• Title/Summary/Keyword: In-motion alignment

Search Result 162, Processing Time 0.021 seconds

Inferomedially impacted zygomatic fracture reduction by reverse vector using an intraoral approach with Kirschner wire

  • Jang, Jin Woo;Cho, Jaeyoung;Burm, Jin Sik
    • Archives of Plastic Surgery
    • /
    • v.48 no.1
    • /
    • pp.69-74
    • /
    • 2021
  • Background In inferomedially rotated zygomatic fractures sticking in the maxillary sinus, it is often difficult to achieve complete reduction only by conventional intraoral reduction. We present a new intraoral reduction technique using a Kirschner wire and its clinical outcome. Methods Among 39 inferomedially impacted zygomatic fractures incompletely reduced by a simple intraoral reduction trial with a bone elevator, a Kirschner wire (1.5 mm) was vertically inserted from the zygomatic body to the lateral orbital rim in 17 inferior-dominant rotation fractures and horizontally inserted to the zygomatic arch in nine medial-dominant and 13 bidirectional rotation fractures. A Kirschner wire was held with a wire holder and lifted in the superolateral or anterolateral direction for reduction. Following reduction of the zygomaticomaxillary fracture, internal fixation was performed. Results Fractures were completely reduced using only an intraoral approach with Kirschner wire reduction in 33 cases and through an additional lower lid or transconjunctival incision in six cases. There were no surgical complications except in one patient with undercorrection. Postoperative 6-month computed tomography scans showed complete bone union and excellent bone alignment. Four patients experienced difficulty with upper lip elevation; however, these problems spontaneously resolved after manual tissue lump massage and intralesional steroid (Triamcinolone) injection. Conclusions We completely reduced infraorbital rim fractures, zygomaticomaxillary buttresses, and zygomaticofrontal suture fractures in 84% of patients through an intraoral approach alone. Intraoral Kirschner wire reduction may be a useful option by which to obtain effective and powerful reduction motion of an inferomedially rotated zygomatic body.

Magnetospheric and ionospheric responses to the passage of solar wind discontinuity on 24 November 2008

  • Kim, Khan-Hyuk;Park, Jong-Sun;Lee, Dong-Hun;Park, Young-Deuk;Angelopoulos, V.;Nishitani, N.;Hori, T.;Shiokawa, K.;Yumoto, K.;Baishev, D.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.91-91
    • /
    • 2011
  • The passage of the interplanetary discontinuity (i.e., sudden increases in the solar wind speed, density, and IMF strength) was detected by ACE near GSE (x, y, z) ~ (222, -36, 3) Re upstream of Earth around 22:48 UT on November 24, 2008. About 55 min later, this solar wind discontinuity was observed by Geotail near GSE (x, y, z) ~ (23, 18, -7) Re in front of Earth's bow shock. From the propagation time of the solar wind discontinuity between ACE and Geotail, it is expected that the discontinuity front is aligned with the Parker spiral and strikes the postnoon dayside magnetopause first. Using coordinated multi-point measurements (THEMIS and GOES) at or in geosynchronous orbit, we observed a tailward propagating sudden impulse (SI), excited by the interplanetary discontinuity, around 23:50 UT with its front retaining alignment similar to that of solar wind discontinuity. The SI event appears a negative-then-positive variation in the H component at high latitude Chokurdakh (CHD: MLAT ~ 64.7 deg) in the prenoon sector, which is opposite sense of normal SI event. During the positive deflection at CHD, the SuperDARN Hokkaido radar detected the downward motion of the ionosphere, implying westward electric field enhancement, at subauroral latitudes near CHD meridian. In our study we will discuss magnetospheric and ionospheric responses to the passage of the solar wind discontinuity using multi-point observations in space and on the ground.

