• 제목/요약/키워드: Implantitis

검색결과 141건 처리시간 0.023초

A retrospective study of the long-term survival of RESTORE® dental implants with resorbable blast media surface

  • Keun-Soo Ryoo;Pil-Jong Kim;Sungtae Kim;Young-Dan Cho;Young Ku
    • Journal of Periodontal and Implant Science
    • /
    • 제53권6호
    • /
    • pp.444-452
    • /
    • 2023
  • Purpose: The aim of this study was to retrospectively evaluate the survival and failure rates of RESTORE® implants over a follow-up period of 10-15 years at a university dental hospital and to investigate the factors affecting the survival rate of these dental implants. Methods: A total of 247 RESTORE® dental implants with a resorbable blast media (RBM) surface inserted in 86 patients between March 2006 and April 2011 at the Department of Periodontology of Seoul National University Dental Hospital were included. Patients with follow-up periods of less than 10 years were excluded, and data analysis was conducted based on dental records and radiographs. Results: Over a 10- to 15-year period, the cumulative survival rate of the implants was 92.5%. Seventeen implants (6.88%) were explanted due to implant fracture (n=10, 4.05%), peri-implantitis (n=6, 2.43%), and screw fracture (n=1, 0.4%). The results of univariate regression analysis using a Cox proportional hazards model demonstrated that implants placed in male patients (hazard ratio [HR], 4.542; 95% confidence interval [CI], 1.305-15.807; P=0.017) and implants that supported removable prostheses (HR, 15.498; 95% CI, 3.105-77.357; P=0.001) showed statistically significant associations with implant failure. Conclusions: Within the limitations of this retrospective study, the RESTORE® dental implant with an RBM surface has a favorable survival rate with stable clinical outcomes.

Preparation and Performance Evaluation of a Zinc Oxide-Graphene Oxideloaded Chitosan-Based Thermosensitive Gel

  • Hao Huang;Rui Han;Ping-Ping Huang;Chuan-Yue Qiao;Shuang Bian;Han Xiao;Lei Ma
    • Journal of Microbiology and Biotechnology
    • /
    • 제34권6호
    • /
    • pp.1229-1238
    • /
    • 2024
  • This study aimed to develop and assess a chitosan biomedical antibacterial gel ZincOxide-GrapheneOxide/Chitosan/β-Glycerophosphate (ZnO-GO/CS/β-GP) loaded with nano-zinc oxide (ZnO) and graphene oxide (GO), known for its potent antibacterial properties, biocompatibility, and sustained drug release. ZnO nanoparticles (ZnO-NPs) were modified and integrated with GO sheets to create 1% and 3% ZnO-GO/CS/β-GP thermo-sensitive hydrogels based on ZnO-GO to Chitosan (CS) mass ratio. Gelation time, pH, structural changes, and microscopic morphology were evaluated. The hydrogel's antibacterial efficacy against Porphyromonas gingivalis, biofilm biomass, and metabolic activity was examined alongside its impact (MC3T3-e1). The findings of this study revealed that both hydrogel formulations exhibited temperature sensitivity, maintaining a neutral pH. The ZnO-GO/CS/β-GP formulation effectively inhibited P. gingivalis bacterial activity and biofilm formation, with a 3% ZnO-GO/CS/β-GP antibacterial rate approaching 100%. MC3T3-e1 cells displayed good biocompatibility when cultured in the hydrogel extract.The ZnO-GO/CS/β-GP thermo-sensitive hydrogel demonstrates favorable physical and chemical properties, effectively preventing P. gingivalis biofilm formation. It exhibits promising biocompatibility, suggesting its potential as an adjuvant therapy for managing and preventing peri-implantitis, subject to further clinical investigations.

