• Title/Summary/Keyword: Improve Response Time

Search Result 912, Processing Time 0.033 seconds

A study on Web 2.0 Technology for Mobile Medical Online Appointment (모바일 진료예약을 위한 Web 2.0 기술 연구)

  • Roh, Il-Soon;Choi, Hee-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.2
    • /
    • pp.129-135
    • /
    • 2009
  • Most Hospitals develop a Medical online appointment system for u-Hospital which system based on Web Application. Web 2.0 technology has good user interface and fast response time in a web service. This paper proposed a Mobile Medical Online Appointment System using Web 2.0 Technology. This system improve the page view, convenient UI and fast response time. We test this system with evermedi, other hospital system in iwebtools service and show that it can improve the efficiency and perfomance. The proposed technology can improve the efficient mobile service because it can be extended to ubiquitous mobile application.

  • PDF

The Effects of Abdominal Relaxed Breathing Training on Stress response and Blood Pressure for Elderly Hypertensionve Patient (고혈압 노인에서 복식호흡 이완훈련이 혈압 및 스트레스 반응에 미치는 영향)

  • 유수정;송미순
    • Journal of Korean Academy of Nursing
    • /
    • v.31 no.6
    • /
    • pp.998-1011
    • /
    • 2001
  • In order to improve self-management of elderly hypertensives in this study, the researcher examined the effect of blood pressure regulation by an abdominal relaxed breathing training which regulates physical response to stress and lessens the activity of the sympathetic nerve. Method: A quasi-experimental pre-test and post-test design was used. Thirty elderly hypertensive patient ; Sixteen in the abdominal breathing group and fourteen in the control group participated in this study. The abdominal relaxed breathing training consisted of eight sessions twice a week for four weeks. There was no intervention for the control group. Result: 1. There was a significant decrease in systolic and diastolic blood pressure between the experimental group and control group over three different times, and interaction by groups and over time. 2. There was no significant difference in the level of total stress response, physical stress response, behavioral-cognitive stress response between the experimental group and control group over three different times, and interaction by groups and over time. Conclusion: Findings indicate that this study will contribute to develop nursing strategies for the regulation of blood pressure for the elderly, which is easy for the elderly to learn as a nonpharmacologic approach.

  • PDF

Improvement of the Response Characteristics Using the Fuzzy-PLL Controller (퍼지-PLL 제어기를 이용한 응답특성 개선)

  • Cho, Jeong-Hwan;Seo, Choon-Weon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.175-181
    • /
    • 2005
  • This paper proposes the fuzzy-PLL control system for fast response time and precision control of automation systems. The conventional PLL has not only a jitter noise caused from such a demerit of the wide dead zone, but also a long delay interval that makes a high speed operation unable. In order to solve the problems, the proposed system, which provides the improvement in terms of the control region in high speed and precision control, first used the fuzzy control method for fast response time and when the error reaches the preset value, used the PLL method designing new PFD for precision control. The new designed multi-PFD improves the dead zone, jitter noise and response characteristics, which is consists of P-PFD(Positive edge triggered PFD) and N-PFD(Negative edge triggered PFD) and can improve response characteristics to increase PFD gain.

Capless Low Drop Out Regulator With Fast Transient Response Using Current Sensing Circuit (전류 감지 회로를 이용한 빠른 과도응답특성을 갖는 capless LDO 레귤레이터)

  • Jung, Jun-Mo
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.552-556
    • /
    • 2019
  • This paper present a capless low drop out regulator (LDO) that improves the load transient response characteristics by using a current regulator. A voltage regulator circuit is placed between the error amplifier and the pass transistor inside the LDO regulator to improve the current characteristics of the voltage line, The proposed fast transient LDO structure was designed by a 0.18 um process with cadence's virtuoso simulation. according to test results, the proposed circuit has a improved transient characteristics compare with conventional LDO. the simulation results show that the transient of rising increases from 1.954 us to 1.378 us and the transient of falling decreases from 19.48 us to 13.33 us compared with conventional capless LDO. this Result has improved response rate of about 29%, 28%.

Low-noise fast-response readout circuit to improve coincidence time resolution

  • Jiwoong Jung;Yong Choi;Seunghun Back;Jin Ho Jung;Sangwon Lee;Yeonkyeong Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1532-1537
    • /
    • 2024
  • Time-of-flight (TOF) PET detectors with fast-rise-time scintillators and fast-single photon time resolution silicon photomultiplier (SiPM) have been developed to improve the coincidence timing resolution (CTR) to sub-100 ps. The CTR can be further improved with an optimal bandwidth and minimized electronic noise in the readout circuit and this helps reduce the distortion of the fast signals generated from the TOF-PET detector. The purpose of this study was to develop an ultra-high frequency and fully-differential (UF-FD) readout circuit that minimizes distortion in the fast signals produced using TOF-PET detectors, and suppresses the impact of the electronic noise generated from the detector and front-end readout circuits. The proposed UF-FD readout circuit is composed of two differential amplifiers (time) and a current feedback operational amplifier (energy). The ultra-high frequency differential (7 GHz) amplifiers can reduce the common ground noise in the fully-differential mode and minimize the distortion in the fast signal. The CTR and energy resolution were measured to evaluate the performance of the UF-FD readout circuit. These results were compared with those obtained from a high-frequency and single ended readout circuit. The experiment results indicated that the UF-FD readout circuit proposed in this study could substantially improve the best achievable CTR of TOF-PET detectors.

