• Title/Summary/Keyword: Implant exposure

Search Result 182, Processing Time 0.03 seconds

Direct-to-implant breast reconstruction following nipple-sparing mastectomy: predictive factors of adverse surgical outcomes in Asian patients

  • Su, Chun-Lin;Yang, Jia-Ruei;Kuo, Wen-Ling;Chen, Shin-Cheh;Cheong, David Chon-Fok;Huang, Jung-Ju
    • Archives of Plastic Surgery
    • /
    • v.48 no.5
    • /
    • pp.483-493
    • /
    • 2021
  • Background Direct-to-implant (DTI) breast reconstruction after nipple-sparing mastectomy (NSM) with the use of acellular dermal matrix (ADM) provides reliable outcomes; however, the use of ADM is associated with a higher risk of complications. We analyzed our experiences of post-NSM DTI without ADM and identified the predictive factors of adverse surgical outcomes. Methods Patients who underwent NSM and immediate DTI or two-stage tissue expander (TE) breast reconstruction from 2009 to 2020 were enrolled. Predictors of adverse endpoints were analyzed. Results There were 100 DTI and 29 TE reconstructions. The TE group had a higher rate of postmastectomy radiotherapy (31% vs. 11%; P=0.009), larger specimens (317.37±176.42 g vs. 272.08±126.33 g; P=0.047), larger implants (360.84±85.19 g vs. 298.83±81.13 g; P=0.004) and a higher implant/TE exposure ratio (10.3% vs. 1%; P=0.035). In DTI reconstruction, age over 50 years (odds ratio [OR], 5.43; 95% confidence interval [CI], 1.50-19.74; P=0.010) and a larger mastectomy weight (OR, 1.65; 95% CI, 1.08-2.51; P=0.021) were associated with a higher risk of acute complications. Intraoperative radiotherapy for the nipple-areolar complex increased the risk of acute complications (OR, 4.05; 95% CI, 1.07-15.27; P=0.039) and the likelihood of revision surgery (OR, 5.57; 95% CI, 1.25-24.93; P=0.025). Conclusions Immediate DTI breast reconstruction following NSM is feasible in Asian patients with smaller breasts.

The effect of high concentration of glucose on the production of proinflammatory cytokines and nitric oxide induced by lipopolysaccharides from periodontopathic bacteria (고농도의 글루코스가 치주질환 병인균주의 세균내독소에 의한 염증성 cytokine 및 nitric oxide의 생성에 미치는 영향)

  • Kim, Sung-Jo
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.511-520
    • /
    • 2008
  • Purpose: Diabetes mellitus is a clinically and genetically heterogeneous group of metabolic disorders manifested by abnormally high levels of glucose in the blood. Mounting evidence demonstrates that diabetes is a risk factor for gingivitis and periodontitis. The circulating mononuclear phagocytes in diabetic patients with hyperglycemia are chronically exposed to high level of serum glucose. Thus, this study attempted to determine the effect of pre-exposure of monocytes and macrophages to high concentration of glucose on lipopolysaccharide (LPS)-induced production of pro-inflammatory mediators. Material and Methods: For this purpose, cells were cultured in medium containing normal (5 mM) or high glucose (25 mM) for 4-5 weeks before treatment for 24 h with LPS. LPS was highly purified from Porphyromonas gingivalis or Prevotella intermedia by phenol extraction. Result: Results showed that prolonged pre-exposure of cells to high glucose markedly increased LPS-stimulated NO secretion when compared to normal glucose. In addition to NO, high glucose also augmented LPS-stimulated IL-6, IL-8, and TNF-$\alpha$ secretion after cells were exposed to high glucose for 4 weeks. Conclusion: The present study demonstrates that pre-exposure of mononuclear phagocytes with high glucose augments LPS-stimulated production of pro-inflammatory mediators. These findings may explain why periodontal tissue destruction in diabetic patients is more severe than that in non-diabetic individuals.

Effect of Blood Contamination on Vickers Microhardness and Surface Morphology of Mineral Trioxide Aggregate

  • Jaehyun Seung;Seong-Jin Shin;Byounghwa Kim;Ji-Myung Bae;Jiyoung Ra
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.51 no.2
    • /
    • pp.165-175
    • /
    • 2024
  • This study aimed to investigate the effects of blood contamination on the Vickers hardness and the surface morphology of premixed MTA and compare them with the effects on conventional MTA. The Vickers microhardness of Endocem MTA Premixed Regular (EP) and ProRoot MTA (PM) was assessed after immersion in fetal bovine serum (FBS) and saline. Stem cells from human exfoliated deciduous teeth (SHED) were seeded on MTA after immersion in FBS, saline, and deionized water (DW). Cell adhesion patterns and surface morphology were visualized via scanning electron microscopy (SEM). The surface microhardness of EP and PM in FBS was lower than in saline. However, short-term exposure of PM to FBS did not reduce the microhardness compared to saline. Angular crystals formed in water, while rounded crystals with more air voids appeared in FBS. Favorable SHED attachment occurred in all groups. Overall, the surface hardness of EP and PM decreased after FBS exposure, although PM was less influenced. We suggest minimizing the amount of bleeding when using MTA clinically; nevertheless, PM remains an option with more expected blood contamination than EP. In summary, exposure to FBS decreased mechanical performance but allowed cell adhesion for both MTAs, with PM being more resistant to these changes.

