• Title/Summary/Keyword: Immunity Test

Search Result 254, Processing Time 0.028 seconds

Immunity Test for Semiconductor Integrated Circuits Considering Power Transfer Efficiency of the Bulk Current Injection Method

  • Kim, NaHyun;Nah, Wansoo;Kim, SoYoung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.2
    • /
    • pp.202-211
    • /
    • 2014
  • The bulk current injection (BCI) and direct power injection (DPI) method have been established as the standards for the electromagnetic susceptibility (EMS) test. Because the BCI test uses a probe to inject magnetically coupled electromagnetic (EM) noise, there is a significant difference between the power supplied by the radio frequency (RF) generator and that transferred to the integrated circuit (IC). Thus, the immunity estimated by the forward power cannot show the susceptibility of the IC itself. This paper derives the real injected power at the failure point of the IC using the power transfer efficiency of the BCI method. We propose and mathematically derive the power transfer efficiency based on equivalent circuit models representing the BCI test setup. The BCI test is performed on I/O buffers with and without decoupling capacitors, and their immunities are evaluated based on the traditional forward power and the real injected power proposed in this work. The real injected power shows the actual noise power level that the IC can tolerate. Using the real injected power as an indicator for the EMS test, we show that the on-chip decoupling capacitor enhances the EM noise immunity.

Modeling and Prediction of Electromagnetic Immunity for Integrated Circuits

  • Pu, Bo;Kim, Taeho;Kim, SungJun;Kim, SoYoung;Nah, Wansoo
    • Journal of electromagnetic engineering and science
    • /
    • v.13 no.1
    • /
    • pp.54-61
    • /
    • 2013
  • An equivalent model has been developed to estimate the electromagnetic immunity for integrated circuits under a complex electromagnetic environment. The complete model is based on the characteristics of the equipment and physical configuration of the device under test (DUT) and describes the measurement setup as well as the target integrated circuits under test, the corresponding package, and a specially designed printed circuit board. The advantage of the proposed model is that it can be applied to a SPICE-like simulator and the immunity of the integrated circuits can be easily achieved without costly and time-consuming measurements. After simulation, measurements were performed to verify the accuracy of the equivalent model for immunity prediction. The improvement of measurement accuracy due to the added effect of a bi-directional coupler in the test setup is also addressed.

Construction of Large 3-axis Square Helmholtz Coil system for the Power Frequendy Magnetic Field Immunity Test (전원주파수 교류자기장 내성평가용 대형 3-축 사각 헬름홀쯔 코일 시스템 제작)

  • 유권상;김창석;정낙삼
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.905-909
    • /
    • 1995
  • We constructed the large 3-axis square Helmholtz coil system for the power frequency magnetic field immunity test. We measured the coil factors and magnetic field homogeneities of the fabricated 3-axis square Helmholtz coil. The experimental results for the field homogeneities are in agreement with the theoretical data. From these results, we determined the effective areas for the immunity test. We also confirmed that the low current using the multi-turns coil can be applicable to the immunity test for the high field in short duration.

  • PDF

Enhanced immunity effect of Korean Red Ginseng capsule: A randomized, double-blind and placebo-controlled clinical trial

