• Title/Summary/Keyword: Impact Stability

Search Result 1,030, Processing Time 0.024 seconds

The Effect of a Shock-Absorbable Polymer(Chitosan) on the Initial Stability and Dynamic Behavior of Dental Implant (충격흡수용 고분자재료의 이용이 Implant 초기안정성과 동적거동에 미치는 영향)

  • Joo, W.;Choi, K.;Kwon, I.C.;Choi, J.B.;Moon, H.J.;Shin, J.W.;Lee, Y.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.337-342
    • /
    • 1997
  • Dental implant has been increasingly used to recover the masticatory unction of tooth. It has been well known that the success of dental implant is heavily dependent on initial stability and long-term osseointegration due to optimal stress distribution in the surrounding bones. The role of periodontal ligament, removed during operation, is to absorb impact force and to distribute them to alveolar bone. or this reason, the study for artificial periodontal ligament has become an important issue in this field. In this study, chitosan was coated on dental implant or the purpose of replacing the role of intact periodontal ligament. The results by experiment and FEM analysis showed : I) Initial stability of dental implant was significantly increased(35%) when the implant was coated with chitosan. II) The coated implant showed higher impact absorption, more even stress distribution and lower stress magnitude under impact force than uncoated implant. Accordingly, the micro-fracture of the surrounding bones due to impact force would be lessened by chitosan coating on dental implant.

  • PDF

Dynamic Analysis of Long-span Arch Bridge by Fracturing Hangers (장대 아치교 행어 파단에 의한 동적 해석)

  • Yhim, Sung-Soon;Kong, Min-Sik;Yoo, Yi-Seul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.2
    • /
    • pp.113-120
    • /
    • 2010
  • Recently, various evaluations concerning structural stability under construction step and completely constructed step have been executed during a Long-span Arch Bridge designing procedure. However, the breakage of cable-hangers of arched bridge in unexpected accident or periodic cable-replacement has not been considered. Therefore, the purpose of this study is that analyzing structural safety of arched bridge when the cable-hangers being fractured by that reasons. Dynamic analysis are performed by idealizing impact load to three types of impact functions as fracturing the cables. Consequently, when the hangers are fractured, the maximum tensile force by dynamic analysis is larger than those by static analysis. Therefore, the dynamic analysis is demanded to accurately obtain the responses for the structural stability with a realistic impact loading model in the breakage and replacement of cable hangers of long-span arched bride. Moreover, the analysis method and results in this study can be used to basic criteria in design.

Marital Satisfaction and Marital Stability : A Comparison of Two Theoretical Models (결혼만족도와 결혼안정성 : 두 이론의 비교)

  • 윤경자
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.4
    • /
    • pp.31-46
    • /
    • 1997
  • The controversy between Lewis and Spanier's theory and Thomas and kleber's theory on marital satisfaction and marital stability was tested empirically. The results show that while marital satisfaction was the best predictor for marital stability the impact of alternative attractions and external pressures to remaim married was more complicated than both theories predicted depending on the nature of alternative attractions. Thomas and Kleber's theory was supported in most of groups Contrary to Lewis and Spanier's theory alternative atteractions did not negatively affect marital stability of marriages of high qulity. Contrary to both theories external pressures to remain married was not an important predictor of marital stability . In some cases high external pressures to remain married even lowered marital stability. The validity of both theories are discussed.

  • PDF

Power System Sensitivity Analysis for Probabilistic Small Signal Stability Assessment in a Deregulated Environment

  • Dong Zhao Yang;Pang Chee Khiang;Zhang Pei
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.spc2
    • /
    • pp.355-362
    • /
    • 2005
  • Deregulations and market practices in power industry have brought great challenges to the system planning area. In particular, they introduce a variety of uncertainties to system planning. New techniques are required to cope with such uncertainties. As a promising approach, probabilistic methods are attracting more and more attentions by system planners. In small signal stability analysis, generation control parameters play an important role in determining the stability margin. The objective of this paper is to investigate power system state matrix sensitivity characteristics with respect to system parameter uncertainties with analytical and numerical approaches and to identify those parameters have great impact on system eigenvalues, therefore, the system stability properties. Those identified parameter variations need to be investigated with priority. The results can be used to help Regional Transmission Organizations (RTOs) and Independent System Operators (ISOs) perform planning studies under the open access environment.

