• Title/Summary/Keyword: Impression material

Search Result 201, Processing Time 0.022 seconds

THE EFFECT OF ABUTMENT MATERIALS AND SURFACE TREATMENT ON RUBBER BASE IMPRESSION (고무 인상채득시 지대치재료와 표면처리법의 영향)

  • Jeong Do-Jin;Yang Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.2
    • /
    • pp.146-156
    • /
    • 2001
  • The purpose of this study was twofold. One was to evaluate the wettability of 4 elastomeric impression materials on tooth and different kinds of filling materials. The other was to identify the effect of topical surfactants sprayed on the surface of each impression. The elastomeric impression mate rials used in this experimental study were one polyether(Impregum F) and three polyvinyl siloxanes(Provil novo, Zerosil, Imprint). The abutments were prepared for 3/4 crown or onlay on the extracted human first molar. The filling materials used in this study for the duplication of prepared abutment were composite resin, amalgam, and casting metal. Impression was taken by manufacturer's recommendations and the number of voids on the impression surface was counted. The topical surfactants were Spannex $II^{(R)}$ and $Cohere^{(R)}$. The wettability was evaluated by comparing the number of voids between non-treated group and treated groups. The results were as follows : 1. $Zerosil^{(R)}$ showed the least number of voids on the impression surface. The number of voids increased in order of Provil $novo^{(R)}$, Impregum $F^{(R)}$, and $Imprint^{(R)}$. 2. Impregum $F^{(R)}$ and $Zerosil^{(R)}$ showed the least number of voids on the surface of dental stone master cast. The number is inclosed in order of Provil $novo^{(R)}$ and Imprint 3. When abutment material is tooth, the number of voids on the surface of master cast was smallest compared with that of other abutment materials. The number of voids increased in order of casting metal, amalgam and composite resin 4. The number of voids on the surface of the dental stone master cast was smallest when Spannex $II^{(R)}$ was used, followed by $Cohere^{(R)}$ treated group and non-treated group. These results suggest that the difference in wettability caused by the types of rubber base impression materials as well as abutment materials can affect the number of voids. And the use of topical surfactant for rubber base impression materials can improve the wettability of the materials and enhance the accurate master cast which has fewer surface voids.

  • PDF

EFFECT OF CONTAMINANTS ON THE PUTTY-WASH BOND STRENGTH IN TWO-STEP RELINE TECHNIQUE USING VINYL POLYSILOXANE IMPRESSION MATERIALS (Vinyl Polysiloxane 인상재를 이용한 이회 인상법에서 contaminants가 putty-wash 결합력에 미치는 영향)

  • Kim, Mu-Hyon;Jeong, Chang-Mo;Jeon, Young-Chan;Hwang, Hie-Seong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.266-276
    • /
    • 1996
  • Numerous factors are known to affect the accuracy of elastomeric impression materials. Factor often overlooked is the quality of the bond between putty and wash during corrective reline impression technique. The putty-wash bond strength must be strong enough to over-come the local stress at putty-wash interface. It is not always possible to avoid saliva contamination in making corrective wash impres-sion. And putty preliminary impression material con be used as a template for provisional restoration. Human saliva and the residual monomer of autopolymerizing acrylic resin are thought to affect the bond strength and the failure type. This study examined the effect of contaminants like human saliva, and residual resin monomer on the putty-wash bond strength and the effectiveness of treatment. 1. Of the tested three brands of Vinyl Polysiloxane impession meterial, Express Exhibited the greatest bond strength followed by Eamix and Perfect showed the lowest putty-wah bond strength. 2. Coating the putty substrates with human saliva did not produce decreased failure load in all the breands of Vinyl Polysiloxane impression meterail. 3. Of the three brands of VPS impression material that were exposed to methhylmethacry-late resin(Jet), only the putty-wash bond strength of the Perfect group diminished signifi-cantly. Moreover, all the specimens from group C of Perfect exhibited adhesive failure. 4. Exposing the substrates to ethylmethacrylate resin(SNAP. diminished the putty-wash bond strength significantly. With Perfect and Examix, failure occurred cohesively through the light-body, whereas with Express, failure occurred adhesive-cohesively. 5. Removing approximately 1mm thickness of the contaminated putty interface was the most effective treatment in countering the undesirable effect caused by residual resin monomer. The putty-wash bond strength of the groups that were treated with 1mm even putty reduction was not significantly different from those of control groups. With Perfect and Examix, cleaning the specimens with gauze soaked in 70% isopropyl alcohol increased the putty-wash bond strength, but was not as effective as 1mm even reduction of contaminated putty substrates. With Express, 70% isoproryl alcohol treatment exhibi0ted comparable putty-wash bond strength to that of control group.

