• Title/Summary/Keyword: Implant biologic width

Search Result 10, Processing Time 0.018 seconds

Consideration of Vertical Position for predictable posterior implant - Deep implantation for Implant Biologic width (예지성 있는 구치부 임플란트를 위한 임플란트의 수직적 깊이에 대한 고려 Implant Biologic width를 위한 Deep Implantation)

  • Yun, Woo-Hyuk
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.27-41
    • /
    • 2019
  • For predictable posterior implants, appropriate soft tissue thickness, called the biologic width, is required around the implant for crestal bone stability. In order to do so, it seems that there are many cases where the implant should be positioned deeper than the depth that we previously thought was appropriate or inevitable limit. I would like to share my clinical experience about the vertical position of the posterior implant with the case reports and the related surgical technique.

The influence of Collar design on peri-implant marginal bone tissue (Collar design이 임플랜트 주위 변연골 흡수에 미치는 영향)

  • Kim, Jee-Hwan;Jung, Moon-Kyou;Moon, Hong-Suk;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.53-64
    • /
    • 2008
  • Statement of problem: Peri-implant marginal bone loss is an important factor that affects the success of implants in esthetics and function. Various efforts have been made to reduce this bone loss by improving implant design and surface texture. Previous studies have shown that early marginal bone loss is affected by implant neck designs. Purpose: The purpose of this study was to examine the influence of laser microtexturing of implant collar on peri-implant marginal bone loss. Materials and methods: Radiographical marginal bone loss was examined in patients treated with implant-supported fixed partial dentures. Marginal bone level was examined with 101 implant fixtures installed in 53 patients at three periods(at the time of implantation, prosthetic treatment and 6-month after loading). Four types of implants were examined. The differences of bone loss between implants(ITI standard) with enough biologic width and implants(ITI esthetic plus, Silhouette IC, Silhouette IC Laser-$Lok^{TM}$) with insufficient biologic width have been compared. Resorption angles were examined at the time of prosthetic delivery and 6-month after loading. Results and Conclusion: Within the limitation of this study, the following results were drawn. 1. The marginal bone loss of ITI standard and Silhouette IC Laser-$Lok^{TM}$ was less than that of ITI esthetic plus and Silhouette IC(P<0.05). The marginal bone loss between ITI standard and Silhouette IC Laser-$Lok^{TM}$ had no significant statistical difference(P>0.05). There was no significant statistical difference between marginal bone loss of ITI esthetic plus and Silhouette IC(P>0.05). 2. There was no significant difference in marginal bone loss between maxilla and mandible(P>0.05). 3. There was no significant difference in resorption angle among four types of implants(P>0.05). The marginal bone of implants with supracrestal collar design of less than that of biologic width had resorbed more than those with sufficient collar length. The roughness and laser microtexturing of implant neck seem to affect these results. If an implant with collar length of biologic width, exposure of fixture is a possible complication especially in the anterior regions of dentition that demand high esthetics. Short smooth neck implant are often recommended in these areas which may lack the distance between microgap and the marginal bone level. In these cases, the preservation of marginal bone must be put into consideration. From the result of this study, it may be concluded that laser microtexturing of implant neck is helpful in the preservation of marginal bone.

A new classification of periodontal and peri-implant disease (치주질환 및 임플란트 주위 질환의 새 분류)

  • Shin, Hyun-Seung
    • The Journal of the Korean dental association
    • /
    • v.57 no.12
    • /
    • pp.758-767
    • /
    • 2019
  • The classification of periodontal disease in 1999 has been widely used for determining a diagnosis, establishing a treatment plan, and evaluating the prognosis of the patient with periodontal disease. However, scientific evidence from many studies indicates the need for a new classification system for periodontal and peri-implant disease. Summary at 2017 world workshop as follows: 1) Periodontal health and peri-implant health was defined; 2) Chronic periodontitis and aggressive periodontitis were unified as periodontitis; 3) Periodontitis was further classified by staging and grading to reflect disease severity and management complexity, rate of disease progression, respectively; 4) Periodontal disease as manifestation of systemic disease is based on the International Statistical Classification of Diseases and Related Health Problems-10 (ICD-10) code; 5) Periodontal biotype and biologic width was replaced to periodontal phenotype and supracrestal tissue attachment, respectively; 6) The excessive occlusal force was replaced by a traumatic occlusal force; 7) ≥3 mm of radiographic bone loss, ≥6 mm of pocket probing depth and bleeding on probing indicates peri-implantitis in the absence of radiograph at final prosthesis delivery.

