with L. mesenteroides 4395 was 10 mg/mL for S. aureus, S. epidermidis, E. coli and 5 mg/mL for P. aeruginosa. The MIC of A. cochinchinensis fermented with L. sakei 383 and A. cochinchinensis fermented with L. plantarum KCCM 11322 were the same. Total sugar was decreased from $863.33{\pm}17.47mg/mL$ to $722.67{\pm}5.51mg/mL$ during the steaming process. But reducing sugar was increased from $99.36{\pm}1.32mg/mL$ to $109.29{\pm}2.71mg/mL$ during the steaming process. Total sugar was decreased to 301.50-361.42 mg/mL and reducing sugar was decreased to 27.39-62.20 mg/mL during the fermentation process.

Development of an Automatic Grafting Robot for Fruit Vegetables using Image Recognition (영상인식 기술 이용 과채류 접목로봇 개발)

  • Kang, Dong Hyeon;Lee, Si Young;Kim, Jong Koo;Park, Min Jung;Son, Jin Kwan;Yun, Sung-Wook
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.322-327
    • /
    • 2019
  • This study was conducted to improve the performance of automatic grafting robot using image recognition technique. The stem diameters of tomatoes and cucumber at the time of grafting were $2.5{\pm}0.3mm$ and $2.2{\pm}0.2mm$ for scions and $3.1{\pm}0.7mm$ and $3.6{\pm}0.3mm$ for rootstocks, respectively. The grafting failure was occurred when the different height between scions and rootstocks were over 4 mm and below 2 mm due to the small contact area of both cutting surface. Therefore, it was found that the height difference at the cutting surface of 3 mm is appropriate. This study also found that grafting failure was occurred when the stem diameters of both scions and rootstocks were thin. Therefore, it was suggested to use at least one stem with thicker than the average stem diameter. Field survey on the cutting angle of stems by hand were ranged from 13 to 55 degree for scions and 15 to 67 degree for rootstocks, respectively, which indicates that this could cause the grafting failure problem. However, the automatic grafting robot developed in this study rotates the seedlings 90 degree and then the stems are cut using a cutting blade. The control part of robot use all images taken from grafting process to determine the distance between a center of both ends of stem and a gripper center and then control the rotation angle of a gripper. Overall, this study found that The performance of automatic grafting robot using image recognition technique was superior with the grafting success rates of cucumber and tomato as $96{\pm}3.2%$ and $95{\pm}4%$, respectively.

Optimization for Ammonia Decomposition over Ruthenium Alumina Catalyst Coated on Metallic Monolith Using Response Surface Methodology (반응표면분석법을 이용한 루테늄 알루미나 메탈모노리스 코팅촉매의 암모니아 분해 최적화)

  • Choi, Jae Hyung;Lee, Sung-Chan;Lee, Junhyeok;Kim, Gyeong-Min;Lim, Dong-Ha
    • Clean Technology
    • /
    • v.28 no.3
    • /
    • pp.218-226
    • /
    • 2022
  • As a result of the recent social transformation towards a hydrogen economy and carbon-neutrality, the demands for hydrogen energy have been increasing rapidly worldwide. As such, eco-friendly hydrogen production technologies that do not produce carbon dioxide (CO2) emissions are being focused on. Among them, ammonia (NH3) is an economical hydrogen carrier that can easily produce hydrogen (H2). In this study, Ru/Al2O3 catalyst coated onmetallic monolith for hydrogen production from ammonia was prepared by a dip-coating method using a catalyst slurry mixture composed of Ru/Al2O3 catalyst, inorganic binder (alumina sol) and organic binder (methyl cellulose). At the optimized 1:1:0.1 weight ratio of catalyst/inorganic binder/organic binder, the amount of catalyst coated on the metallic monolith after one cycle coating was about 61.6 g L-1. The uniform thickness (about 42 ㎛) and crystal structure of the catalyst coated on the metallic monolith surface were confirmed through scanning electron microscopy (SEM) and X-ray diffraction (XRD) analysis. Also, a numerical optimization regression equation for NH3 conversion according to the independent variables of reaction temperature (400-600 ℃) and gas hourly space velocity (1,000-5,000 h-1) was calculated by response surface methodology (RSM). This model indicated a determination coefficient (R2) of 0.991 and had statistically significant predictors. This regression model could contribute to the commercial process design of hydrogen production by ammonia decomposition.

