• Title/Summary/Keyword: Impulse Test

Search Result 721, Processing Time 0.025 seconds

A Study on Procedures of the Accelerated Life Testing for Hose Assemblies (플라스틱 호스 조립체의 가속수명시험 방법에 대한 연구)

  • Lee, Yong-Beom;Kim, Hyeong-Ui;Kim, Jong-Gi;Park, Jong-Ho
    • 연구논문집
    • /
    • s.34
    • /
    • pp.79-85
    • /
    • 2004
  • There are several types of life test method for hose assemblies. The two major tests used for hose assemblies are impulse test and burst test. And magnification adjustment of impulse pressure, heating of testing oil and repetitive motions of bending and straightening of testing hose are also performed for accelerating the life. According to the manufacture process of hose and swaging process of fitting, there is a difference in the life of hose assemblies from minimum 7 times to maximum 40 times during the life test in the same functioning condition. Like this, the life test of hose which has a wide scope of life distribution gives a problem that observation should take a long time to find out the existence of the bursting from the beginning of the test to the completion of bursting of hose assemblies. Therefore, this research proposes a process of concentrating on the defective section of hose assemblies and maximizing the life acceleration by giving 'Knockdown stress' to hose assemblies just until before the hose assemblies get out of order.

  • PDF

Effects of Entertainment Service on Impulse Buying Behavior of Apparels -Comparing with Department Stores and Shopping Malls- (엔터테인먼트서비스가 의복충동구매행동에 미치는 영향 -백화점과 쇼핑몰을 중심으로-)

  • Park, Eun-Joo;Park, Jung-Shin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.9_10 s.157
    • /
    • pp.1333-1343
    • /
    • 2006
  • Consumers seek the pleasure, fun and satisfaction in shopping. Retailing environments of apparel products are rapidly changing than ever before. One of there changes are offered apparel products with entertainment service, such as theaters, restaurants and so on. The purpose of this study was to investigate the effects of entertainment service, shopping orientation and emotion on impulse buying behavior in department stores an shopping malls. A self-administrated questionaire was developed based on the results of previous researches and pre-test. Data were obtained from shoppers(N=684) randomly selected in department stores and shopping malls located in Seoul and Busan. Data were analyzed by factor analysis, t-test, cross analysis, and path analysis. The results showed that; impulse buying behavior was directly or indirectly affected by shopping orientation in both of two store types. In department stores, consumers were affected to make a good mood by entertainment service while, in the shopping malls, consumers were influenced directly by entertainment service to be a good mood and to purchase impulsively apparel products. Therefore, the impulse buying behavior was influenced differently by entertainment service in store types. From the retailer's perspective, they give insights into the development of strategies utilized to marketing planning of entertainment service in each store types.

Experimental Investigation of the Effect of Partial Admission Ratio on the Performance of Supersonic Impulse Turbine (초음속 충동형 축류터빈의 부분분사비 효과에 대한 실험적 연구)

  • Jeong, Eun-Hwan;Park, Pyun-Goo;Kim, Jin-Han
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.4
    • /
    • pp.59-66
    • /
    • 2007
  • In this paper, experimental investigation results of the effect of partial admission ratio on the performance of axial turbine was presented. A supersonic impulse turbine of gas generator cycle liquid rocket engine turbopump was used for the test. for experimental purpose, a nozzle block, in which total 14 number of axi-symmetric convergent-divergent nozzles are arranged circumferentially, was designed and manufactured. Partial admission ratio was controlled by changing the number of active nozzles. High pressure air was used as working medium for the test. The experimental result revealed that the performance of the supersonic impulse turbine does not much affected by the partial admission ratio for supersonic impulse turbine.

The Influences of Shopping Orientation and Impulse Buying Orientation on Internet Shopping Addiction to Fashion Products (소비자의 쇼핑성향과 충동구매성향이 인터넷 패션제품 쇼핑중독에 미치는 영향)

