• Title/Summary/Keyword: Improving Efficiency

Search Result 3,189, Processing Time 0.036 seconds

IPMSM Vector Control using MPC5554 for HEV (MPC5554를 이용한 HEV용 IPMSM 벡터제어)

  • Moon, Jung-Song;Lee, Jung-Hyo;Ha, In-Yong;Won, Chung-Yuen
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.213-219
    • /
    • 2010
  • MCU(Micro Controller Unit) used for the automobiles has been required for improving of the safety and high reliability. Also, the necessity of high performance MCU equipped with high fuel-efficiency has been risen according to increased requests of high fuel-efficiency and improving the occupants safety with the development of intelligent vehicles and future vehicles. The MPC5554 32-bit embedded controller, made by Freescale Semiconductor, specialized in the part of the power train provides the high reliability, fast interrupt process and real-time control. In This paper, the investigation on IPMSM using MPC5554 has been performed. Also SVPWM(Space Vector Pulse Width Modulation) is implemented to the servo system.

  • PDF

Development of Automatic Data Acquisition & Remote Diagnostic System for Improving Efficiency of High-Voltage Motors Off-Line Insulation Diagnostic Test (고압전동기 Off-Line 절연진단시험 효율개선을 위한 데이터자동취득 및 원격진단시스템 구축)

  • Kang, Sang-Mu;Kang, Dae-Jeong;Han, Hyun-Seok;Kim, Won-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.707-708
    • /
    • 2015
  • This paper proposes a method for improving efficiency of high-voltage motors off-line insulation diagnostic test. The conventional manual test method has measurement errors and excessive processing time. We developed the KITAS system and solved these problems by using the instrument remote control and communication technology. The result of proficiency testing by interlaboratory comparisons using Power Factor Tip-Up test was '${\mid}E_n{\mid}$ < 1'. It was possible to confirm the validity of acquired data from the KITAS and establish a remote diagnostic system for easy access without physical limitations.

  • PDF

DC/AC Hybrid Distribution System Analysis for Improving Energy Efficiency (에너지 효율 향상을 위한 직류/교류 하이브리드 급전시스템의 해석)

  • Lee, Young-Jin;Han, D.H.;Choi, J.M.;Ban, C.H.;Kim, Dong-Jin;Choe, Gyu-ha
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.244-245
    • /
    • 2010
  • Hybrid distribution system is able to use existing AC load under AC power and DC power by providing existing AC power and proper DC voltage at the same time. and, the future expected DC appliance is also available. Hybrid distribution system is divided into two different type. the one is DC common method and the other is AC common method. This paper design each system, and study operating characteristics for improving energy efficiency.

  • PDF

POSCO's Research and Development works on rare earth reduced NdFeB magnets production process

  • Yuh, Junhan
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2013.12a
    • /
    • pp.90-90
    • /
    • 2013
  • Since discovery, NdFeB permanent magnet has replaced application of the conventional magnets rapidly because of its superior physical and mechanical properties. With increasing consumption of power combined with energy resource depletion, energy efficiency is becoming more and more inportant. According to recent reports, almost almost half of the electric power is consumed by motor, and NdFeB magnets which are the core component of the motor play a key role on improving energy efficiency of the devices. In parallel with finding alternatives energy resources, research works improving energy efficiecy have been conducted world wide. Althogh NdFeB magnets usage have been expanded to various applications, key materials such as Nd and Dy, resouces lean heavily on specific area, China. Magnetic industry revently experienced skyrocketing price fluctuatioin of rare earth at around 2008. Chineses government's regulations worsened the situation and arose a necessity to develop methods to minimize rare earth use. In this presentation, POSCO's recent research works on rare earth reduction is presented including novel powder alloying method using nitrate precursors. Also, future R&D plans for rare earth free magnets is briefly introduced as well.

  • PDF

A Study on Development of Balanced ScoreCard Personnel Assessment Using of Safety Duty Using National Competency Standards (국가직무능력표준을 활용한 안전직무의 BSC 인사평가 시스템 개발)

  • Yang, Kwang Mo
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.2
    • /
    • pp.27-34
    • /
    • 2015
  • If examining utilization by completion of National Competency Standards development, efforts are made so as to organize curriculum matched to education or training and perform subjects based on competence unit educationally in specialized high schools, colleges and university. However, National Competency Standards is insignificantly utilized in enterprises and on the spot due to characteristics of occupation type and diversity of process. This thesis intended to measures of safety efficiency improvement of final enterprise through the human resources assessment system of National Competency Standards based enterprise. Therefore, various methodologies were introduced and results of analysis by Balanced ScoreCard method were suggested for policy measures improving final safety efficiency. The results of this analysis are expected to make contribution to improving the effectiveness of the government's industrial safety and health policies through the establishment of systematic safety and health systems according to the risk level of individual business.