파노라마방사선사진 지수와 임플란트 실패와의 관계에 관한 연구 (The relationships between panoramic indices and dental implant failure)

  • 조현정;이원진;허민석;안창현;이진구;이삼선;최순철
    • Imaging Science in Dentistry
    • /
    • 제34권1호
    • /
    • pp.25-30
    • /
    • 2004
  • Purpose: Several panoramic indices have been suggested to assess bone quality from the morphology and width of mandibular cortex on panoramic radiography. The purpose of this study was to compare dental implant failure group with control group in panoramic mandibular index (PMI), mandibular cortical index (MCI), and gonion index (GI) and to determine the effect of these panoramic indices on dental implant failure. Materials and Methods: A case-control study was designed. Test group (n=42) consisted of the patients who had their implants extracted because of peri-implantitis. Control group (n=139) consisted of the patients who retained their implants over one year without any pathologic changes and had been followed up periodically. They had dental implants installed in their mandibles without bone augmentation surgery from 1991 to 2001. The following measures were collected for each patients: 1) PMI, MCI, and GI were measured twice at one-week interval on preoperative panoramic views; and 2) age, sex, implant length, implant type, installed location, occluding dentition state, and complication were investigated from the chart record. Results: The PMI showed moderate level of repeatability. The intra-observer agreement of MCI and GI were good. There was statistically significant difference in PMI between two groups. There were significant different patterns of distribution of MCI and GI between two groups. Among the panoramic indices, PMI and MCI showed significant correlation with dental implant failure. Conclusion: Panoramic indices can be used as reference data in estimating bone quality of edentulous patients who are to have implants installed in their mandibles.

  • PDF

Comparative evaluation of roughness of titanium surfaces treated by different hygiene instruments

  • Unursaikhan, Otgonbayar;Lee, Jung-Seok;Cha, Jae-Kook;Park, Jung-Chul;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제42권3호
    • /
    • pp.88-94
    • /
    • 2012
  • Purpose: The use of appropriate instruments to clean surfaces with minimal change, is critical for the successful maintenance of a dental implant. However, there is no consensus about the type and methodology for such instruments. The aim of this study was to characterize changes in the roughness of titanium surfaces treated by various scaling instruments. Methods: Thirty-seven identical disks (5 mm in diameter) were investigated in this study. The specimens were divided into eight groups according to the types of instrumentation and the angle of application. Ultrasonic scaling systems were applied on a titanium disk to simulate standard clinical conditions. The equipment included a piezoelectric ultrasonic scaler with a newly developed metallic tip (NS group), a piezoelectric ultrasonic scaler with a conventional tip (CS group), a piezoelectric root planer ultrasonic scaler with a conventional tip (PR group), and a plastic hand curette (PH group). In addition, the sites treated using piezoelectric ultrasonic scaler systems were divided two sub-groups: 15 and 45 degrees. The treated titanium surfaces were observed by scanning electron microscopy (SEM), and the average surface roughness (Ra) and mean roughness profile depth (Rz) were measured with a profilometer. Results: SEM no significant changes in the titanium surfaces in the NS group, regardless of the angle of application. The PH group also showed no marked changes to the titanium surface, although some smoothening was observed. All CS and PR sites lost their original texture and showed irregular surfaces in SEM analysis. The profilometer analysis demonstrated that the roughness values (Ra and Rz) of the titanium surfaces increased in all, except the PH and NS groups, which showed roughness decreases relative to the untreated control group. The Ra value differed significantly between the NS and PR groups (P<0.05). Conclusions: The results of this study indicated that changes in or damage to titanium surfaces might be more affected by the hardness of the scaler tip than by the application method. Within the limitations of this study, the newly developed metallic scaler tip might be especially suitable for peri-implant surface decontamination, due to its limited effects on the titanium surface.

