• 제목/요약/키워드: Impact Sound

검색결과 636건 처리시간 0.023초

바닥충격음 저감방안에 따른 성능평가 (Evaluation of Floor Impact Sound Performance according to the Reduction Methods)

  • 김경우;최경석;최현중;양관섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.131-136
    • /
    • 2004
  • Impact sounds, such as those created by footsteps, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. The character and level of impact noise generated depends on the object striking the floor, on the basic structure of the floor, and on the floor covering. This study base on the evaluate of isolation performance of impact sound according to the impact noise reduction methods. Reduction methods consist of four ways. First way is increase thickness of bare floor and other ways are using the soft coverings on the floor and ceiling assembles. Last way is make floating floor with shock absorbing materials.

  • PDF

바닥충격음 저감방안에 따른 성능평가 (Evaluation of Floor Impact Sound Performance according to the Reduction Methods)

  • 최경석;최현중;양관섭;김경우
    • 한국소음진동공학회논문집
    • /
    • 제14권9호
    • /
    • pp.811-818
    • /
    • 2004
  • Impact sounds, such as those created by footsteps, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. The character and level of impact noise generated depends on the object striking the floor, on the basic structure of the floor, and on the floor covering. This study base on the evaluate of isolation performance of impact sound according to the impact noise reduction methods. Reduction methods consist of four ways. First way is increase thickness of bare floor and other ways are using the soft coverings on the floor and ceiling assembles. Last way is make floating floor with shock absorbing materials.

건식 바닥구조의 바닥충격음 차단성능 평가 (Evaluation of Floor Impact Sound Isolation in a Dry Floor System)

  • 유진;류종관;전진용;이충화;김철환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.950-953
    • /
    • 2005
  • Floor impact sounds from two different floor systems were measured. One of the two floor systems is a dry floor system (with 150mm concrete slab) and the other is a standard floor system (210mm concrete slab). Real impact sources such as jumping and running of children were used as well as standard impact sources (bang machine, impact ball and tapping machine) to evaluate sound Isolation of the two floor systems. Subjective evaluations of the floor impact sound isolation performance for the two systems were also conducted by the methods of 3 scales & 9 categories, paired comparison and semantic differentials. Measurement results indicate that floor impact sound isolation performance of the dry floor was better than that of standard floor in both cases of real and standard impact sources. The subjects in auditory experiments also evaluated the dry floor as a better sound isolation system.

  • PDF

층간소음 평가를 위한 임팩트 볼의 활용 (Use of Impact Ball for Evaluation of Floor Impact Sound)

  • 전진용;정정호;이평직
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.808-811
    • /
    • 2005
  • To use the impact ball as a new standard floor impact source, the objective and subjective properties of the impact bali were investigated. The results showed that not only the objective properties of the impact ball such as the Impact force exposure level, mechanical impedance but also the psychological parameters were more similar to those of the human impact than the bang machine. In addition, most of the subjects chose the impact bail sound as the most similar sound to the human impact sound in the auditory experiment.

  • PDF

바닥충격음 저감이 가능한 천장 공법 개발 (Development of ceiling construction methods reduced floor impact sound)

  • 김경호;김성훈;류종관;이종인;김용민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.203-207
    • /
    • 2014
  • According to the advanced study, Increase of ceiling air space could cause increase of floor impact sound by air-spring effect. So in this research, we studied the increase of floor impact sound caused by ceiling air space in apartment buildings. At first, we evaluated the change of floor impact noise in the condition of with or without ceiling air-space. And then we installed perforated ceiling systems and glass wool at ceiling area. we expected that perforated ceiling systems could prevent air-spring effect in ceiling space. As a result, ceiling air space caused increasement of floor heavy impact noise about 2~4dB. But perforated ceiling & sound-absorbing materials system could give us reduction of heavy floor impact noise about 3dB. So this systems could be a good alternative to obey national regulations, because it can reduce heavy impact noise additional to floating floor systems.