  • PDF

A Study on Impression Formation According to Design Elements of wedding Dresses and Perceivers Gender(Payt II) -Emphasis on Materials, Sleeves, and Trimmings of wedding Dresses- (웨딩드레스의 디자인 요소와 지각자 성별에 따른 인상형성 연구(제2보) -소재, 소매와 장식유무를 중심으로-)

  • 이미연;이명희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.8
    • /
    • pp.1216-1227
    • /
    • 2002
  • The objective in the part H of this study was to investigate the effects of materials, sleeves, trimming, and perceivers gender on impression formation. Stimuli consisted of 13 color photographs of a female model wearing a wedding dress which were manipulated according to clothing cues. A semantic differential sale of 4 dimensions was used. These were attractiveness, neatness, femininity, and prettiness. Samples were 312 males and females. For the effect of sleeves, there were significant main effects in attractiveness, femininity, neatness, and prettiness. Three-quarters lace ruffled sleeves increased the perception of positive attractiveness, femininity, and prettiness. Flounced sleeves had a positive effect on the perception of neatness. Long-tight sleeves had a negative effect on the perception of attractiveness, femininity, and prettiness. Sleeveless dresses increased the perception of negative neatness. There was an interaction effect between sleeves and the perceivers gender on neatness. For the onぉ of material, there were significant main effects in neatness, femininity, and prettiness. Solid cloth had a positive effect on the perception of neatness and negatively on prettiness. The combination of lace and solid cloth increased the perception of positive femininity and prettiness. lace had a negative effect on the perception of neatness. Satin increased the perception of negative femininity. There was an interaction effect between material and perceivers gender on prettiness. The main effect of trimmings was its effect on prettiness. Ribbons increased the perception of positive prettiness. Not having any trimmings had a negative effect on the perception of prettiness. There was an interaction effect between timings and the perceivers gender on neatness. The results of this study confirm that image perception of wedding dresses becomes different according to the materials, details, and perceiver's gender.

Radiotherapic Valuation of Paraffin Wax for Patients with Oral Cancer (구강암 환자 치료시 치과용 기초상 왁스(Paraffin Wax)의 유용성 평가)

  • Na, Kyoung-Su;Seo, Seuk-Jin;Lee, Je-Hee;Yoo, Sook-Heun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • Purpose: This study is designed to investigate radiotherapic valuation of Paraffin Wax, which is newly formed for this study and generally utilized in dentistry, and Mouth Piece and Putty impression, which are commonly used in radiotherapy, for oral cavity as a compensator. Materials and Methods: Each compensator was formed by $10{\times}10{\times}1cm$ and measured radiation dose attenuation ratio with reference of water phantom which is made of tissue-equivalent materials. Two patients with oral cancer underwent DRR (Digitally Reconstructed Radiogrph) of Offline Review Program of Aria System and Portal vision for 5 times for each material to evaluate reproducibility by each filling materials. Moreover, MU (monitor unit) changes by dose absorption were considered in the case of inevitable implication of an filling materials in the range for radiotherapy. Results: Radiation dose attenuation ratios were shown -0.7~+3.7% for Mouth Piece, +0.21~+0.39% for Paraffin Wax and -2.71~-1.76% for Putty impression. Error ranges of reproducibility of positions were measured ${\pm}3mm$ for Mouth Piece, ${\pm}2mm$ for Paraffin Wax and ${\pm}2mm$ mm for Putty impression. Difference of prescription MU from dose absorption with an filling material increased +7.8% (250 MU) in Putty impression and -0.9% (230 MU) in Paraffin Wax as converted into a percentage from the standard phantom, Water 232 MU. Conclusion: Dose reduction of boundary between cavity and tissue was observed for Mouth Piece. Mouth Piece also had low reproducibility of positions as it had no reflection of anatomy of oral cavity even though it was a proper material to separate Maxilla and Mandible during therapy. On the other hand, Putty impression was a suitable material to correctly re-position oral cavity as before. However, it risked normal tissues getting unnecessary over irradiation and it caused radiation dose decrease by -2.5% for 1cm volume in comparison of it of water phantom. Dose reduction in Paraffin Wax, Fat Tissue-Equivalent Material, was smaller than other impressions and position reproducibility of it was remarkable as it was possible to make an anatomy reflected impression. It was also well fitted to oral cavity to transfer radiation dose planned in radiotherapy. Thus, Paraffin Wax will be an ideal material in radiotherapy for patients with oral cancer.

