• 제목/요약/키워드: Impulse equipment

검색결과 86건 처리시간 0.023초

Dynamic Analysis of Sliders in Optical Memory System

  • Gyeong Hwa, Im;Chae Heon, An
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2003년도 추계학술대회 발표 논문집
    • /
    • pp.200-206
    • /
    • 2003
  • Identification method is formulated to evaluate the dynamic characteristics of air bearings under NFR (Near Field Recording) sliders. Using dynamic analysis, impulse responses and frequency response functions of NFR sliders are obtained on numerical non-linear models including rigid motion of slider and fluid motion of air bearing under the slider. System parameters are identified by modal analysis method and instrumental variable method. The identified system parameters of sliders are utilized to evaluate the dynamic characteristics of air bearings.

  • PDF

발사환경에 대한 인공위성 전장품의 구조진동 해석 (Structural Vibration Analysis of Electronic Equipment for Satellite under Launch Environments)

  • 박태원;정일호;한상원;김성훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.768-771
    • /
    • 2003
  • The impulse between launch vehicle and atmosphere can generate a lot of noise and vibration during the process of launching a satellite. Structurally, electronic equipment (KOMPSAT 2, RDU : Remote Drive Unit) of a satellite consists of aluminum case containing PCB (Printed circuit boards). Each PCB has resistors and IC (Integrated circuits). Noise and vibration of wide frequency band are transferred to the inside of fairing, subsequently creating vibration of the electronic equipment of the satellite. In this situation. random vibration can cause malfunctioning of the electronic equipment of the device. Furthermore, when tile frequency of random vibration meets with natural frequency of PCB. fatigue fracture nay occur in the part of solder joint. The launching environment, thus. needs to be carefully considered when designing the electronic equipment of a satellite. In general. the safety of the electronic equipment is supposed to be related to the natural frequency, shapes of mode and dynamic deflection of PCB in the electronic equipment. Structural vibration analysis of PCB and its electronic components can be performed using either FEM(Finite Element Method) or vibration test. In this study. the natural frequency and dynamic deflection of PCB are measured by FEM, aud the safety of the electronic components of PCB is being evaluated according to the results. This study presents a unique method for finite element modeling and analysis of PCB and its electronic components. The results of FEA are verified by vibration test. The method proposed herein may be applicable to various designs from the electronic equipments of a satellite to home electronics.

  • PDF

건조 선박 배관 내의 새로운 유세정 시스템에 관한 연구 (A Study on a Novel Pipe Flushing System within Dry Dock Ship Pipelines)

  • 노진철;김민식;손영득
    • 해양환경안전학회지
    • /
    • 제30권2호
    • /
    • pp.233-238
    • /
    • 2024
  • 배관 세정 공정은 조선소 선박 건조과정에서 배관 설치 후 장비를 시운전하는 단계로 넘어가기 전에 최종적으로 배관 내부의 이물질을 제거하는 매우 중요한 공정이다. 만약에 배관 내에 이물질이 있는 상태에서 장비를 시운전하는 단계로 넘어갈 경우 이물질이 고가의 장비에 유입되어 펌프 및 기어, 베어링 등이 파손되는 요인이 된다. 특히 펌프나 유압 밸브 같은 경우는 아주 작은 이물질이라도 장비 속으로 유입이 되면 대형 사고로 이어지며, 이런 장비 사고는 주변에 장비 운전을 하는 작업자의 인명사고까지 연계되어 중대 재해의 잠재 원인이 되므로 조선소 고객인 선주들도 매우 집중적으로 확인하고 관리하는 공정이다. 이러한 문제점을 해결하기 위해 본 연구에서 기존의 배관 세정 공법에서 유세정 효과를 증가시킬 수 있도록 배관 내 세정 유체의 흐름을 증가할 수 있는 시스템을 제안한다.

