• Title/Summary/Keyword: Image rotation

Search Result 842, Processing Time 0.033 seconds

A Comparison on the Image Normalizations for Image Information Estimation

  • Kang, Hwan-Il;Lim, Seung-Chul;Kim, Kab-Il;Son, Young-I
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2385-2388
    • /
    • 2005
  • In this paper, we propose the estimation method for the image affine information for computer vision. The first estimation method is given based on the XYS image normalization and the second estimation method is based on the image normalization by Pei and Lin. The XYS normalization method turns out to have better performance than the method by Pei and Lin. In addition, we show that rotation and aspect ratio information can be obtained using the central moments of both the original image and the sensed image. Finally, we propose the modified version of the normalization method so that we may control the size of the image.

  • PDF

Verification of Indicator Rotation Correction Function of a Treatment Planning Program for Stereotactic Radiosurgery (방사선수술치료계획 프로그램의 지시자 회전 오차 교정 기능 점검)

  • Chung, Hyun-Tai;Lee, Re-Na
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.47-51
    • /
    • 2008
  • Objective: This study analyzed errors due to rotation or tilt of the magnetic resonance (MR) imaging indicator during image acquisition for a stereotactic radiosurgery. The error correction procedure of a commercially available stereotactic neurosurgery treatment planning program has been verified. Materials and Methods: Software virtual phantoms were built with stereotactic images generated by a commercial programming language, Interactive Data Language (version 5.5). The thickness of an image slice was 0.5 mm, pixel size was $0.5{\times}0.5mm$, field of view was 256 mm, and image resolution was $512{\times}512$. The images were generated under the DICOM 3.0 standard in order to be used with Leksell GammaPlan$^{(R)}$. For the verification of the rotation error correction function of Leksell GammaPlan$^{(R)}$, 45 measurement points were arranged in five axial planes. On each axial plane, there were nine measurement points along a square of length 100 mm. The center of the square was located on the z-axis and a measurement point was on the z-axis, too. Five axial planes were placed at z=-50.0, -30.0, 0.0, 30.0, 50.0 mm, respectively. The virtual phantom was rotated by $3^{\circ}$ around one of x, y, and z-axis. It was also rotated by $3^{\circ}$ around two axes of x, y, and z-axis, and rotated by $3^{\circ}$ along all three axes. The errors in the position of rotated measurement points were measured with Leksell GammaPlan$^{(R)}$ and the correction function was verified. Results: The image registration errors of the virtual phantom images was $0.1{\pm}0.1mm$ and it was within the requirement of stereotactic images. The maximum theoretical errors in position of measurement points were 2.6 mm for a rotation around one axis, 3.7 mm for a rotation around two axes, and 4.5 mm for a rotation around three axes. The measured errors in position was $0.1{\pm}0.1mm$ for a rotation around single axis, $0.2{\pm}0.2mm$ for double and triple axes. These small errors verified that the rotation error correction function of Leksell GammaPlan$^{(R)}$ is working fine. Conclusion: A virtual phantom was built to verify software functions of stereotactic neurosurgery treatment planning program. The error correction function of a commercial treatment planning program worked within nominal error range. The virtual phantom of this study can be applied in many other fields to verify various functions of treatment planning programs.

Wavelet circular harmonic function frequency selective joint transform correlator for rotation invariant pattern recognition (회전불변 패턴인식을 위한 WCHF-FSJTC)

  • 방준학;이하운;노덕수;김수중
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.2
    • /
    • pp.94-103
    • /
    • 1997
  • The WCHF-FSJTC (wavelet circular harmonic function frequency selective joint transform correlator) using th wavelet transformed CHF as the reference image in FSJTC is proposed for rotation invariant pattern recognition. Since the wavelet transform has the property of feature extraction, the proposed system can have the better DC (discrimination cpability) and the higher SNR(signal to noise ratio) compared with the conventional CHF-CJTC(circular harmonic function conventional joint transform correlator). And since the structure of the proposed system is FSJTC which can eliminate auto-correlation and cross-correlation between input images, it can eliminate false alarm caused by the overlapping among correlation peaks. The used wavelet functio is the morlet function, which is proper for the reference image used in this paper. the optimal dialation parameter and oscillation frequency of the wavelet function are also achieved with varying the parameters of the wavelet function. The computer simulation shows that the proposed system has the best performance when the dilation parameter is 0.8 and the oscillation frequency is 0.48.

  • PDF

Variation of Camera Constant and Image Rotation in HU-125C Electron Microscope (HU-125C 전자현미경에 있어서 카메라 상수의 변화 및 상의 회전에 대한 조사)

  • Choi, Ju;Ye, Gil-Chon
    • Applied Microscopy
    • /
    • v.4 no.1
    • /
    • pp.1-4
    • /
    • 1974
  • Variations of camera constant due to the change of the lens current were examined for Hitachi HU-125C electron microscope. It was shown that the variation in specimen height had a marked effect on the change of camera constant. Also the rotation of the image from the diffraction pattern was determined by using a test crystal. Suggestions were given for improving practical operation of electron microscope in the work of thin foils.