Synthesis of Uniform Silica Nanoparticles using Tap, Industrial, and Stream water and Their Application to Electro-responsive Smart Fluid System (상수, 공업용수, 및 하천수를 활용한 균일한 실리카 나노입자 합성 및 전기감응형 스마트유체로의 응용)

  • Ha-Yeong Kim;Suk Jekal;Neunghi Lee;Minki Sa;Dong Hyun Kim;Min Sang Kim;Jiwon Kim;Chang-Min Yoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.1
    • /
    • pp.47-56
    • /
    • 2023
  • This study describes the successful synthesize strategy for the silica nanoparticles utilizing various water sources, including tap, industrial, and stream waters without using deionized water. Also, as-synthesized silica nanoparticles are employed as dispersive materials for the electro-responsive smart fluid application. Specifically, homogeneous silica nanoparticles with sizes of 500-700nm are successfully prepared in large scale at once (ca. 12.0 g) with the described experimental method and showing similar structural and chemical characteristics with silica nanoparticles synthesized using the deionized water. The size of silica nanoparticles are varied according to the ion conductivity differences of tap, industrial, stream water, and deionized water. The size of silica nanoparticles decresed with the increased ion conductivity, indicating the ion suppression of growth of silica nanoparticles. Moreover, as-synthesized silica nanoparticles from various water sources of electro-responsive characteristic are investigated by the smart fluid application. The smart fluids containing silica nanoparticles synthesized by tap, industrial, and stream water exhibited higher shear stress compared to the deionized water, owing to the more rigid fibril-like structures formed by the smaller silica nanoparticles. Conclusively, uniform silica nanoparticles from various water sources without any purification are able to successfully prepared without usage of deionized water and resulting silica nanoparticles manifested higher electro-responsive performance.

Prognostic Factors after Arthroscopic Treatment of Infectious Knee Arthritis (감염성 슬관절염의 관절경적 치료 이후 예후 인자에 대한 분석)

  • Kang, Sang-Woo;Choi, Eui-Sung;Kim, Dong-Soo;Jung, Ho-Seung;Hong, Seok-Hyun;Go, Ban-Suk
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.1
    • /
    • pp.30-36
    • /
    • 2019
  • Purpose: This study examined the effects of gender, age, underlying disease, duration after onset of symptoms, preoperative invasive procedures, bacterial culture of joint fluid, and stage of infection by the Gachter classification on the prognosis of patients with infectious knee arthritis who underwent arthroscopic surgery. Materials and Methods: From June 2014 to December 2016, 51 patients who underwent arthroscopic surgery for infective knee arthritis were enrolled in this study. The average follow-up period was 14.2±2.1 months (range, 12-20 months). The subjects were 27 men (52.9%) and 24 women (47.1%), with an average age of 55.1±17.6 years (range, 13-84 years). A preoperative evaluation of the joint aspiration with a count of more than 50,000 leukocytes and a polymorphonuclear leukocyte count of 95% or more was performed. All patients underwent arthroscopic surgery and postoperative continuous joint irrigation. Results: The initial mean value of the C-reactive protein decreased from 9.55±6.76 mg/dl (range, 1.51-31.06 mg/dl) to a final mean of 0.74±1.26 mg/dl (range, 0.08-6.77 mg/dl); the mean duration of C-reactive protein normalization was 27.6±18.9 days (range, 8-93 days). Among the 51 patients who received arthroscopic surgery and antibiotics, 44 patients (86.3%) with infectious knee arthritis completed treatment with improved clinical symptoms, such as fever, pain, and edema, and the C-reactive protein decreased to less than 0.5 mg/dl. Finally, 5 cases were treated with two or more arthroscopic operations, and 2 cases were converted to arthroplasty after prosthesis of antibiotic-loaded acrylic cement. Conclusion: The duration of surgery after the onset of symptoms and the stage according to the Gächter classification are important prognostic factors for predicting the successful treatment of infectious knee arthritis. On the other hand, the other factors were not statistically significant. Nevertheless, patients with bacteria cultured from the joint fluids appear to reflect the treatment period because the period of normalization of the C-reactive protein is shorter than that of the control group.

