• 제목/요약/키워드: Implant placement

검색결과 641건 처리시간 0.031초

흡수성 차폐막과 동종탈회동결건조골 이식에 의한 치조골 재생의 병용효과 (Alveolar Bone Formation in Dogs using Vicryl Absorbable Mesh(Polyglactin 910) and Decalcified Freeze-Dried Bone Grafting)

  • 오은정;정현주;김영준
    • Journal of Periodontal and Implant Science
    • /
    • 제29권3호
    • /
    • pp.469-484
    • /
    • 1999
  • The purpose of this study was to evaluate new bone formation following guided bone regeneration by resorbable and nonresorbable membrane. Six adult mongrel dogs were used. The first, second, third, fourth premolars in the mandible of each dog were extracted. Two months after tooth extraction, a buccal dehiscence defect was surgically created on each edentulous area. The experimental sites were divided into three groups according to the treatment modalities ; Group I-a: surgical treatment only ; Group I -b: allogenic decalcified freezed dried bone grafting ; Group II-a : e- PTFE membrane placement only ; Group II-b : allogenic decalcified freezed dried bone grafting and e-PTFE membrane placement ; Group III-a : Vicryl(R) mesh placement only ; Group III-b : allogenic decalcified freezed dried bone grafting and Vicryl(R) mesh placement . The animals were sacrificed at 8 weeks after operation and the specimens were prepared for histologic and histometric examination. The results were as follows : Clinically, all defect sites were healed without exposure of barrier membrane after the eight weeks. In Group I-a, dense connective tissues were impinged in the bony defect area. Well vascularized and fibrous bone marrow indicated that bone formation was still taking place was found. In Group I-b, in areas closer to the periphery, lamellation of the newly formed bone would found. In Group II-a, beneath the e-PTFE membrane a dense layer of connective tissue covering the most external portions of the regenerated tissue was seen. The new bone surfaces were lined with osteoid and osteoblast. In Group II-b, a dense layer of connective tissue covering the most external portions of the regenerated tissue was observed beneath the e-PTFE membrane. A notable amount of alveolar ridge regeneration was seen with new rigdes with well-contoured form. In Group III-a, the new bone surface were lined with osteoid and osteoblast, indicating active bone formation. A clear demarcation could not be noted between the host bone and new bone. In Group III-b, a notable amount of alveolar ridge regeneration was seen with new ridges assuming wellcontoured form. In areas closer to the periphery, lamellation of the newly formed bone would found. As histometric examination, the amount of bone formation was gained from $12.8mm^2$ to $26.3mm^2$. It was significantly greater in group II-b and group III-b compared to other groups(p<0.05) . These results suggest that Vicryl(R) mesh after DFDB grafting used in guided bone regeneration could create and sustain sufficient space for new bone formation.

  • PDF

자연치 부분 결손 환자에서 테이퍼 형태의 국산 임플란트(OSSTEM GS III)의 즉시하중 성공률에 대한 지연하중군과의 비교 임상연구 (Clinical Comparison of Immediately Loaded and Delayed Loaded OSSTEM GS III Implant in Partially Edentulous Patients)

  • 권민정;김영균;여인성;이양진
    • 구강회복응용과학지
    • /
    • 제27권3호
    • /
    • pp.267-275
    • /
    • 2011
  • 구치부 부분 결손 환자에서 즉시하중군과 지연하중군의 임상적 성공률을 측정하기 위한 전향적 연구가 계획되었다. 즉시하중군에서는 17명의 환자에 42개의 GSIII 임플란트(Osstem, Korea)를 식립하고 48시간 안에 하중을 가하였다. 대조군인 지연하중군에서는 15명의 환자에 27개의 GSIII 임플란트를 식립하고 평균 $2.6{\pm}1.7$개월 후에 하중을 가하였다. 하중 전 1차안정성을 ISQ로 측정하였고 임상증상, 동요도, 연조직 반응을 식립 직후, 3개월 후, 6개월 후, 12개월 후에 평가하였다. 변연골 흡수량은 치근단 방사선 영상으로 측정하였고 Mann-Whitney test (${\alpha}$=0.05)와 repeated measured ANOVA (${\alpha}$=0.05)로 두 군의 차이를 검정하였다. 식립 직후 실험군과 대조군의 ISQ는 각각 $80.3{\pm}7.1$$69{\pm}17$이었다. 실험군은 95.23%의 성공률을, 대조군은 100% 성공률을 나타냈다. 3개월과 6개월 후 실험군의 변연골 흡수량은 대조군에 비해 유의성 있게 컸다(p<0.05). 하지만 12개월 후 두 군의 차이는 관찰되지 않았다 (p>0.05). 변연골 흡수량은 성별과 식립위치에 따른 차이가 없었다 (p>0.05). 실험의 한계 내에서, 1차안정성이 획득된다면 구치부 식립 GSIII 임플란트의 즉시하중은 예지성 있는 치료법이라고 여겨진다.

