• Title/Summary/Keyword: Implementation Phase

Search Result 1,255, Processing Time 0.028 seconds

A Study on the Implementation of Exciter in VHF Band (VHF대역 Exciter 구성에 관한 연구)

  • 박순준;황경호;박영철;정창경;차균현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.13 no.3
    • /
    • pp.239-254
    • /
    • 1988
  • In this paper an exciter which performs modulation and amplification is composed of high power(30dBm) VCO(Voltage Controlled Oscillator) using push-pull circuit. Modulation is FSK using PLL(Phase Locked Loop). A single loop PLL synthesizer having sequency range of 42.5-100.5MHz, 25KHz channel spacing and switching time of 1msec converts down the exciter VCO frequency to 1.25MHz. This signal mixed with the FSK modulated signal coming in the phase detector of exciter. The acquisition time of exciter for frequency hoppng is less than 200usec, so the total acquisition time for transmission is less that 1.5msec. There is no need of additional power amplification because power amlifiction by high power VCO is high enough to communicate within near distance. The proposed frequency synthesizer is not complex so it is suitable for low cost slow frequency hopping spread spectrum communication.

  • PDF

Implementation of a 35KVA Converter Base on the 3-Phase 4-Wire STATCOMs for Medium Voltage Unbalanced Systems

  • Karimi, Mohammad Hadi;Zamani, Hassan;Kanzi, Khalil;Farahani, Qasem Vasheghani
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.877-883
    • /
    • 2013
  • This paper discussed a transformer-less shunt static synchronous compensator (STATCOM) with consideration of the following aspects: fast compensation of the reactive power, harmonic cancelation and reducing the unbalancing of the 3-phase source side currents. The STATCOM control algorithm is based on the theory of instantaneous reactive power (P-Q theory). A self charging technique is proposed to regulate the dc capacitor voltage at a desired level with the use of a PI controller. In order to regulate the DC link voltage, an off-line Genetic Algorithm (GA) is used to tune the coefficients of the PI controller. This algorithm arranged these coefficients while considering the importance of three factors in the DC link voltage response: overshoot, settling time and rising time. For this investigation, the entire system including the STATCOM, network, harmonics and unbalancing load are simulated in MATLAB/SIMULINK. After that, a 35KVA STATCOM laboratory setup test including two parallel converter modules is designed and the control algorithm is executed on a TMS320F2812 controller platform.

Risk Analysis and Classification of Public-Private Partenership in Project Financing Process (민관합동형 PF사업의 단계별 리스크 분류 및 위험도분석)

  • Park, Hye-Sung;Kim, Sun-Kuk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.5
    • /
    • pp.117-126
    • /
    • 2011
  • With Public-private partnership PF (project financing) deals saw explosive increase in quantity since its introduction to Korea in 2001, but, met with severe recession in the fallouts of the financial crisis that hit the global economy in 2008. This study intends to identify the risk factors corresponding to issues of public-private partnership projects financing structure and classify and analyze them by project phase. Outcomes of this research are expected to help recognize risk factors in each project phase during project planning and develop risk control and mitigation strategy during project implementation.

Implementation and Design of a Fuzzy Power System Stabilizer Using an Adaptive Evolutionary Algorithm

  • Hwang, Gi-Hyun;Lee, Min-Jung;Park, June-Ho;Kim, Gil-Jung
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.4
    • /
    • pp.181-190
    • /
    • 2003
  • This paper presents the design of a fuzzy power system stabilizer (FPSS) using an adaptive evolutionary algorithm (AEA). AEA consists of genetic algorithm (GA) for a global search capability and evolution strategy (ES) for a local search in an adaptive manner when the present generation evolves into the next generation. AEA is used to optimize the membership functions and scaling factors of the FPSS. To evaluate the usefulness of the FPSS, we applied it to a single-machine infinite bus system (SIBS) and a power system simulator at the Korea Electrotechnology Research Institute. The FPSS displays better control performance than the conventional power system stabilizer (CPSS) for a three-phase fault in heavy load, which is used when tuning FPSS. To show the robustness of the FPSS, it is applied with disturbances such as change of mechanical torque and three-phase fault in nominal and heavy load, etc. The FPSS also demonstrates better robustness than the CPSS. Experimental results indicate that the FPSS has good system damping under various disturbances such as one-line to ground faults, line parameter changes, transformer tap changes, etc.

Training Requirements for Control Room Operators of an Advanced Nuclear Power Plant

  • Park, Hong Joon;Park, Geun Ok;Kim, Sa Kil;Byun, Seong Nam
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.107-115
    • /
    • 2013
  • Objective: The aim of this study is to identify the training requirements of new nuclear power plant by a comprehensive literature review. Background: The design of instrumental and control systems for New NPP is applied fully digitalized systems. For example, soft-control, large display panels(LDP), and an advanced alarm system were applied to the APR-1400 or SMART. Method: The NUREG-0711 and international guideline of training program was analyzed from the following four phases of SAT(Systemic Approach to Training): Analysis, Design, Development, Implementation and Evaluation. Results: To identify the requirement of training program, 'Feedback' phase was considered and each phase of SAT was classified. Conclusion: A more systematic requirement of training program is needed which considers the computerized system was applied to the new NPP. Application: The results of the publishing can be useful for standardization of the systematic training program for the operators of NPP.