  • Yi Yang;Jing Li;Shengyuan Zhou;Daoyan Ni;Cailing Yang;Xu Zhang;Jian Tan;Jingrui Yan;Na Wang
    • Journal of Ginseng Research
    • /
    • v.48 no.5
    • /
    • pp.504-510
    • /
    • 2024
  • Background: As a physiological function of body, immunity can maintain health by identifying itself and excluding others. With economic development and increasingly fierce social competition, the number of sub-healthy population is gradually increasing, and the most basic problem exposed is human hypoimmunity. Hypoimmunity can be manifested as often feeling tired, catching colds, mental depression, etc. In order to enhance immunity, eating healthy foods with the effect of enhancing immunity may become an effective choice. KRG has pharmacological effects of enhancing immunity. Because the screening and evaluation method of immune population are not unified, there are relatively few KRG immunity tests for sub-health population. It is of great significance to study the effect of KRG on people with hypoimmunity to improve sub-health status. Methods: This was a 180-day, randomized, double-blind, placebo-controlled clinical trial. According to the trial scheme design, 119 qualified subjects were included and randomly divided into the test group taking KRG and the placebo control group. Subjects need to check safety indicators (blood pressure and heart rate, blood routine, liver and kidney function, urine routine and stool routine) and efficacy indicators (main and secondary) inspection at baseline, efficacy indicators inspection during the mid-term of the test (90th days of administration), safety and efficacy indicators inspection after the test (180th days of administration). Results: After the test, the safety indicators of placebo control group and KRG test group were basically within the normal range, and there is no significant difference in fireness score between the two groups. Through follow-up interviews, it was found that the subjects in the test group and the control group had no adverse reactions and allergic reactions such as nausea, flatulence, diarrhea, and abdominal pain during the test period. Self-comparison of the test group, the results of the main efficacy indicators: (1) immune related health scores were significantly improved in the mid-term and after the test (P < 0.01), (2) CD3 and CD4/CD8 increased significantly after the test (P < 0.05), (3) IgG, IgA, IgM and WBC increased significantly in the mid-term and after the test (P < 0.01); the results of the secondary efficacy indicators: (1) TNF-α decreased significantly in the midterm (P < 0.05), IFN-γ decreased significantly in the mid-term (P < 0.01), (2) NK increased significantly in the mid-term and after the test (P < 0.05), (3) monocyte increased significantly in the mid-term and after the test (P < 0.01). Inter-group comparison of the test group and the control group, the results of the main efficacy indicators: (1) immune related health scores were higher than that of the control group in the mid-term and after the test (P < 0.01), (2) IgA of the test group was higher than that of the control group in the mid-term and after the test (P < 0.05); the results of the secondary efficacy indicators: (1) WBC of the test group was higher than that of the control group in the mid-term (P < 0.05); (2) monocytes of the test group were higher than that of the control group in the mid-term and after the test (P < 0.05), neutrophils of the test group were higher than that of the control group in the mid-term (P < 0.05). Conclusion: Taking KRG has no adverse effects on the health of the subjects. According to the standard of clinical trial scheme, the immune related health scores and IgA in the main efficacy indicators were positive, which shows that KRG is helpful in enhancing human immunity.

Analysis of Reference Signal for Immunity Test of Sound System and Television Broadcast Receiver (음향 기기 및 TV 방송 수신기의 내성 시험용 기준 신호 분석)

  • Choi, Su-Na;Cho, Sung-Woong;Park, Seung-Keun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.7
    • /
    • pp.805-814
    • /
    • 2012
  • Intermittent or periodic signals with undulating amplitudes of mobile devices cause interference noise at audible frequency to the sound system which is installed nearby. In this regard, it is recently issued that the intermittently transmissions of LTE mobile phones cause the interference noises with sound systems, similar to that of GSM mobile phones. For retaining the immunity to noises, a national regulation KN20 suggests a 1 kHz AM 80 % and a CDMA modulation signal as reference signals for immunity test of sound and television broadcast receiver. In this paper, the effects of interference noises of AM and CDMA are compared with those of GSM and LTE, and the improvement of reference signal for national immunity test of sound systems is suggested. It is recommended to delete the CDMA modulation signal from reference signals for immunity test because it hardly cause interference noise with sound systems. On the other hand, it is desirable to select the modulation signal of LTE instead of CDMA as a reference signal for immunity test of sound system and television broadcast receiver because many people use the LTE service and it is analysed that the LTE signal causes considerable interference noises.

Effects of GamiBangkeehwangkee-tang (fángjǐhuángqí-tāng) ethanol extract on Collagen-induced Rheumatoid Arthritis model of DBA/1 mice (가미방기황기탕(加味防己黃芪湯) 주정 추출물이 류마티스 관절염 동물병태모델에 미치는 영향)

  • Sim, Boo-Yong;Choi, Hak-Joo;Bak, Ji-Won;Kim, Dong-Hee
    • The Korea Journal of Herbology
    • /
    • v.29 no.6
    • /
    • pp.95-102
    • /
    • 2014
  • Objectives : The purpose of this study is to prove the effect of GamiBangkeehwangkee-tang (f$\acute{a}$ngj$\check{i}$hu$\acute{a}$ngq$\acute{i}$-t$\bar{a}$ng, BHT) ethanol extract on the immunity and rheumatoid arthritis related inflammatory cytokines. Methods : We checked viability in RAW 264.7 cell after treat by BHT. Then we measured inflammatory and immunity factors of DBA/1 mice with rheumatoid arthritis induced by collagen after BHT oral administration. Also, we checked micro-CT image, bone volume and bone inflammation ratio in micro-CT and structural parameter test. Results : BHT showed cell viability of 95% or higher in all concentration in RAW 264.7 cells. BHT treated group decreased level in serum of IgM and IgG test by 36% and 25% respectively. And BHT treated group showed significant decrease in WBC, neutrophil, lymphocyte and monocytes immune cell ratio in blood by 47%, 22%, 56% and 85% respectively. Also, BHT treated group decreased level in serum of $IL-1{\beta}$, IL-6, IL-17, $TNF-{\alpha}$ and hs-CRP tests by 29%, 33%, 32%, 24% and 56% respectively. Finally, BHT treated group showed increase ratio of bone volume that decrease ratio of bone inflammation. Conclusions : In this study, the results were observed rheumatoid arthritis factors cytokine decrease in serum. And BHT showed immunoglobulin and immune cells ratio decrease in serum and blood. Also, BHT depending on effects of inflammatory and immunity in hs-CRP test, micro-CT, structural parameter test. Thus, these results can used as a effective drug of BHT for inflammation and immunity.