  • PDF

신축공동주택의 상하층간 소음 및 진동전달 특성과 층간소음 차단성능에 관한 연구 (Study on the Characteristic of Floor Sound and Vibration Transfer and the Blocking Function of Floor Sound for Newly Built Apartment House)

  • 함진식
    • 한국주거학회논문집
    • /
    • 제24권2호
    • /
    • pp.97-104
    • /
    • 2013
  • This study involves 2 newly built apartment houses which are A with 23 floors as 150 mm slab width and B with 16 floors as 180 mm slab width. The impact was added by tapping and bang machine at the middle floor level of these 2 apartments and the test was arranged in terms of the characteristic of vibration and sound level which transferred to upper or down floors. As a result, impact floor shows the highest value in terms of both sound and vibration level and followed was at down floor of the Impact floor. Also, blocking function for the lightweight and heavyweight floor impact sound level was tested for each room of the apartment A and B including living room, main room, room 1 and 2. As a result, sound blocking function of B apartment was better than that of A and the function was getting worse when the room size is getting smaller.

완충재 구성방법에 따른 동탄성계수 및 중량바닥충격음 저감특성 평가 (Evaluation of the Dynamic Stiffness and Heavy-weight Floor Impact Sound Reduction by Composition of Resilient Materials)

  • 김경우;정갑철;손장열
    • 한국소음진동공학회논문집
    • /
    • 제18권2호
    • /
    • pp.247-254
    • /
    • 2008
  • Resilient materials are generally used for the floating floors to reduce the floor impact sound. Dynamic stiffness of resilient material, which has the most to do with the floor impact sound reduction. The resilient materials available in Korea include EPS(styrofoam), recycled urethane types, EVA(ethylene vinylacetate) foam rubber, foam PE(polyethylene). glass fiber & rock wool, recycled tire, foam polypropylene. compressed polyester, and other synthetic materials. In this study, we tested dynamic stiffness of resilient material and floor impact sound reduction characteristic to a lot of kinds of resilient materials. It was found that dynamic stiffness of multi-layered damping material could be estimated if know value of each layer that compose whole structure. And the test showed that the amount of the heavy-weight impact sound reduction appeared by being influenced from this dynamic stiffness of resilient material. The dynamic stiffness looked like between other resilient materials, a similar to the amount of the heavy-weight impact sound reduction was shown.

타격음을 이용한 복합재료 구조물의 손상탐지법의 개발 (Development of Damage Detection Technique in Laminated Composites using Tapping Sound)

  • 김승조;황준석;송준영
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 춘계학술발표대회 논문집
    • /
    • pp.171-174
    • /
    • 2000
  • In this paper, impact sound realization of composite structures is performed to investigate the possibility of a new NDE system - Tapping Sound Analysis (TSA). TSA detects the existence of damages inside the structures by comparing tapping sound with pre-computed sound data of healthy structures. Tapping on the structures is modeled as impact problem and solved using finite element method. Calculation of sound is formulated based on the coupled finite element and boundary element method. Numerical simulation of impact sound and feature extraction scheme show that the impact sound can be used in the identification of damages of laminated composites.

  • PDF

임팩트 볼에 의한 바닥충격음 측정 및 평가 간편법 (Simplified method on measurement and evaluation of floor impact sound using impact ball)

  • 김용희;이신영;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.631-635
    • /
    • 2006
  • In this study, simplified methods on measurement and evaluation of heavy-wight impact sound was proposed due to provide easy quality control method to construction engineers. The simplified methods include using of rubber impact ball instead of bang machine, reduced number of measuring and impact positions which is prescribed as over 4 points, using of hand-held sound level meter as a frequency analyser and prediction equation for $L_{i.Fmax.AW}$, single number rating, using $L_{Amax}$, and $L_{Lmax}$ at each frequency band. The results showed that a method of boundary driving and boundary measuring is the most similar to the current rating method.

  • PDF

슬래브 상부 몰탈층에 사용된 작은시편의 유효성 검토(중량충격음을 중심으로) (Small-size Specimen's Effectiveness That is Used to Mortar Layer of Slab (Heavy-weight Floor Impact Sound))

  • 정진연
    • 한국소음진동공학회논문집
    • /
    • 제19권2호
    • /
    • pp.184-191
    • /
    • 2009
  • This study examined small-size specimen's effectiveness that is used to evaluate floor impact sound performance. Floor impact sound level of small-size specimen is higher than full-size. This is due to excessive impact power of Bang machine. Impact hammer that has small impact power relatively can solve this problem. But, according to the size of specimen, mode shape and frequency that influence to structural borne sound is changed. Slab mode of full-size specimen was changed to frequency design of resilient materials. But in case of small-size specimen, there is no change of vibration mode by resilient materials change, Vibration mode of small-size specimen is the same. Therefore, it is not proper that use small-size specimen in floor impact sound estimation.