  • PDF

Accuracy of a proposed implant impression technique using abutments and metal framework

  • Lee, Hyeok-Jae;Lim, Young-Jun;Kim, Chang-Whe;Choi, Jung-Han;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.1
    • /
    • pp.25-31
    • /
    • 2010
  • PURPOSE. This study compared the accuracy of an abutment-framework (A-F) taken with open tray impression technique combining cement-on crown abutments, a metal framework and resin cement to closed tray and resin-splinted open tray impression techniques for the 3-implant definitive casts. The effect of angulation on the accuracy of these 3 techniques was also evaluated. MATERIAL AND METHODS. Three definitive casts, each with 3 linearly positioned implant analogs at relative angulations 0, 30, and 40 degrees, were fabricated with passively fitted corresponding reference frameworks. Ten impressions were made and poured, using each of the 3 techniques on each of the 3 definitive casts. To record the vertical gap between reference frameworks and analogs in duplicate casts, a light microscope with image processing was used. Data were analyzed by two-way analysis of variance and the Tukey test. RESULTS. The open tray techniques showed significantly smaller vertical gaps compare to closed tray technique (P < .05). The closed tray and the resin-splinted open tray technique showed significantly different vertical gaps according to the angulation of implant (P < .05), but the A-F impression technique did not (P > .05). CONCLUSION. The accuracy of the A-F impression technique was superior to that of conventional techniques, and was not affected by the angulation of the implants.

A STUDY ON THE TENSILE BOND STRENGTH BETWEEN VARIOUS RESIN TRAY MATERIALS AND RUBBER IMPRESSION MATERIALS (수종의 트레이 레진과 고무 인상재간의 인장 접착강도에 관한 연구)

  • Song Kyung-Won;Lim Ju-Hwan;Cho In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.4
    • /
    • pp.351-365
    • /
    • 2001
  • For accurate impression taking, accurate impression material, solid individual tray, and bond strength between impression materials and resin tray are important factors. The purpose of this study was to evaluate tensile bond strength of rubber impression materials to various tray resin materials. This study tested the time dependent tensile bond strength between commercial brands or poly ether, polysulfide, additional silicone impression materials and commercial brands of self curing tray resin. light activited tray resin when applying adhesive Resin specimens were made with 20mm in diameter, 2mm in thickness. 1 made total 360 specimens, 10 per each group and the tensile bond strength was measured by using the Instron($M100EC^{(R)}$, Mecmesin Co., England). The results were as follows ; Comparisons of various impression materials. 1. In case of Impregum $F^{(R)}$, the bond strength of tray resin was decreased in order of SR $Ivolen^{(R)}$, Ostron $100^{(R)}$ Instant tray $mix^{(R)}$, $Lightplast^{(R)}$. All groups excluding Ostron $100^{(R)}$, Instant tray $mix^{(R)}$ are significant difference (p<0.05). Drying time after applying adhesive, the tensile bond strength of tray resin was insignificantly decreased in order of 10 min drying time group. 1 min drying time group. 5 min drying time group. 2. In case of Permlastic $regular^{(R)}$ the bond strength of tray resin was insignificantly decreased in order of Ostron $100^{(R)}$. SR $Ivolen^{(R)}$, Instant tray $mix^{(R)}$ $Lightplast^{(R)}$. About drying time after applying adhesive, the tensile bond strength of tray resin was significantly decreased in order of 5 min drying time group, 10 min drying time group, 1 min drying time group(p<0.05). 3. In case of Exaflex $regular^{(R)}$. the bond strength of tray resin was decreased in order of $Lightplast^{(R)}$, SR $Ivolen^{(R)}$, Instant tray $mix^{(R)}$, Ostron $100^{(R)}$. $Lightplast^{(R)}$ was significant difference(p<0.05). About drying time after applying adhesive, the tensile bond strength of tray resin was decreased in order of 5 min drying time group, 10 min drying time group, 1 min drying time group(p<0.05). Especially 5 min ding time group was significant difference(p<0.05). According to the results of this study, we can see the greatest tensile bond strength when using Impregrm $F^{(R)}$ and Permlastic $regular^{(R)}$ with self curing tray resin, when using Exaflex $regular^{(R)}$ with light activated tray resin In my opinion, adhesive should be dried more than 5 min before impression taking to achieve the greatest tensile bond strength.

  • PDF

Effect of interproximal undercut on the dimensional accuracy of impression (치간 유두 소실로 인한 언더컷이 인상체의 체적 정확도에 미치는 영향)

  • Lee, Ju-Ri;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.330-336
    • /
    • 2015
  • Purpose: This study evaluated the effect of loss of interproximal papilla, creating an undercut, on the accuracy of impression materials. Materials and methods: Two addition type silicone impression materials ($Extrude^{(R)}$ Speed Wash, $Imprint^{TM}$ II Quick Step Light Body) and one alginate impression material (Cavex Impressional) were used to make impressions of a maxillary master model simulating clinical conditions with or without interproximal papilla. Stone was poured in the impressions and working casts were fabricated. A total of 6 groups with 6 working casts in each group were scanned using 3-dimensional optical scanner. The accuracy of the impressions was assessed by measuring the dimensional changes (${\Delta}I$ (%)) of 6 distances on working casts compared to a master model with a 3-dimensional digitizing and inspection software. The data were analyzed by two-way ANOVA (P<.05). Results: Three of 6 distances showed statistically significant differences among the impression materials. Only 1 of 6 distances in alginate impression showed a statistically significant difference between casts with and without interproximal papilla (P=.047). Conclusion: The presence of undercut due to loss of interproximal papilla did not significantly influence the dimensional accuracy of addition type silicone and alginate impression materials.