  • PDF

Effect of cleansing methods on the bone resorption due to repeated dis/re-connection of implant abutment (지대주 풀림과 조임시 지대주 세척방법에 따른 임플란트 주변 골소실의 양에 대한 평가)

  • Yang, Seung-Min;Shin, Seung-Yun;Kye, Seung-Beom
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.3
    • /
    • pp.535-542
    • /
    • 2007
  • Background : Repeated dis/re-connection of implant abutment caused bone loss around implant fixtures due to the new formation of biologic width of the mucosal-implant barrier. The aim of this clinical study was to evaluate whether the repeated dis/re-connection of implant abutment cause bone loss clinically and the effect of cleansing methods on a bone loss during the early healing period. Methods : A total 50 implants were installed in 20 patients and repeated dis/re-connection of abutment was performed at the time of surgery and once per week for 12 weeks. 0.9% normal saline solution as group1 and 0.1% chlorhexidine solution as group 2 was used to clean abutments. All patients had radiographs taken at the placement of implant and 4, 8, and 12 weeks postoperatively. The data for bone loss around implant were analyzed. Results: The marginal bone loss at 12 weeks were $1.28{\pm}0.51mm$, $1,32{\pm}0,57mm$ in the mesial and distal sides in group1, $1.94{\pm}0.75mm$, $1.81{\pm}0.84mm$ in group 2, respectively. In view of marginal bone loss, there was not a significant statistical difference between groups. Conclusions : Repeated dis/re-connection of implant abutment may not cause marginal bone loss around implant fixture although limited samples and short-term observation period. In spite of more bone loss in group 2, there was no statistical significant difference between groups. In context of those results, the clinical significance of the repeated dis/re-connection of implant abutment and the cleansing method of abutments is debatable when it comes to marginal bone loss during early healing period.

Influence of bone loss pattern on stress distribution in bone and implant: 3D-FEA study (주변 골흡수 양상에 따른 임플란트와 골의 응력분산에 관한 유한요소 분석)

  • Lee, Jong-Hyuk;Kim, Sung-Hun;Lee, Jae-Bong;Han, Jung-Suk;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.111-121
    • /
    • 2010
  • Purpose: This 3D-FEA study was performed to investigate the influence of marginal bone loss pattern around the implant to the stress distribution. Material and methods: From the right second premolar to the right second molar of the mandible was modeled according to the CT data of a dentate patient. Teeth were removed and an implant ($\Phi\;4.0{\times}10.0mm$) was placed in the first molar area. Twelve bone models were created; Studied bone loss conditions were horizontal bone loss and vertical bone loss, assumed bone loss patterns during biologic width formation, and pathologic vertical bone loss with or without cortification. Axial, buccolingual, and oblique force was applied independently to the center of the implant crown. The Maximum von Mises stress value and stress contour was observed and von Mises stresses at the measuring points were recorded. Results: The stress distribution patterns were similar in the non-resorption and horizontal resorption models, but differed from those in the vertical resorption models. Models assuming biologic width formation showed altered stress distribution, and weak bone to implant at the implant neck area seams accelerates stress generation. In case of vertical bone resorption, contact of cortical bone to the implant may positively affect the stress distribution.