Study on the Correlation between the Change in SAR and Temperature of the Human Head by use Dental Implant on 3.0T Brain MRI : Using the XFDTD program (3.0T Brain MRI 검사 시 치아임플란트 시술 유무와 인체의 SAR, 체온 변화와의 상관관계에 관한 연구 : XFDTD 프로그램을 이용)

  • Choe, Dea-yeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.139-146
    • /
    • 2017
  • At the Brain MRI examination, RF Pulse are irradiated on the human head in order to acquire MR images. At this time, a considerable part of the irradiated RF Pulse energy is absorbed in our body and the temperature of the human head will rise depending on the degree of exposure, so it will affect the human head. Even if the same RF Pulse energy is given, if the metal is inserted in the human head, the conductivity of the human head is greatly increased by the metal, so the SAR value increases and the temperature also rises. Therefore, we started this research with the question as to whether there is difference between the change in SAR value and temperature displayed on the head of the human according to use or not of the dental implant. Experiments were using the XFDTD program on a 128 MHz RF Pulse frequency by a 3.0 tesla MRI. We can see that both are increasing that the average value of SAR and temperature that absorbed by the human head model used the dental implant. In addition, the average maximum SAR value and the maximum temperature rise in the brain part are shown below the international safety standard value but the influence can not be ignored because of the result may change according to the increase in the number of dental implant. And as future tasks. we need to the simulation of temperature rise and SAR due to an increase in the number of implants and volumes of teeth, dental implant material.

Bacterial Adhesion And Penetration To e-PTFE Membrane Used For The Guided Tissue Regeneration (치주조직재생유도술용 비흡수성 차폐막 (e-PTFE membrane)에의 세균부착 및 침투)

  • Chung, Hyun-Ju;Lee, Sung-Mi;Lee, Ho-Jae;Kim, Ok-Soo
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.103-116
    • /
    • 1996
  • This study was performed to observe the bacterial adhesion and penetration to e-PTFE membrane following guided tissue regeneration(GTR) procedure and to evaluate the association of the membrane exposure and bacterial contamination with the clinical outcome. For the study, ten infrabony defects in 9 patient were treated by mucoperiosteal flap operation including placement of the e-PTFE membrane. The treated teeth were monitored weekly for the membrane exposure, gingival recession and gingival inflammation. The membranes were retrieved after 4 to 6 weeks, examined by SEM for bacterial contamination and adherent connective tisue elements, and observed under LM for the bacterial penetration into membrane. Three months postsurgery, the defect sites were clinically reexamined for the changes in attachment level and probing depth. Comparison of the ultrastuctural findings and clinical outcome revealed that extent of membrane exposure and bacterial contamination of the membrane was inversely associated with clinical attachment gain. From this finding, the extent of membrane exposure and the bacterial contamination on the apical portion of the e-PTFE membrane at the time of removal seemed to be a critical determinant on the clinical outcome of GTR and the membrane exposure needs to be controlled for optimal results.

  • PDF

Long-term exposure to gefitinib differentially regulates the endosomal sorting complex required for transport machinery, which accelerates the metastatic potential of oral squamous cell carcinoma cells

  • Mi Seong Kim;Min Seuk Kim
    • International Journal of Oral Biology
    • /
    • v.48 no.1
    • /
    • pp.1-7
    • /
    • 2023
  • Oral squamous cell carcinoma (OSCC), which accounts for approximately 90% of oral cancers, has a high rate of local recurrence and a poor prognosis despite improvements in treatment. Exosomes released from OSCC cells promote cell proliferation and metastasis. Although it is clear that the biogenesis of exosomes is mediated by the endosomal sorting complex required for transport (ESCRT) machinery, the gene expression pattern of ESCRT, depending on the cell type, remains elusive. The exosomal release from the human OSCC cell lines, HSC-3 and HSC-4, and their corresponding gefitinib-resistant sub-cell lines, HSC-3/GR and HSC-4/GR, was assessed by western blot and flow cytometry. The levels of ESCRT machinery proteins, including Hrs, Tsg101, and Alix, and whole-cell ubiquitination were evaluated by western blot. We observed that the basal level of exosomal release was higher in HSC-3/GR and HSC-4/GR cells than in HSC-3 and HSC-4 cells, respectively. Long-term gefitinib exposure of each cell line and its corresponding gefitinib-resistant sub-cell line differentially induced the expression of the ESCRT machinery. Furthermore, whole-cell ubiquitination and autophagic flux were shown to be increased in gefitinib-treated HSC-3 and HSC-4 cells. Our data indicate that the expression patterns of the ESCRT machinery genes are differentially regulated by the characteristics of cells, such as intracellular energy metabolism. Therefore, the expression patterns of the ESCRT machinery should be considered as a key factor to improve the treatment strategy for OSCC.

