• Title/Summary/Keyword: Immediately loading

Search Result 98, Processing Time 0.028 seconds

STABILITY CHANGES OF IMMEDIATELY LOADED AND DELAYED LOADED IMPLANTS IN EDENTULOUS MANDIBLE (하악 무치악에서 즉시하중과 지연하중간 임플랜트의 안정성 변화)

  • Jung, Hye-Eun;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra;Yi, Yang-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.250-262
    • /
    • 2007
  • Statement of problem: It was reported high success rate of implant-supported fixed prostheses using with $5{\sim}6$ implants on anterior mandible. Recently, immediate loading protocol was focused to overcome disadvantages of classic 2-stage delayed loading protocol. Purpose: This clinical study was to evaluate stability changes with time of immediately loaded and delayed loaded implants in edentulous mandible and to compare stability changes with time according to implantation sites. Materials and methods: Five or six implants were placed on anterior mandible depending on the arch shape. The immediately loading group was consisted of 8 patients received their prostheses within $24{\sim}48$ hours after implantation. The delayed loading group was consisted of 8 patients received their definitive prostheses following classical prosthetic procedures after a healing period of 3 months. All patients were recalled every 6 months for check-up. The evaluations of radiographic examination, ISQ value measurement and recording of complication were done. To evaluate marginal bone level, intraoral periapical radiographs were taken with long cone paralleling technique. At every evaluation recall, all prostheses were removed and ISQ values were measured with OsstellTM on individual implants. Results: 1. None of implants was failed. All implants showed stable marginal bone levels and ISQ values. 2. Marginal bone level changes with time showed statistically significant difference between immediately loading group and delayed loading group (P<0.001). 3. ISQ value changes with time did not show statistically significant difference between immediately loading group and delayed loading group (P=0.079). ISQ value decreased with time in both groups, however, all implants showed stable ISQ value at 30 months-recall evaluation. 4. Marginal bone level changes with time did not show statistically significant differences among implantation sites (P=0.604). 5. ISQ value changes with time showed statistically significant differences among implantation sites (P=0.047). ISQ values of most posterior implants decreased with time comparing to other implants. Conclusion: Although the marginal bone level of the terminal abutment didn't different with the other implants, ISQ value of the terminal abutment was lower than that of the other implants. Therefore, further clinical evaluation would be needed in this point of view.

Marginal bone level change during sequential loading periods of partial edentulous rehabilitation using immediately loaded self-tapping implants: a 6.5-year retrospective study

  • Wang, Jing;Zhang, Zhengchuan;Deng, Feilong
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.3
    • /
    • pp.133-142
    • /
    • 2022
  • PURPOSE. A large number of studies have suggested the practicability and predictability of immediate implant function, but few studies have reported marginal bone level changes during sequential loading periods. The purpose of this study was to evaluate the marginal bone remodeling of immediately loaded self-tapping implants both at each time point and during each loading period between two time points. MATERIALS AND METHODS. The patients included in this retrospective study were treated with immediately loaded NobelSpeedy Replace implants between August 2008 and July 2009. Differences in the marginal bone level (MBL) at each time point and the marginal bone level change (ΔMBL) between two time points were analyzed with Bonferroni correction (P < .05). RESULTS. Overall, 24 patients (mean age, 47.3 ± 12.8 years) with 42 immediately loaded implants and a median follow-up of 6.5 years (IQR, 67.8 months) were included. The cumulative survival rate after 10 - 12 years was 95.2%. Continuous but slow marginal bone loss was observed during long-term follow-up. MBL at both 7.5 years and 11 years was significantly lower than that at loading, 6 months, 2 years and 4 years (P < .05). No bone loss difference was found in any period before 4 years of follow up (P > .05). The loading period of 4 years to 7.5 years showed the largest ΔMBL compared to those of other time periods (P < .05). CONCLUSION. Slight bone loss occurred continuously, and more radical changes of marginal bone can be observed during the period of 4-7.5 years. Thus, long-term effective follow-up of immediately loaded implants is needed.

