• 제목/요약/키워드: Implantable antenna

검색결과 14건 처리시간 0.023초

Miniaturized meander-line dual-band implantable antenna for biotelemetry applications

  • Rajagopal Kangeyan;Madurakavi Karthikeyan
    • ETRI Journal
    • /
    • 제46권3호
    • /
    • pp.413-420
    • /
    • 2024
  • A dual-band bio-implantable compact antenna with a meander-line structure is presented. The proposed meander-line antenna resonates at the industrial, scientific, and medical (2.4 GHz) and wireless medical telemetry (1.4 GHz) bands. The meander-line structure is selected as a radiating patch given its versatile and effective design. With a dimension of only 10 mm × 10 mm × 0.635 mm, the designed antenna is compact. Considering a skin phantom, the proposed antenna was designed, optimized, and simulated. The Rogers RT/duroid 6010 substrate material with high dielectric constant was used to fabricate the meander-line dual-band implantable antenna, which was validated experimentally. The superstrate was made of the same material. Experiments were conducted on skin-mimicking gel. The designed meander-line antenna has a high peak gain of -21 dBi at 2.4 GHz, and its maximum specific absorption rate is compliant with IEEE safety standards.

An Implantable Antenna for Wireless Body Area Network Application

  • Kim, Ui-Sheon;Choi, Jae-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • 제10권4호
    • /
    • pp.206-211
    • /
    • 2010
  • In this paper, an implantable planar inverted-F antenna (PIFA) for an artificial cardiac pacemaker is proposed. The antenna has a simple structure with a low profile and is placed on the top side of the pacemaker. The dimensions of the pacemaker system, including the antenna element, are $42{\times}43.6{\times}11$ mm. When the antenna is embedded in pig tissue, its $S_{11}$ value is -10.94 dB at 403 MHz and the -10 dB impedance bandwidth of the antenna is 6 MHz (399~406 MHz). The proposed PIFA in tissue has a peak gain of -20.19 dBi and a radiation efficiency of 1.12 % at 403 MHz. When the proposed antenna is placed in a flat phantom, its specific absorption ratio (SAR) value is 0.038 W/kg (1 g tissue). Performances of the proposed PIFA is sufficient to operate at the MICS band (402 ~ 405 MHz).

심부 조직 인체 삽입용 세 가지 밴드 안테나 (A Triple Band Deep-Tissue Antenna for Biomedical Implants)

  • 유형석
    • 전기학회논문지
    • /
    • 제66권2호
    • /
    • pp.383-386
    • /
    • 2017
  • In this study, we introduce a triple-band flexible implantable antenna that is tuned by using a ground slot in three specific bands, namely Medical Implanted Communication Service (MICS: 402-405 MHz) for telemetry, the midfield band (lower gigahertz: 1.45-1.6 GHz) for Wireless Power Transfer (WPT), and the Industrial, Scientific and Medical band (ISM: 2.4-2.45 GHz) for power conservation. This antenna is wrapped inside a printed 3D capsule prototype to show its applicability in different implantable or ingestible devices. The telemetry performance of the proposed antenna was simulated and measured by using a porcine heart. From the simulation and measurement, we found that use of a ground slot in the implantable antenna can improve the antenna performance and can also reduce the Specific Absorption Rate (SAR).

Design of Implantable Rectangular Spiral Antenna for Wireless Biotelemetry in MICS Band

  • Lee, Jae-Ho;Seo, Dong-Wook;Lee, Hyung Soo
    • ETRI Journal
    • /
    • 제37권2호
    • /
    • pp.204-211
    • /
    • 2015
  • For this study, we designed an implantable rectangular spiral antenna for medical biotelemetry in the Medical Implant Communications Service band (402 MHz to 405 MHz). The designed antenna has a U-shaped loop for impedance matching. The antenna impedance is easily adjusted by controlling the shape and length of the U-shaped loop. Significant design parameters were studied to understand their effects on the antenna performance. To verify the potential of the antenna for the desired applications, we fabricated a prototype and measured its performance in terms of the resonant characteristics and gain radiation patterns of the antenna. In the testing phase, the prototype antenna was embedded in human skin tissue-emulating gel, which was developed to simulate a real operation environment. The measured resonant characteristics show good agreement with the simulations, and the -10 dB frequency band is within the range of 398 MHz to 420 MHz. The antenna exhibits a maximum gain of -22.26 dBi and an antenna efficiency of 0.215%.

Slotted Implantable Patch Antenna for ISM Band Application and Its Usage in WiMAX with an I-Shaped Defected Ground Structure

  • Ayubi, Adil Al;Sukhija, Shikha;Sarin, Rakesh Kumar
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권6호
    • /
    • pp.359-363
    • /
    • 2017
  • A slotted implantable patch antenna with microstrip feeding is proposed for industrial, scientific, and medical band applications. The result is verified by implanting the antenna in animal tissue. Further, by varying the ground width and introducing a defect into the ground structure, the antenna becomes applicable for worldwide interoperability for microwave access operations. A simulation is performed using Empire XCcel software. An Agilent vector network analyzer is used for analyzing the return loss performance. Simulated and measured results are compared. Antennas with and without defected ground structure both have key advantages including low profile, desirable return loss, good impedance matching and required bandwidth.