A Study on the Electromagnetic Compatibility Evaluation of the Electronic Medical Instrumentation (전자의료기기의 전자파 적합성 평가에 관한 연구)

  • Song, C.G.;Kim, J.C.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.418-421
    • /
    • 2002
  • The immunity testing in this study was performed to examine the conducted immunity and radiated immunity in medical instrumentation. Experiments were performed to assess the conducted emission and radiated emission of medical instrumentation such as MRI, ultrasound system, and electro surgical unit etc. The emission testing revolves around conducted emissions (high-frequency currents) on power lines and signal cables. Emission testing also looks at the output of energy through the air (called radiated emissions) and analyzes the strength of those radio-frequency signals generated unintentionally by the electrical medical device that is under test. Finally, this study would provide significant data for furture research or electromagnetic interference and compatibility test in medical instrumentation.

  • PDF

Stress mode proposal for an efficient ESD test (효율적인 ESD(ElectroStatic Discharge) test를 위한 Stress mode 제안)

  • Gang, Ji-Ung;Chang, Seog-Weon;Kwack, Kae-Dal
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1289-1294
    • /
    • 2008
  • Electrostatic discharge(ESD) phenomenon is a serious reliability concern. It causes approximately most of all field failures of IC. To quality the ESD immunity of IC product, there are some test methods and standards developed. ESD events have been classified into 3 models, which are HBM, MM and CDM. All the test methods are designed to evaluate the ESD immunity of IC products. This study provides an overview among ESD test methods on ICs and an efficient ESD stress method. We have estimated on all pin combination about the positive and negative ESD stress. We make out the weakest stress mode. This mode called a worst-case mode. We proposed that positive supply voltage pin and I/O pin combination is efficient because it is a worst-case mode.

  • PDF

DTMOS Schmitt Trigger Logic Performance Validation Using Standard CMOS Process for EM Immunity Enhancement (범용 CMOS 공정을 사용한 DTMOS 슈미트 트리거 로직의 구현을 통한 EM Immunity 향상 검증)

  • Park, SangHyeok;Kim, SoYoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.10
    • /
    • pp.917-925
    • /
    • 2016
  • Schmitt Trigger logic is a gate level design method to have hysteresis characteristics to improve noise immunity in digital circuits. Dynamic Threshold voltage MOS(DTMOS) Schmitt trigger circuits can improve noise immunity without adding additional transistors but by controlling substrate bias. The performance of DTMOS Schmitt trigger logic has not been verified yet in standard CMOS process through measurement. In this paper, DTMOS Schmitt trigger logic was implemented and verified using Magna $0.18{\mu}m$ MPW process. DTMOS Schmitt trigger buffer, inverter, NAND, NOR and simple digital logic circuits were made for our verification. Hysteresis characteristics, power consumption, and delay were measured and compared with common CMOS logic gates. EM Immunity enhancement was verified through Direct Power Injection(DPI) noise immunity test method. DTMOS Schmitt trigger logics fabricated using CMOS process showed a significantly improved EM Immunity in 10 M~1 GHz frequency range.

A Study About the Application Feasibility of EMS IEC 61000-4-6 Test Standard on Electronic Power Meter (전자식 계기 IEC 61000-4-6 EMS 시험표준 적용 타당성 연구)

  • Kim, Seok-Gon;Park, Chang-Ho;Shin, Dong-Yeol;Song, Tae-Seung;Choi, Yong-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1261-1267
    • /
    • 2011
  • Electricity meters using in Korea are about 1.8 million units. From among these, electronic meters for high voltage, about 170 thousand units were installed to the digital type meter and ones for low voltage installed hundreds of thou-sands of meters through a model project. Recently, low voltage meter are expected to complete the installation within several years. Domestic power metering technology is being beyond a simple framework with an electronic type and is rapidly evolving to intelligent smart metering systems in conjunction with promotion of a national smart grid project. Accordingly, it is important to ensure an immunity of meter for electromagnetic field and environmental noise at the installation site. In this paper, we are going to check the validity of international standard that focusing on RF electromagnetic field immunity of meter to secure the quality and improve the reliability in field operation of meter. And we will verify the validity of test specification focused on actual installation environment and are going to offer the improvement plan of test standard.