Improving efficiency of remote data audit for cloud storage

  • Fan, Kuan;Liu, Mingxi;Shi, Wenbo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.4
    • /
    • pp.2198-2222
    • /
    • 2019
  • The cloud storage service becomes a rising trend based on the cloud computing, which promotes the remote data integrity auditing a hot topic. Some research can audit the integrity and correctness of user data and solve the problem of user privacy leakage. However, these schemes cannot use fewer data blocks to achieve better auditing results. In this paper, we figure out that the random sampling used in most auditing schemes is not well apply to the problem of cloud service provider (CSP) deleting the data that users rarely use, and we adopt the probability proportionate to size sampling (PPS) to handle such situation. A new scheme named improving audit efficiency of remote data for cloud storage is designed. The proposed scheme supports the public auditing with fewer data blocks and constrains the server's malicious behavior to extend the auditing cycle. Compared with the relevant schemes, the experimental results show that the proposed scheme is more effective.

Evaluating Performance of Telecommunication Branch : Application of DEA with Non-Discretionary Factor (통신지사의 성과평가 : 비재량 요인을 포함한 DEA 적용)

  • Kwon, Sun-Man;Han, Chang Hee
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.40 no.4
    • /
    • pp.21-28
    • /
    • 2017
  • Improving efficiency of the telecommunication is crucial to the development and growth of Korean economy. Recently, it has become important with the huge development of information technology and its greater potential for extensive impact on the rest of the economy. Hence, it is useful to determine the factors that help enhance efficiency in telecommunication and consider them in improving the evaluation model. This study applies DEA (data envelopment analysis) to evaluate the relative efficiency of 51 branches of a Korean telecommunication company. Using the super-efficiency approach, we tested outliers which may affect the results and ranked the efficient branches. A method of deriving key variables applied to business operation is proposed to identify the key performance indicators for evaluation that takes environmental (non-discretionary) factors into account. We used the extended CCR model proposed by Banker and Morey to investigate the influence of non-discretionary factor. The information provided by the model (slacks, weights) and the sensitivity analysis shows that the most important indicator that affects the branch performance is operating cost. The results of sensitivity analysis show that average efficient score decreases from 0.972 (base case) to 0.863 for CASE2-COST. The average score of the data proves the priority of operating cost over other indicators. The effect of environmental (non-discretionary) variable was found to be significant. The population effect was positive and improved overall efficiency by 0.91% on average. Non-discretionary factor plays a meaningful role explaining the performance of branches. The performance optimization report can help a manager of an inefficient branch to develop branch strategies. Managers can identify the top-performing units, study best practices and adopt the strategy to the organization.

Development of Control Method for Improving Energy Efficiency of Unmanned Underwater Gliders (무인 수중글라이더의 에너지 효율 개선을 위한 제어방법 개발)

  • La, Seung-kyu;Ko, Sung-hyup;Ji, Dae-hyeong;Chon, Seung-jae;Jeong, Seong-hoon;Choi, Hyeung-sik;Kim, Joon-young
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.2
    • /
    • pp.105-112
    • /
    • 2022
  • In this paper, unmanned underwater glider was designed for high-depth operation and adopted a bladder-type buoyancy controller for improving battery efficiency, and the motion controller controls the pitch angle by moving the internal mass battery. To improve the energy efficiency of the unmanned underwater glider, a layered PID controller that performs control by section was designed. Simulation program including 6-DOF motion equations and hydrodynamics coefficients of an unmanned underwater glider is constructed using Matlab/Simulink program. Control methods such as PID controller, sliding mode controller and layered PID controller were applied to the simulator to compare the dynamics performance and energy efficiency. As a result, the layered PID controller showed improved control performance compared to other controllers and improved energy efficiency of approximately 7.2% compared to PID controller.

High Efficiency Design Considerations for the Self-Driven Synchronous Rectified Phase-Shifted Full-Bridge Converters of Server Power Systems

  • Cetin, Sevilay
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.634-643
    • /
    • 2015
  • This paper presents a high frequency design approach for improving efficiency over a wide load range in the self-driven phase-shifted full-bridge converters for server power systems. In the proposed approach, a detailed ZVS analysis of the lagging leg switches in both the continuous conduction mode (CCM) and the discontinuous conduction mode (DCM) is presented. The optimum dead time and the determination of the appropriate operation mode are given for high efficiency according to the load conditions. Finally, the optimum operation conditions are defined to achieve a high-efficiency. A laboratory prototype operating at 80 kHz, rated 1 kW (12 V-83.3 A), is built to verify proposed theoretical analysis and evaluations. The experimental results show that the maximum efficiency is achieved as 95% and 83.5% at full load and 5% load conditions, respectively.

Analysis and Efficiency Control of Linear Compressor System for Refrigerator Driven by PWM Inverter (PWM인버터로 구동되는 냉장고용 선형압축기시스템의 특성해석 및 효율제어)

  • Son, Jang-Kyung;Chun, Tae-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1544-1549
    • /
    • 2013
  • Recently, the linear compressors with the free piston driven by the linear motor have widely attention in the cooling apparatus such as a refrigerator due to high efficiency. The method of using triacs as a linear motor drive is not satisfactory to improve the efficiency of the linear compressor. In this paper, the performance of the linear compressor using a PWM inverter such as the efficiency is investigated with the variations of both mechanical resonant frequency and electrical resonant frequency. The control loop for controlling both the piston stroke and efficiency is suggested. Through simulation and experimental studies, the performance of both the stroke and angle controls for improving the efficiency of the linear compressor is verified.