Effects of implant collar design on marginal bone and soft tissue (임플란트의 collar design이 변연골과 연조직에 미치는 영향)

  • Yoo, Hyun-Sang;Kang, Sun-Nyo;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.21-28
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the effects of implant collar design on marginal bone change and soft tissue response by an animal test. Materials and methods: Two types of Implant (Neobiotech Co. Seoul, Korea) that only differs in collar design were planted on two healthy Beagle dogs. The implants were divided into two groups, the first group with a beveled collar (Bevel Group) and the second group with "S" shaped collar (Bioseal group). Standardized intraoral radiographs were used to investigate the mesio-distal change of the marginal bone. Histological analysis was done to evaluate the bucco-lingual marginal bone resorption and the soft tissue response adjacent to the implant. Mann-Whitney test was done to compare the mesio-distal marginal bone change at equivalent time for taking the radiographs and the tissue measurements between the groups. Results: Radiographic and histological analysis showed that there was no difference in marginal bone change between the two groups (P>.05). Histological analysis showed Bioseal group had more rigid connective tissue attachment than the Bevel group. There was no difference in biological width (P>.05). Bevel group showed significantly longer junctional epithelium attachment and Bioseal group showed longer connective tissue attachment (P<.05). Conclusion: For three months there were no differences in marginal bone change between the Bevel group and the Bioseal group. As for the soft tissue adjacent to the implant, Bioseal group showed longer connective tissue attachment while showing shorter junctional epithelium attachment. There were no differences in biologic width.

Surgical extrusion in aesthetic area (심미적인 부위에서의 외과적 정출술)

  • Park, Hyun-Kyu;Park, Jin-Woo;Suh, Jo-Young;Lee, Jae-Mok
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.287-295
    • /
    • 2007
  • As a general treatment modality of subgingival tooth defect in aethetic area, implant or crown and bridge therapy after extraction of affected tooth can be used. But as more conservative treatment, crown lengthening can be considered and not to lose periodontal attachment and impair aethetic appearance, surgical extrusion can be considered as a treatment of choice. In this case report, 3 cases of surgical extrusion was represented and appropriate time for initiation of endodontic treatment according to the post-surgical tooth mobility was investigated. In 8 patient who has subgingival tooth defect in aethetic area, intracrevicular incision is performed and flap was reflected with care not to injure interproximal papillae. With forcep or periotome, tooth was luxated and sutured in properely extruded position according to biologic width with or without $180^{\circ}$ rotation. 8 cases show favorable short and long term results. In some cases, surgical extrusion with $180^{\circ}$ rotation can minimized extent of extrusion and semi-rigid fixation without apical bone graft seems to secure good prognosis. In 8 cases, endodontic treatment started about 3 weeks after surgery. This time corresponds with the moment when mobility of extruded tooth became 1 degree and this results concide with other previous reports. If it is done on adequate case selection and surgical technique, surgical extrusion seems to be a good treatment modalilty to replace the implant restoration in aethetic area.

Immediate Connection of Customized Zirconia Abutment Using Flapless Guided Surgery: A Clinical Report (무절개 수술을 이용한 맞춤형 지르코니아 지대주의 즉시 장착 증례)

  • Lee, Gyeong-Je;Choi, Byung-Ho;Kim, Hee-Jun;Jung, Seng-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.201-212
    • /
    • 2012
  • There are some similar aspects at histological and morphological characteristics between the peri-implant tissue and periodontal tissue and the direct attachment between the titanium and soft tissue around the implant called as "Functional ankylosis" can prevent the apical infiltration of inflammatory and bone resorption around implant. But, the repeated connection and disconnection of the abutment can destroy the mucosal barrier of soft tissue around the implant and can cause the marginal bone resorption. The amount of marginal bone resorption may reduced if the prosthetic abutment is placed at that time of surgery. Connection of the prosthetic abutment at surgery was limited because the low accuracy of conventional method, but by using of Cone Beam Computed Tomography(CBCT) and guide surgery, the 3-dimensional accuracy of implant placement became much higher than before and it became possible. This is a clinical case of immediate connection of prosthetic abutment and provisional restoration by using of precise CBCT diagnosis and pre-fabricated zirconia customized abutment at surgery and the alternative method is described in this article because of the clinically contentable results.