A Heuristic for the Realtime Ship Load Planning in Container Terminal (컨테이너 터미널에서 실시간 선적계획을 위한 발견적 해법)

  • Seo Kyung-Moo;Lee Jong-Ho;Shin Jae-Young
    • Journal of Navigation and Port Research
    • /
    • v.30 no.6 s.112
    • /
    • pp.491-498
    • /
    • 2006
  • In container terminals ship loading plan for efficient loading is made before the ship arrives. But after the ship arrives sometimes real loading state of the ship is different from planned loading state. Or sometimes the plan is not available. Hence ship loading plan must be adjusted immediately and that algorithm must be studied. In this study we organize the situations said before. And we present realtime ship loading plan method. The method is suitable for the situations, rational, and immediately able to use.

The effects of Sam-chool-gun-bi-tang administration on urine metabolic responses during carbohydrate loading diet to long distance runners (탄수화물 부하식이요법시 삼출건비탕(蔘出健脾湯) 투여가 시합 전·후 장거리 달리기 선수의 뇨중 대사 성분 변화에 미치는 영향)

  • Han, Young-Gyu;Lee, Myeong-Jong
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.8 no.2
    • /
    • pp.83-96
    • /
    • 2000
  • Objective This experimental study was designed to investigate effects of Sam-chool-gun-bi-tang administration during carbohydrate loading diet to long distance runners on changes of the urine metabolic responses. Materials and Methods All subjects were divided randomly with two groups, Sam-chool-gun- bi-tang administration Group (N=5) and control group (N=5) and attended on domestic marathon race. The urine samples were collected by 15ml conical tube at rest, a day before race, immediately after race, a day after race. These samples were used to analyze for the factors of the change on metabolic responses. At First, the factors of the routine urine test were checked; RBC, WBC, glucose, protein, ketone, bilirubin, urobilirubin. Next, the factors on the changes of the electrolyte metabolism and creatinine were checked; $Na^+ $, $Cl^-$, $K^+$, $Ca^{+ +}$, Creatinine. Results 1. Urine RBC, WBC, glucose, protein, ketone, bilirubin, urobilirubin were all denoted negatively (-). 2. Urine pH response in Sam-chool-gun-bi-tang administration group was shown significant difference between two groups at immediately after race. 3. Urine $Na^+$ response in Sam-chool-gun- bi-tang administration group was shown significant difference between two groups at immediately after race. 4. Urine $K^+$ response in Sam-chool-gun-bi-tang administration group was shown significant difference between two groups at immediately after race and a day after race. 5. Urine $Cl^-$ response in Sam-chool-gun- bi-tang administration group was increased at immediately after race, but was not shown significant difference between two groups. 6. Urine $Ca^{+ +}$ response in Sam-chool-gun-bi-tang administration group was decreased gradually, but was not shown significant difference between two groups. 7. Urine Creatinine response in Control group was decreased significantly at immediately after race, but was not shown significant difference between two groups. Conclusion According to the above results, it was shown that Sam-chool-gun- bi-tang administration had the positive effects on changes of the urine matabolic responses during carbohydrate loading diet to the long distance runners.

  • PDF

Evaluation of the Osseointegration in Immediatedly Loaded Implants in the Premolar Socket of the Mandible in Beagles (비글견에서 아래턱 작은어금니 Implant의 즉시 부하에 대한 평가)

