• Title/Summary/Keyword: Impression technique

Search Result 176, Processing Time 0.023 seconds

Comparison of marginal fit of metal copings according to wax blocks and oral scanning methods (구강인기법과 왁스블록의 종류에 따른 금속 코핑의 변연적합도 비교)

  • Chung, In-Sung;Kim, Won-Young;Jeon, Byung-Wook
    • Journal of Technologic Dentistry
    • /
    • v.42 no.3
    • /
    • pp.234-239
    • /
    • 2020
  • Purpose: We investigated the marginal fit between abutment and metal copings according to impression technique, wax block types, and metal types. Methods: We selected the traditional impression method of using rubber impression materials and the digital impression method of using oral scanners, three types of wax blocks, and two types of metal, both of which were domestically and commercially available, were selected to produce metal copings, and the marginal fit was determined through the use of silicon replication. Results: The measurements of axial wall fit revealed that the IYV specimens had the best fit, with a mean gap of 24.11±5.95 ㎛, followed by CEV, CHV, CSS, CSV, CES, CHS, and IYS specimens (mean: 33.44±8.41 ㎛). The differences were not statistically significant. The marginal gap measurements showed that the CEV specimen had the smallest gap, 17.25±4.13 ㎛, followed by the CSV, CHV, CSS, CES, CHS, IYV, and IYS specimen (mean: 43.47±15.63 ㎛). The differences were statistically significant. Conclusion: The axial wall fit of the metal coping (VeraBond2V; Aalba Dent, Inc., Fairfield, CA, USA) produced by the lost wax technique with the traditional impression method was excellent. The marginal fit of the metal coping (VeraBond 2V) produced by wax milling with the use of an oral scanner was also excellent. The marginal fit of the metal coping was within the clinically acceptable limits in all groups.

A comparative study on the accuracy of impression body according to the types of impression tray (임플란트 인상 채득 시 트레이 종류에 따른 인상체의 정확도에 관한 비교 연구)

  • Yi, Hyun-Jung;Lim, Jong-Hwa;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.48-54
    • /
    • 2010
  • Purpose: The objective of this study was to evaluate and compare the accuracy of impression body taking by the closed and the open tray impression technique with 3 types of impression tray. Individual tray, metal stock tray and polycarbonate tray were used. Materials and methods: Nine closed tray impressions were taken by individual tray, metal stock tray and polycarbonate stock tray, respectively with polyether impression material. 9 open tray impressions were also acquired by same manner. Precision analysis on the master models was performed by attaching the reference frameworks with alternate single screws and measuring the vertical fit discrepancy of respective analogues in working cast with a stereo microscope. Data were analyzed by 1 way ANOVA and independent t-test. Results: The average fit accuracy of impression bodies was calculated. With the closed tray impression technique, there were significant statistical differences in vertical fit discrepancy according to the types of tray. The individual tray group showed the lowest value and the polycarbonate stock tray group represented the highest. With the open tray impression technique, there was no significant difference in vertical fit discrepancy. Significant statistical difference in vertical fit discrepancy was found between the open and the closed impression technique with the polycarbonate stock tray. Conclusion: From the results above, more precise impressions could be acquired by the rigid individual tray compared with the polycarbonate stock tray. It was hard to get consistent accuracy impressions by the closed tray impression technique with polycarbonate stock trays.

Accuracy of five implant impression technique: effect of splinting materials and methods

  • Lee, Sang-Jik;Cho, Sung-Bum
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.4
    • /
    • pp.177-185
    • /
    • 2011
  • PURPOSE. The aim of this study was to evaluate the effect of dimensional stability of splinting material on the accuracy of master casts. MATERIALS AND METHODS. A stainless steel metal model with 6 implants embedded was used as a master model. Implant level impressions were made after square impression copings were splinted using 5 different techniques as follows. (1) Splinted with autopolymerizing resin and sectioned, reconnected to compensate polymerization shrinkage before the impression procedure. (2) Splinted with autopolymerizing resin just before impression procedure. (3) Primary impression made with impression plaster and secondary impression were made over with polyether impression material. (4) Splinted with impression plaster. (5) Splinted with VPS bite registration material. From master model, 5 impressions and 5 experimental casts, total 25 casts were made for each of 5 splinting methods. The distortion values of each splinting methods were measured using coordinate measuring machine, capable of recordings in the x-, y-, z- axes. A one-way analysis of variance (ANOVA) at a confidence level of 95% was used to evaluate the data and Tukey's studentized range test was used to determine significant differences between the groups. RESULTS. Group 1 showed best accuracy followed by Group 3 & 4. Group 2 and 5 showed relatively larger distortion value than other groups. No significant difference was found between group 3, 4, 5 in x-axis, group 2, 3, 4 in y-axis and group 1, 3, 4, 5 in z-axis (P<.0001). CONCLUSION. Both Splinting impression copings with autopolymerizing resin following compensation of polymerization shrinkage and splinting method with impression plaster can enhance the accuracy of master cast and impression plaster can be used simple and effective splinting material for implant impression procedure.