Application of Digital Signal Analysis Technique to Enhance the Quality of Tracer Gas Measurements in IAQ Model Tests

  • Lee, Hee-Kwan;Awbi, Hazim B.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제23권E2호
    • /
    • pp.66-73
    • /
    • 2007
  • The introduction of tracer gas techniques to ventilation studies in indoor environments provides valuable information that used to be unattainable from conventional testing environments. Data acquisition systems (DASs) containing analogue-to-digital (A/D) converters are usually used to function the key role that records signals to storage in digital format. In the testing process, there exist a number of components in the measuring equipment which may produce system-based inference to the monitored results. These unwanted fluctuations may cause significant error in data analysis, especially when non-linear algorithms are involved. In this study, a pre-processor is developed and applied to separate the unwanted fluctuations (noise or interference) in raw measurements and to reduce the uncertainty in the measurement. Moving average, notch filter, FIR (Finite Impulse Response) filters, and IIR (Infinite Impulse Response) filters are designed and applied to collect the desired information from the raw measurements. Tracer gas concentrations are monitored during leakage and ventilation tests in the model test room. The signal analysis functions are introduced to carry out the digital signal processing (DSP) work. Overall the FIR filters process the $CO_2$ measurement properly for ventilation rate and mean age of air calculations. It is found that, the Kaiser filter was the most applicable digital filter for pre-processing the tracer gas measurements. Although the IIR filters help to reduce the random noise in the data, they cause considerable changes to the filtered data, which is not desirable.

전원용 SPD의 건전성 평가 장치 개발 (Development of Integrity Evaluation Instrument for the Power Line Surge Protective Device)

  • 장석훈;김영진;김성주;김재형
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.39-45
    • /
    • 2015
  • This paper deals with development of integrity evaluation instrument for the power line surge protective device. A reliable power supply is an essential element in the developed information and communication society by highly advances in IT technology. However, the lightning incidence also increased with the recent extreme weather events. In Korea, in order to protect the electrical system from lightning surge, SPD(Surge Protective Device) has been used for these past 30 years. However, the method of diagnosing the safety of the SPD in the industry is insufficient. In this paper, SPD integrity evaluation system was composed of a variable DC power source unit, voltage-current sensor and the embedded controller. In order to measure V-I characteristics of MOV, 3 type samples were degraded by impulse current generator. After impulse tests, the varistor voltage of all samples and nonlinearity coefficient were decreased. It confirmed the utility of the developed equipment by this experimental test and the reliability of SPD is expected for surge accident prevention when applied to industrial plant.

충격파-부분방전(SI-PD) 시험방법을 이용한 케이블 진단에 관한 기초 연구 (A Possible diagnostic method of cable system using SI-PD measurement)

  • 김정태;구자윤;장은;조연옥;김상준;송일근;김주용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1774-1777
    • /
    • 1996
  • In this paper, applicability of SI-PD(switching impulse - partial discharge) testing method was put on an attempt as a newly proposed diagnostic method for the underground distribution power cable system in Korea. For this purpose, SI-PD testing equipment was designed, and tests were performed using artificial needle-type defects integrated into the 22.9 kV CN/CV cables in drder to prove its reliability. As a result, arc noises, generated from spark gap, were considerably decreased by use of a pneumatic switch immersed into oil, and artificial needle-type defects were well detected with impulse voltage level under $2U_0$. These results imply that it is likely possible to apply SI-PD measurement method as a the nondistructive test for the 22.9 kV CN/CV cable system in Korea.

  • PDF

CCD카메라를 이용한 생물감시장치의 독성자료 신뢰성 향상에 관한 연구 (Study on Improving Reliability of Biomonitor by Using CCD Camera)

  • 김현창;김영석
    • 대한기계학회논문집A
    • /
    • 제34권10호
    • /
    • pp.1351-1357
    • /
    • 2010
  • 우리나라 주요하천의 수질오염감시를 목적으로 물벼룩을 이용한 생물감시장치가 설치, 운용되고 있다. 기기 목적상 유해물질에 대해 신뢰성 있는 신속한 독성경보를 내릴 수 있어야 하고, 무인원격측정기기이므로 계절별, 연간 하천의 물리적인 변화에도 측정의 신뢰성이 확보되어야 한다. 국내에 운영중인 장비는 물벼룩의 단위시간당 뛰는 횟수(Impulse)를 측정하는 방법과 유영형태를 분석하여 독성지수(Toxicity)로 나타내는 방법이 있다. 두 장비가 동일한 조건에서 운전되었음에도 가동률과 긴급점검횟수가 다르게 나타났으며 원인은 용기 내 기포발생과 압력차이 등 여러 가지가 있다. 본 연구의 목적은 기포와 미시적인 압력의 영향을 감소시켜 측정의 불확실성을 줄이는 것이고, 나아가 생물감시장치가 어떤 환경에 설치되더라도 수질오염감시의 목적을 정상적으로 달성하는 데 기여하는 것이다.