Flap folding suture를 활용한 판막의 고정에 따른 임플란트 주변 연조직 3차원 부피 변화 관찰 (3D analysis of soft tissue around implant after flap folding suture)

  • 정세영;강대영;신현승;박정철
    • 구강회복응용과학지
    • /
    • 제37권3호
    • /
    • pp.130-137
    • /
    • 2021
  • 목적: 다양한 봉합술을 통해 임플란트 주변에 최적화된 각화점막을 확보하려는 시도가 진행되었다. 본 연구의 목적은 임플란트 식립 후 2개의 서로 다른 봉합술 시행 후 연조직의 치유 양상을 평가하는 것이다. 연구 재료 및 방법: 15명의 환자에서 18개의 임플란트가 식립되었고 연구에 포함되었다. 부가적인 골이식 없이 단순 임플란트 식립만 진행하였다. 2개의 서로 다른 봉합술을 이용해 paramarginal flap design을 시행한 협측 판막을 임플란트 치유 지대주 하방으로 고정하였다. 디지털 구내 스캐너를 이용하여 초진, 수술 직후, 발사, 3개월 시점에 스캔을 진행하였다. 각 시점에 따른 스캔 데이터를 인접치의 교두, 소와, 치유지대주 등의 여러 점들을 기준으로 초진 데이터와 중첩하였다. 각 시점의 스캔 데이터를 초진 데이터와 subtraction한 다음 임플란트 주위 연조직의 증가량에 해당하는 폐곡면의 부피를 측정하였다. 폐곡면의 부피는 mm3 단위로 계측하였다. 3개 시점에서 2개의 서로 다른 봉합술에 의한 부피 변화를 비교하기 위해 nonparametric rank-based 분석을 시행하였다. 결과: 양쪽 군 모두 치유는 양호하였다. 양쪽 봉합군은 수술 후 즉시 연조직 부피의 증가를 보여주었다. 3개월에 걸쳐 부피는 시간에 따라 유의성 있게 감소하였다(P < 0.001). Flap folding suture 군의 연조직 부피는 3개월 시점에서 interrupted suture 군보다 더욱 높은 중앙값을 보였으나 통계적 유의성은 없었다(P > 0.05). 결론: 임플란트 시행 시 paramarginal flap 형태로 거상된 판막을 flap folding suture로 고정한 군은 3개월 치유 기간 후 interrupted suture 군보다 더욱 높은 연조직 증강 수치를 보였다. 하지만 좀더 장기적인 관찰 연구가 필요할 것으로 사료된다.

임플란트 식립 시 골질이 주입회전력에 미치는 영향에 관한 삼차원 유한요소 분석 (Effect of Bone Quality on Insertion Torque during Implant Placement; Finite Eelement Analysis)