A 15-year clinical retrospective study of Br${\aa}$nemark implants (Br${\aa}$nemark 임플란트의 15년 임상적 후향 연구)

  • Park, Hyo-Jin;Cho, Young-Ye;Kim, Jong-Eun;Choi, Yong-Geun;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.61-66
    • /
    • 2012
  • Purpose: This study was to compare the cumulative survival rate (CSR) of Br${\aa}$nemark machined surface implants and TiUnite$^{TM}$ imlants and to analyze association between risk factors and the CSR of the implants. Materials and methods: A retrospective study design was used to collect long-term follow-up clinical data from dental records of 156 patients treated with 541 Br${\aa}$nemark machined and TiUnite$^{TM}$ implants at Korea University Guro hospital in South Korea from 1993 through 2008. Machined implant and TiUnite$^{TM}$ implant were compared by CSR. Exposure variables such as gender, systemic disease, location, implant length, diameter, prosthesis type, opposing occlusion type, date of implant placement, type of edentulous space, abutment type, existence of splinting with natural teeth, and existence of cantilever were collected. Life table analysis was undertaken to examine the CSR. Cox regression method was conducted to assess the association between potential risk factors and overall CSR (${\alpha}$=.05). Results: Patient ages ranged from 16 to 75 years old (mean age, 51 years old). Implants were more frequently placed in men than women (94 men versus 63 women). Since 1993, 264 Br${\aa}$nemark machined implants were inserted in 79 patients and since 2001, 277 TiUnite$^{TM}$ implants were inserted in 77 patients. A total survival rate of 86.07% was observed in Br${\aa}$nemark and Nobel Biocare TiUnite$^{TM}$ during 15 years. A survival rate of machined implant during 15 years was 82.89% and that of TiUnite$^{TM}$ implant during 5 years was 98.74%. The implant CSR revealed lower rates association with several risk factors such as, systemic disease, other accompanied surgery, implant location, and Kennedy classification. Conclusion: Clinical performance of Br${\aa}$nemark machined and TiUnite$^{TM}$ implant demonstrated a high level of predictability. In this study, TiUnite$^{TM}$ implant was more successful than machined implant. The implant CSR was associated with several risk factors.

The influence of Collar design on peri-implant marginal bone tissue (Collar design이 임플랜트 주위 변연골 흡수에 미치는 영향)

  • Kim, Jee-Hwan;Jung, Moon-Kyou;Moon, Hong-Suk;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.53-64
    • /
    • 2008
  • Statement of problem: Peri-implant marginal bone loss is an important factor that affects the success of implants in esthetics and function. Various efforts have been made to reduce this bone loss by improving implant design and surface texture. Previous studies have shown that early marginal bone loss is affected by implant neck designs. Purpose: The purpose of this study was to examine the influence of laser microtexturing of implant collar on peri-implant marginal bone loss. Materials and methods: Radiographical marginal bone loss was examined in patients treated with implant-supported fixed partial dentures. Marginal bone level was examined with 101 implant fixtures installed in 53 patients at three periods(at the time of implantation, prosthetic treatment and 6-month after loading). Four types of implants were examined. The differences of bone loss between implants(ITI standard) with enough biologic width and implants(ITI esthetic plus, Silhouette IC, Silhouette IC Laser-$Lok^{TM}$) with insufficient biologic width have been compared. Resorption angles were examined at the time of prosthetic delivery and 6-month after loading. Results and Conclusion: Within the limitation of this study, the following results were drawn. 1. The marginal bone loss of ITI standard and Silhouette IC Laser-$Lok^{TM}$ was less than that of ITI esthetic plus and Silhouette IC(P<0.05). The marginal bone loss between ITI standard and Silhouette IC Laser-$Lok^{TM}$ had no significant statistical difference(P>0.05). There was no significant statistical difference between marginal bone loss of ITI esthetic plus and Silhouette IC(P>0.05). 2. There was no significant difference in marginal bone loss between maxilla and mandible(P>0.05). 3. There was no significant difference in resorption angle among four types of implants(P>0.05). The marginal bone of implants with supracrestal collar design of less than that of biologic width had resorbed more than those with sufficient collar length. The roughness and laser microtexturing of implant neck seem to affect these results. If an implant with collar length of biologic width, exposure of fixture is a possible complication especially in the anterior regions of dentition that demand high esthetics. Short smooth neck implant are often recommended in these areas which may lack the distance between microgap and the marginal bone level. In these cases, the preservation of marginal bone must be put into consideration. From the result of this study, it may be concluded that laser microtexturing of implant neck is helpful in the preservation of marginal bone.