Substrate roughness induces the development of defective E-cadherin junctions in human gingival keratinocytes

  • Jin, Chengbiao;Lee, Gayoung;Oh, Changseok;Kim, Hyun Jung;Kim, Hyun-Man
    • Journal of Periodontal and Implant Science
    • /
    • 제47권2호
    • /
    • pp.116-131
    • /
    • 2017
  • Purpose: The entry of bacteria or harmful substances through the epithelial seal of human gingival keratinocytes (HGKs) in the junctional epithelium (JE) is blocked by specialized intercellular junctions such as E-cadherin junctions (ECJs). However, the influence of roughened substrates, which may occur due to apical migration of the JE, root planing, or peri-implantitis, on the development of the ECJs of HGKs remains largely unknown. Methods: HGKs were cultured on substrates with varying levels of roughness, which were prepared by rubbing hydrophobic polystyrene dishes with silicon carbide papers. The activity of c-Jun N-terminal kinase (JNK) was inhibited with SP600125 or by transfection with JNK short hairpin RNA. The development of intercellular junctions was analyzed using scanning electron microscopy or confocal laser scanning microscopy after immunohistochemical staining of the cells for E-cadherin. The expression level of phospho-JNK was assessed by immunoblotting. Results: HGKs developed tight intercellular junctions devoid of wide intercellular gaps on smooth substrates and on rough substrates with low-nanometer dimensions (average roughness $[Ra]=121.3{\pm}13.4nm$), although the ECJs of HGKs on rough substrates with low-nanometer dimensions developed later than those of HGKs on smooth substrates. In contrast, HGKs developed short intercellular junctions with wide intercellular gaps on rough substrates with mid- or high-nanometer dimensions ($Ra=505.3{\pm}115.3nm$, $867.0{\pm}168.6nm$). Notably, the stability of the ECJs was low on the rough substrates, as demonstrated by the rapid destruction of the cell junction following calcium depletion. Inhibition of JNK activity promoted ECJ development in HGKs. JNK was closely associated with cortical actin in the regulation of ECJs in HGKs. Conclusions: These results indicate that on rough substrates with nanometer dimensions, the ECJs of HGKs develop slowly or defectively, and that this effect can be reversed by inhibiting JNK.

법랑기질유도체를 도포한 타이태늄 표면에서 조골세포의 증식 및 분화 (Effects of enamel matrix derivative and titanium on the proliferation and differentiation of osteoblasts)

  • 박상현;이인경;양승민;신승윤;이용무;구영;류인철;정종평;한수부;최상묵
    • Journal of Periodontal and Implant Science
    • /
    • 제33권3호
    • /
    • pp.359-372
    • /
    • 2003
  • Among objectives of periodontal therapy. the principal one is the morphological and functional reconstruction of lost periodontal supporting tissues. This includes de novo formation of connective tissue attachment and the regrowth of alveolar bone. The use of enamel matrix derivative(EMD) may be a suitable means of regeneration new periodontal attachment in the infrabony defects. Implant used to replace lost tooth but, implantitis occurred after installation. The purpose of this study was to investigate the effects of EMD on differentiation and growth of osteoblast in titanium disc. Twentyfive millimeter diameter and 1mm thick Ti disc which was coated 25, 50, 100, 200${\mu}g$/ml of EMD(Emdogain(R)) used as experimental group, 25, 50, 100, 200ng/d of rhBMP-2 as positive control group, and no coat as negative control group. A human osteosarcoma cell line Saos-2 was cultured in Ti disc and cell proliferation and Alkaline phosphatase (ALP) activity were measured at 1 and 6 days. PCR was performed at 2 and 8 hours. Semi-quantitative RT-PCR for mRNA expressions of various osteoblastic differentiation markers -type I collagen, ALP, osteopontin, and bone sialoprotein - were performed at appropriate concentrations based upon the results of MTT and ALP assay. Cultured cell-disc complexes were prepared for scanning electron microscopy (SEM) at 2 hour. Data were analyzed using Mann-Whitney and repeated- measures 1-way analysis of variance(SPSS software version 10,SPSS. Chicago. IL). After culture, there was more osteoblast in EMD100${\mu}g$/ml than in EMD50, 200${\mu}g$/ml on day 6. There was significant difference in experimental and positive control group compared control group, as times go by(1 and 6 days). Alkaline phosphatase activity was different significantly in EMD100, 200${\mu}g$/ml and BMP100, 200${\mu}g$/ml on day 6. The results of reverse transcriptase-polymerase chain reaction (RT-PCR) showed that expression of mRNA for ALPase, collagen type I, osteopontin. hone sialoprotein and BMP-2 was detected at 2 hour and 8 hour in EMI 200${\mu}g$/ml subgroup and BMP100ng/ml subgroup. The results of this study suggest that application of enamel matrix derivative on osteoblast attached to titanium surface facilitate the expression of bone specific protein and the differentiation and growth of osteoblast.