  • PDF

A Therapeutic Approach Based on Motor Development in Congenital Muscular Torticollis: A Case Report (선천성 근육 사경 환아에 대한 운동 발달적 치료 접근: 증례보고)

  • Ryu, Je-Yong;Kim, Yu-Jin;Sung, Ju-Yeon;Shim, Jae-Hun;Lee, Gyu-Wan;Oh, Duck-Won
    • Physical Therapy Korea
    • /
    • v.13 no.2
    • /
    • pp.77-84
    • /
    • 2006
  • Although conservative management of congenital muscular torticollis (CMT) has been well documented, relatively little is known about the response to the treatment. The purposes of this case report were to describe the use of a therapeutic approach based on motor development in physical therapy intervention for an infant with CMT and to report the result of the treatment. The patient was a 20-day-old baby boy with left CMT presenting muscular mass in the left sternocleidomastoid muscle. The angle of the lateral head tilt was 20 degrees. The size of muscular mass was 5.3 mm in ultrasonography. Intervention included ultrasonic therapy, soft tissue massage, passive and active range of motion exercises, motor developmental therapy, and parent instruction. The procedures of motor developmental therapy and changes in the amount of lateral head tilt were documented using photography. The size of the mass was decreased to .3 mm before the 5-month follow-up. The patient also maintained a midline head position in the supine position and a midline head alignment during all functional activities. A therapeutic approach based on motor development is a beneficial method for reducing an asymmetrical head and neck position, and facilitating normal development as a component of physical therapy intervention.

  • PDF

Immediate Effects of the Downhill Treadmill Walking Exercise on Thoracic Angle and Thoracic Extensor Muscle Activity in Subjects With Thoracic Kyphosis (내리막 경사로 트레드밀 걷기 훈련이 흉추 뒤굽음증의 흉추각도와 흉추기립근 활성도에 미치는 영향)

  • Lee, Jun-hyeok;Jeon, Hye-seon;Kim, Ji-hyun;Park, Joo-hee;Yoon, Hyeo-bin
    • Physical Therapy Korea
    • /
    • v.26 no.2
    • /
    • pp.1-7
    • /
    • 2019
  • Background: In previous studies, changes in postural alignment were found when the slope was changed during walking. Downhill walking straightens the trunk by shifting the line of gravity backward. Objects: This study investigated the effect of the downhill treadmill walking exercise (DTWE) on thoracic angle and thoracic erector spinae (TES) activation in subjects with thoracic kyphosis. Methods: A total of 20 subjects with thoracic kyphosis were recruited for this study. All the subjects performed the DTWE for 30 minutes. A surface EMG and 3D motion capture system were used to measure TES activation and thoracic angle before and after the DTWE. Paired t-tests were used to confirm the effect of the DTWE (p<.05). Results: Both the thoracic angle and TES activation had significantly increased after the DTWE compared to the baseline (p<.05). An increase in the thoracic angle indicates a decrease in kyphosis. Conclusion: The DTWE is effective for thoracic kyphosis patients as it decreases their kyphotic posture and increases the TES activation. Future longitudinal studies are required to investigate the long-term effects of the DTWE.

Immediate Effects of High-Frequency Diathermy on Neck, Shoulder Alignment, Pain and Function in Adults with Forward Head Posture (고주파심부투열 치료가 앞쪽머리자세를 가진 성인의 자세정렬, 통증 그리고 기능에 미치는 즉각적인 효과)

  • Young-Joo Cha;Kyoung-Tae Kim
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.3
    • /
    • pp.143-153
    • /
    • 2024
  • Purpose : Forward head posture (FHP), characterized by the anterior positioning of the head relative to the spine, is a common postural deviation that can lead to neck pain, reduced mobility, and muscle imbalances. Recently, high-frequency deep heat therapy (HFDT) has been gaining attention for the intervention of FHP. This research aims to investigate the efficacy of HFDT in comparison to instrument assisted soft-tissue mobilization (IASTM) for treating FHP among 30 young adults. Methods : Participants were randomly assigned to either the HFDT or IASTM group. The study focused on examining changes in neck joint mobility, pain thresholds, rounded shoulder distance, lower trapezius muscle strength, and neck dysfunction. Measurements were taken before and after the interventions. Paired t-tests were used for within-group analyses, and independent t-tests were employed for between-group comparisons. The statistical significance level α was set to .05. Results : Statistically significant improvements were observed across all measured parameters in both groups (p<.05). The HFDT group showed significantly greater enhancements in neck joint mobility, pain thresholds, rounded shoulder distance, lower trapezius muscle strength, and neck dysfunction parameters. Specifically, HFDT was more effective than IASTM in improving neck joint mobility, right upper trapezius pain threshold, left rounded shoulder distance, and right lower trapezius strength. The only exceptions were neck flexion range of motion, left upper trapezius pain threshold, right rounded shoulder distance, and left lower trapezius strength, where no significant differences were found between the groups. Conclusion : The findings suggest that HFDT, by combining the benefits of high-frequency therapy and manual therapy, effectively alleviates upper trapezius muscle pain and tension, enhances neck mobility, and strengthens lower trapezius muscles. Thus, HFDT could be considered a valuable intervention for clinicians aiming to address FHP and associated musculoskeletal problems.