  • Ji, Hye-Kyung
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.15 no.2
    • /
    • pp.27-41
    • /
    • 2013
  • The purpose of this study is to find out the influences of consumers' shopping orientation and impulse buying orientation on shopping addiction to fashion products in the internet shopping malls. This study surveyed 521 male and female consumers in their 20s~40s in August 2012 who have purchased fashion products through internet shopping malls. For statistical analysis, descriptive statistics, reliability analysis, $x^2$-test, factor analysis, ANOVA analysis, Duncan test, and regression analysis were carried out using SPSS for Windows 12.0. The results are as follows. First, it was identified that there were not significant differences in consumers' demographic characteristics according to the level of internet shopping addiction consumer groups. Second, high level shopping addiction consumers were higher in pleasure/convenience seeking, fashion seeking, and brand seeking shopping orientations and in refreshing, non-plan shopping, recommendation from acquaintances, product stimulus, purchaser stimulus, sales promotion stimulus impulse buying orientations than low level consumers. Third, internet shopping addiction was significantly influenced by the pleasure/convenience, fashion, economic efficiency, brand, sale seeking shopping orientations and refreshing, non-plan shopping, sales promotion stimulus impulse buying orientations. The results of this study will help internet fashion enterprises to handle the consumers with shopping addiction as well as the consumers with high shopping addiction to be able to manage their shopping addiction themselves.

  • PDF

Solid Core Suspension Disc Insulators Preventing Puncture Caused by Steep Front Surge Voltage

  • Sangkasaad, Samruay
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.5
    • /
    • pp.165-170
    • /
    • 2003
  • This paper presents development of solid core suspension disc insulators (cap and cap suspension disc insulator) for replacing cap and pin suspension disc insulators in overhead transmission and distribution lines which expose to lightning discharges. By this means the punctured problem caused by steep front surge voltage created by lightning discharge on the lines can be solved. The solid core suspension insulator was designed and constructed based on the dimensions of conventional suspension disc insulators (cap and pin insulators). The insulators are made of alumina porcelain. The electrical and mechanical characteristics of the solid core suspension insulators were carried out. The puncture test was performed in the air by applying steep front impulse voltage with amplitude about 2.5 per unit of 50% flashover (CFO) of the insulator unit at negative standard lightning impulse $1.2/50\;\mu\textrm{s}$ with steepness up to $9200\;kV/\mu\textrm{s}$. The testing results show that solid core suspension disc insulators are not punctured eventhough the steepness of the steep front impulse voltage was increased up to $9200\;kV/\mu\textrm{s}$.

A Study on the Compensation Method in the Measuring System for Chopped Lightning Impulse (충격전압 재단과 측정을 위한 보상회로에 관한 연구)

  • Kim, Ik-Soo;Kim, Young-Bae;Kim, Jin-Gi;Kim, Min-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1895-1897
    • /
    • 1996
  • Lightning impulse voltage is essential to evaluate the insulation performance of electric power apparatus. Recently international standard (IEC-60) on high voltage measurement techniques are being revised. In the draft of this standard, a new calibration method is introduced and the accuracy of most industrial measuring systems is maintained by means of comparison test against the reference measuring systems. Comparison tests of dividers for chopped lightning impulse measurement were rallied out by KERI. The 700kV shielded resisitive divider with and without compensation element were done comparison test with 300kV PTB divider which have the similar charateristics as that were circulated among the laboratories. This paper reports on the calculation results of response charateristics obtained by EMTP and the comparison test results with chopped lightning impulse voltages from 150kV to 250kV. It is demonstrated that KERI are capable of realizing the idea in the revision of the IEC standand, that is, to establish traceability.

  • PDF

Dead Operation Characteristics of Earth Leakage Circuit Breaker Caused by Impulse Voltages (임펄스전압에 대한 누전차단기의 부동작 특성)

  • Lee, Bok-Hee;Chang, Sug-Hun;Lee, Seung-Chil
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1715-1717
    • /
    • 1997
  • This paper deals with the dead operation characteristics of the earth leakage circuit breaker(ELB) caused by impulse voltages. The surge protective devices for electronic circuit and AC power lines are becoming more widely used. It is possible to give rise to the malfunction of ELB due to the operation of surge protective devices, and the interruption of AC power lines brings about several disadvantages such as low reliability of electronic and informational systems, economical loss, and etc. The dead operation characteristics of the ELB from impulse voltages were measured under the conditions of KS C 4613 and the test circuit with a varistor. As a result, the peak current value of the zero-phase sequence circuit of the ELB is increased as the surge voltage and stray capacitance increase. All of the ELBs used in this work were satisfied with the lightning impulse dead operation test condition defined in KS C 4613. However one specimen only did not cause dead operation in the condition of the test circuit with a varistor. There is high possibility that a large portion of the ELBs connected with the AC power lines having the surge protective devices bring about the dead operation.