RBM 처리된 임플란트 표면의 인공치태 제거 효과 연구 (COMPARATIVE STUDY OF REMOVAL EFFECT ON ARTIFICIAL PLAQUE FROM RBM TREATED IMPLANT)

  • 박재완;국민석;박홍주;;최충호;홍석진;오희균
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제29권4호
    • /
    • pp.309-320
    • /
    • 2007
  • Purpose: This study was to evaluate the removal effect on artificial plaque from RBM treated implant surfaces that are exposed due to peri-implantitis. Materials and methods: Artificial plaque with Streptococcus mutans and acquired pellicle adhered to RBM treated implant discs. Study materials divided into one control and six test groups. In test groups, physical and chemical methods used to remove plaques. Prophyflex, Professional Mechanical Tooth Cleaning (PMTC) and interdental brush as mechanical treatments and 0.1% Chlorhexidine, Citric acid, HCl tetracycline as a chemical treatment were used. To analyses the study, disc weight was measured for remaining plaque quantities and SEM(Scanning Electronic Microscope) findings was taken for evaluation of surfaces. Results: 1. In weight changes, there was significant difference between each treatment group and the control group (p<0.05). Therefore all treatment methods using this study have good ability for remove plaques. 2. In weight changes, there was no significant difference between mechanical and chemical group, and there were no significant differences between each groups (p>0.05). 3. SEM findings after mechanical treatment disclosed as follows; Prophyflex group looked like sound implant surface, and there were some paste on implant surface at PMTC group, and there were some artificial plaque at interdental brush group. 4. SEM findings after chemical treatment disclosed as follows; there were some dark lesions which were supposed as the product from Streptococcus mutans at Chlorhexidine, Citric acid and HCl tetracycline groups. Conclusion: All six methods using in this study have good ability to remove artificial plaque on RBM treated implant. According to SEM findings, prophyflex is a superior method for removing of dental plaque among test groups.

분층피부와 분말골로 이식 전 처리된 유리견갑골근피판과 임플란트 보철을 이용한 경구개와 상악골의 기능적 재건 (FUNCTIONAL RECONSTRUCTION OF DENTO-PALATAL AND MAXILLARY DEFECT USING STAGED OPERATION OF PREFABRICATED SCAPULAR FREE FLAP AND DENTAL IMPLANTS)

  • 이종호;김명진;박종철;김영수;안강민;팽준영;김성민;명훈;황순정;서병무;최진영;정필훈
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권4호
    • /
    • pp.301-307
    • /
    • 2004
  • The flap considered at first for the reconstruction of large maxillary defect, especially mid-face defect, is scapular free flap, because it provides ample composite tissue which can be designed 3-dimensionally for orbital, facial and oral reconstruction. In case of maxillary defect involving hard palate, however, this flap has some limitations. First, its bulk prevents oral function and physio-anatomic reconstruction of nasal and oral cavity. Second, mobility and thickness of cutaneous paddle covering the alveolar area reduce retention of tissue-supported denture and give rise to peri-implantitis when implant is installed. Third, lateral border of scapula that is to reconstruct maxillary arch and hold implants is straight, not U-shaped maxillary arch form. To overcome these problems, new concept of step prefabrication technique was provided to a 27-year-old male patient who had been suffering from a complete hard palate and maxillary alveolar ridge defect. In the first stage, scapular osteomuscular flap was elevated, tailored to fit the maxillary defect, particulated autologous bone was placed subperiosteally to simulate U-shaped alveolar process, and then wrapped up with split thickness skin graft(STSG, 0.3mm thickness). Two months later, thus prefabricated new flap was elevated and microtransferred to the palato-maxillary defect. After 6 months, 10 implant fixtures were installed along the reconstructed maxillary alveolus, with following final prosthetic rehabilitation. The procedure was very successful and patient is enjoying normal rigid diet and speech.