A Study on the Effects of Export Insurance on the Exports of SMEs and Conglomerates (수출보험이 국내 중소기업 및 대기업의 수출에 미치는 영향에 관한 연구)

  • Lee, Dong-Joo
    • Korea Trade Review
    • /
    • v.42 no.2
    • /
    • pp.145-174
    • /
    • 2017
  • Recently, due to the worsening global economic recession, Korea which is a small, export-oriented economy has decreased exports and the domestic economy also continues to stagnate. Therefore, for continued growth of our economy through export growth, we need to analyze the validity of export support system such as export insurance and prepare ways to expand exports. This study is to investigate the effects of Export Insurance on the exports of SMEs as well as LEs. For this purpose, this study conducted Time Series Analysis using data such as export, export insurance acquisition, export price index, exchange rate, and coincident composite index(CCI). First, as a result of the Granger Causality Test, the exports of LEs has found to have a causal relationship with the CCI, and CCI is to have a causal relationship with the short-term export insurance record. Second, the results of VAR analysis show that the export insurance acquisition result and the export price index have a positive effect on the exports of LEs, while the short - term export insurance has a negative effect on the exports of LEs. Third, as a result of variance decomposition, the export of LEs has much more influenced for mid to long term by the short-term export insurance acquisition compared to SMEs. Fourth, short-term export insurance has a positive effect on exports of SMEs. In order to activate short-term export insurance against SMEs, it is necessary to expand support for SMEs by local governments. This study aims to suggest policy implications for establishing effective export insurance policy by analyzing the effects of export insurance on the export of SMEs as well as LEs. It is necessary to carry out a time series analysis on the export results according to the insurance acquisition results by industry to measure the export support effect of export insurance more precisely.

  • PDF

Effects of Percutaneous Balloon Mitral Valvuloplasty on Static Lung Function and Exercise Performance (승모판협착증 환자에서 경피적 풍선확장판막성형술의 폐기능 및 운동부하 검사에 대한 효과)

  • Kim, Yong-Tae;Kim, Woo-Sung;Lim, Chae-Man;Chin, Jae-Yong;Koh, Youn-Suck;Kim, Jae-Joong;Park, Seong-Wook;Park, Seung-Jung;Lee, Jong-Koo;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.1
    • /
    • pp.1-10
    • /
    • 1994
  • Background: Patients with mitral stenosis(MS) have been demonstrated to have a variable degree of pulmonary dysfunction and exercise impairment. The hemodynamic changes of MS can be reversed after percutaneous mitral balloon valvuloplasty(PMV), but the extent and time course of the imporvement in pulmonary function and exercise capacity are not defined. Methods: In order to investigate the early(3 weeks or less)and late(3 months or more) effects of PMV on pulmonary function and determine if the pulmonary dysfunction is reversible even in patients with moderate to severe pulmonary hypertension, we performed the spirometry, measurements of diffusing capacity and lung volumes, and incremental exercise tests in patients with MS before and after PMV. Results: In 46 patients with MS(age: $40{\pm}12$years, male to female ratio: 1:2, mitral valve area: $0.8{\pm}0.2cm^2$) there was a significant increase in FVC(P<0.0025), $FEV_1$(P<0.001), $FEF_{25-75%}$(P<0.001, $FEF_{50%}$(P<0.001), PEF(P<0.0005), MVV(P<0.005), $\dot{V}O_2$max (P<0.0001), and AT(P<0.0001) after average 10 days of PMV. Also there was a significant decrease in DLco(P<0.0001) and DL/VA(P<0.0001). At later($5{\pm}2$months) follow-up in 11 patients, there was no further improvement in any parameters of pulmonary function and exercise test. Twenty nine patients with sinus rhythm were divided into 16 patients with pulmonary arterial pressure(PAP) more than 35mmHg and/or tricuspid regurgitation grade n or more(group A) and 13 patients with PAP less than 35mmHg(group B). Group A Patients had significantly lower FVC(P<0.001), $FEV_1$(P<0.001), DLco(P<0.05), $\dot{V}O_2$ max(P<0.025) and mitral valve area(P<0.025) than group B patients. Group A patients after PMV, showed significant increase in FVC(P<0.001), maximum $O_2$ pulse(P<0.00001) and $\dot{V}O_2$ max(P<0.00025). Both group showed an increase in AT(P<0.0001, P<0.005), but group A showed greater decrease in $\dot{V}E/\dot{V}O_2$ and $\dot{V}E/\dot{V}CO_2$ both at AT(P<0.001, P<0.001) and $\dot{V}O_2$ max(P<0.0001, P<0.0001) after PMV compared with group B. Conclusion: These data suggest that patients with MS can show increased pulmonary function and exercise performance within 1 month after PMV. Patients with moderate to severe pulmonary hypertension had a significant increase in exercise performance compared with those with mild to no pulmonary hypertension and it is thought to be related to a significat decrease of ventilation for a given oxygen consumption at maximum exercise.