  • PDF

Evaluations on a Pressure-Field Calculation Method using PIV Synthetic Image (가상영상 PIV기반 압력장 계산법 평가)

  • Lee, Chang Je;Cho, Gyong Rae;Kim, Uei Kan;Kim, Dong Hyuk;Doh, Deog Hee
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.2
    • /
    • pp.46-51
    • /
    • 2016
  • In this study, a Masked Omni-Directional Integration(MODI) method for pressure calculation is proposed using the Particle Image Velocimetry (PIV) data. To obtain the velocity field, the Affine PIV method was adopted. Synthetic images were generated for a solid body rotation. Calculation on the pressure was based on the Navier-Stokes equation. The results obtained by the MODI were compared with those obtained by theoretical pressure and by the Omni-Directional Integration(ODI) method. It was shown that the minimum error by the proposed MODI method was attained when the mask size was 1.

Rotation-Invariant Pattern Recognition of the Multiple Circular Harmonic Filter Using Proper Center (적정의 중심점을 이용한 다중 원형 고조 필터의 회전 불변적 형태 인식)

  • 김종찬;도양회;김수중
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.1
    • /
    • pp.130-136
    • /
    • 1990
  • For the rotation-invariant pattern recognition, we propose multiple circular harmonic filter which is expanded about the proper center. The proper centerm when input image is given, is the circular harmonic expansion center of the filter which yields a maximum center correlation peak in the output plane. In this paper, we founded the circular harmonic components that the proper center superposes on the same position and then designed multiple circular harmonic filter using these components. Also the proposed filter is compared with conventional multiple circular harmonic filter and shows that it can maximize the center correlation peak for the rotated input image by the computer simulation.

  • PDF

Automatic detection of the lung orientation in digital PA chest radiographs

  • Nahm, Kie-B.
    • Journal of the Optical Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.60-64
    • /
    • 1997
  • An image processing algorithm is presented that can identify the orientation as well as the left/right side (parity) of the digitized radiographs. The orientation was found by computing the mean square deviation between the sampled gray values along the center and their best-fit linear regression relations. The parity was determined by comparing the area difference between two thresholded images of the left and the right side around the heart, which is assumed to be around the center of the image. This method was tested with 86 images with their orientations intentionally rotated. The rotation was limited to multiples of 90 degrees, as this was the way the rotation is most likely to happen in the clinical environment. We obtained positive responses for 85 out of 86 images subject to the screening.

Size, Scale and Rotation Invariant Proposed Feature vectors for Trademark Recognition

  • Faisal zafa, Muhammad;Mohamad, Dzulkifli
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1420-1423
    • /
    • 2002
  • The classification and recognition of two-dimensional trademark patterns independently of their position, orientation, size and scale by proposing two feature vectors has been discussed. The paper presents experimentation on two feature vectors showing size- invariance and scale-invariance respectively. Both feature vectors are equally invariant to rotation as well. The feature extraction is based on local as well as global statistics of the image. These feature vectors have appealing mathematical simplicity and are versatile. The results so far have shown the best performance of the developed system based on these unique sets of feature. The goal has been achieved by segmenting the image using connected-component (nearest neighbours) algorithm. Second part of this work considers the possibility of using back propagation neural networks (BPN) for the learning and matching tasks, by simply feeding the feature vectosr. The effectiveness of the proposed feature vectors is tested with various trademarks, not used in learning phase.

  • PDF

Outlier rejection in automobile-mounted NFOV camera (지능화 차량을 위한 오정합점 제거 방법)

  • Suhr, Jae-Kyu;Bea, Kwang-Hyuk;Jung, Ho-Gi;Kim, Jai-Hie
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.375-376
    • /
    • 2007
  • This paper proposes an algorithm for rejecting mismatched points (known as outliers). The proposed algorithm identifies and rejects outliers in image pairs obtained under automobile-like motions which consist of two translations and one rotation. The camera rotation is approximated to the image shift by assuming that the narrow field of lens is used. The voting method estimates the focus of expansion (FOE) while shifting one of the images. Using the properties of the FOE, the outliers are rejected while most of the inliers are retained.

  • PDF

Correction of Rotated Region in Medical Images Using SIFT Features (SIFT 특징을 이용한 의료 영상의 회전 영역 보정)

  • Kim, Ji-Hong;Jang, Ick-Hoon
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.1
    • /
    • pp.17-24
    • /
    • 2015
  • In this paper, a novel scheme for correcting rotated region in medical images using SIFT(Scale Invariant Feature Transform) algorithm is presented. Using the feature extraction function of SIFT, the rotation angle of rotated object in medical images is calculated as follows. First, keypoints of both reference and rotated medical images are extracted by SIFT. Second, the matching process is performed to the keypoints located at the predetermined ROI(Region Of Interest) at which objects are not cropped or added by rotating the image. Finally, degrees of matched keypoints are calculated and the rotation angle of the rotated object is determined by averaging the difference of the degrees. The simulation results show that the proposed scheme has excellent performance for correcting the rotated region in medical images.