  • 정재덕;조인호
    • 구강회복응용과학지
    • /
    • 제25권2호
    • /
    • pp.109-123
    • /
    • 2009
  • 임플란트 골유착의 성공과 임플란트 안정성에서 가장 중요한 것은 골의 양과 질이며 안정성을 평가하는 방법 중 하나인 주입회전력도 골질에 영향을 받는다. 임플란트를 식립할 때 모터에서 생긴 힘이 임플란트에 전달되면 임플란트는 회전력(moment)과 축력(axial force)을 갖게 되고 임플란트와 접촉한 골에서는 절삭과 압박 그리고 마찰이 일어나 응력이 생기는데 이 때 측정되는 주입회전력(insertion torque)은 골질에 따라 다양하게 나타난다. 본 연구에서는 임플란트를 하악 소구치 부위 골에 식립하는 것을 가정하여 골질을 치밀골의 두께와 망상골의 밀도 그리고 하방 치밀골 존재 시로 나누고, 골의 응력과 변위를 소탄성 범위의 유한요소법으로 분석하고 유효응력(von Mises stress)과 회전력 그리고 축력을 비교 연구하여 골질이 주입 회전력에 미치는 영향을 평가하였다. 임플란트($Br{\aa}nemark$ MKIII.RP, ${\phi}3.75{\times}10.0mm$, Nobel Biocare, $G{\ddot{o}}teborg$, Sweden) 와 원통형 골모형(${\phi}9.5{\times}12.0mm$)의 유한요소 모형을 설계하고 변수로 상부 치밀골의 두께(0.5 mm, 1.5 mm, 2.5 mm)와 치밀골 하부에 망상골의 밀도($0.85g/cm^3$, $1.11g/cm^3$, $1.25g/cm^3$) 그리고 골모형 하부에 1 mm 두께의 치밀골 유무에 따라 총 7개의 모형을 만들었으며, 임플란트가 식립될 때 발생하는 유효응력과 축력 그리고 회전력을 시간대 별로 비교하였다. 임플란트 플랜지 하연이 골의 상부를 파고드는 300 msec, 중간 정도 들어간 550 msec, 완전히 들어가 플랜지 상면이 골 표면과 일치한 800 msec로 나누어 관찰하였을 때 축력은 500 msec 전후에서, 회전력은 800 msec 전후에서 최대값를 보였으며 유효응력 분포는 서로 비슷하였다. 이 같은 실험 결과를 바탕으로 축력을 영역 별로 비교하여 다음과 같은 결과를 얻었다. 1. $Br{\aa}nemark$ MKIII 임플란트는 플랜지가 골을 파고들 때 축력이 치밀 골에서 가장 높았고, 회전력은 플랜지가 골상부에 걸리어 축력이 급격히 감소한 이후에 최대 회전력을 보였으며, 이 때 유효응력 분포는 플랜지와 접촉하는 골 상부에 집중되었다. 2. 임플란트 식립 시 치밀골의 두께가 두꺼울수록 축력과 회전력이 높게 나타났으며 치밀골의 두께가 축력과 회전력에 가장 큰 영향을 주었다. 3. 치밀골의 두께가 1.5 mm 이상인 경우 망상 골의 밀도가 축력에 미치는 영향은 작았고, 치밀골의 두께가 0.5 mm인 경우 망상골의 밀도가 축력과 회전력에 영향이 있을 것으로 사료되었다. 4. 양측 피질골 존재 시 축력의 합은 상부 피질골의 두께가 같은 다른 경우와 비슷하였으나 부위별 촉력은 골하부에서 양측 피질골 모형이 가장 높았고, 회전력은 하방 피질골과 접촉할 때는 피질골 두께가 같은 다른 모형보다 다소 높으나 최대 회전력은 비슷하였다. 위 결과를 토대로 하악 소구치 부위에 $Br{\aa}nemark$ MKIII 임플란트 식립 시 골질과 관련된 요소 중에 치밀골의 두께가 주입회전력에 가장 큰 영향을 주며 망상골의 밀도를 높이는 술식도 일차적 안정성 증가에 유용할 것으로 사료되는 바이다.