  • PDF

The Influences of Price, Product and Promotion on Clothing Impulse Buying by the Internet Shopping Mall Types (인터넷 쇼핑몰 유형별 의류제품 충동구매에 미치는 가격, 제품, 판촉의 영향)

  • Ji, Hye-Kyung
    • Fashion & Textile Research Journal
    • /
    • v.15 no.4
    • /
    • pp.543-553
    • /
    • 2013
  • This study analyzes the influence of price, product and promotion on clothing impulse buying according to internet shopping mall type. This study conducted a survey of 346 male and female consumers in their 20s-40s who have experienced clothing impulse buying from an internet shopping mall. Respondents were selected using convenience sampling through an online survey conducted in August 2012. For statistical analysis, descriptive statistics, reliability analysis, $X^2$-test, factor analysis, and regression analysis where carried out using SPSS for Windows 12.0. The results were as follows. First, there were significant differences for consumer gender, age, marital status, and education on clothing impulse buying according to shopping mall type. Second, there were differences for the influence of each component (price, product and promotion) on clothing impulse buying according to shopping mall type. Third, it was identified that influence of components (price, product and promotion) on clothing impulse buying were in the following order: low price, freshness, prize promotion, scarcity, open market price discount, prize promotion, freshness, fashionability, low price in general shopping malls, payment term benefit, freshness, and scarcity in fashion SOHO shopping malls. This study provides information for consumer management and promotion strategies according to each shopping mall type by understanding clothing impulse buying by consumers and factors according to shopping mall type.

Adaptive Switching Median Filter for Impulse Noise Removal Based on Support Vector Machines

  • Lee, Dae-Geun;Park, Min-Jae;Kim, Jeong-Ok;Kim, Do-Yoon;Kim, Dong-Wook;Lim, Dong-Hoon
    • Communications for Statistical Applications and Methods
    • /
    • v.18 no.6
    • /
    • pp.871-886
    • /
    • 2011
  • This paper proposes a powerful SVM-ASM filter, the adaptive switching median(ASM) filter based on support vector machines(SVMs), to effectively reduce impulse noise in corrupted images while preserving image details and features. The proposed SVM-ASM filter is composed of two stages: SVM impulse detection and ASM filtering. SVM impulse detection determines whether the pixels are corrupted by noise or not according to an optimal discrimination function. ASM filtering implements the image filtering with a variable window size to effectively remove the noisy pixels determined by the SVM impulse detection. Experimental results show that the SVM-ASM filter performs significantly better than many other existing filters for denoising impulse noise even in highly corrupted images with regard to noise suppression and detail preservation. The SVM-ASM filter is also extremely robust with respect to various test images and various percentages of image noise.

V-t Characteristics in $SF_6-N_2$ Mixtures for Transient Impulse Voltages ($SF_6-N_2$ 혼합가스에서 과도임펄스전압에 대한 V-t특성)

  • Lee, Bok-Hui;Lee, Gyeong-Ok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.9
    • /
    • pp.456-465
    • /
    • 2001
  • In this paper, breakdown voltages in $SF_6-N_2$ mixtures were experimentally investigated to understand characteristics of dielectric strength and physical phenomena in nonuniform field disturbed by a needle shape protrusion. The test voltages are the lightning impulse$(\pm1.2/44 \mus)$ and the damped oscillatory impulse$(\pm400 ns / 0.83 MHz)$ voltages which can be occurred by the operation of disconnecting switches in gas-insulated switchgears(GIS). The effects of the polarity and wave shape of the test voltages, and the gas pressure on the V-t characteristics were in detail examined. The V-t characteristic curves were measured in different two ways : (1) one is the method by taking the maximum voltage recorded at or prior to breakdown against the time to breakdown, that is, the Procedures recommended in IEC 60060-1, (2) the other is the method by taking the voltage at the instant of chopping against the time to breakdown. As a result, the V-t characteristics of $SF_6-N_2$ mixtures in nonuniform electric field were significantly affected by the polarity and wave shape of the applied voltages. The positive breakdown voltages resulted in lower breakdown voltages in the time ranges considered, and the V-t curves for the negative oscillatory impulse voltage were extended over the longer time range. For the lightning impulse voltages, the V-t curves obtained by IEC Pub. 60060-1 were nearly same with the V-t curves obtained by the voltage at the instant of chopping against the time to breakdown. It is clear that the actual breakdown voltages were much lower than the maximum voltages appearing at or prior to breakdown because of the displacement current produced as a result of the dV/dt during the oscillatory transient voltage app1ication. The scattering of the negative actual breakdown voltages was much larger than that of the positive.

  • PDF