Algorithm for the Low-Voltage Feeder Design in Consideration of Voltage Drop (전압강하를 고려한 저압간선의 설계 알고리즘)

  • 고영곤;최홍규;조계술
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.3
    • /
    • pp.84-92
    • /
    • 2002
  • A size of low-voltage conductor cables is determined by the voltage drop of a system the cable impedance and the cable ampacity based on temperature correction factor in accordance with the condition of cable installation. Therefore, the proper temperation correction factor according to the condition of cable installation should be applied to determining the cable ampacity and also the skin effect and proximity effect, along with the kind and size of conductor and the condition of cable installation, should be properly considered to analyze the proper value of resistance and the reactance of the conductors. This paper addresses the systematic design flow for determining the size of low voltage level con여ctor cables in calculating the voltage drop of a power system and proposes a new improved the calculating formula what error should be minimized in comparison with the general formula and which can be applied in design work for determining the size of conductor cables.

A Study on Hand Speed Constant to Calculate Safe Distance of Press Protective Device (프레스 방호장치 안전거리 산정을 위한 손속도상수)

  • Lee, Keun-Oh;Kim, Jong-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.40-46
    • /
    • 2010
  • To protect press operator from the after-reach hazard, current Ministry of Labor Notification(MOLN) requires the use of a formula for calculating the safe distance away from the point of operation for locating press protective devices, Two Hand Control Devices(THCD) and Active Opto-Electronic Protective Devices(AOPD), on a power press. This formula is based on a same hand speed constant of 160cm/s. While EN standards use different hand speed constant for THCD and AOPD respectively. The objective of this study is to compare two guidelines on the hand speed constant published by MOLN and EN 692, also to propose a proper hand speed constant and validate it experimentally. As a experimental result, it could be known that hand speed constant of Ministry of Labor Notification should be improved as that of EN standards.

A Study on the Improvement of the Arithmetic for Emergency Generator Capacity (비상발전기용량 산정식 개선에 관한 연구)

  • Lee, Jong-Hyuk;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1517-1522
    • /
    • 2018
  • This paper describes the improvement of the arithmetic for emergency generator capacity. This formula which calculates emergency generator is dependent on the Korean Design Standard of building electrical equipment issued by the Ministry of Land, Infrastructure and Transport, and the technical data related to the generator. when appling the formula, the capacity of the generator is insufficient at the starting conditions of the load facility. In case of emergency, the generator is not operated normally. $PG_2$ of the formula ($PG_1$, $PG_2$, $PG_3$) applied in determining the capacity of the emergency generator is selected by calculating the capacity of the generator based on only biggest one motor among the load equipment and $PG_3$ may not be able to start the generator normally in case of emergency because there is an error such that the power factor is applied at the last start of the motor having the maximum capacity of the load. We analyze the problem of capacity calculation of emergency generators used for general purposes. As a consequence, the improved formulas have been presented for safety of electrical installation.

A method of optimum design based on reliability for antenna structures

  • Chen, Jianjun;Wang, Fanglin;Sun, Huaian;Zhang, Chijiang
    • Structural Engineering and Mechanics
    • /
    • v.8 no.4
    • /
    • pp.401-410
    • /
    • 1999
  • A method of optimum design based on reliability for antenna structures is presented in this paper. By constructing the equivalent event, the formula is derived for calculating the reliability of reflector accuracy of antenna under the action of random wind load. The optimal model is developed, in which the cross sectional areas of member are treated as design variables, the structure weight as objective function, the reliability of reflector accuracy and the strength or stability of structural elements as constraints. The improved accelerated convergence gradient algorithm developed by the author is used. The design results show that the method in this paper is feasible and effective.

Study on Improved Method for Calculating Runoff Coefficient of Rational Method (합리식의 유출계수(C) 산정방법의 개선에 관한 연구)

  • Lee, Young-Dai;Kim, Jong-Soon;Kim, Young-Teak
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.4
    • /
    • pp.67-74
    • /
    • 2007
  • Rational method has been widely used to calculate peak runoff drainage design or small watershed because of simplicity and convenience. Runoff coefficient(C) is the most important parameter in the rational method which varies according to rainfall intensity, return period, rainfall duration time and soil characteristics. In practice, constant which is value of C in rational formula has been used from the table, originally based on ASCE. These table value does not consider the upper conditions of the depending factors, hence peak runoff calculation could be in correct. Therefore to calculate C in this paper we have devised an improved formula, considering relationship with rainfall duration, return period and CN of NRCS method. This formula is considered to be more reliable and helpful to the hydrologists and engineers to predict correct peak runoff.

A study on the improvement of the thermal expansion formula of the insulating oil in electric facilities (전력설비 절연유 열팽창 계산식 개선에 관한 연구)

  • Rim, Seong-Hwang;Moon, Bong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.153-156
    • /
    • 2001
  • The transformer and the OF cable are cooled and insulated by insulating oils in their body. The insulating oil expands or contracts with the heat transfer according to the operating conditions of the electric facilities. So we install the $N_2$ gas tank connected with the insulating oil system to overcome the change. The change of the insulating oil volume for the operation temperature range must be calculated to decide the $N_2$ gas volume and to set the alarm point for safe operation. It is known that this change is proportional to the temperature change and to the insulating oil volume if the temperature change is small enough.[1][11] However this proportional formula has been accepted generally in the design of electric facilities for wide operation temperature range such as $40^{\circ}C{\sim}125^{\circ}C$. Hence, it makes large errors in calculation which car result in serious damage against safe operation of the electric facilities. This paper presents a improved method of calculating the accurate change of the insulating oil volume to insure the safe operation of electric facilities.