  • PDF

A Comparison of Tiotropium 18㎍, Once Daily and Ipratropium 40㎍, 4 Times Daily in a Double-Blind, Double-Dummy, Efficacy and Safety Study in Adults with Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환 환자에서 Tiotropium 1일 1회, 1회 18㎍ 요법과 Ipratropium 1일 4회, 1회 40㎍ 요법의 치료효과 및 안전성 비교)

  • Kim, Seung Joon;Kim, Myung Sook;Lee, Sang Haak;Kim, Young Kyoon;Moon, Hwa Sik;Park, Sung Hak;Lee, Sang Yeub;In, Kwang Ho;Lee, Chang Youl;Kim, Young Sam;Kim, Hyung Jung;Ahn, Chul Min;Kim, Sung Kyu;Kim, Kyung Rok;Cha, Seung Ick;Jung, Tae Hoon;Kim, Mi Ok;Park, Sung Soo;Choi, Cheon Woong;Yoo, Jee Hong;Kang, Hong Mo;Koh, Won Jung;Ham, Hyoung Suk;Kang, Eun Hae;Kwon, O Jung;Lee, Yang Deok;Lee, Heung Bum;Lee, Yong Chul;Rhee, Yang Keun;Shin, Won Hyuk;Kwon, Sung Yeon;Kim, Woo Jin;Yoo, Chul Gyu;Kim, Young Whan;Shim, Young Soo;Han, Sung Koo;Park, Hye Kyung;Kim, Yun Seong;Lee, Min Ki;Park, Soon Kew;Kim, Mi Hye;Lee, Won Yeon;Yong, Suk Joong;Shin, Kye Chul;Choi, Byoung Whui;Oh, Yeon Mok;Lim, Chae Man;Lee, Sang Do;Kim, Woo Sung;Kim, Dong Soon;Jung, Sung Soo;Kim, Ju Ock;Ko, Young Chun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.5
    • /
    • pp.498-506
    • /
    • 2005
  • Background : This study compared the bronchodilator efficacy and safety of tiotropium inhalation capsules ($18{\mu}g$ once daily) with a ipratropium metered dose inhaler (2 puffs of $20{\mu}g$ q.i.d.) in patients with chronic obstructive pulmonary disease (COPD). Method : After the initial screening assessment and a two-week run-in period, patients received either tiotropium $18{\mu}g$ once daily or ipratropium $40{\mu}g$ four times daily over a period of 4 weeks in a double blind, double dummy, parallel group study. The outcome measures were the lung function, the daily records of the peak expiratory flow rate (PEFR), the patients' questionnaire, and the use of concomitant salbutamol. The forced expiratory volume in one second ($FEV_1$) and the forced vital capacity (FVC) were measured 5 minutes before inhalation, and 0.5, 1, 2 and 3 hours after inhaling the study drug on days 0, 14 and 28. Result : In 16 centers, 134 patients with a mean (SD) age of 66 (7) years and a predicted $FEV_1$ of 42 (12)% were analyzed. The trough $FEV_1$ response was significantly higher in the tiotropium group than in the ipratropium group after a four-week treatment period. The weekly mean morning PEFR of the tiotropium group was consistently higher than that of the ipratropium group during the 4-week treatment period with differences ranging from 12.52 to 13.88 l/min, which were statistically significant. Tiotropium was well tolerated by the COPD patients during the 4-week treatment period and had a similar safety profile to ipratropium. Conclusion : This study shows that tiotropium administrated once daily has a superior bronchodilator effect with a similar safety profile in treating COPD patients compared with ipratropium, inhaled four times daily.

Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea (우리나라의 골반 및 요추 엑스선검사에서의 환자선량 권고량)

  • Lee, Kwang-Yong;Lee, Byung-Young;Lee, Jung-Eun;Lee, Hyun-Koo;Jung, Seung-Hwan;Kim, Byung-Woo;Kim, Hyeog-Ju;Kim, Dong-Sup
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.401-410
    • /
    • 2009
  • Purpose : Pelvis and lumbar spine radiography, among various types of diagnostic radiography, include gonads of the human body and give patients high radiation dose. Nevertheless, diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography has not yet been established in Korea. Therefore, the radiation dose that patients receive from pelvis and lumbar radiography is measured and the diagnostic reference level on patient radiation dose for the optimization of radiation protection of patients in pelvis and lumbar spine radiography was established. Methods : The conditions and diagnostic imaging information acquired during the time of the postero-anterior view of the pelvis and the postero-anterior and lateral view of the lumbar spine at 125 medical institutions throughout Korea are collected for analysis and the entrance surface dose received by patients is measured using a glass dosimeter. The diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography to be recommended to the medical institutes is arranged by establishing the dose from the patient radiation dose that corresponds to the 3rd quartile values as the appropriate diagnostic reference level for patient radiation dose. Results : According to the results of the assessment of diagnostic imaging information acquired from pelvis and lumbar spine radiography and the measurement of patient entrance surface dose taken at the 125 medical institutes throughout Korea, the tube voltage ranged between 60~97 kVp, with the average use being 75 kVp, and the tube current ranged between 8~123 mAs, with the average use being 30 mAs. In the posteroanterior and lateral views of lumbar spine radiography, the tube voltage of each view ranged between 65~100 kVp (average use: 78 kVp) and 70~109 kVp (average use: 87 kVp), respectively, and the tube current of each view ranged between 10~100 mAs(average use: 35 mAs) and between 8.9~300 mAs(average use: 64 mAs), respectively. The measurements of entrance surface dose that patients receive during the pelvis and lumbar spine radiography show the following results: in the posteroanterior view of pelvis radiography, the minimum value is 0.59 mGy, the maximum value is 12.69 mGy and the average value is 2.88 mGy with the 1st quartile value being 1.91 mGy, the median being 0.59 mGy, and the 3rd quartile value being 3.43 mGy. Also, in the posteroanterior view of lumbar spine radiography, the minimum value is 0.64 mGy, the maximum value is 23.84 mGy, and the average value is 3.68 mGy with the 1st quartile value being 2.41 mGy, the median being 3.40 mGy, and the 3rd quartile value being 4.08 mGy. In the lateral view of lumbar spine radiography, the minimum value is 1.90 mGy, the maximum value is 45.42 mGy, and the average value is 10.08 mGy with the 1st quartile value being 6.03 mGy, the median being 9.09 mGy and the 3rd quartile value being 12.65 mGy. Conclusions : The diagnostic reference levels for patient radiation dose to be recommended to the medical institutes in Korea is 3.42 mGy for the posteroanterior view of pelvis radiography, 4.08 mGy for the posteroanterior view of lumbar spine radiography, and 12.65 mGy for the lateral view of lumbar spine radiography. Such values are all lower than the values recommended by 6 international organizations including World Health Organization, where the recommended values are 10 mGy for the posteroanterior view of pelvis radiography, 10 mGy for the posteroanterior view of lumbar spine radiography and 30 mGy for the lateral view of lumbar spine radiography.

  • PDF

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.