DIMENSIONAL ACCURACY OF EPOXY RESINS AND THEIR COMPATIBILITY WITH IMPRESSION MATERIALS (EPOXY RESIN의 정확도와 인상재와의 친화성에 관한 연구)

  • Chang, Su-Kyoung;Chang, Ik-Tae;Yim, Soon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.3
    • /
    • pp.383-394
    • /
    • 1999
  • The indirect technique for making cast restoration requires that dies be as accurate and durable as possible. Currently, stone is the most commonly used material for die. However, it has some problems such as the weakness in its strength and low abrasion resistance. Recently, epoxy resin die systems have become available. The purpose of this study was to examine two commercially available resin die systems and evaluate some characteristics for their clinical performance. This study evaluated the dimensional accuracy of epoxy resins and their wettability with impression materials. In this study, the first experiment was about dimensional accuracy of different die materials. The master model was made of stainless steel. 10 models were made of two epoxy resins (Die-epoxy, Tri-epoxy) and a die stone (Fujirock) each. Occlusal diameter (Dimension I), occluso-gingival height (Dimension II), and interabutment distance (Dimension III) were measured in each model. Next, the contact angles of die materials with impression materials were observed. The blocks were made of polyether, hydrophilic additional silicone, polysulfide impression materials. By drop-ping the same amount (0.05ml) of Tri-epoxy, Die-epoxy, and die stone on the blocks, 10 samples of each die material were made. After setting of materials, the contact angles were measured. The results of this study were as follows. 1. The expansion of stone die and the shrinkage of resin dies in occlusal diameter were observed, and stone and Tri-epoxy were expanded and Die-epoxy was shrinked in occluso-gingival height. There was little change among materials in interabutment distance (p<0.05). 2. In comparison with the master model Tri-epoxy had the least variation in measurement of the three die systems examined. Die-epoxy was next, and die stone showed the greatest variation. 3. The compatibility of die stone for polyether, hydrophilic additional silicone, polysulfide decreased in order, wherease epoxy materials had the decreased compatibility for polyether and polysulnde, hydrophilic additional silicone in order. It was not statistically different between polyether and polysulfide (p<0.05). 4. The contact angles of Tri-epoxy, Die-epoxy, die stone were getting bigger in order.

  • PDF

A Study on the Evolutionary Aspects of Place Image Strategies through the Marketing Paradigm (마케팅패러다임에 의한 장소이미지 전략의 진화양상 연구)

  • Lee, Young-Soo;Park, Kyoung-Ah
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.1
    • /
    • pp.33-42
    • /
    • 2011
  • This study, by applying the experiential and psychological thought category of "impression" as the space design strategy for drawing out "sensitivity," aims to break down the psychological mechanism forming the image held by the subject, and based on such segmentation, seek and strategize an effective design methodology. The subject's memory, pure sensation, and movement sensation are set as the preceding determinants comprising the psychological mechanism of space impression. The control determinants for achieving activation of psychological effect are reinterpreted as the relations of memory-cognition, sensation-perception, and movement-sensation and categorized into a cognitive strategy based on association, metaphor and remembrance; a direct sensation strategy based on formation, superposition and transposition of sensation; and a sensation strategy of process-formation based on expectation organization and reversal, contraction and relaxation. Each strategy is achieved through the formal, material and structural control of architecture. As a restructuring of the design methodology that has been experientially applied, the strategy categorization is important in that, by presenting the usefulness and effect by strategy according to space experience, it makes concrete the basic data that are useful for designing experience of sensitivity.

Implant prosthesis using intraoral scanner: Case Report (구강스캐너를 이용한 임플란트 보철물 제작 증례)

  • Kang, Byeong-Gil;Kim, Hee-Jung;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.256-261
    • /
    • 2015
  • Accuracy is the most important thing in implant prosthesis, for this reason it is essential procedure to check the accuracy of impression taking. However, impression material has its own error and the error occurs in model-making procedure. As an alternative way to this, using intraoral scanner can be suggested and many studies were issued reporting that there's no statistically significant difference in accuracy between intraoral scanner and conventional impression. Therefore, the purpose of this study is to report the process of making of implant prosthesis using intraoral scanner, which is more convenient, fast, accurate compared with conventional method.