무선 Biotelemetry용 인체 이식형 안테나 (A Scalp-Implantable Antenna for Wireless Biotelemetry)

  • 유형석
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.112-115
    • /
    • 2016
  • This paper demonstrates a scalp-implantable miniaturized antenna at the medical implant communication service (MICS) (402-405MHz) band. The antenna size is only $27.63mm^3$($8.5mm{\times}6.5mm{\times}0.5mm$), which is the smallest antenna for the MICS band. Miniaturization is achieved by using a symmetrical serpentine shaped radiating patch and placing open-end slots in the ground plane. In addition, co-axial feeding is used for excitation with a shorting pin connected between the radiator and ground. The antenna was simulated in a homogeneous skin model and in the human scalp. An experimental prototype of the proposed antenna was fabricated and measured in a skin-mimicking gel. Good agreement was obtained between the measurement and simulation results, showing a broad bandwidth of 49 MHz (from 395 to 444 MHz) for |S11| less than -10 dB and a maximum gain of -42.87 dBi. This gain is higher than the previous MICS antenna with respect to antenna size.

Design of Implantable CPW Fed Monopole Antenna for ISM Band Applications

  • Kumar, S. Ashok;Shanmuganantham, T.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권2호
    • /
    • pp.55-59
    • /
    • 2014
  • An implantable CPW fed monopole antenna embedded into human tissue is proposed for ISM band biomedical applications. The proposed antenna is made compatible for implantation by embedding it in an alumina ceramic substrate (${\Box}_r=9.8$ and thickness=0.65 mm). The proposed antenna covers the ISM band of 2.45 GHz. The radiation parameters, such as return loss, E-Plane, H-Plane, are measured and analyzed, using the method of moments. The proposed antenna has substantial merits over other implanted antennas, like low profile, miniaturization, lower return loss, and better impedance matching and high gain.

Design and Performances of Implantable CPW Fed Apollian Shaped Antenna at 2.45 GHz ISM Band for Biomedical Applications

  • Kumar, S. Ashok;Sankar, J. Navin;Dileepan, D.;Shanmuganantham, T.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권5호
    • /
    • pp.250-253
    • /
    • 2015
  • A novel implantable CPW fed Apollian shaped antenna embedded into human tissue is proposed for ISM band biomedical applications. The proposed antenna is made compatible for implantation by embedding it in an alumina ceramic substrate(εr=9.8 and thickness= 0.65 mm). The proposed antenna covers the ISM band of 2.45 GHz. The radiation parameters such as return loss, xy-plane, xz-plane, and yz-plane etc., are measured and analyzed using the agilent vector network analyzer. The proposed antenna has substantial advantages, including low profile, miniaturization ability, lower return loss, better impedance matching, and high gain over conventional implanted antennas.

인체 삽입용 LC 공진형 혈압 센서 디자인 및 제작 (Design and Fabrication of Implantable LC Resonant Blood Pressure Sensor)

  • 김진태;김성일;정연호
    • 한국전기전자재료학회논문지
    • /
    • 제26권3호
    • /
    • pp.171-176
    • /
    • 2013
  • In this paper, we present a MEMS (micro-electro-mechanical system) implantable blood pressure sensor which has designed and fabricated with consideration of size, design flexibility, and wireless detection. Mechanical and electrical characterizations of the sensor were obtained by mathematical analysis and computer aided simulation. The sensor is composed of two coils and a air gap capacitor formed by separation of the coils. Therefore, the sensor produces its resonant frequency which is changed by external pressure variation. This frequency movement is detected by inductive coupling between the sensor and an external antenna coil. Theoretically analyzed resonant frequency of the sensor under 760 mmHg was calculated to 269.556 MHz. Fused silica was selected as sensor material with consideration of chemical and electrical reaction of human body to the material. $2mm{\times}5mm{\times}0.5mm$ pressure sensors fitted to radial artery were fabricated on the substrates by consecutive microfabrication processes: sputtering, etching, photolithography, direct bonding and laser welding. Resonant frequencies of the fabricated sensors were in the range of 269~284 MHz under 760 mmHg pressure.

비선형 연립방정식에 의한 체내 삽입형 초소형 텔레메트리 모듈의 3차원 위치추적 방법 (The Method for 3-D Localization of Implantable Miniaturized Telemetry Module by Analysis of Nonlinear Differential Equations)

  • 박종철;남혜원;박희준;송병섭;원철호;이승하;최현철;조진호
    • 센서학회지
    • /
    • 제12권6호
    • /
    • pp.249-257
    • /
    • 2003
  • 환자의 체내에 삽입하여 여러 가지 생체정보를 무선으로 전송하는 형태의 텔레메트리 기술은 환자들의 불편함을 해소하고 기존의 진단 한계를 극복하는데 큰 기여를 할 것으로 기대되고 있다. 체내에서 생체신호를 외부의 전송하는 시스템의 경우, 정확한 질병지점을 판단하기 위해서는 체내의 텔레메트리 모듈의 위치를 체외에서 정착하게 파악할 수 있는 기술이 필수적이다. 본 논문에서는 8개의 안테나를 고정된 위치에 두고, 비선형 연립방정식의 해석을 통하여 체내에 삽입된 송신모듈의 위치를 결정하는 방법을 제안하고 해석하였다.