  • Kim, Dae-Jin;Kim, Jung-Eun;Seong, Yun-Sang;Jang, Hwan-Soo;Kwon, Young-Sam;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.27 no.1
    • /
    • pp.55-61
    • /
    • 2010
  • Tooth restoration with implant placement have been interested in modern veterinary dentistry. It is important to reduce the interval between the tooth extraction and the insertion of the implants, to determine the restoration time after implant placement in dogs The aim of the this study was to compare the bone mineral apposition rate of immediately loaded implants with an unloaded control during the early healing state in the artificial extraction mandible. In four Beagles, two premolar sockets (PM2 and PM3) of the both sides of the mandible were installed with a one stage titanium mini-implant with a length of 11 mm and a diameter of 3.37 mm immediately after tooth extraction. Provisional restroration was given to implants, 3 weeks after implant placement in the left side (immediate loading) and 12 weeks in the right side (delayed loading), respectively. Radiographic and histologic examinations were performed. Radiographic evaluation revealed no significant difference between two groups. Bone-implant contact was $47.1{\pm}8.9$ in immediate loading and $50.2{\pm}8.2$ in delayed loading, interthread bone density was $78.7{\pm}10.9$ in immediate loading and $73.1{\pm}15.5$ in delayed loading, and peri-implant bone density was $95.4{\pm}7.1$ in immediate loading and $95.0{\pm}5.2$ in delayed loading, respectively. Three histologic analyses showed no significant difference between delayed and immediate loading. Followed by this study, the immediate loading of implants insterted into fresh extraction sockets after tooth extraction could be considered in veterinary dentistry.

Marginal bony changes in relation to different vertical positions of dental implants

  • Yi, Jung-Myung;Lee, Jae-Kwan;Um, Heung-Sik;Chang, Beom-Seok;Lee, Min-Ku
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.5
    • /
    • pp.244-248
    • /
    • 2010
  • Purpose: The purpose of this study was to radiographically evaluate marginal bony changes in relation to different vertical positions of dental implants. Methods: Two hundred implants placed in 107 patients were examined. The implants were classified by the vertical positions of the fixture-abutment connection (microgap): 'bone level,' 'above bone level,' or 'below bone level.' Marginal bone levels were examined in the radiographs taken immediately after fixture insertion, immediately after second-stage surgery, 6 months after prosthesis insertion, and 1 year after prosthesis insertion. Radiographic evaluation was carried out by measuring the distance between the microgap and the most coronal bone-to-implant contact (BIC). Results: Immediately after fixture insertion, the distance between the microgap and most coronal BIC was $0.06{\pm}0.68\;mm$; at second surgery, $0.43{\pm}0.83\;mm$; 6 months after loading, $1.36{\pm}0.56\;mm$; and 1 year after loading, $1.53{\pm}0.51\;mm$ ($mean{\pm}SD$). All bony changes were statistically significant but the difference between the second surgery and the 6-month loading was greater than between other periods. In the 'below bone level' group, the marginal bony change between fixture insertion and 1 year after loading was about 2.25 mm, and in the 'bone level' group, 1.47 mm, and in 'above bone level' group, 0.89 mm. Therefore, the marginal bony change was smaller than other groups in the 'above bone level' group and larger than other groups in the 'below bone level' group. Conclusions: Our results demonstrated that marginal bony changes occur during the early phase of healing after implant placement. These changes are dependent on the vertical positions of implants.

The feasibility of immediately loading dental implants in edentulous jaws

  • Henningsen, Anders;Smeets, Ralf;Wahidi, Aria;Kluwe, Lan;Kornmann, Frank;Heiland, Max;Gerlach, Till
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.4
    • /
    • pp.234-243
    • /
    • 2016
  • Purpose: Immediate loading of dental implants has been proved to be feasible in partially edentulous jaws. The purpose of this retrospective investigation was to assess the feasibility of immediately loading dental implants in fully edentulous jaws. Methods: A total of 24 patients aged between 53 and 89 years received a total of 154 implants in their edentulous maxillae or mandibles. Among the implants, 45 were set in fresh extracted sockets and 109 in consolidated alveolar bones. The implants were provisionally managed with chair-side made provisional resin bridges and exposed to immediate loading. Implants were followed up for 1-8 years, including radiographic imaging. Marginal bone levels were evaluated based on radiographic imaging. Results: A total of 148 out of the 154 implants survived over the follow-up period of 1 to 8 years, giving a survival rate of 96%. The time or region of the implantation, the pre-implant augmentation, and the length and diameter of the implants had no statistically significant influence on the survival or the success rate. The marginal bone level remained stable with only minimal loss of 0.3 mm after 60 months of loading. Conclusions: Within the limitations of this study, immediate loading is feasible for dental implants in edentulous jaws.