Comparison of marginal bone loss between internal- and external-connection dental implants in posterior areas without periodontal or peri-implant disease

  • Kim, Dae-Hyun;Kim, Hyun Ju;Kim, Sungtae;Koo, Ki-Tae;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • 제48권2호
    • /
    • pp.103-113
    • /
    • 2018
  • Purpose: The purpose of this retrospective study with 4-12 years of follow-up was to compare the marginal bone loss (MBL) between external-connection (EC) and internal-connection (IC) dental implants in posterior areas without periodontal or peri-implant disease on the adjacent teeth or implants. Additional factors influencing MBL were also evaluated. Methods: This retrospective study was performed using dental records and radiographic data obtained from patients who had undergone dental implant treatment in the posterior area from March 2006 to March 2007. All the implants that were included had follow-up periods of more than 4 years after loading and satisfied the implant success criteria, without any peri-implant or periodontal disease on the adjacent implants or teeth. They were divided into 2 groups: EC and IC. Subgroup comparisons were conducted according to splinting and the use of cement in the restorations. A statistical analysis was performed using the Mann-Whitney U test for comparisons between 2 groups and the Kruskal-Wallis test for comparisons among more than 2 groups. Results: A total of 355 implants in 170 patients (206 EC and 149 IC) fulfilled the inclusion criteria and were analyzed in this study. The mean MBL was 0.47 mm and 0.15 mm in the EC and IC implants, respectively, which was a statistically significant difference (P<0.001). Comparisons according to splinting (MBL of single implants: 0.34 mm, MBL of splinted implants: 0.31 mm, P=0.676) and cement use (MBL of cemented implants: 0.27 mm, MBL of non-cemented implants: 0.35 mm, P=0.178) showed no statistically significant differences in MBL, regardless of the implant connection type. Conclusions: IC implants showed a more favorable bone response regarding MBL in posterior areas without peri-implantitis or periodontal disease.

근단변위판막술과 함께 유리치은이식술을 사용하여 임플란트 주변 각화치은을 증대시킨 2건의 증례 보고 (Free gingival graft in combination with apically positioned flap for establishment of keratinized gingiva around the implants: Report of two cases)

  • 백원선;차재국;이재홍;이중석;정의원
    • 대한치과의사협회지
    • /
    • 제54권4호
    • /
    • pp.296-305
    • /
    • 2016
  • Narrow zone of attached gingiva and shallow vestibule around the implants might contribute to difficulty of cleasing, periimplant mucositis caused by incomplete cleansing and further peri-implantitis. The aim of this case report is to present modification of soft tissue biotype around the implants by free gingival grafts according to timing of surgical intervention and shape of free gingiva. A 44 year-old male patient had a missing area on lower right second molar area with 1 to 2 mm of narrow attached gingiva zone and wanted to be treated by implant placement. In radiographic analysis, there was enough alveolar bone to install an implant, free gingiva from hard palate was grafted following implant placement using double layer flap. The width of attached gingival was increased to 4 to 5mm and well maintained during 5 months of follow up. A 69 year-old female patient also had a missing area on lower right first and second molar area with 1 to 2 mm narrow attached gingiva. Since she had systematically angina pectoris and dental phobia, minimal invasive free gingival graft after implants placement was planned. After 2 months of implant surgery, free gingival graft surgery was performed with healing abutments connection. The grafted gingiva was composed of two strip shaped free gingiva, and they were immobilized by periodontal pack. The width of attached gingival was increased to 4 to 5mm and well maintained during 10 months of follow up. With prosthesis delivery, the patients recovered ideal periodontal environment around implants and masticatory function. In conclusion, periodontal health and masticatory function could be achieved through implant placement and free gingival graft.

  • PDF