성견의 하악골에 식립된 Miniplate에 가한 조기 부하의 영향에 관한 실험적 연구 (The experimental study of early loading on the Miniplate in the beagle dog)

  • 정용구;이영준;정규림
    • 대한치과교정학회지
    • /
    • 제33권4호
    • /
    • pp.307-317
    • /
    • 2003
  • 본 연구는 miniplate(Titanium C-tube, Martin Co., Germany)를 교정적 고정원으로 사용하여 교정력 및 악정형력을 즉시 가했을 때 miniplate의 안정성 및 주위 조직 반응을 관찰하여 고정원으로서의 유용성을 밝히고자 시행되었다. 네 마리의 비글 성견을 대상으로 하악의 좌우 협측 제3소구치와 제4소구치 사이에 두개의 titanium miniscrew(직경 2.0mm, 길이 7.0mm)에 의해 고정되는 miniplate를 식립하여 15주 동안 200-250gm의 힘을 가한 교정력 적용군과 8주 동안 400-450gm의 힘을 가한 악정형력 적용군으로 분류하였고 대조군은 제4소구치와 제1대구치사이에 식립하고 힘을 가하지 않았다. 동요도는 식립 직후와 희생 직전에 측정하여 비교하였고 희생 후 제작된 조직 절편을 방사선적으로 검사하여 주위 골의 흡수 여부를 관찰하였다. 실험 동물은 관류 고정하고 조직 절편은 레진 포매하여 비탈회 경조직 표본을 제작하였다 miniplate 제거 후의 조직의 치유와 연조직의 관찰을 위해 일부 조직편은 탈회 표본으로 제작하였다. 표본은 H&E 염색 후 광학 현미경하에서 검경하였고 위의 실험내용을 통해 다음과 같은 결과를 얻었다. 1. 교정력과 악정형력을 적용한 두 그룹 모두 miniscrew와 골간의 계면에는 직접적인 골유착이 일어났다. 힘의 크기에 따른 차이는 관찰되지 않았고, 힘의 적용기간이 증가함에 따라 골침착이 증가되었으며, 하중이 가해지지 않은 대조군이 실험군에 비해 골조직이 덜 침착되었다. 2. Miruplate와 miniscrew를 피개하고 있는 연조직은 염증소견 없이 모두 치유가 잘 일어났다. 3. 모든 실험군에서 동요도는 발생되지 않았고, 하중이 가해지지 않은 대조군의 경우 경미한 동요도를 보였으며, 교합력이 직접 가해진 대조군에서 고정원이 탈락될 정도의 동요도를 보였다. 4. Miniscrew 제거 후의 연조직 및 경조직은 정상조직의 형태와 구조로 치유되었다. 이상의 결과로 miniplate(Titanium C-tube, Martin Co., Germany)는 식립 즉시 악정형력 정도의 힘까지 수용할 수 있고, 인접 조직에 자극이 적은 골내 고정원으로서 충분한 가치가 있다고 판단되어 진다.

Self-drilling 방식의 마이크로임플란트 식립에 의해 발생하는 피질골 스트레인의 유한요소해석 (Finite element analysis of cortical bone strain induced by self-drilling placement of orthodontic microimplant)

  • 박진서;유원재;경희문;권오원
    • 대한치과교정학회지
    • /
    • 제39권4호
    • /
    • pp.203-212
    • /
    • 2009
  • 골밀도가 높고 두꺼운 피질골에 마이크로임플란트를 self-drilling 방식으로 식립하는 경우 과도한 수준의 골부하 (bone loading)가 발생할 위험이 있으며 이는 인접골의 정상적인 골개형(bone remodeling)에 장애를 초래할 수 있다. 이에, 본 연구에서는 유한요소해석으로 두께 1.0 mm의 피질골에 Absoanchor SH1312-7 마이크로임플란트((주)덴토스, 대구, 대한민국)가 self-drilling 방식으로 식립되는 과정(10회전, 식립깊이 5 mm)을 모사(simulation)하였으며 식립 단계별로 피질골에 발생되는 스트레인을 조사하였다. 식립중 마이크로임플란트 첨부의 절삭연(cutting flute)에 의한 골삭제로 생기는 나사길(threaded groove)의 치수를 얻기 위하여 가토 경골에 마이크로임플란트를 식립/제거한 후 Micro CT (Explore Locus RS, GE Healthcare, Ontario, Canada)를 이용하여 기하형상을 측정하였으며 이를 치밀골의 유한요소모델에 반영하였다. 해석결과, 치밀골에 발생되는 스트레인은 임플란트 식립깊이에 따라 증가하였고, 초기단계에서 나사산에 인접한 골에 국한되던 과부하 부위(스트레인이 4,000${\mu}$-strain을 상회하는 영역)가 식립깊이 증가에 따라 인접골 전체, 즉 나사산 인접부는 물론 골(valley) 부위에 접하는 모든 영역으로 확장되었다. 본 연구를 통해, self-drilling 방식으로 마이크로임플란트를 식립할 때 치밀골에 발생하는 스트레인 크기는 생리적인 골개형을 저해할 수 있는 수준임을 확인할 수 있었다.