뇌임펄스전압에 대한 돌침형 피뢰침의 주수섬락특성과 개선 방안 (Wet Flashover Characteristics and Reform Measure of a Conventional Lightning Rod against Lightning Impulse Voltages)

  • 이복희;강석만;엄주홍;이승칠;김승지
    • 조명전기설비학회논문지
    • /
    • 제16권3호
    • /
    • pp.93-100
    • /
    • 2002
  • 본 논문에서는 피뢰설비에 대한 국내 규격의 재정립을 위해 관련된 기술을 검증할 목적으로 낙뢰로부터의 건축물 보호에 대한 규정과 기술상의 지침 등을 검토하였고, 국내의 피뢰설비에 관한 규격의 몇 가지 문제점을 해결하기 위란 연구를 수행하였다. 기존의 피뢰침에 대하여 피임펄스시험을 수행한 결과, 비교적 낮은 임펄스 전압에서 피뢰침 수뢰부의 절연체 표면에서 섬락을 일으켰고, 피격전류의 대부분은 피뢰침 지지용 금속판을 통하여 홀렀다. 따라서 피뢰침 지지대 부근에서의 전위경도는 매우 높게 상승하게 되어 피뢰설비로서의 기능을 못하게된다. 피뢰침 절연물의 섬락은 초소형 전자기기의 오동작을 비롯하여 감전이나 전기설비의 파손과 같은 막대한 경제적 손실을 가져오게 된다.

랜덤 임펄스 잡음을 제거하기 위한 가중치 스위칭 필터를 이용한 영상 복원 알고리즘 (Image Restoration Algorithm using Weighted Switching Filter for Remove Random-Valued Impulse Noise)

  • 천봉원;김남호
    • 한국정보통신학회논문지
    • /
    • 제24권5호
    • /
    • pp.609-615
    • /
    • 2020
  • 현대 사회는 4차 산업 혁명과 더불어 디지털 장비의 사용이 증가하여 영상 및 신호처리의 중요성이 높아지고 있으며, 이와 함께 잡음 제거에 관한 연구가 활발하게 이루어지고 있다. 본 논문은 랜덤 임펄스 잡음 제거를 위한 스위칭 필터 알고리즘을 제안한다. 제안한 알고리즘은 영상에 존재하는 잡음 수준을 판단하여 임계값을 구하며, 임계값은 입력 화소값과 기준치의 차이와 비교되어 필터의 가중치 스위칭 과정에 사용한다. 필터의 최종 출력은 스위칭에 따라 화소 가중치 및 변형된 가중치 메디안 필터를 적용하여 추정치를 구하며, 추정치와 입력 화소값을 비교하여 최종 출력을 구한다. 제안한 알고리즘의 성능을 평가하기 위해 시뮬레이션 및 PSNR 등을 이용하여 기존 방법들과 비교하였다.

서지 보호기의 열화 특성과 온라인 진단장치 (Deterioration Characteristics and an On-Line Diagnostic Equipment for Surge Protective Devices)

  • 박경수;왕국명;황성철;김선재;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제29권10호
    • /
    • pp.635-640
    • /
    • 2016
  • This paper dealt with the deterioration characteristics and an on-line diagnosis equipment for SPDs (surge protective devices). An accelerated aging test was carried out using a $8/20{\mu}s$ standard lightning impulse current to analyze the changes of electrical characteristics and to propose the diagnostic parameters and the criterion for deterioration of ZnO varistor which is the core component of SPDs. Based on the experimental results, an on-line diagnosis equipment for SPD was fabricated, which can measure the total leakage current, reference and clamping voltage. The leakage current measurement circuit was designed using a low-noise amplifier and a clamp type ZCT. A linear controller, the leakage current measurement part and a HVDC were used in the measurement of reference voltage. The measurement circuit of clamping voltage consisted of a surge generator and a coupling circuit. In a calibration process, measurement error of the prototype equipment was less than 3%.