A RETROSPECTIVE EVALUATION OF IMPLANT INSTALLATION WITH MAXILLARY SINUS AUGMENTATION BY LATERAL WINDOW TECHNIQUE (측방접근법을 이용한 상악동거상술 후 임프란트 식립에 대한 후향적 평가)

  • Ki, Se-Il;Yu, Min-Gi;Kim, Young-Joon;Kook, Min-Suk;Park, Hong-Ju;Shet, Uttom Kumar;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.5
    • /
    • pp.457-464
    • /
    • 2008
  • Purpose: The aim of this study was to evaluate the clinical results of implants which were installed with maxillary sinus elevation by using lateral window technique. Materials and methods: We performed the maxillary sinus elevation by lateral window technique to 87 patients who visited Dept. of Oral & Maxillofacial Surgery, Chonnam National University Hospital from January, 2003 to January, 2007. When the residual bone height was from 3 mm to 7 mm, the sinus elevation and simultaneous implant installation was mostly performed. When the residual bone height was less than 3 mm, the sinus elevation was performed and the delayed implant installation was done after 5 or 6 months. No artificial membranes were used for coverage of the lateral bony window site and freeze dried fibrin sealant was applied to the grafted bone. The mean follow-up period was 28.5 months (ranged from 10 months to 48 months) Results: 1. Unilateral sinus elevations were performed in 51 patients and bilateral sinus elevations were performed in 36 patients. And the total number of sinus elevation procedure was 123 cases. 2. The sinus elevation and simultaneous implant installation was performed in 89 sinuses and 249 implants were installed. The sinus elevation and delayed implant installation was performed in 44 sinuses and 141 implants were installed. The total number of implants were 390 in 133 sinuses. The average healing period after sinus elevations was 6.1 months in delayed implant installation. 3. Only autogenous bone, autogenous bone mixing with allografts or autogenous bone mixing with xenografts were used as graft materials. 4. The average period from first surgery to second surgery was about 7.2 months. 5. Some patients complications, such as perforation of sinus membrane, swelling, infection and exposure of cover screw. Two implants were removed in the infected sinus. 6. The survival rate of implants with maxillary sinus elevation by lateral window technique was 99.5% and the success rate of implants was 95.1%. Conclusions: These results indicated that the implants which were installed with maxillary sinus elevation by lateral window technique showed high survival and success rates.

Clinical, histologic, and histometric evaluation of implants with microthreaded crest module and SLA surface (SLA로 표면처리한 microthreaded crest module 임프란트의 임상적, 조직학적, 조직계측학적 분석)

  • Moon, Sang-Kwon;Pang, Eun-Kyoung;Kim, Chang-Sung;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.127-138
    • /
    • 2004
  • Background: Crestal bone loss known as saucerization is a frequently observed phenomenon. Recent studies have shown that implants with micothreaded crest module reduced the force concentration in the crestal region thus resulting in no or reduced crestal bone loss. This study presents a clinical, histologic, and histometric evaluation of implants with microthreaded crest module and SLA surface. Methods: The implants were placed in the mandible of 5 beagle dogs weighing 10-15kg. Four premolars were bilaterally extracted 8 weeks prior to implant placement. Mucoperiosteal flap was elevated and drilling with increasing diameter was performed under saline irrigation. After countersinking 2 implants were placed in each side resulting in 4 implants per dog. Healing period of 8 weeks was allowed before sacrificing the animals. Histologic preparation was performed for histologic and histometric analysis. Bone to implant contact as well as percentage of bone area inside threads were measured. T-test was used for statistical analysis with pvalue p<0.05. Results: 1. Healing was uneventful without any cover screw exposure. New bone formation around the implants was observed without any inflammatory infiltration. 2. Bone to implant contact in the microthread and thread were 43.90 ${\pm}$ 20.30 %, and 53.19 ${\pm}$ 20.97 % respectively. The overall bone to implant contact was 48.54 ${\pm}$ 20.95 %. 3. Percentage of bone area inside threads were 54.43 ${\pm}$ 10.39 %, and 38.44 ${\pm}$ 16.44 % for the microthread and thread respectively. There was statistically significant difference(p<0.05). The overall percentage of bone area inside threads was 46.67 ${\pm}$ 15.68 %.