Denta $Scan^R$을 이용한 즉시 임플랜트 시술시 최적의 식립 위치 대한 통계적 연구 (STATISTICAL STUDY ON OPTIMAL PLACEMENT OF IMMEDIATE DENIAL IMPLANTATION USING DENTA $SCAN^R$)

  • 신광호;이재봉;황병남
    • 대한치과보철학회지
    • /
    • 제38권4호
    • /
    • pp.552-560
    • /
    • 2000
  • Purpose : The purpose of this study was to determine proper position and angulation of an implant for immediate implantation. Materials and Method : From the years 1997 to 2000. 52 Denta $scan^R$ views, 22 upper and 32 lower jaw with an average age of 43 and 40 respectively, were investigated, which comprise intact upper and lower 6 anterior teeth and premolars. On the Denta $scan^R$, the optimal placement for the immediated implantation was simulated. The measuring methods included 1) Angulation difference between tooth long axis and alveolar bone process. 2) Angulation difference of long axis between tooth and installing fixture 3) Distance between center of tooth at cervical area and center of fixture. 4) Distance from root apex to the bone limit of vital structure. One sample t-test was used for statistical analysis. Result : The results were as follows. 1) At the maxillary central incisor and lateral incisor, angulation difference of long axis between tooth and installing fixture was respectively 0.5 and 3.2 degrees with the fixture center's palatally positioned 2mm apart from tooth center. 2) At the lower anterior 6 teeth, that was about $-2.8^{\circ}\;to\;-4.6^{\circ}$ with the fixture center's lingually positioned 1mm apart from tooth center. 3) At the maxillary canine and premolar, that was respectively $11.8^{\circ}\;and \;7.2^{\circ}$ with the fixture center palatally positioned $2\sim2.4mm$ apart from tooth center. 4) At the lower premolar area, that was about $0^{\circ}\;to\;2^{\circ}$ with the fixture center's lingually positioned $0.5{\sim}1mm$ apart from tooth center. 5) Distance from root apex to the bone limit of vital structure, at the maxillary anterior and premolars. was the range of 10 to 12mm, and at the mandibular anterior teeth and the 1st premolar, that was the range of 18 to 20mm. Conclusion : The proper implant position of maxillary anterior and premolar teeth is as paralleled as or more buccally angulated than long axis of tooth with the fixture center's palatally positioned. In mandiblular anterior region, long axis of implants is lingully angulated compared with long axis of tooth and in premolar, almost parelleled with long axis of tooth and alveolar process.

  • PDF

공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구 (A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS)

  • 박철;임주환;조인호;임헌송
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

Sandblasted large grit, acid etched 표면처리에 따른 교정용 미니 임플랜트의 제거회전력에 관한 연구 (Removal torque of sandblasted large grit, acid etched treated mini-implant)