Speech Animation Synthesis based on a Korean Co-articulation Model (한국어 동시조음 모델에 기반한 스피치 애니메이션 생성)

  • Jang, Minjung;Jung, Sunjin;Noh, Junyong
    • Journal of the Korea Computer Graphics Society
    • /
    • v.26 no.3
    • /
    • pp.49-59
    • /
    • 2020
  • In this paper, we propose a speech animation synthesis specialized in Korean through a rule-based co-articulation model. Speech animation has been widely used in the cultural industry, such as movies, animations, and games that require natural and realistic motion. Because the technique for audio driven speech animation has been mainly developed for English, however, the animation results for domestic content are often visually very unnatural. For example, dubbing of a voice actor is played with no mouth motion at all or with an unsynchronized looping of simple mouth shapes at best. Although there are language-independent speech animation models, which are not specialized in Korean, they are yet to ensure the quality to be utilized in a domestic content production. Therefore, we propose a natural speech animation synthesis method that reflects the linguistic characteristics of Korean driven by an input audio and text. Reflecting the features that vowels mostly determine the mouth shape in Korean, a coarticulation model separating lips and the tongue has been defined to solve the previous problem of lip distortion and occasional missing of some phoneme characteristics. Our model also reflects the differences in prosodic features for improved dynamics in speech animation. Through user studies, we verify that the proposed model can synthesize natural speech animation.

RETRIEVAL OF LOCAL INTERPLANETARY DUST EMISSIVITY BY ASTRO-F

  • HONG S. S.;KWON S. M.;PYO J.;UENO M.;ISHIGURO M.;USUI F.;WEINBERG J. L.
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.4
    • /
    • pp.159-169
    • /
    • 2004
  • This is a proposal to probe local part of the interplanetary dust (IPD) cloud complex and retrieve mean volume emissivity of the local IPDs at mid-infrared wavelengths. This will be done by monitoring, with Infrared Camera (IRC) aboard the ASTRO-F, the annual modulation of the zodiacal emission. In pointing mode of the ASTRO-F mission the spacecraft can make attitude maneuvering over approximately ${\pm}1^{\circ}$ range centered at solar elongation $90^{\circ}$ in the ecliptic plane. The attitude maneuvering combined with high sensitivity of the IRC will provide us with a unique opportunity observationally to take derivatives of the zodiacal emission brightness with respect to the solar elongation. From the resulting differential of the brightness over the ${\pm}1^{\circ}$ range, one can directly determine the mean volume emissivity of the local IPDs with a sufficient accuracy to de-modulate the annual emissivity variations due to the Earth's elliptical motion and the dis-alignment of the maximum IPD density plane with respect to the ecliptic. The non-zero eccentricity ($e_{\oplus}$= 0.0167) of the Earth's orbit combined with the sensitive temperature dependence of the Planck function would bring modulations of amplitude at least $3.34\%$ to the zodiacal emission brightness at mid-infrared wavelengths, with which one may determine the IPD temperature T(r) and mean number density n(r) as functions of heliocentric distance r. This will in turn fix the power-law exponent $\delta$ in the relation $T(r) = T_o(r/r_o)^{-\delta}$ for the dust temperature and v in $n(r) = n_o(r/r_o)^-v$ for the density. We discuss how one may de-couple the notorious degeneracy of cross-section, density, reference temperature $T_o$ and exponent $\delta$.