Clinical outcome of immediately and early loaded implants with laser treated surface: a 3-year retrospective study

  • Leesungbok, Richard;Seo, Jin-Ho;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.163-166
    • /
    • 2018
  • PURPOSE. The marginal bone loss of implants with laser treated surface was investigated after six weeks of loading after implant installation to the mandible molar area. MATERIALS AND METHODS. A total of 23 implants were placed in the edentulous molar area of the mandible: 13 implants were immediately loaded and 10 implants were early loaded. The implants used were made of titanium grade 23, screw shaped, 4.2 mm in diameter, and 10 mm in length. Patients were evaluated with resonance frequency analysis at implant fixture installation and 1, 2 (final prosthesis installation), 3, 5, 8, and 14 months later. X-rays were taken at 2 months after fixture installation and 1, 2, 3 years after to measure the marginal bone loss. RESULTS. The mean ISQ value measured at the implant installation was over 70 at all-time points. The average of marginal bone loss was average 0.33 mm. CONCLUSION. Immediate implant loading for laser treated implants would be possible.

Distributed crack sensors featuring unique memory capability for post-earthquake condition assessment of RC structures

  • Chen, Genda;McDaniel, Ryan;Sun, Shishuang;Pommerenke, David;Drewniak, James
    • Smart Structures and Systems
    • /
    • v.1 no.2
    • /
    • pp.141-158
    • /
    • 2005
  • A new design of distributed crack sensors based on the topological change of transmission line cables is presented for the condition assessment of reinforced concrete (RC) structures during and immediately after an earthquake event. This study is primarily focused on the performance of cable sensors under dynamic loading, particularly a feature that allows for some "memory" of the crack history of an RC member. This feature enables the post-earthquake condition assessment of structural members such as RC columns, in which the earthquake-induced cracks are closed immediately after an earthquake event due to gravity loads, and are visually undetectable. Factors affecting the onset of the feature were investigated experimentally with small-scale RC beams under cyclic loading. Test results indicated that both crack width and the number of loading cycles were instrumental in the onset of the memory feature of cable sensors. Practical issues related to dynamic acquisition with the sensors are discussed. The sensors were proven to be fatigue resistant from shake table tests of RC columns. The sensors continued to show useful performance after the columns can no longer support additional loads.

The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis

  • Sugiura, Tsutomu;Yamamoto, Kazuhiko;Horita, Satoshi;Murakami, Kazuhiro;Tsutsumi, Sadami;Kirita, Tadaaki
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.3
    • /
    • pp.152-165
    • /
    • 2016
  • Purpose: This study investigated the effects of bone density and crestal cortical bone thickness at the implant-placement site on micromotion (relative displacement between the implant and bone) and the peri-implant bone strain distribution under immediate-loading conditions. Methods: A three-dimensional finite element model of the posterior mandible with an implant was constructed. Various bone parameters were simulated, including low or high cancellous bone density, low or high crestal cortical bone density, and crestal cortical bone thicknesses ranging from 0.5 to 2.5 mm. Delayed- and immediate-loading conditions were simulated. A buccolingual oblique load of 200 N was applied to the top of the abutment. Results: The maximum extent of micromotion was approximately $100{\mu}m$ in the low-density cancellous bone models, whereas it was under $30{\mu}m$ in the high-density cancellous bone models. Crestal cortical bone thickness significantly affected the maximum micromotion in the low-density cancellous bone models. The minimum principal strain in the peri-implant cortical bone was affected by the density of the crestal cortical bone and cancellous bone to the same degree for both delayed and immediate loading. In the low-density cancellous bone models under immediate loading, the minimum principal strain in the peri-implant cortical bone decreased with an increase in crestal cortical bone thickness. Conclusions: Cancellous bone density may be a critical factor for avoiding excessive micromotion in immediately loaded implants. Crestal cortical bone thickness significantly affected the maximum extent of micromotion and peri-implant bone strain in simulations of low-density cancellous bone under immediate loading.