Maxillary anterior all ceramic restoration using digital impression and CAD/CAM (디지털 인상채득 및 CAD/CAM을 이용한 상악 전치부 보철물 제작과 기존 방식 보철물과의 임상적 비교)

  • Pyo, Se-Wook;Park, Young-Bum;Kim, Jee-Hwan;Moon, Hong-Suk;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.263-269
    • /
    • 2011
  • The digital impression technique has been developed for more precise restorations and convenient procedures in prosthodontic treatment compared to the conventional impression technique. Along with the utilization of CAD/CAM, the introduction of digital impression technique actualizes the digitalization of dental treatments. This case is to compare two different prostheses introducing each procedure in detail; one from CAD/CAM after taking digital impression and the other from the conventional technique. A 22-year-old female visited the clinic with the chief complaint of correction of discoloration and shape on maxillary right central incisor. Due to the trauma 8 years ago, the tooth was endodontically treated with post and resin core. The treatment was planned and the procedures were conducted under the patient's consent to treat the tooth with all ceramic crowns in two different ways for comparison. In conclusion, both prostheses presented clinically acceptable results with comparing the internal fitness of two all ceramic crowns. The prosthesis from digital impression, however, showed more errors in respect of internal fitness.

Digital intraoral impression for immediate provisional restoration of maxillary single implant: A case report (구강 내 디지털 인상채득을 통한 상악 전치부 임플란트 즉시 임시 보철 수복 증례)

  • Chang, Yun-Jeong;Kim, Hong-Jun;Song, Mi-Kyoung;Moon, Ji-Eun;Lee, Hal-La;Park, Chan-Ik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.234-243
    • /
    • 2015
  • Developing of digital technique, it is possible to fabricate implant prostheses for edentulous area using intraoral 3-dimentional information throughout implant diagnosis and treatment process. It is being changed that from the method using CAD/CAM, producing prostheses by model scanning after conventional impression and model processing, to the method of fabricating implant provisional restorations and customized abutments by digital impression after connecting digital impression copings (scanbody) and implant fixtures without models. But, this digital method has not been actively used for implant prostheses not yet. Specially, it is short of intraoral digital impression cases for immediate provisional restorations of the maxillary anterior implants. The gingival contour impression of maxillary anterior area is very important for esthetic restorations. Accordingly, in this case report, the using a digital impression coping (scanbody) and digital impression by CEREC Omnicam (Sirona, Bensheim, Germany) or Trios (3shape, Copenhagen, Denmark) were introduced for immediate provisional restorations in 3 cases needed a single implant restoration in maxillary anterior area. The clinical results were satisfactory on the convenience and accuracy of digital impression technique and the good esthetics of final restorations.

Suitable scanning procedures for various prosthodontic treatments and the utilization of intraoral scanner (임상가를 위한 특집 3 - 여러 보철 치료 술식에 따른 바른 스캐닝 과정과 구강스캐너의 활용)

  • Park, Ji-Manm;Park, Eun-Jin;Heo, Seong-Joo
    • The Journal of the Korean dental association
    • /
    • v.52 no.6
    • /
    • pp.354-362
    • /
    • 2014
  • With the development of digital dentistry, various intra-oral scanners which acquire intraoral image without conventional impression taking and stone pouring steps have been introduced. Fixed dental prostheses such as inlay, onlay, crown, and bridge fabricated by CAD/CAM technique combined with digital impressions is getting popular due to the recent rapid progress of digital impression taking system. In comparison with traditional prosthetic procedure, the advantages of intraoral image acquiring and CAD/CAM technique are as follows; the omission of conventional impression materials, reduced workflow step, and increased efficiency by online communication with clinic and laboratory. This review article covers some opinions about the suitable scanning procedures for the various prosthodontic treatments and the utilization of digital intraoral scanner and CAD/CAM system.