Verification of X-sight Lung Tracking System in the CyberKnife (사이버나이프에서 폐종양 추적 시스템의 정확도 분석)

  • Huh, Hyun-Do;Choi, Sang-Hyoun;Kim, Woo-Chul;Kim, Hun-Jeong;Kim, Seong-Hoon;Cho, Sam-Ju;Min, Chul-Ki;Cho, Kwang-Hwan;Lee, Sang-Hoon;Choi, Jin-Ho;Lim, Sang-Wook;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.174-179
    • /
    • 2009
  • To track moving tumor in real time, CyberKnife system imports a technique of the synchrony respiratory tracking system. The fiducial marker which are detectable in X-ray images were demand in CyberKnife Robotic radiosurgery system. It issued as reference markers to locate and track tumor location during patient alignment and treatment delivery. Fiducial marker implantation is an invasive surgical operation that carries a relatively high risk of pneumothorax. Most recently, it was developed a direct lung tumor registration method that does not require the use of fiducials. The purpose of this study is to measure the accuracy of target applying X-sight lung tracking using the Gafchromic film in dynamic moving thorax phantom. The X-sight Lung Tracking quality assurance motion phantom simulates simple respiratory motion of a lung tumor and provides Gafchromic dosimetry film-based test capability at locations inside the phantom corresponding to a typical lung tumor. The total average error for the X-sight Lung Tracking System with a moving target was $0.85{\pm}0.22$ mm. The results were considered reliable and applicable for lung tumor treatment in CyberKnife radiosurgery system. Clinically, breathing patterns of patients may vary during radiation therapy. Therefore, additional studies with a set real patient data are necessary to evaluate the target accuracy for the X-sight Lung Tracking system.

  • PDF

Application of a Heat Pack and Soft Tissue Mobilization on Hamstring Muscle of Flexibility in Subjects with Cerebral Palsy (온습포와 연부조직 가동술이 뇌성마비의 슬괵근 유연성 증가에 미치는 영향)

  • Ro, Hyo-Lyun;Lee, Dae-Hee;Kang, Dong-Yeon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.4 no.3
    • /
    • pp.149-156
    • /
    • 2009
  • Purpose:The hamstring muscle has an important role in standing, walking and other functions related to daily living. Most people with Cerebral Palsy(CP) have muscle tightness, especially in the hamstring, which may cause abnormal alignment in the lower extremities. To investigate an effective treatment for hamstring muscle tightness by observing the effects of heat pack or Soft tissue mobilization(STM) on hamstring muscles. Methods:Thirteen-two volunteers with CP aged between 9 and 13 years($M\pmSD$: $11\pm1.46$), were recruited and divided into four groups of four: (1) the STM for people with Spastic CP group, (2) the heat pack(HP) for people with Spastic CP group, (3) the STM for people with Mixd CP group, and (4) the heat pack for people with Mixed CP group. All received treatment three times per week for six weeks. A inclinometer was used to measure for hip flexion & knee extension joint range motion(ROM). Results:The ROM of hip flexion & knee extension were improved at the STM and HP for people with Spastic CP groups. The ROM and hip flexion were improved at the STM and HP for people with Mixed CP groups. The amount of increase ROM are differenced by the types of CP. Conculusion:STM and heat pack, both are effective for people with CP especially for Spastic CP.

  • PDF

Performance Test of Isolator for Reaction Wheel Micro-Vibration (인공위성 반작용휠 미소진동 감쇠기의 성능 측정)

  • Oh, Shi-Hwan;Seo, Hyun-Ho;Yim, Jo-Ryeong;Rhee, Seung-Wu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.376-379
    • /
    • 2006
  • Reaction Wheel Assembly (RWA) is one of the major disturbance sources that have influence upon the Line of Sight (LOS) of payload. A micro-vibration induced by RWA is propagated through the satellite structure and decrease the LOS stability performance of payload. This effect shall be analyzed through the jitter analysis. If a requirement or specification of payload jitter level is found to be not satisfied according to the jitter analysis campaign, some modification or redesign should be done on the satellite structure or a couple of isolator should be attached on the RWA interface in order to reduce the transmitted vibration level of RWA. The purpose of ???RWA isolator test? is to roughly evaluate the performance of vibration suppression level with a passive RWA isolator made of rubber. For this test, actual RWA is used as a vibration source and a couple of cube-shaped rubber mount designed for satellite is used as a passive isolator. There may be several considerations in order to accommodate RWA isolator to spacecraft such as not only vibration reduction performance but also thermal conduction problem, mechanical size, RWA alignment problem, etc. But in this report the feasibility of RWA isolator is analyzed only in a vibration suppression point of view. As a result, high frequency vibration of RWA above 50Hz is perfectly attenuated with isolators, however, first harmonic components below 50Hz became larger due to the additional low frequency resonance modes of roll, pitch, yaw rigid body motion of RWA+bracket.

  • PDF