RIGID FIXATION AND SPACE MAINTENANCE BY TITANIUM MESH FOR RECONSTRUCTION OF THE PREMAXILLA (상악골 전방 결손부 재건 시 견고 고정과 공간 유지로 사용된 타이타니움 메쉬의 임상 예)

  • Lee, Eun-Young;Kim, Kyoung-Won;Choi, Hee-Won;Koh, Myoung-Won
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.1
    • /
    • pp.85-92
    • /
    • 2005
  • Reconstruction of defect in the anterior part of the maxilla to enable implant placement or prothesis is a complicated treatment due to the anatomical position and lack of soft tissues. Two cases are presented in which autogenous iliac PMCB(particulate marrow and cancellous bone) with titanium mesh were used for premaxilla reconstruction and alveolar bone repair of the anterior maxillas prior to denture and implants fixation respectively. Cancellous bone from the anterior iliac crest was compressed and placed against a titanium mesh fixed to the bone of palate in a patient with severe defect of the anterior maxilla. There were no problem in the healing, and the anterior maxillas of two patients had increased height and width during the initial healing and remodeling. The clinical reports describe the use of titanium mesh for reconstruction of premaxilla. Autogenous bone grafts were harvested from the iliac crest and were loaded on a titanium mesh that were left in the patient's maxilla for 6 months before they were removed respectively. The radiographic analysis demonstrated that a 10mm vertical ridge augmentation had been achieved. In guided bone regeneration, the quantity of bone regenerated under the barrier has been demonstrated to be directly related to the amount of the space under the membrane. This space can diminish as a result of membrane collapse. To avoid this problem which involved the use of a titanium mesh barrier to protect the regenerating tissues and to achieve a rigid fixation of the bone segments, were used in association with autologous bone in 2 cases. The aim of this study was to evaluate the capability of a configured titanium mesh to serve as a mechanical and biologic device for restoring a vertically defected premaxilla.

Histological healing after grafting of bilayer artificial dermis in the oral environment (치은부에 이식한 이중인공진피의 조직학적 치유)

  • Kim, Min-Jeong;Chung, Hyun-Ju;Kim, Ok-Su;Kim, Young-Joon
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.2
    • /
    • pp.289-299
    • /
    • 2003
  • The autogenous free gingival graft is the most predictable procedure currently used to increase the width of the attached gingiva in periodontics. But the major disadvantage of the procedure is to create the multiple surgical wounds at both a donor site and a recipient site. The other problem is the limited amount of available graft material in oral cavity. Therefore, recent researches have been focused to develop the biomaterial to substitute the autogenous gingival tissue. The purpose of this study was to evaluate the histologic healing after grafting of bilayer artificial dermis, compared to the free gingival graft. Four non-smoking subjects (mean age, 32.5 years) in systemically healthy state and good oral hygiene were selected according to their particular needs for correction of mucogingival problems as suggested by Nabers(1966). The recipient sites were prepared through the procedure for the free gingival graft and were grouped according to the graft materials: Experimental group(n=5) - bilayer artifcia1 dermis ($Terudermis^{(R)}$; Terumo Co. Japan) and Control group(n=6) - free gingival graft with autogenous palatal mucosa. Biopsies were harvested at 1,2,3 and 6 weeks postsurgery to evaluate histologically. At the third week in the experimental group and at the second week of in the control group, the grafts has been clinically stabilized on the recipient bed and the graft border has been blended into the surrounding tissue. In the experimental group after 1 week of grafting, the epithelial migration from the adjacent tissue to graft material was seen and after 3 weeks of grafting, the : nflmmation decreased, collagen layer of the artificial dermis was lost and the basement membrane of epithelium was formed. After 6 weeks of grafting, both groups demonstrated orthokeratinized epithelium and increased thickness of epithelial tissue and the rete peg formation, similar to the adjacent tissue, Histologic evaluation revealed a biologic acceptance and incorporation of the collagen layers of the graft tissue to the host tissue, without foreign body reaction. In conclusion, a bilayer artificial dermis is essentially similar to autogeneous free gingival graft in the correction of mucogingival problems, and has the advantages of decreased patient morbidity (no donor site) and availability of abundant amounts of graft material when needed.