A Time Integration Method for Analysis of Dynamic Systems Using Domain Decomposition Technique

  • Fujikawa Takeshi;Imanishi Etsujiro
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.spc1
    • /
    • pp.429-436
    • /
    • 2005
  • This paper presents a precise and stable time integration method for dynamic analysis of vibration or multibody systems. A total system is divided into several subsystems and their responses are calculated separately, while the coupling effect is treated equivalently as constant force during time steps. By using iterative procedure to improve equivalent coupling forces, a precise and stable solution is obtained. Some examples such as a seismic response and multibody analyses were carried out to demonstrate its usefulness.

Experimental identification of nonlinear model parameter by frequency domain method (주파수영역방법에 의한 비선형 모델변수의 실험적 규명)

  • Kim, Won-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.2
    • /
    • pp.458-466
    • /
    • 1998
  • In this work, a frequency domain method is tested numerically and experimentally to improve nonlinear model parameters using the frequency response function at the nonlinear element connected point of structure. This method extends the force-state mapping technique, which fits the nonlinear element forces with time domain response data, into frequency domain manipulations. The force-state mapping method in the time domain has limitations when applying to complex real structures because it needd a time domain lumped parameter model. On the other hand, the frequency domain method is relatively easily applicable to a complex real structure having nonlinear elements since it uses the frequency response function of each substurcture. Since this mehtod is performed in frequency domain, the number of equations required to identify the unknown parameters can be easily increased as many as it needed, just by not only varying excitation amplitude bot also selecting excitation frequency domain method has some advantages over the classical force-state mapping technique in the number of data points needed in curve fit and the sensitivity to response noise.

Two Supplementary Methods of PI-Type Fuzzy Logic Controllers

  • Lee, Jihong;Seog Chae
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.891-894
    • /
    • 1993
  • To improve limitations of fuzzy PI controller especially when applied to high order systems, we propose two types of fuzzy logic controllers that take out appropriate amounts of accumulated control input according to fuzzily described situations in addition to the incremental control input calculated by conventional fuzzy PI controllers. The structures of the proposed controller were motivated by the problems of fuzzy PI controllers that they generally give inevitable overshoot when one tries to reduce rise time of response especially when one tries to reduce rise time of response especially when a system of order higher than one is under consideration. Since the undesirable characteristics of the fuzzy PI controller are caused by integrating operation of the controller, even though the integrator itself is introduced to overcome steady state error in response, we propose two fuzzy controllers that fuzzily clear out integrated quantities according to situation. The first contr ller determines the fuzzy resetting rate by situations described fuzzily by error and error rate, and the second one by error and control input. The two structures both give reduced rise time as well as small overshoot. To show the usefulness of the proposed controller, that are applied to systems that are difficult to get satisfactory response by conventional fuzzy PI controllers.

  • PDF

Robust Time Delay Compensation for DTC-Based Induction Machine Systems via Extended State Observers

  • Wang, Fengxiang;Wang, Junxiao;Yu, Li
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.736-745
    • /
    • 2018
  • This paper presents an extended state observer (ESO) based direct torque control (DTC) for use in induction motor systems to handle the issues of time delays, load torque disturbances and parameter uncertainties. Direct torque control offers an excellent torque response and it does not require a proportion integration (PI) controller in the current loop. However, a PI controller is still adopted in the outer speed loop to generate the torque reference value, which is a slow method. An ESO based compound control scheme is proposed to improve the response rate and accuracy of the torque reference signal, especially when load torque is injected. In addition, the time delay problem is analyzed and compensated for in this paper to reduce torque ripples. The proposed disturbance compensation technique based direct control scheme is shown to have good performance both in the transient and stable states via simulations and experimental results.

Implementation and Test of Hydraulic Control System for the Tractor Leveling (트랙터의 수평제어를 위한 유압 시스템의 특성 실험)

  • Lee, S. S.;Oh, K. S.;Hwang, H.
    • Journal of Biosystems Engineering
    • /
    • v.24 no.5
    • /
    • pp.383-390
    • /
    • 1999
  • When a tractor travels slope lands, problems of operator safety and the reduction of job efficiency usually occur. Therefore, maintaining the tractor body being horizontal is critical to improve the security of traveling and the job performance. An experiment was made in a soil bin using the experimental model system built and equipped with a leveling control system. Adaptability of the control system was tested and investigated by analyzing system response in time and frequency domains. Control response time of hydraulic cylinder with 10lpm flow rate on a step input of 10$^{\circ}$slope was about 0.42sec. And it showed a linearly increasing trend without any hunching state. A steady state error of 0.6$^{\circ}$occurred but it was negligible. The hydraulic control system showed a little phase differences within the range of 0.4Hz input frequency. The experimental model showed that implementation of the proposed tractor control system to on slope lands tractor was feasible.

  • PDF