Comparative Study on Cupping Apparatuses for Medical Use by Mechanical Stability and Functional Test (수동식 부항기의 기계적 안정성과 성능의 실험적 비교연구)

  • Soh, Mun-Gie;Song, Yun-Kyung;Lim, Hyung-Ho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.18 no.2
    • /
    • pp.157-167
    • /
    • 2008
  • Objectives : It is sure that standardization of medical instruments is very important and necessary. Cupping therapy is one of the traditional oriental medical method, and it is necessary to set up a standard of cupping therapy and instruments. Methods : We select 3 major cupping instrument makers according to a questionnaire survey of 2001 oriental medical doctors. Dae Gun is A maker, Han Sol is B maker, Dong Bang is C maker. And with these air pumps we make experiments on stability by an inner impact test and a falling test. With these cups we check stability by an inner impact test and a disinfection test. And to know function of these instruments we test a negative pressure and maintain attached cups until 5 to 10minutes. Results : All results of experiments(impacted test, disinfection test, falling test) on stability of cups and air pumps are suitable for medical instrument. And the efficiency of 3 major makers shows various results. Negative pressure of B group is the highest, C group is the second, A group is the lowest. Pressure maintenance test shows A and C group is comparatively up to the experimental standard(<10%), B group is comparatively below the experimental standard(<10%). Conclusions : Results show stability of cups and air pumps is suitable for medical instruments. And negative pressure of cupping and maintenance of pressure show various results. So it is necessary to set up a standard negative pressure of cupping and maintenance of pressure.

Effect of variation of water retention characteristics due to leachate circulation in municipal solid waste on landfill stability

  • M. Sina Mousavi;Yuan Feng;Jongwan Eun;Boo Hyun Nam
    • Geomechanics and Engineering
    • /
    • v.33 no.2
    • /
    • pp.141-154
    • /
    • 2023
  • This study investigated the effect of water retention characteristics between aged and fresh Municipal Solid Waste (MSW) on the stability of the landfill. A series of transient numerical modeling for the slope of an MSW landfill was performed considering the variation of water retention characteristics due to leachate circulation. Four different scenarios were considered in this analysis depending on how to obtain hydraulic conductivity and the aging degree of materials. Unsaturated hydraulic properties of the MSW used for the modeling were evaluated through modified hanging column tests. Different water retention properties and various landfill conditions, such as subgrade stiffness, leachate injection frequency, and gas and leachate collection system, were considered to investigate the pore water distribution and slope stability. The stability analyses related to the factor of safety showed that unsaturated properties under those varied conditions significantly impacted the slope stability, where the factor of safety decreased, ranging between 9.4 and 22%. The aged materials resulted in a higher factor of safety than fresh materials; however, after 1000 days, the factor of safety decreased by around 10.6% due to pore pressure buildup. The analysis results indicated that using fresh materials yielded higher factor of safety values. The landfill subgrade was found to have a significant impact on the factor of safety, which resulted in an average of 34% lower factor of safety in soft subgrades. The results also revealed that a failed leachate collection system (e.g., clogging) could result in landfill failure (factor of safety < 1) after around 298 days, while the leachate recirculation frequency has no critical impact on stability. In addition, the accumulation of gas pressure within the waste body resulted in factor of safety reductions as high as 24%. It is essential to consider factors related to the unsaturated hydraulic properties in designing a landfill to prevent landfill instability.

Study on the Optimization Design and Impact Experiment of Side Door for Impact Beam in the Vehicle Side Door (차량 측면도어 임팩트 빔의 최적설계 및 측면도어 충돌실험에 관한 연구)

  • Kim, Jae Yeol;Choi, Soon Ho
    • Tribology and Lubricants
    • /
    • v.31 no.1
    • /
    • pp.13-20
    • /
    • 2015
  • The impact beam, a beam-shaped reinforcement installed horizontally between the inside and outside panels of car doors, is gaining importance as a solution to meet the regulations on side collision of vehicles. In order to minimize pelvis injury which is the biggest injury happening to the driver and passengers when a vehicle is subject to side collision, energy absorption at the door impact beam should be maximized. For the inner panel, the thrust into the inside of the vehicle must be minimized. The impact beam should be as light as possible so that the extent of pelvis injury to the driver and passenger during side collision of the vehicle is minimal. To achieve this, the weight of the impact beam, has to be optimized. In this study, we perform a design analysis with a goal to reduce the weight of the current impact design by 30% while ensuring stability, reliability, and comparison data of the impact beam for mass production. We conduct three-point bending stress experiments on conventional impact beams and analyze the results. In addition, we use a side-door collision test apparatus to test the performance of beams made of three (different materials: steel, aluminum, and composite beams).