The Implementation of the Compensation Algorithm of Time Delay for Microwave Polar Transmitters (마이크로파 폴라 송신기의 시간지연 보상 알고리즘 구현)

  • Kim, Min-Soo;Lee, Kun-Joon;Rhee, Young-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.9
    • /
    • pp.790-797
    • /
    • 2015
  • In this paper, We made the microwave polar transmitter based on the software to analyze the synchronization status between the phase signal and the amplitude signal of polar transmitter, and analyzed the result. In order to solve the time delay mismatch problem, we applied simplified compensation algorithm and compared the synchronization status between the two paths before and after compensation. Before compensation, the value of time delay mismatch was the maximum of 97 nsec at 9.3 GHz with the occupied bandwidth of 12 MHz, but after applying the compensation algorithm, the signals between the two paths were synchronized, and we identified the occupied bandwidth could recover to the previous 3.7 MHz.

Finite Element Analysis of Partially Saturated Soil Considering Pore-air Pressure (간극공기압을 고려하는 불포화토의 유한요소해석)

  • Kim, Jae-Hong;Hwang, Young-Cheol
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.3
    • /
    • pp.95-102
    • /
    • 2011
  • A model of solid-water-air coupling in triphasic mixture is compared to that of solid-water coupling in biphasic mixture with an application to partially saturated soils. Based on thermodynamics, the mathematical framework governing the behavior of a partially saturated soil is derived by using balance equations, and numerical implementation through drainage experiment of a sand column is carried out to validate the obtained formulations. The role of the air phase in the hydro-mechanical behavior of triphasic mixture can be analyzed from the interaction among phases and from the solid skeleton's constitutive behavior, and the three-phase model found applications in geotechnical engineering problems, such as $CO_2$ sequestration and air storage in an aquifer.

Implementation of Soft-starter with Large Scale Power Stack for High Voltage Induction Motor Driving (고압 유도전동기의 구동을 위한 소프트-스타터의 대용량 파워스텍 구현)

  • Ryu, Doo-young;Jeon, Hee-jong;Shon, Jin-geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.2
    • /
    • pp.88-93
    • /
    • 2016
  • Soft starters are used with large induction motors in blowers, fans, pumps and the crane hoist drives. AC voltage controllers are used as soft starters in induction motors for starting and to adjust its speed. Soft-starter starting system uses phase control method of input electric source through the setting of the thyristor(SCR) firing angle ${\alpha}$, and it can control input electric source stably and continuously from beginning of starting to ending of starting. In this paper, it is verified that power stack of high-voltage with SCR series system possesses dielectric strength and input electric source is controlled stably by phase control. Especially, from the driving experimental of proposed soft-starter operating, a smoothing acceleration and inrush current decrease can be achieved by the series SCR trigger.

Implementation of the Smart Emergency Medical System (스마트 응급의료 시스템 구현)

  • Park, Hong-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.4
    • /
    • pp.646-654
    • /
    • 2011
  • Recently, the task in which the number of people of the emergency medical technician whom it boards the ambulance is unreasonably insufficient and in which the fire fighter one person gets in the ambulance and which transfers the patient comes into question often. When the emergency patient is generated, it has to transfer to the special hospital in which above anything else, the measure which is quick and exact is needed and where there is the medical device which is suitable for particularly, the patient. This paper implementations the emergency medical system by the smart phone. The implemented system monitors the heart beat of the patient the monitoring among the patient transport with the real-time type. It can grasp the medical history information of the patient, and etc. in the past. And the system provides the emergency hospital which the patient requires and the pre-hospital phase provides the environment in which the disposition which is quick and efficient is possible to the emergency patient.

Efficient DFDC Filter Design Using Interpolated Fourth-Order Polynomials (IFOP를 사용한 효과적인 DFDC 필터 설계)

  • 양세정;장영범
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.6C
    • /
    • pp.609-614
    • /
    • 2003
  • In this paper, a new filter structure to improve frequency response characteristics in CIC(Cascaded Integrator-Comb) decimation filters is proposed. Conventional filters improve passband characteristics, but they make worse aliasing band characteristics. In this paper, we propose a new filter which is called IFOP(Interpolated Fourth-Order Polynomials). By using this proposed filter, passband droop and aliasing band attenuation are simultaneously improved. Since proposed filter needs only one multiplication, computation is not much. And overall linear phase characteristics are maintained since the proposed filter is also linear phase. Finally, implementation cost of the proposed filter is compared with those of conventional filters.