  • 오남희;김성훈;국윤아;이근혜;강윤구;모성서
    • 대한치과교정학회지
    • /
    • 제36권5호
    • /
    • pp.324-330
    • /
    • 2006
  • Sandblasted large grit, acid etched(SLA)표면처리 된 교정용 미니 임플랜트와 평활면을 가진 교정용 미니 임플랜트 사이에 제거회전력과 조직학적 소견을 통해 표면처리된 교정용 임플랜트의 임상적 가능성에 대하여 알아보고자 하였다. 실험재료로는 길이가 9.5 mm, 외경이 1.8 mm인 custom made, screw shaped, titanium implants가 사용되었다. 미니 임플랜트는 두개의 군으로 분류되었는데 SLA군은 20개의 SLA 표면처리된 미니 임플랜트이었고, 평활면군은 크기와 형태가 같지만 SLA처리공정이 생략되어 제작된 20개의 미니 임플랜트로 구성되었다. 이들은 10마리 가토의 경골에 식립되었다. 각각의 가토의 우측 경골에는 SLA군의 미니 임플랜트 2개가 식립되었고, 좌측 경골에는 평활면군의 미니 임플랜트 2개가 식립되었다. 각 군에는 식립 직후 Ni-Ti coil spring에 의해 약 150 g의 지속적인 견인력이 주어졌다. 식립 6주 후에 10마리의 가토를 희생하였고, 안정된 상태에서 Ni-Ti coil spring을 제거하였으며 digital torque gauge를 이용하여 제거 회전력을 측정하였다. 식립 6주 후에 SLA군의 경우 (8.29 Ncm) 평활면군 (3.34 Ncm)에 비해 더 높은 평균 제거회전력을 나타내었고 조직학적 소견에서도 screw 하방에서의 신생골 형성이 관찰되었다. SLA 표면처리된 미니 임플랜트는 평활면 미니 임플랜트에 비해 좀 더 강한 교정력에 저항할 수 있을 것으로 예상되었다.

치조골 높이가 다른 2개 임플란트 금관의 고정연결 조건에 따른 응력분석 (Stress Analysis on the Splinted Conditions of the Two Implant Crowns with the Different Vertical Bone Level)

  • 전창식;정신영;강동완
    • 구강회복응용과학지
    • /
    • 제21권2호
    • /
    • pp.169-182
    • /
    • 2005
  • The purpose of this study was to compare the stress distribution around the surrounding bone according to the splinted and non-splinted conditions on the finite element models of the two implant crowns with the different vertical bone level. The finite element model was designed with the parallel placement of the two fixtures ($4.0mm{\times}11.5mm$) with reverse buttress thread on the mandibular 1st and 2nd molars. As the bone quality, the inner cancellous bone and the outer 2 mm cortical bone were designed, and the cortical and cancellous bone were assumed to be perfectly bonded to the implant fixture. The splinted model(Model 1) had 2 mm contact surface and the non-splinted model(Model 2) had $8{\mu}m$ gap between two implant crowns. Two group (Splinted and non-splinted) was loaded with 200 N magnitude in the vertical and oblique directions on the loading point position on the central position of the crown, the 2 mm and 4 mm buccal offset point from the central position. Von Mises stress value was recorded and compared in the fixture-bone interface in the bucco-lingual and mesio-distal sections. The results were as follows; 1. In the vertical loading condition of central position, the stress was distributed on the cortical bone and the cancellous bone around the thread of the fixture in the splinted and non-splinted models. In the oblique loading condition, the stress was concentrated toward the cortical bone of the fixture neck, and the neck portion of 2nd molar in the non-splinted model was concentrated higher than that of 1st molar compared to the splinted model. 2. In the 2 mm buccal offset position of the vertical loading compared to the central vertical loading, stress pattern was shifted from apical third portion of the fixture to upper third portion of that. In the oblique loading condition, the stress was distributed over the fixture-bone interface. 3. In the 4 mm buccal offset position of the vertical loading, stress pattern was concentrated on the cortical bone around the buccal side of the fixture thread and shifted from apical third portion of the fixture to upper third portion of that in the splinted and non-splinted models. In the oblique loading, stresses pattern was distributed to the outer position of the neck portion of the fixture thread on the mesio-distal section in the splinted and non-splinted models. Above the results, it was concluded that the direction of loading condition was a key factor to effect the pattern and magnitude of stress over the surrounding bone of the fixture under the vertical and oblique loading conditions, although the type with or without proximal contact did not effect to the stress distribution.