  • PDF

A Study on the Accuracy Improvement of One-repetition Maximum based on Deep Neural Network for Physical Exercise

  • Lee, Byung-Hoon;Kim, Myeong-Jin;Kim, Kyung-Seok
    • International journal of advanced smart convergence
    • /
    • v.8 no.2
    • /
    • pp.147-154
    • /
    • 2019
  • In this paper, we conducted a study that utilizes deep learning to calculate appropriate physical exercise information when basic human factors such as sex, age, height, and weight of users come in. To apply deep learning, a method was applied to calculate the amount of fat needed to calculate the amount of one repetition maximum by utilizing the structure of the basic Deep Neural Network. By applying Accuracy improvement methods such as Relu, Weight initialization, and Dropout to existing deep learning structures, we have improved Accuracy to derive a lean body weight that is closer to actual results. In addition, the results were derived by applying a formula for calculating the one repetition maximum load on upper and lower body movements for use in actual physical exercise. If studies continue, such as the way they are applied in this paper, they will be able to suggest effective physical exercise options for different conditions as well as conditions for users.

Design and Application of a Single Phase Multilevel Inverter Suitable for using as a Voltage Harmonic Source

  • Beser, Ersoy;Arifoglu, Birol;Camur, Sabri;Beser, Esra Kandemir
    • Journal of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.138-145
    • /
    • 2010
  • This paper presents a single phase multilevel inverter for using as a voltage harmonic source. First, a single phase multilevel inverter system is presented and the structural parts of the inverter are described. In order to obtain multilevel output voltage waveforms, a switching strategy based on calculating switching angles is explained and an improved formula for determining switching angles is given. Simulation and experimental results of multilevel voltage waveforms are given for 15, 31 and 127 levels. The proposed topology does not only produce output voltages with low THD values. It also produces the required harmonic components on the output voltage. For this purpose, equations for switching angles are constituted and the switching functions are obtained. These angles control the output voltage as well as provide the required specific harmonics. The proposed inverter structure is simulated for various functions with the required harmonic components. The THD values of the output voltage waves are calculated. The simulated functions are also realized by the proposed inverter structure. By using a harmonic analyzer, the harmonic spectrums, which belong to the output voltage forms, are found and the THD values are measured. Simulation and experimental results are given for the specific functions. The proposed topology produces perfectly suitable results for obtaining the specific harmonic components. Therefore, it is possible to use the structure as a voltage harmonic source in various applications.

A dryout mechanism model for rectangular narrow channels at high pressure conditions

  • Song, Gongle;Liang, Yu;Sun, Rulei;Zhang, Dalin;Deng, Jian;Su, G.H.;Tian, Wenxi;Qiu, Suizheng
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2196-2203
    • /
    • 2020
  • A dryout mechanism model for rectangular narrow channels at high pressure conditions is developed by assuming that the Kelvin-Helmholtz instability triggered the occurrence of dryout. This model combines the advantages of theoretical analysis and empirical correlation. The unknown coefficients in the theoretical derivation are supported by the experimental data. Meanwhile, the decisive restriction of the experimental conditions on the applicability of the empirical correlation is avoided. The expression of vapor phase velocity at the time of dryout is derived, and the empirical correlation of liquid film thickness is introduced. Since the CHF value obtained from the liquid film thickness should be the same as the value obtained from the Kelvin-Helmholtz critical stability under the same condition, the convergent CHF value is obtained by iteratively calculating. Comparing with the experimental data under the pressure of 6.89-13.79 MPa, the average error of the model is -15.4% with the 95% confidence interval [-20.5%, -10.4%]. And the pressure has a decisive influence on the prediction accuracy of this model. Compared with the existing dryout code, the calculation speed of this model is faster, and the calculation accuracy is improved. This model, with great portability, could be applied to different objects and working conditions by changing the expression of the vapor phase velocity when the dryout phenomenon is triggered and the calculation formula of the liquid film.

Comparison among Gamma(${\gamma}$) Line Systems for Non-Linear Gamma Curve (비선형 감마 커브를 위한 감마 라인 시스템의 비교)

  • Jang, Won-Woo;Lee, Sung-Mok;Ha, Joo-Young;Kim, Joo-Hyun;Kim, Sang-Choon;Kang, Bong-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.2
    • /
    • pp.265-272
    • /
    • 2007
  • This proposed gamma (${\gamma}$) correction system is developed to reduce the difference between non-linear gamma curve produced by a typical formula and result produced by the proposed algorithm. In order to reduce the difference, the proposed system is using the Least Squares Polynomial which is calculating the best fitting polynomial through a set of points which is sampled. Each system is consisting of continuous several kinds of equations and having their own overlap sections to get more precise. Based on the algorithm verified by MATLAB, the proposed systems are implemented by using Verilog-HDL. This paper will compare the previous algorithm of gamma system such as Existing system with Seed Table with the latest that such as Proposed system. The former and the latter system have 1, 2 clock latency; each 1 result per clock. Because each of the error range (LSB) is $1{\sim}+1,\;0{\sim}+36$, we can how that Proposed system is improved. Under the condition of SAMSUNG STD90 0.35 worst case, each gate count is 2,063, 2,564 gates and each maximum data arrival time is 29.05[ns], 17.52[ns], respectively.