The relationship between dental implant stability and trabecular bone structure using cone-beam computed tomography

  • Kang, Se-Ryong;Bok, Sung-Chul;Choi, Soon-Chul;Lee, Sam-Sun;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Tae-Il;Yi, Won-Jin
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.2
    • /
    • pp.116-127
    • /
    • 2016
  • Purpose: The objective of this study was to investigate the relationships between primary implant stability as measured by impact response frequency and the structural parameters of trabecular bone using cone-beam computed tomography(CBCT), excluding the effect of cortical bone thickness. Methods: We measured the impact response of a dental implant placed into swine bone specimens composed of only trabecular bone without the cortical bone layer using an inductive sensor. The peak frequency of the impact response spectrum was determined as an implant stability criterion (SPF). The 3D microstructural parameters were calculated from CT images of the bone specimens obtained using both micro-CT and CBCT. Results: SPF had significant positive correlations with trabecular bone structural parameters (BV/TV, BV, BS, BSD, Tb.Th, Tb.N, FD, and BS/BV) (P<0.01) while SPF demonstrated significant negative correlations with other microstructural parameters (Tb.Sp, Tb.Pf, and SMI) using micro-CT and CBCT (P<0.01). Conclusions: There was an increase in implant stability prediction by combining BV/TV and SMI in the stepwise forward regression analysis. Bone with high volume density and low surface density shows high implant stability. Well-connected thick bone with small marrow spaces also shows high implant stability. The combination of bone density and architectural parameters measured using CBCT can predict the implant stability more accurately than the density alone in clinical diagnoses.

The Effect of Bank Liquidity on Bank's Stability in the Presence of Managerial Optimism

  • HABIB, Ashfaq;KHAN, Muhammad Asif;MEYER, Natanya
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.9 no.8
    • /
    • pp.183-196
    • /
    • 2022
  • Bank stability serves as a prerequisite for the smooth functioning of economic and financial activities in the country. Banks face numerous risks, and liquidity plays an essential role in determining a bank's long-term growth and financial stability. By using the sample of 70 banks of the Gulf Cooperation Council, this study examines the association between funding the liquidity and the creation of liquidity and their impact on bank stability. Firstly, the reciprocal relationship reveals between funding the liquidity and the creation of liquidity by employing the 2SLS regression model. Further, by employing the dynamic GMM model, the research finds that funding liquidity is significant and positively influences bank stability. However, bank stability is significantly negatively influenced by the creation of liquidity, but the combined effect of funding the liquidity and creation of liquidity positively explains the bank stability. Additionally, this study reveals that managerial optimism biases contribute to determining the bank's liquidity and long-term stability. The finding of this study supports the executives, policymakers, and management of banks in understating liquidity risks, efficiency, and bank stability. The findings support regulatory guidelines mainly by the Basel III framework, which places more importance on the joint management of funding the liquidity and creation of liquidity in the economy.

Design and Impact Testing of Cylindrical Composite-Antenna-Structures having High Mechanical Performanc (기계적 특성이 우수한 원통형 복합재료 안테나의 설계 및 충격 실험)

  • Kim, Dong-Seop;Jo, Sang-Hyeon;Hwang, Un-Bong;Lee, Jung-Hui
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.35-38
    • /
    • 2005
  • The Objective of this work was to design Composite Antenna Structures (CAS) and investigate impact behavior of CAS which was various curvature. This term, CAS, indicates that structural surface becomes antenna. Constituent materials were selected considering electrical properties, dielectric constants and tangent loss as well as mechanical properties. For the antenna performance, microstrip antenna layers inserted into structural layers were designed for satellite communication at the resonant frequency of 12.5 GHz and final demonstration article was. After making five kinds of curved CAS, which radii of curvature are flat, 200, 150, 100, 50 mm. The antenna performance changed in accordance with variation of curvature. The Reflection coefficient was independent of curvature but the gain decreased with the radius of curvature. The impact test equipment was Dyna-8250 drop weight tester. The impact characteristic in accordance with curvature is maximum absorb energy is same each other. The impact energy was 8.5 J. For various Impact energy test, five energy levels 3 J, 5 J, 7 J, 10 J, 20 J were used. The performance of impact damaged antenna was estimated by measuring the return loss and the radiation pattern. It was revealed that the performance of antenna was not related to the impact damage. Because the impactor did not damage the patch directly. CAS have good impact stability for the antenna performance.

  • PDF