Empirical study of impression formation factors in 3D cyber space : Analysis focused on Second Life (3D 가상공간에서의 인상 형성에 관한 실증적 연구 : 세컨드 라이프를 중심으로 인상 형성 요인 분석)

  • Kim, Hee-Sun;Lee, Jae-Hee;Jang, Su-Jin;Park, Su-E
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02b
    • /
    • pp.513-520
    • /
    • 2008
  • Today, 3D cyber space with advancements of Web 3D technique is changing into a social space. As such, the users want to make social relationships, the impression that one leaves in 3D cyber space has become more important. This study will be confirm a relationship between interpersonal relations and impression and show some impression formation factors in 3D cyber space. As this study analyzes the characteristic elements of 3D cyber space which are differentiated with other platform, it has theoretical value to support theory about personal relationship in3D cyber spaces. Then it will be a supporting theory for next study about intercultural and social phenomena in changeable 3D cyber space as advancement of technique. We will find out the causal relationship between impression dimensions and formative factors in next study.

  • PDF

Implant-assisted removable partial denture for severely atrophied mandible (심한 하악 치조제 흡수를 가진 환자에서 임플란트를 이용한 가철성 국소의치로 수복한 증례)

  • Choi, Bada;Kim, Yeun Ju;Lee, Jae Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.171-175
    • /
    • 2019
  • Mandible with severe alveolar bone atrophy poses a significant challenge in terms of reproducing clinically acceptable anatomy for a removable prosthesis. To overcome this potential complication, altered cast impression technique is often recommended to capture accurate and functional gingiva tissues. It becomes possible to get proper anchors functional impression by placing 2 implants crowns which were impossible in previous implant overdenture impression technique. In this case, an 80-year old female patient with severe mandibular ridge atrophy was treated with an implant-assisted removable partial denture with two implant crowns on the canine area. An altered cast impression was taken with an individual tray on a metal framework of removable partial denture on both posterior edentulous areas. The patient was satisfied with the final prosthesis after failure of 2 previous prostheses. Clinician had a difficult time to manage disabled patient and patient were suffered with ill-fitting denture due to inaccurate impression in conventional overdenture condition. The oral rehabilitation was completed with placing 2 implants as proper anchor.

Maxillary complete denture rehabilitation in flabby tissue patient fabricated by no-pressure impression technique with individual tray replicated treatment denture through 3D printing: A case report (3D 프린팅으로 치료 의치를 복제한 개인 트레이를 이용한 무압 인상을 통해 제작한 flabby tissue 환자의 상악 총의치 수복 증례)

  • Hong, Jun-Pyo;Bae, Jung-Yoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.3
    • /
    • pp.246-253
    • /
    • 2022
  • Flabby tissue is not rare for denture wearers. Mucostatic impression technique is necessary due to compromised retention and stability of denture resulting from distortion of mobile flabby tissue. In this report, individual tray was fabricated by model-scanning and 3D printing treatment denture. And then, mucostatic impression for flabby tissue was obtained by using individual tray modified with window technique. Definitive denture was fabricated based on information of treatment denture including incisal pontic arrangement, jaw relationship and occlusion.

Comparative accuracy of new implant impression technique using abutments as impression copings with an angulated implant model (경사지게 식립된 임플랜트 모형에서 지대주를 인상용 코핑으로 이용한 새로운 인상법의 정확성 비교 연구)

  • Lee, Hyeok-Jae;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.201-208
    • /
    • 2008
  • Statement of problem: A new implant impression technique which use abutments as impression coping, and use resin cement as a splinting material was described. Accuracy of this technique was compared with conventional closed tray and resin splinted open tray technique for a $15^{\circ}$ angled 3-implant model Material and methods: A dental stone master model with 3 linearly positioned implant analogue and a reference framework which was passively fitted to it were fabricated. The center analogue was perpendicular to the plane of model and the outer analogues had a $15^{\circ}$angulation forward or backward. 10 closed tray impressions, 10 resin splinted open tray impressions, 10 abutment-resin framework cementation impressions and 10 abutment-metal framework cementation impressions were made with additional silicone material and poured with dental stone. A light microscope with image processing was used to record the vertical gap dimension between reference framework and analogue of duplicated cast made with each 4 impression techniques. Statistical analysis used one-way ANOVA with post-hoc tests Tukey test of .05 level of significance Results: Significant difference in the vertical gap dimension was found between closed tray technique; 74.3 (${\pm}33.4$)${\mu}m$ and resin splinted open tray technique, and two other new technique. (P<.05) Abutment-metal framework cementation technique;42.5 (${\pm}11.9$)${\mu}m$ was significantly different from resin splinted open tray technique. (P<.05) Abutmentresin framework cementation technique;51.0 (${\pm}14.1$)${\mu}m$ did not differ significantly from resin splinted open tray technique;50.3 (${\pm}16.9$)${\mu}m$. (P>.05) Conclusion: Within limitations of this study, the accuracy of implant level impressions of resin splinted open tray technique was superior to that of closed tray technique. A new technique using abutment and metal framework cementation was more accurate than resin splinted open tray technique.